GP-305 / GP-503
GP-505 / GP-3010
SAFETY SUMMARY
SAFETY PRECAUTIONS
SYMBOLS
Caution, risk of electric shocks.
Easily-touched higher temperature parts.
For proper use of this product, please read this manual carefully.
1. To maintain the precision and the reliability of the product , use it in the standard
setting.
2. For quality improvement , the exterior design and specifications of the product
can be changed without notice.
WARRANTY
We charge for repairs after the one year warranty period expires.
[1 ]
CONTENTS
1. INTRODUCTION
2. FEATURES
3. PRECAUTIONS
3-3. Cleaning
4. SPECIFICATION
5. PANEL DECRIPTION
6.OPERATIONS
[2]
1. INTRODUCTION
GP-305 , 3010 , 503 , 505 series are regulated DC POWER SULLPY units with voltmeter
and amperemeter : GP-305 can supply the DC power of 0 to 30V/5A
GP-503 can supply 0 to 50V/3A.
GP-505 can supply 0 to 50V/5A.
They are provided with continuously variable coarse adjustment and the output voltages,
and with continuously variable current adjustment in a range of 10 to 100%.
Current limiting and overload protection functions are built in to protect the load under
any circumstances.
The supply features anloge voltmeter and amperemeter, enabling the user to monitor
the supply's operation at a glance.
LEDs for Constant current ( C.C ) and Constant Voltage ( C.V ) enables monitoring of
operation status.
2. FEATURE
[3]
3. PRECAUTIONS
This instrument must be operated with the correct line voltage selector switch setting
and the correct line fuse for the line voltage selected to prevent damage.
The instrument operates from either a 90V to 132V or 198V to 250V line source.
Before line voltage is applied to the instrument , make sure the line voltage selector
switch is set correctly.
In the case of the line voltage selector switch selected , must be operated to the
correct line fuse.
2. Pull out the line voltage selector switch on the bottom panel.
Select the arrow mark position of the switch from Table 3-1.
Select the arrow mark to the desired position and plug it in.
3. Pull out the line fuse holder containing the fuse for overload protection.
Replace the fuse in the holder with the correct fuse from table3-1 & plug it in.
When placing the power supply in service at your workplace,observe the following
precautions for best instrument performance and longest service life.
2. Don't use this instrument immediately after bring it in from the cold.
Allow time for it to warm to room temperature. Similary don't move it from a
warm place to a very cold place,as condensation might impair its operation.
[4]
4. Do not place liquid-filled containers on top of this instrument.
A spill could seriously damage the instrument.
5. Do not use this instrument where it is subject to serve viration,or strong blows.
6.Do not place heavery objects on the case,or otherwise block the ventilation hole
7. Do not use this power supply in strong magnetic fields,such as near motors.
10. Do not place this instrument face down on the ground, or damage to the knob
may resuit.
13. According to output porarity, it solved problem ESD and Floating voltage using
the connect ground port to terminal of output .
3-3. Cleaning
1. To clean stained casing, lightly rub the stained area with a soft cloth dipped in a
neutral detergent.
2. If the surface of the panel is dirty, use the same method to clean.
If the panel is heavily stained, rub the affected area lighty with a soft cloth soaked
in light neutral detergent or alcohol.
[5]
4. SPECIFICATIONS
7 C.C C.V 9
POWER CURRENT VOLTAGE
LIMIT - GND + COARSE FINE
ON
2
6 OFF
1 3 11 13 12 5 4
2. C.V LED : Display LED for static state current & voltage operating.
3. CURRENT VR : The current limiting knob for setting and adjusting the output current in a
range of max. 10 ~100%
10. VOLTAGE METER : Set an output voltage while reading the voltage indication.
13. OUTPUT TERMINAL (GND) : When the positive polarity or negative polarity is to be connected to
the ground,either an appropriate output terminal should be connected
to the GND by a short circuit bar supplied as accessory.
When no bar connection is made,the terminal is used as the ground terminal
[7]
5-2. Rear Panel Description
1 2
1. DC FAN
2. SERIAL NUMBER
3. AC INLET
4. VENTILATION
[8]
The specifications are subjected to change without notice.