0% found this document useful (0 votes)
395 views

Spring Support Data Sheet-Process Area

This document provides information on spring data and operating loads for 16 springs used in an NF3 plant. For each spring, it lists the spring mark number, type, associated line/equipment, operating loads for calibration, hydrotest, and lock device, and stress file references. Most springs have vertical and horizontal movement rates specified. Load flanges for some springs must be made of graphite or teflon plates to accommodate high temperatures.

Uploaded by

Arash Aghagol
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
395 views

Spring Support Data Sheet-Process Area

This document provides information on spring data and operating loads for 16 springs used in an NF3 plant. For each spring, it lists the spring mark number, type, associated line/equipment, operating loads for calibration, hydrotest, and lock device, and stress file references. Most springs have vertical and horizontal movement rates specified. Load flanges for some springs must be made of graphite or teflon plates to accommodate high temperatures.

Uploaded by

Arash Aghagol
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

OWNER: PROJECT: OWNER DOCUMENT NO. NCE DOCUMENT NO.

NATIONAL PETROCHEMICAL COMPANY


NF3 PLANT OF BIPC NCE JOB NO. TYPE SIZE GROUP DOC.NO
PETROCHEMICAL INDUSTRIES
DEVELOPMENT MANAGEMENT COMPANY DSH-4-PI-008/1 1211-PA DS 4 ETG 60221

SHEET: 1 OF 1 REV. C1

SPRING DATA (1) OPERATING LOADS (N) Spring STRESS FILE (Reference)
SPRING LINE NO. Vertical Horizontal
No. REV QUANTITY Pos. No.
MARK No. / EQUIPMENT
Rate
Mov.(mm.) Mov.(mm.)
Accessories(See Attached Files) Remarks
TYPE NO. OPERATION CALIBRATION HYDROTEST LOCK DEVICE (N/mm.) SYSTEM No. NODE No.

1 C1 1 HVS-001 DV140 19 TYPE F 20"-HPS-8800-6D03-H 79,500 68,000 98,000 Yes 310.00 -37.00 35.00 1211-111-A0 30000 - LOAD FLANG MUST BE WITH GRAPHITE PLATE OR EQUAL FOR HIGH TEMPERATURE

2 C1 1 HVS-002 DV140 19 TYPE F 20"-HPS-8800-6D03-H 81,100 66,000 -69,000 Yes 310.00 -48.00 30.00 1211-111-A0 30200 - LOAD FLANG MUST BE WITH GRAPHITE PLATE OR EQUAL FOR HIGH TEMPERATURE

3 C1 1 HVS-003 DV140 17 TYPE F 20"-HPS-8800-6D03-H 50,300 59,000 59,000 Yes 175.10 -40.50 26.00 1211-111-A0 30100 - LOAD FLANG MUST BE WITH GRAPHITE PLATE OR EQUAL FOR HIGH TEMPERATURE

4 C1 1 HVS-004 DV70 16 TYPE F 28"-PRO-3001-IC16-N(BUT) 31,850 38,000 45,150 Yes 262.70 24.50 5.00 1211-114-A0 116 - LOAD FLANG MUST BE WITH TEFLON PLATE
5 C1 1 HVS-005 DV35 14 TYPE F 28"-PRO-3001-IC16-N(BUT) 20,000 20,000 45,000 Yes 280.20 -2.00 7.00 1211-114-A0 30000 - DELETED
6 C1 1 HVS-006 DV35 14 TYPE F 28"-PRO-3001-IC16-N(BUT) 20,000 20,000 40,000 Yes 280.20 2.00 7.00 1211-114-A0 30010 - DELETED
7 C1 1 HVS-007 DV35 13 TYPE F 20"-PRO-3055-1C16-N(PEN) 13,500 13,500 20,000 Yes 216.20 2.00 7.00 1211-114-A0 30020 - DELETED
8 C1 1 HVS-008 DV35 13 TYPE F 20"-PRO-3055-1C16-N(PEN) 13,500 13,500 20,000 Yes 216.20 -2.00 7.00 1211-114-A0 30030 - DELETED
H02-CP-42P-2042/AT01-H/AT13-42/
9 C1 1 HVS-009 DV70 16 TYPE B 44"-REF-2161-3B03-C(PR-101) 36000 35970 23300 Yes 262.7 -0.15 13.5 1211-133-B0 2082 AT16-42/AT20-42/AT28-Q/AT15-42
H02-CP-42P-2042/AT01-H/AT13-42/
10 C1 1 HVS-010 DV70 16 TYPE B 44"-REF-2161-3B03-C(PR-101) 36000 35970 29500 Yes 262.7 -0.15 13.5 1211-133-B0 2084 AT16-42/AT20-42/AT28-Q/AT15-42
SPRING SALL BE LOCKED IN EMPTY CASE,
11 C1 1 HVS-011 DV70 12 TYPE F 10"-MPC-8812-3C13-H(PR103) 9985 10556 10065 Yes 79 7.3 12.5 1211-148-A0 25 - LOAD FLANG MUST BE WITH GRAPHITE PLATE OR EQUAL FOR HIGH
TEMPERATURE
H02-CN-42R-1500/AT01-H/AT13-42/
12 C1 1 HVS-012 DV70 17 TYPE B 28"-PRO-1152-3C16-H(PRO) 47500 51325 65331 Yes 350 10.91 5.50 1211-159-A0 436
AT16-42/AT20-42/AT06-U/AT15-42
13 C1 1 HVS-013 DV70 17 TYPE F 28"-PRO-1248-3C16-H(PRO) 48300 51325 64750 Yes 350 9.6 4.7 1211-160-A0 437 - LOAD FLANG MUST BE WITH TEFLON PLATE
14 C1 1 HVS-014 DV35 15 TYPE F 20"-NGL-8505-1F01-N(FLC) 25053 24927 37753 Yes 378 -0.2 0.5 1211-162-A0 1119 - LOAD FLANG MUST BE WITH TEFLON PLATE
15 C1 1 HVS-015 DV70 13 TYPE F 18"-PRO-1168-3C16-N(PRO) 13200 13821 13760 Yes 105 5.9 3.8 1211-163-A0 17 - LOAD FLANG MUST BE WITH TEFLON PLATE
H02-CN-42P-1500/AT01-H/AT13-42/
16 C1 1 HVS-016 DV35 12 TYPE B 24"-PRO-3005-1C16-H(BUT) 9465 10375 25902 Yes 158 5.8 3.2 1211-117-A0 50 AT16-42/AT20-42/AT06-Q/AT15-42
TEMPERORY SUPPORT MUST BE USED FOR HYDROTEST
H02-CN-42P-1315/AT01-H/AT13-42/
17 C1 1 HVS-017 DV35 14 TYPE B 24"-PRO-3005-1C16-H(BUT) 15938 17022 43601 Yes 280 3.9 5.6 1211-117-A0 75 AT16-42/AT20-42/AT06-Q
TEMPERORY SUPPORT MUST BE USED FOR HYDROTEST
H02-CH-24M-1725/AT01-E/AT13-24/
18 C1 1 HVS-018 DV35 8 TYPE B 16"-PRO-3003-1C16-H(BUT) 3815 3628 5488 Yes 52 -3.6 4.8 1211-118-A0 65 AT16-24/AT20-24/AT07-N/AT15-24
H02-CH-30O-1500/AT01-F/AT13-30/
19 C1 1 HVS-019 DV35 10 TYPE B 20"-PRO-3061-1C16-H(PEN) 5923 6526 19105 Yes 91 6.7 9.5 1211-122-A0 35 AT16-30/AT20-30/AT07-P/AT15-30
TEMPERORY SUPPORT MUST BE USED FOR HYDROTEST
H02-CN-42O-1395/AT01-H/AT13-42/
20 C1 1 HVS-020 DV35 12 TYPE B 20"-PRO-3061-1C16-H(PEN) 9081 9761 31467 Yes 158 4.32 2 1211-122-A0 60 AT16-42/AT20-42/AT06-P
21 C1 1 HVS-021 DV35 13 TYPE F 24"-PRO-1150-3C16-H(PRO) 15000 13628 8609 Yes 210 -6.6 5.8 1211-157-A0 10000 - LOAD FLANG MUST BE WITH TEFLON PLATE
22 C1 1 HVS-022 DV35 13 TYPE F 24"-PRO-1246-3C16-H(PRO) 15000 13628 6587 Yes 210 -6.6 5.5 1211-157-A0 10100 - LOAD FLANG MUST BE WITH TEFLON PLATE
H02-CN-42P-1500/AT01-H/AT13-42/
23 C1 1 HVS-023 DV35 13 TYPE B 24"-PRO-2004-3C16-H(ETA) 13587 14523 29608 Yes 210 4.5 1.5 1211-161-A0 370 AT16-42/AT20-42/AT06-Q/AT15-42
TEMPERORY SUPPORT MUST BE USED FOR HYDROTEST
H02-CN-42P-1500/AT01-H/AT13-42/
24 C1 1 HVS-024 DV35 14 TYPE B 24"-PRO-2004-3C16-H(ETA) 17000 17919 32766 Yes 280 3.3 4.3 1211-161-A0 395 AT16-42/AT20-42/AT06-Q/AT15-42
H02-CJ-20J-1125/AT01-D/AT13-20/
25 C1 1 HVS-025 DV35 9 TYPE B 10"-REF-7079-3B03-C(C2R) 4968 5174 5565 Yes 70 3 0.5 1211-180-A0 100 AT16-20/AT20-20/AT29-K
26 C1 1 HVS-026 DV35 9 TYPE F 12"-REF-7077-3F01-C(C2R) 4717 5100 8296 Yes 70 4.8 0.1 1211-177-A0 3940 - LOAD FLANG MUST BE WITH TEFLON PLATE
27 C1 1 HVS-027 DV35 9 TYPE F 12"-REF-7078-3F01-C(C2R) 5000 5289 6464 Yes 70 3.7 0.1 1211-178-A0 5000 - LOAD FLANG MUST BE WITH TEFLON PLATE
LOAD FLANG MUST BE WITH TEFLON PLATE
28 C1 1 HVS-028 DV70 14 TYPE F 28"-PRO-3001-IC16-N(BUT) 18050 20336 68700 Yes 140 17.5 3 1211-114-A0 206 -
TEMPERORY SUPPORT MUST BE USED FOR HYDROTEST
29 C1 1 HVS-029 DV70 16 TYPE F 36"-REF-5014-3C16-C(C3R) 35300 34624 55500 Yes 262.7 -2.95 1.8 1211-133-B0 14500 - LOAD FLANG MUST BE WITH TEFLON PLATE
H02-CN-42M-1500/AT01-H/AT13-42/
30 C1 1 HVS-030 DV70 15 TYPE B 28"-REF-5057-3C16-H(C3R) 21050 21350 12500 Yes 189.1 3.2 1 1211-133-A0 5094
AT16-42/AT20-42/AT06-N/AT15-42
H02-CN-42M-1500/AT01-H/AT13-42/
31 C1 1 HVS-031 DV70 16 TYPE B 28"-REF-5057-3C16-H(C3R) 32950 33350 29700 Yes 262.7 3.1 0.8 1211-133-A0 5092 AT16-42/AT20-42/AT06-N/AT15-42
H2-CY-64V-2000/AT01-L/AT13-64/
32 C1 1 HVS-032 DV70 21 TYPE B 42"-REF-5041-3B03-C(C3R) 139010 145000 107500 Yes 1094.5 5.5 13 1211-156-A0 80
AT16-64/AT12-64/AT15-64
H2-CY-64V-2000/AT01-L/AT13-64/
33 C1 1 HVS-033 DV70 20 TYPE B 42"-REF-5041-3B03-C(C3R). 103990 110000 33040 Yes 823.1 7.35 3 1211-156-A0 222 AT16-64/AT12-64/AT15-64
34 C1 1 HVS-034 DV35 16 TYPE F 30"-REF-5038-3C16-C(C3R.) 37980 40000 56248 Yes 525.4 3.95 1.6 1211-158-A0 4000 - LOAD FLANG MUST BE WITH TEFLON PLATE
35 C1 1 HVS-035 DV35 14 TYPE F 16"-REF-5006-3C16-H(C3R) 15750 15000 29200 Yes 280.2 -2.61 0.1 1211-168-A0 1100 - LOAD FLANG MUST BE WITH TEFLON PLATE
36 C1 1 HVS-036 DV140 12 TYPE F 16"-HPS-8803-6D03-H(C3R) 9958 9000 9380 Yes 39.5 -24.5 22 1211-111-A0 31610 - LOAD FLANG MUST BE WITH GRAPHITE PLATE OR EQUAL FOR HIGH TEMPERATURE
H02-CN-36K-1650/AT01-36/AT13-36/
37 C1 1 HVS-037 DV70 11 TYPE B 12"-MPS-5096-3C13-H(C3R) 8670 8000 7010 Yes 59.5 -11.2 13.8 1211-111-A0 12530
AT16-36/AT20-36/AT06-L/AT15-36

1)Spring Data is based on carpenter Paterson Ltd