Flame Ionization Detector (FID) principle | Cambustion http://www.cambustion.

com/products/hfr500/fast-fid-principles

This site uses cookies, click here for more details. Dismiss this message or follow any link to continue.

Home (/) / Products (/products) / Fast Engine Gas Analyzers (/products/gas)


/ Fast HC Analyzer (/products/hfr500) / Fast FID Principles

Fast FID Principles

The flame ionisation detector (FID) is the automotive emissions industry standard
HFR500 Fast FID
method of measuring hydrocarbon (HC) concentration.
description
(/products/hfr500)

HFR400
atmospheric fast
FID (/products
/hfr400)

FID applications
and sample data
(/applications
/appinst/HFR500)

Brochure and
specifications
(/sites/default/files
/instruments
/HFR500
/Cambustion500seriesgasanalyzers.pdf

The sample gas is introduced into a hydrogen flame inside the FID. Any hydrocarbons
CLD principle
in the sample will produce ions when they are burnt. Ions are detected using a metal
(/products/cld500
collector which is biased with a high DC voltage. The current across this collector is
/cld-principles)
thus proportional to the rate of ionisation which in turn depends upon the
concentration of HC in the sample gas.
NDIR principle
(/products/ndir500 The ionisation process is very rapid, so the slow time response of conventional FIDs
/operating-principle) is mainly due to sample handling. A typical slow analyser might have a response time
of 1-2 seconds.

The Cambustion HFR fast response FID analyzers use conventional detection
principles and a unique patented sampling system to give millisecond response times.