Vitapia7000k Patient Monitor

This document summarizes the specifications of the Multi Parameter Patient Monitor VITAPIA7000K. It has a 12.1" high brightness LCD display, portable design, and can display ECG waveforms from 7 leads on one screen. It can review trends for 72 hours or 480 hours with an external memory. Additional optional parameters include IBP, temperature, recorder, 12-lead ECG, EtCO2, and networking capabilities.

Uploaded by

Sveto Sl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
692 views

Vitapia7000k Patient Monitor

This document summarizes the specifications of the Multi Parameter Patient Monitor VITAPIA7000K. It has a 12.1" high brightness LCD display, portable design, and can display ECG waveforms from 7 leads on one screen. It can review trends for 72 hours or 480 hours with an external memory. Additional optional parameters include IBP, temperature, recorder, 12-lead ECG, EtCO2, and networking capabilities.

Uploaded by

Sveto Sl
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Multi Parameter Patient Monitor

·12.1”High brightness TFT LCD display


·Portable & streamline handle design
·Big figure display
·ECG waveforms of 7-lead display in one screen
·72 hours review trend
·480 hours review trend with external memory
·Compatible and self-identify 3/5-lead ECG cable
·NIBP dual over pressure protection
·Isolated floating, anti-defibrillation protected and anti-high
frequency interference
·Networking capacity with standard parameter and configuration
·Optional parameter & configuration :
2-IBP, 2-TEMP, Recorder, 12-lead ECG, EtCO2
Central Network S/W, Wireless Network, VGA, Touch LCD

Satisfaction Superiority Specialization


Multi Parameter Patient Monitor VITAPIA7000K Technical Specifications
Classification Method Oscillometric
Anti-electroshock type Class I equipment and internal powered equipment Mode Manual, Auto, STAT
EMC type Class A Measuring Interval
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480, 960 min
in AUTO Mode
Anti-electroshock degree ECG(RESP), SPO2, NIBP, IBP, TEMP, CO2 CF
Measuring period in
Specifications 5 min
STAT Mode
Size Monitor 310 X 140 X 263 mm
Alarm Type SYS, DIA, MEAN
Weight Monitor 3.8 kg
Working 5 ~ 40℃ Measuring and alarm Range
Temperature
Transport/ Storage -40 ~ +55℃ · SYS : 40 ~ 270 mmHg
Working 30% ~ 75% Adult mode · DIA : 10 ~ 215 mmHg
Humidity NIBP · MEAN : 20 ~ 235 mmHg
Transport/ Storage ≤ 95% (no coagulate)
· SYS : 40 ~ 200 mmHg
Working 700hPa ~ 1060hPa Pediatric mode · DIA : 10 ~ 150 mmHg
Altitude
Transport/ Storage -500hPa ~ 1060hPa · MEAN : 20 ~ 165 mmHg
Power Supply 100~240 VAC, 50 / 60 Hz, Pmax = 150 VA, FUSE T1.6A · SYS : 40 ~ 135 mmHg
Device 12.1 in. color TFT, 3 LED / 800 X 600 dots Neonatal mode · DIA : 10 ~ 100 mmHg
· MEAN : 20 ~ 110 mmHg
Touch LCD(Option) viewing angle (up :70° down:70° left:50° right:60° and the best angle is 60°)
Display Resolution Pressure : 1 mmHg
·8 Waveforms Maximum ·1 Alarm LED (Yellow/Red)
Messages ·1 Power LED (Green) ·1 Battery Charge LED (Yellow) · Pressure(Maximum Mean error) : ±5 mmHg
Accuracy
·3 Sound Mode corresponding Alarm Mode · Pressure(Maximum Standard deviation) : ±8 mmHg
ECG Output BNC · Adult mode : 297±3 mmHg
Overpressure
· Pediatric mode : 240±3 mmHg
Amplitude 1 mV protection
· Neonatal mode : 147±3 mmHg
Signal Interface Accuracy <5%
Measuring Range 0 ~ 100%
Impedance 50 Ω
Alarm Range 0 ~ 100%
Signal Delay <20 ms
Resolution 1%
· Rechargeable 3.7 A/Hr 7.4 V Li battery
Battery · Operating time under the normal use and full charge greater than 120 min. · 70 ~ 100% ±2%
Accuracy
· Operating time after the first alarm of low battery will be about 5 min. SpO2 · 0% ~ 69% unspecified
Record Width 48 mm Actualization interval about 1 sec
Recorder (Option) Paper Speed 25 mm/s or 50 mm/s Alarm Delay 10 sec
Trace 2 · Measuring and Alarm Range : 0 ~ 250 bpm
Pulse Rate · Resolution : 1 bpm
· Short : 1 hrs, 1 second Resolution · Accuracy : ±2 bpm
Trend Recall
· Long : 72 hrs, 1 min Resolution
Channel 2
Alarm Event Recall 71 alarm events of all parameters and 8/16/32 seconds of corresponding waveform.
Recall Measuring and
0 ~ 50℃
NIBP Measurement Alarm Range
At least 400 NIBP measurement data
Recall Resolution 0.1℃
SD card · 72hrs ECG waveform · 480hrs TREND review TEMPERATURE
Accuracy ±0.2℃
Lead mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Actualization interval about 1 sec
Lead selection I, II, III, avR, avL, avF, V
Average Time
Waveform 2CH <10 sec
Constant
Lead mode 3 Leads (R, L, F, or RA, LA, LL) Channel 2
Lead selection I, II, III Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Waveform 1ch Measuring range -10 ~ +300mmHg
Gain x2.5 mm/mV, x5.0 mm/mV, x10 mm/mV, x20 mm/mV Alarm range -50 ~ +350mmHg
· Measuring Range : 15~300 bpm · Alarm Range(ADU) : 15~300 bpm IBP (Option) Press Sensor Sensitivity : 5 uV/V/mmHg
HR · Alarm Range(PED/NEO) : 15~350 bpm · Accuracy : ±1% or ±1 bpm , which great
Impedance : 300 ~ 3000 Ω
· Resolution : 1 bpm · Sensitivity : >200 uV P-P
Resolution 1 mmHg
Differential input >5 MΩ
impedance Accuracy ±2% or 1 mmHg which great
· Monitor : ≥100 dB Actualization Interval about 1 sec
CMRR · Operation : ≥100 dB Method Infra-red Absorption Technique
· Diagnosis : ≥60 dB
ECG Measuring mode Mainstream and Sidestream
Electrode offset
±300 mV Side-stream mode
potential 50 ml/Min. ± 10 ml/Min.
sampling gas flow rate
Leakage Current <10 uA
CO2 : 0 ~ 150 mmHg
Baseline Recovery <5s After Defi. Measuring range INSCO2 : 0 ~ 150 mmHg
ECG Signal Range ±8 mV (Vp-p) AwRR : 2 ~ 150 rpm
· Surgery : 1 ~ 20 Hz (+0.4 dB, -3 dB) CO2 : 0.1 mmHg (0 ~ 69 mmHg), 0.25 mmHg (70 ~ 150 mmHg)
Resolution
Bandwidth · Monitor : 0.5 Hz ~ 40 Hz (+0.4 dB, -3 dB) INSCO2 : 0.1 mmHg (0 ~ 69 mmHg), 0.25 mmHg (70 ~ 150 mmHg)
· Diagnostic : 0.05 Hz ~ 75 Hz (+0.4 dB, -3 dB), 76 Hz ~ 150 Hz (+0.4 dB, -4.5 dB) CO2 : ±2 mmHg, 0 ~ 40 mmHg
Calibration Signal 1 mV (Vp-p), ±5% Accuracy ±5% of reading, 41 ~ 70 mmHg
Accuracy ±8% of reading, 71 ~ 100 mmHg
ST Segment Measure Range : -0.6 ~ +0.8 mV
±10% of reading, 101 ~ 150 mmHg
Monitoring Range Alarm Range : -2.0 ~ +2.0 mV AwRR : ±1 rpm
Type : A
 SYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, Pace maker(Option) Available
TACHY, BRADY, MISSED BEATS, PNP, PNC CO2 (Option)
ARR Detecting Mainstream : Capnogram displayed in less than 15 sec at
Alarm : Available
an ambient temp. of 25℃, full specifications within 2 min
Review : Available Sidestream : Capnogram displayed in less than 20 sec at
Method Impedance between R-F (RA-LL) Initialization Time an ambient Temp. of 25℃, full specifications within 2 min
Differential Input Mainstream Rise Time : Less then 60ms-Adult Reusable
> 2.5 MΩ or Single-Patient-Use Airway Adapter Less then 60ms-
Impedance
Infant Reusable or Single-Patient-Use Airway Adapter
Measuring
0.3 ~ 5.0 Ω
Impedance Range Actualization interval about 1 sec
Base line Impedance Sidestream Delay
RESPARATION 0.1 ~ 2.5 KΩ 2 ~ 3 sec
Range Time
Bandwidth 0.3 ~ 2.5 Hz CO2 : 0 ~ 150 mmHg
·Measuring Range : 0 ~ 120 rpm ·Alarm Range(ADU) : 0~120rpm Alarm range InsCO2 : 0 ~ 150 mmHg
Resp. Rate ·Alarm Range(PED/NEO) : 0~150rpm ·Resolution : 1 rpm AwRR : 2 ~ 150 rpm
·Accuracy : ±2 rpm Suffocation Alarm
Apnea Alarm 10 ~ 40 S Delay AwRR : 10 ~ 60 sec

※Contents and specification subjects change without notice

TRISMED CO., LTD


409 SMECA, 65 Techno 3-ro, Yusung-gu, Daejon 305-509, Republic of Korea
Tel. +82-42-936-7201 Fax. +82-42-936-7202 E-mail. [email protected] / [email protected]
Satisfaction Superiority Specialization Home page. www.trismed.com / www.trismed.co.kr

Cat.No : RD-04-7600-A-001 Rev. -7- Printed in Korea