The document contains a logic diagram with inputs, outputs, and logic blocks. It uses buttons, sensors, relays, and timers to control motors, lights, and cylinders. The start and stop buttons activate latching relays to power the devices. Sensors provide feedback and additional timers control sequencing of the cylinders and motor.

Uploaded by

Ramon Peterle
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views

Ladder - Logo!

The document contains a logic diagram with inputs, outputs, and logic blocks. It uses buttons, sensors, relays, and timers to control motors, lights, and cylinders. The start and stop buttons activate latching relays to power the devices. Sensors provide feedback and additional timers control sequencing of the cylinders and motor.

Uploaded by

Ramon Peterle
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

BOTÃO START

I1

T002

BOTÃO STOP
I2 SF003
S
R RS
Par
Rem = off

SENSOR 2
I4

SENSOR 4
I6

MOTOR
SF003 Q1

BOTÃO START
I1

BOTÃO STOP
I2 SF004
S
R RS
Par
Rem = off

LAMPADA
SF004 Q2

BOTÃO START
I1

SENSOR 1
I3 SF005
S
R RS
Par
Rem = off

BOTÃO STOP
I2

CILINDRO 1
SF005 Q3

Creator: ramon Project: Customer:


Checked: Installation: Diagram No.:
Date: 6/25/18 9:54 PM/6/26/18 12:02 AM File: LADDER - LOGO!.lld Page: 1/4
SENSOR 2
I4

M1 SF006
S
R RS
Par
Rem = off

BOTÃO STOP
I2

CILINDRO 2
SF006 Q4

SENSOR 3
I5 T001
Trg

T
Rem = off
06:00s+

T001

SENSOR 4
I6 SF007
S
R RS
Par
Rem = off

BOTÃO STOP
I2

SF007 M1

M1 T002
Trg

T
Rem = off
02:00s+

Creator: ramon Project: Customer:


Checked: Installation: Diagram No.:
Date: 6/25/18 9:54 PM/6/26/18 12:02 AM File: LADDER - LOGO!.lld Page: 2/4
Block Number (Type) Parameter

I1(Make contact) :
BOTÃO START

I1(Make contact) :
BOTÃO START

I1(Make contact) :
BOTÃO START

I2(Make contact) :
BOTÃO STOP

I2(Make contact) :
BOTÃO STOP

I2(Make contact) :
BOTÃO STOP

I2(Make contact) :
BOTÃO STOP

I2(Make contact) :
BOTÃO STOP

I3(Make contact) :
SENSOR 1

I4(Make contact) :
SENSOR 2

I4(Make contact) :
SENSOR 2

I5(Make contact) :
SENSOR 3

I6(Make contact) :
SENSOR 4

I6(Make contact) :
SENSOR 4

Q1(Relay coil) :
MOTOR

Q2(Relay coil) :
LAMPADA

Q3(Relay coil) :
CILINDRO 1

Q4(Relay coil) :
CILINDRO 2

SF003(Latching Relay) : Rem = off

SF004(Latching Relay) : Rem = off

SF005(Latching Relay) : Rem = off

Creator: ramon Project: Customer:


Checked: Installation: Diagram No.:
Date: 6/25/18 9:54 PM/6/26/18 12:02 AM File: LADDER - LOGO!.lld Page: 3/4
Block Number (Type) Parameter

SF006(Latching Relay) : Rem = off

SF007(Latching Relay) : Rem = off

T001(On-Delay) : Rem = off


06:00s+

T002(On-Delay) : Rem = off


02:00s+

Creator: ramon Project: Customer: