0% found this document useful (0 votes)
20 views

I. Short Span Direction: How To: Insert Values On Highlighted Spaces (Cells) - See Result at Table (Coefficient)

This document provides information to design the reinforcement for a two-way slab using the coefficient method. It includes the material properties, slab dimensions, and calculated moments and coefficients for different regions of the slab in both the short and long span directions. The minimum reinforcement ratios and bar sizes are then determined.

Uploaded by

Japoy
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views

I. Short Span Direction: How To: Insert Values On Highlighted Spaces (Cells) - See Result at Table (Coefficient)

This document provides information to design the reinforcement for a two-way slab using the coefficient method. It includes the material properties, slab dimensions, and calculated moments and coefficients for different regions of the slab in both the short and long span directions. The minimum reinforcement ratios and bar sizes are then determined.

Uploaded by

Japoy
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 7

Two-way Slab (Coefficient Method)

fc' = 20 Wd = 3.5 S= 5
fy = 400 Wl = 5 L= 6
Wu = 12.2

Slab Thickness:
h = 122.2222 say 130

Middle Strip Moment:

Mu = C305
How to:
I. Short Span Direction ( N - S Direction) Insert Values on highlig
See result @ Table(Coe
Note: not guaranteed co
d= 104

A. Middle Strip b= 1000

@ Negative Moment at continuous edge (top bar) Case = 1

Span Ratio = 0.833333 Short Span Ratio


1 0.9
-Mu = 14.03 0.033 0.04

C= 0.0453333333

@ Negative Moment at discontinuous edge ( top bar) Case = 1

Span Ratio = 0.833333 Short Span Ratio


1 0.9
-Mu = - -

C= no discontinouous edge

@ Positive Moment at midspan Case = 1

Span Ratio = 0.833333 Short Span Ratio


1 0.9
Mu = 10.37 0.025 0.03

C= 0.034
B. Column Strip b= 1000

@ Negative Moment at continuous edge (top bar)

-Mu = 9.353333

@ Negative Moment at discontinuous edge ( top bar)

-Mu =

@ Positive Moment at midspan

Mu = 6.913333

II. Long Span Direction ( E - W Direction )

d= 92

A. Middle Strip b= 1000

@ Negative Moment at continuous edge (top bar) Case = 1

Span Ratio = 0.833333 All Span Ratio


C=
-Mu = 10.065

@ Negative Moment at discontinuous edge ( top bar) Case = 1

Span Ratio = 0.833333 All Span Ratio


C=
-Mu =

@ Positive Moment at midspan Case = 1

Span Ratio = 0.833333 All Span Ratio


C=
Mu = 7.625

B. Column Strip b= 1000

@ Negative Moment at continuous edge (top bar)

-Mu = 6.71
@ Negative Moment at discontinuous edge ( top bar)

-Mu =

@ Positive Moment at midspan

Mu = 5.083333
cover = 20
bar diameter = 12

ρmin = 0.0035
ρmin = 0.002795

use ρmin = 0.0035

How to:
Insert Values on highlighted spaces(cells).
See result @ Table(Coefficient)
Note: not guaranteed correct :D

Short Span Ratio


0.8 0.7 0.6 0.5
0.048 0.055 0.063 0.083

say 0.046

no discontinuous edge

Short Span Ratio


0.8 0.7 0.6 0.5
- - - -

say

Short Span Ratio


0.8 0.7 0.6 0.5
0.036 0.041 0.047 0.062

say 0.034
Span Ratio
0.033

no discontinuous edge

Span Ratio
no discontinuous edge

Span Ratio
0.025
fc' = 20 ( N-S Direction ) d=104mm S =5m ( E-W Direction ) d=mm S =2
fy = 400 Column Strip Middle Strip Column Strip
Ab = 113.0973355 1000 1000 1000
Negative Moment ( top bars @ support)
( continuous edge)
Mu = 9.3533333333 14.03 6.71
Mn = 10.3925925926 15.5888888889 7.4555555556
RN = 0.9608536051 1.4412804076 0.8808548624
ρ= 0.0024741507 0.0037704517 0.0022623517
use ρ = 0.0035 0.0037704517 0.0035
As = 364 392.1269743063 322
n-ø12mm 3.218466627 3.4671636823 2.8471050931
s-ø12mm 310.7069657397 288.4201876938 351.2339612709
use s-ø12mm

Negative Moment ( top bars @ support)


(discontinuous edge)
Mu =
Mn =
RN =
ρ=
use ρ =
As =
n-ø12mm
s-ø12mm
use s-ø12mm

Positive Moment ( bottom bars )


( @ midspan )
Mu = 6.9133333333 10.37 5.0833333333
Mn = 7.6814814815 11.5222222222 5.6481481481
RN = 0.7101961429 1.0652942143 0.6673142897
ρ= 0.0018142123 0.0027523588 0.001702381
use ρ = 0.0035 0.0035 0.0035
As = 364 364 322
n-ø12mm 3.218466627 3.218466627 2.8471050931
s-ø12mm 310.7069657397 310.7069657397 351.2339612709
use s-ø12mm
Direction ) d=mm S =20m
Middle Strip
1000

10.065
11.1833333333
1.3212822936
0.0034426382
0.0035
322
2.8471050931
351.2339612709

7.625
8.4722222222
1.0009714346
0.002580787
0.0035
322
2.8471050931
351.2339612709

You might also like