Slope Stability Analysis Analiza Interna Input Data
Slope Stability Analysis Analiza Interna Input Data
Input data
Project
Settings
Standard - EN 1997 - DA1
Stability analysis
Earthquake analysis : Standard
Verification methodology : according to EN 1997
Design approach : 1 - reduction of actions and soil parameters
Partial factors on actions (A)
Seismic design situation
Combination 1 Combination 2
Unfavourable Favourable Unfavourable Favourable
Permanent actions : G = 1.00 [–] 1.00 [–] 1.00 [–] 1.00 [–]
Variable actions : Q = 1.00 [–] 0.00 [–] 1.00 [–] 0.00 [–]
Water load : w = 1.00 [–] 1.00 [–]
1 Umpluturi 22.00
2 dorosol 24.00
5 Argilanisipoas 22.00
Soil parameters
Umpluturi
Unit weight : = 20.30 kN/m3
Stress-state : effective
Angle of internal friction : ef = 35.00 °
Cohesion of soil : cef = 0.00 kPa
Saturated unit weight : sat = 22.00 kN/m3
dorosol
Unit weight : = 23.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 22.00 °
Cohesion of soil : cef = 150.00 kPa
Saturated unit weight : sat = 24.00 kN/m3
Argila prafoasa
Unit weight : = 19.03 kN/m3
Stress-state : effective
Angle of internal friction : ef = 18.20 °
Cohesion of soil : cef = 33.00 kPa
Saturated unit weight : sat = 22.00 kN/m3
Argilanisipoas
Unit weight : = 19.33 kN/m3
Stress-state : effective
Angle of internal friction : ef = 16.10 °
Cohesion of soil : cef = 20.00 kPa
Saturated unit weight : sat = 22.00 kN/m3
Rigid bodies
No. Name Sample
[kN/m3]
1 Cover 25.00
Reinforcements
Point to the left Point to the right Length Strength End of
No. Pull out resist.
x [m] z [m] x [m] z [m] L [m] Rt [kN/m] reinf.
1 9.55 -0.20 2.05 -0.20 7.50 15.67 Tp = 5.69 kN/m2 Fixed
2 9.58 -0.65 2.08 -0.65 7.50 15.67 Tp = 18.48 kN/m2 Fixed
3 9.62 -1.10 2.12 -1.10 7.50 15.67 Tp = 31.27 kN/m2 Fixed
4 9.66 -1.55 2.16 -1.55 7.50 15.67 Tp = 44.06 kN/m2 Fixed
5 9.69 -2.00 2.19 -2.00 7.50 15.67 Tp = 56.86 kN/m2 Fixed
6 9.73 -2.45 2.23 -2.45 7.50 15.67 Tp = 69.65 kN/m2 Fixed
7 9.76 -2.90 2.26 -2.90 7.50 15.67 Tp = 82.44 kN/m2 Fixed
8 9.80 -3.35 2.30 -3.35 7.50 15.67 Tp = 95.24 kN/m2 Fixed
9 9.84 -3.80 2.34 -3.80 7.50 15.67 Tp = 108.03 kN/m2 Fixed
10 9.87 -4.25 2.37 -4.25 7.50 15.67 Tp = 120.82 kN/m2 Fixed
11 9.91 -4.70 2.41 -4.70 7.50 15.67 Tp = 133.61 kN/m2 Fixed
12 9.95 -5.15 2.45 -5.15 7.50 15.67 Tp = 146.41 kN/m2 Fixed
13 9.98 -5.60 2.48 -5.60 7.50 15.67 Tp = 159.20 kN/m2 Fixed
14 10.02 -6.05 2.52 -6.05 7.50 15.67 Tp = 171.99 kN/m2 Fixed
15 10.05 -6.50 2.55 -6.50 7.50 15.67 Tp = 184.78 kN/m2 Fixed
16 10.09 -6.95 2.59 -6.95 7.50 15.67 Tp = 197.58 kN/m2 Fixed
17 10.13 -7.40 2.63 -7.40 7.50 15.67 Tp = 210.37 kN/m2 Fixed
18 10.16 -7.85 2.66 -7.85 7.50 15.67 Tp = 223.16 kN/m2 Fixed
19 10.20 -8.30 2.70 -8.30 7.50 15.67 Tp = 235.96 kN/m2 Fixed
20 10.24 -8.75 2.74 -8.75 7.50 15.67 Tp = 248.75 kN/m2 Fixed
21 10.27 -9.20 2.77 -9.20 7.50 15.67 Tp = 261.54 kN/m2 Fixed
22 10.31 -9.65 2.81 -9.65 7.50 15.67 Tp = 274.33 kN/m2 Fixed
23 10.34 -10.10 2.84 -10.10 7.50 15.67 Tp = 140.92 kN/m2 Fixed
24 10.38 -10.55 2.88 -10.55 7.50 15.67 Tp = 146.65 kN/m2 Fixed
25 10.42 -11.00 2.92 -11.00 7.50 15.67 Tp = 152.37 kN/m2 Fixed
26 -0.02 -0.25 7.48 -0.25 7.50 15.67 Tp = 7.11 kN/m2 Fixed
27 -0.06 -0.70 7.44 -0.70 7.50 15.67 Tp = 19.90 kN/m2 Fixed
28 -0.09 -1.15 7.41 -1.15 7.50 15.67 Tp = 32.69 kN/m2 Fixed
29 -0.13 -1.60 7.37 -1.60 7.50 15.67 Tp = 45.49 kN/m2 Fixed
30 -0.17 -2.05 7.33 -2.05 7.50 15.67 Tp = 58.28 kN/m2 Fixed
31 -0.20 -2.50 7.30 -2.50 7.50 15.67 Tp = 71.07 kN/m2 Fixed
32 -0.24 -2.95 7.26 -2.95 7.50 15.67 Tp = 83.86 kN/m2 Fixed
33 -0.27 -3.40 7.23 -3.40 7.50 15.67 Tp = 96.66 kN/m2 Fixed
34 -0.31 -3.85 7.19 -3.85 7.50 15.67 Tp = 109.45 kN/m2 Fixed
Point to the left Point to the right Length Strength End of
No. Pull out resist.
x [m] z [m] x [m] z [m] L [m] Rt [kN/m] reinf.
35 -0.35 -4.30 7.15 -4.30 7.50 15.67 Tp = 122.24 kN/m2 Fixed
36 -0.38 -4.75 7.12 -4.75 7.50 15.67 Tp = 135.04 kN/m2 Fixed
37 -0.42 -5.20 7.08 -5.20 7.50 15.67 Tp = 147.83 kN/m2 Fixed
38 -0.46 -5.65 7.04 -5.65 7.50 15.67 Tp = 160.62 kN/m2 Fixed
39 -0.49 -6.10 7.01 -6.10 7.50 15.67 Tp = 173.41 kN/m2 Fixed
40 -0.53 -6.55 6.97 -6.55 7.50 15.67 Tp = 186.21 kN/m2 Fixed
41 -0.57 -7.00 6.93 -7.00 7.50 15.67 Tp = 199.00 kN/m2 Fixed
42 -0.60 -7.45 6.90 -7.45 7.50 15.67 Tp = 211.79 kN/m2 Fixed
43 -0.64 -7.90 6.86 -7.90 7.50 15.67 Tp = 224.58 kN/m2 Fixed
44 -0.68 -8.35 6.82 -8.35 7.50 15.67 Tp = 237.38 kN/m2 Fixed
45 -0.71 -8.80 6.79 -8.80 7.50 15.67 Tp = 250.17 kN/m2 Fixed
46 -0.75 -9.25 6.75 -9.25 7.50 15.67 Tp = 262.96 kN/m2 Fixed
47 -0.78 -9.70 6.72 -9.70 7.50 15.67 Tp = 275.76 kN/m2 Fixed
48 -0.82 -10.15 6.68 -10.15 7.50 15.67 Tp = 141.56 kN/m2 Fixed
49 -0.86 -10.60 6.64 -10.60 7.50 15.67 Tp = 147.28 kN/m2 Fixed
50 -0.89 -11.05 6.61 -11.05 7.50 15.67 Tp = 153.01 kN/m2 Fixed
Water
Water type : No water
Tensile crack
Tensile crack not inputted.
Earthquake
Horizontal seismic coefficient : Kh = 0.49
Vertical seismic coefficient : Kv = 0.16
Settings of the stage of construction
Design situation : seismic
Results (Stage of construction 1)
Analysis 1
Circular slip surface
Slip surface parameters
x= -4.67 [m] 1 = -33.97 [°]
Center : Angles :
z= 0.02 [m] 2 = 89.92 [°]
Radius : R= 13.89 [m]
The slip surface after optimization.
The restrictions of points of circular slip surface
Keep the left end point of the slip surface
Keep the right end point of the slip surface
Reinforcement forces
Combination 1
Reinforcement Force [kN/m]
1 15.67
2 15.67
3 15.67
4 15.67
5 15.67
6 15.67
7 15.67
8 15.67
9 15.67
10 15.67
11 15.67
12 15.67
13 15.67
14 15.67
15 15.67
16 15.67
17 15.67
18 15.67
19 15.67
20 15.67
21 15.67
22 15.67
23 15.67
24 15.67
25 15.67
26 0.00
27 0.00
28 0.00
29 0.00
30 0.00
31 0.00
32 0.00
33 0.00
34 0.00
35 0.00
36 0.00
37 0.00
38 0.00
39 0.00
40 0.00
41 0.00
42 0.00
43 15.67
44 15.67
45 15.67
46 15.67
47 15.67
48 15.67
49 15.67
50 15.67
Combination 2
Reinforcement Force [kN/m]
1 15.67
2 15.67
3 15.67
4 15.67
5 15.67
6 15.67
7 15.67
8 15.67
9 15.67
10 15.67
11 15.67
12 15.67
13 15.67
14 15.67
15 15.67
16 15.67
17 15.67
18 15.67
19 15.67
20 15.67
21 15.67
22 15.67
23 15.67
24 15.67
25 15.67
26 0.00
27 0.00
28 0.00
29 0.00
30 0.00
31 0.00
32 0.00
33 0.00
34 0.00
35 0.00
36 0.00
37 0.00
38 0.00
39 0.00
40 0.00
41 0.00
42 0.00
43 15.67
44 15.67
45 15.67
46 15.67
47 15.67
48 15.67
49 15.67
50 15.67
Slope stability verification (Spencer)
Combination 1
Utilization : 79.6 %
Slope stability ACCEPTABLE
Combination 2
Utilization : 99.5 %
Slope stability ACCEPTABLE
Optimized slip surface for : Combination 2
1 Umpluturi 22.00
2 dorosol 24.00
5 Argilanisipoas 22.00
Soil parameters
Umpluturi
Unit weight : = 20.30 kN/m3
Stress-state : effective
Angle of internal friction : ef = 35.00 °
Cohesion of soil : cef = 0.00 kPa
Saturated unit weight : sat = 22.00 kN/m3
dorosol
Unit weight : = 23.00 kN/m3
Stress-state : effective
Angle of internal friction : ef = 22.00 °
Cohesion of soil : cef = 150.00 kPa
Saturated unit weight : sat = 24.00 kN/m3
Argila prafoasa
Unit weight : = 19.03 kN/m3
Stress-state : effective
Angle of internal friction : ef = 18.20 °
Cohesion of soil : cef = 33.00 kPa
Saturated unit weight : sat = 22.00 kN/m3
Argilanisipoas
Unit weight : = 19.33 kN/m3
Stress-state : effective
Angle of internal friction : ef = 16.10 °
Cohesion of soil : cef = 20.00 kPa
Saturated unit weight : sat = 22.00 kN/m3
Rigid bodies
No. Name Sample
[kN/m3]
1 Cover 25.00
Reinforcements
Point to the left Point to the right Length Strength End of
No. Pull out resist.
x [m] z [m] x [m] z [m] L [m] Rt [kN/m] reinf.
1 9.55 -0.20 2.05 -0.20 7.50 15.67 Tp = 5.69 kN/m2 Fixed
2 9.58 -0.65 2.08 -0.65 7.50 15.67 Tp = 18.48 kN/m2 Fixed
3 9.62 -1.10 2.12 -1.10 7.50 15.67 Tp = 31.27 kN/m2 Fixed
4 9.66 -1.55 2.16 -1.55 7.50 15.67 Tp = 44.06 kN/m2 Fixed
5 9.69 -2.00 2.19 -2.00 7.50 15.67 Tp = 56.86 kN/m2 Fixed
6 9.73 -2.45 2.23 -2.45 7.50 15.67 Tp = 69.65 kN/m2 Fixed
Point to the left Point to the right Length Strength End of
No. Pull out resist.
x [m] z [m] x [m] z [m] L [m] Rt [kN/m] reinf.
7 9.76 -2.90 2.26 -2.90 7.50 15.67 Tp = 82.44 kN/m2 Fixed
8 9.80 -3.35 2.30 -3.35 7.50 15.67 Tp = 95.24 kN/m2 Fixed
9 9.84 -3.80 2.34 -3.80 7.50 15.67 Tp = 108.03 kN/m2 Fixed
10 9.87 -4.25 2.37 -4.25 7.50 15.67 Tp = 120.82 kN/m2 Fixed
11 9.91 -4.70 2.41 -4.70 7.50 15.67 Tp = 133.61 kN/m2 Fixed
12 9.95 -5.15 2.45 -5.15 7.50 15.67 Tp = 146.41 kN/m2 Fixed
13 9.98 -5.60 2.48 -5.60 7.50 15.67 Tp = 159.20 kN/m2 Fixed
14 10.02 -6.05 2.52 -6.05 7.50 15.67 Tp = 171.99 kN/m2 Fixed
15 10.05 -6.50 2.55 -6.50 7.50 15.67 Tp = 184.78 kN/m2 Fixed
16 10.09 -6.95 2.59 -6.95 7.50 15.67 Tp = 197.58 kN/m2 Fixed
17 10.13 -7.40 2.63 -7.40 7.50 15.67 Tp = 210.37 kN/m2 Fixed
18 10.16 -7.85 2.66 -7.85 7.50 15.67 Tp = 223.16 kN/m2 Fixed
19 10.20 -8.30 2.70 -8.30 7.50 15.67 Tp = 235.96 kN/m2 Fixed
20 10.24 -8.75 2.74 -8.75 7.50 15.67 Tp = 248.75 kN/m2 Fixed
21 10.27 -9.20 2.77 -9.20 7.50 15.67 Tp = 261.54 kN/m2 Fixed
22 10.31 -9.65 2.81 -9.65 7.50 15.67 Tp = 274.33 kN/m2 Fixed
23 10.34 -10.10 2.84 -10.10 7.50 15.67 Tp = 140.92 kN/m2 Fixed
24 10.38 -10.55 2.88 -10.55 7.50 15.67 Tp = 146.65 kN/m2 Fixed
25 10.42 -11.00 2.92 -11.00 7.50 15.67 Tp = 152.37 kN/m2 Fixed
26 -0.02 -0.25 7.48 -0.25 7.50 15.67 Tp = 7.11 kN/m2 Fixed
27 -0.06 -0.70 7.44 -0.70 7.50 15.67 Tp = 19.90 kN/m2 Fixed
28 -0.09 -1.15 7.41 -1.15 7.50 15.67 Tp = 32.69 kN/m2 Fixed
29 -0.13 -1.60 7.37 -1.60 7.50 15.67 Tp = 45.49 kN/m2 Fixed
30 -0.17 -2.05 7.33 -2.05 7.50 15.67 Tp = 58.28 kN/m2 Fixed
31 -0.20 -2.50 7.30 -2.50 7.50 15.67 Tp = 71.07 kN/m2 Fixed
32 -0.24 -2.95 7.26 -2.95 7.50 15.67 Tp = 83.86 kN/m2 Fixed
33 -0.27 -3.40 7.23 -3.40 7.50 15.67 Tp = 96.66 kN/m2 Fixed
34 -0.31 -3.85 7.19 -3.85 7.50 15.67 Tp = 109.45 kN/m2 Fixed
35 -0.35 -4.30 7.15 -4.30 7.50 15.67 Tp = 122.24 kN/m2 Fixed
36 -0.38 -4.75 7.12 -4.75 7.50 15.67 Tp = 135.04 kN/m2 Fixed
37 -0.42 -5.20 7.08 -5.20 7.50 15.67 Tp = 147.83 kN/m2 Fixed
38 -0.46 -5.65 7.04 -5.65 7.50 15.67 Tp = 160.62 kN/m2 Fixed
39 -0.49 -6.10 7.01 -6.10 7.50 15.67 Tp = 173.41 kN/m2 Fixed
40 -0.53 -6.55 6.97 -6.55 7.50 15.67 Tp = 186.21 kN/m2 Fixed
41 -0.57 -7.00 6.93 -7.00 7.50 15.67 Tp = 199.00 kN/m2 Fixed
42 -0.60 -7.45 6.90 -7.45 7.50 15.67 Tp = 211.79 kN/m2 Fixed
43 -0.64 -7.90 6.86 -7.90 7.50 15.67 Tp = 224.58 kN/m2 Fixed
44 -0.68 -8.35 6.82 -8.35 7.50 15.67 Tp = 237.38 kN/m2 Fixed
45 -0.71 -8.80 6.79 -8.80 7.50 15.67 Tp = 250.17 kN/m2 Fixed
46 -0.75 -9.25 6.75 -9.25 7.50 15.67 Tp = 262.96 kN/m2 Fixed
47 -0.78 -9.70 6.72 -9.70 7.50 15.67 Tp = 275.76 kN/m2 Fixed
48 -0.82 -10.15 6.68 -10.15 7.50 15.67 Tp = 141.56 kN/m2 Fixed
49 -0.86 -10.60 6.64 -10.60 7.50 15.67 Tp = 147.28 kN/m2 Fixed
50 -0.89 -11.05 6.61 -11.05 7.50 15.67 Tp = 153.01 kN/m2 Fixed
Water
Water type : No water
Tensile crack
Tensile crack not inputted.
Earthquake
Horizontal seismic coefficient : Kh = 0.49
Vertical seismic coefficient : Kv = 0.16
Settings of the stage of construction
Design situation : seismic
Results (Stage of construction 1)
Analysis 1
Circular slip surface
Slip surface parameters
x= -4.67 [m] 1 = -33.97 [°]
Center : Angles :
z= 0.02 [m] 2 = 89.92 [°]
Radius : R= 13.89 [m]
The slip surface after optimization.
The restrictions of points of circular slip surface
Keep the left end point of the slip surface
Keep the right end point of the slip surface
Reinforcement forces
Combination 1
Reinforcement Force [kN/m]
1 15.67
2 15.67
3 15.67
4 15.67
5 15.67
6 15.67
7 15.67
8 15.67
9 15.67
10 15.67
11 15.67
12 15.67
13 15.67
14 15.67
15 15.67
16 15.67
17 15.67
18 15.67
19 15.67
20 15.67
21 15.67
22 15.67
23 15.67
24 15.67
25 15.67
26 0.00
27 0.00
28 0.00
29 0.00
30 0.00
31 0.00
32 0.00
33 0.00
34 0.00
35 0.00
36 0.00
37 0.00
38 0.00
39 0.00
40 0.00
41 0.00
42 0.00
43 15.67
44 15.67
45 15.67
46 15.67
47 15.67
48 15.67
49 15.67
50 15.67
Combination 2
Reinforcement Force [kN/m]
1 15.67
2 15.67
3 15.67
4 15.67
5 15.67
6 15.67
7 15.67
8 15.67
9 15.67
10 15.67
11 15.67
12 15.67
13 15.67
14 15.67
15 15.67
16 15.67
17 15.67
18 15.67
19 15.67
20 15.67
21 15.67
22 15.67
23 15.67
24 15.67
25 15.67
26 0.00
27 0.00
28 0.00
29 0.00
30 0.00
31 0.00
32 0.00
33 0.00
34 0.00
35 0.00
36 0.00
37 0.00
38 0.00
39 0.00
40 0.00
41 0.00
42 0.00
43 15.67
44 15.67
45 15.67
46 15.67
47 15.67
48 15.67
49 15.67
50 15.67
Slope stability verification (Spencer)
Combination 1
Utilization : 79.6 %
Slope stability ACCEPTABLE
Combination 2
Utilization : 99.5 %
Slope stability ACCEPTABLE
Optimized slip surface for : Combination 2
Analiza globala
Analysis of reinforced slopes
Input data
Project
Task : ax bretea centura dreapta
Customer : IRIDEX
Author : LN
Date : 07-05-2018
Settings
Standard - EN 1997 - DA1
Materials and standards
Concrete structures : EN 1992-1-1 (EC2)
Coefficients EN 1992-1-1 : standard
Wall analysis
Active earth pressure calculation : Coulomb
Passive earth pressure calculation : Caquot-Kerisel
Earthquake analysis : Mononobe-Okabe
Shape of earth wedge : Calculate as skew
Allowable eccentricity : 0.333
Internal stability : Standard - straight slip surface
Verification methodology : according to EN 1997
Design approach : 1 - reduction of actions and soil parameters
Partial factors on actions (A)
Permanent design situation
Combination 1 Combination 2
Unfavourable Favourable Unfavourable Favourable
Permanent actions : G = 1.35 [–] 1.00 [–] 1.00 [–] 1.00 [–]
Variable actions : Q = 1.50 [–] 0.00 [–] 1.30 [–] 0.00 [–]
Water load : w = 1.35 [–] 1.00 [–]
dorosol
Unit weight : = 23.00 kN/m3
Angle of internal friction : ef = 22.00 °
Cohesion of soil : cef = 150.00 kPa
Angle of friction struc.-soil : = 13.00 °
Saturated unit weight : sat = 24.00 kN/m3
Argila prafoasa
Unit weight : = 19.03 kN/m3
Angle of internal friction : ef = 18.20 °
Cohesion of soil : cef = 33.00 kPa
Angle of friction struc.-soil : = 12.13 °
Saturated unit weight : sat = 22.00 kN/m3
Argilanisipoas
Unit weight : = 19.33 kN/m3
Angle of internal friction : ef = 16.10 °
Cohesion of soil : cef = 20.00 kPa
Angle of friction struc.-soil : = 10.73 °
Saturated unit weight : sat = 22.00 kN/m3
1 9.70 Umpluturi
3 1.00 dorosol
6 3.00 Argilanisipoas
7 - Argilanisipoas
Water influence
Ground water table is not considered.
1 9.70 Umpluturi
3 1.00 dorosol
6 3.00 Argilanisipoas
Layer
No. Assigned soil Pattern
[m]
7 - Argilanisipoas
Water influence
Ground water table is not considered.
Earthquake
Factor of horizontal acceleration Kh = 0.4860
Factor of vertical acceleration Kv = 0.1600
Settings of the stage of construction
Design situation : seismic