Descript PDF
Descript PDF
http://ocw.mit.edu
Spring 2008
For information about citing these materials or our Terms of Use, visit: http://ocw.mit.edu/terms.
Massachusetts Institute of Technology
Introduction: This handout describes the major components of the components of the
2.004 laboratory work stations.
Computer: The computer is a Micron 2.2 GHz PC with 1 Gbyte of RAM, and 40 Gbytes
of hard disk. The computers are configured as part of the ME domain, and share a networked
printer in the laboratory. Each computer contains a National Instruments M-series PCI-6221
high performance data acquisition and control card, that allows sampling of 16 channels of
16 bit data, at sampling rates up to 250 ksamples/sec. The cards have two digital-analog
converters (DAC). This board also has digital input and output capability, although we will
not use these features in 2.004. Communication with the computer is via a BNC terminal
box (National Instruments BNC-2090).
The operating system is Windows XP Pro (SP 2). The computers are deliberately kept in
a “locked-down” state. You will be given access to all of the resources necessary to complete
the labs, but you will not be able to make customizations or modifications to the operating
system.
Logging on to the Computers: The 2.004 computers are configured as part of the Me
chanical Engineering domain. Each lab group will have an account for this course. Your
home directory will appear as drive z:. Your account, and any files you create during the
lab, will be accessible from any Mechanical Engineering computer.
Software: The following software packages are installed and available for use:
• Microsoft Office 2003, including Microsoft Word, Excel, Access, PowerPoint.
• Internet Explorer 6
• Matlab 7.0, including Simulink and the following toolboxes: Control Systems, Signal
Processing, System Identification, Nonlinear Control, Robust Control, Optimization,
Wavelet, Partial Differential Equations and StateFlow.
• Maple 9.5 or 10.
• National Instruments LabVIEW 8.0 Professional, with full development facilities and
all toolkits.
• National Instruments Signal Express.
In addition there are a set of specialized software packages developed for 2.004, including a
set of virtual instruments (a computer based chart recorder, a spectrum analyzer, and a set
of digital controllers) written in LabVIEW 8.0.
Laboratory Hardware: The following instrumentation is provided at each work-station.
• Power Supply: You are provided an instrumentation quality power supply (Tektronix)
that can be used as a reference input or to power external equipment.
• Servo motor Power amplifier The servo power amplifier contains an Aerotech 4020-LS
linear power amplifier configured in a VCCS (voltage controlled current source) mode.
The ratings of this amplifier are output voltage of ±40 volt, and a peak current of
±20 amps (for less than 2 seconds), and a sustained maximum current of ±5 amps.
The internal amplifier has been modified slightly to reduce its gain, and calibrated to
a gain of 2 amp/volt. Internal buffered amplifiers have been installed to monitor the
load voltage and current.
• “Proto” Boards In some of the experiments you will be required to build analog con
trollers using electronic operational amplifiers. Each lab group will be given a proto
board on which to construct their circuits. The board can be stored from week-to-week.
Each lab-station will have a power supply to operate the boards.
In the interests of safety, security, and to minimize the risk of damage to the equipment we
must insist that the following rules be observed:
• Unsupervised student access to the laboratory is not allowed. There must be present
a faculty member, teaching assistant, or a designated supervisor at all times,
• No equipment or components are to be removed from the laboratory at any time. This
includes a ban on all lending of equipment to research groups.
• No external equipment (other than that provided within the laboratory) is to be con
nected to the computers or power amplifiers without the express permission of the
faculty member in charge.
• The laboratory work area is to be left clean and tidy at the end of each session. Cables
and components must be returned to their drawers and racks, all unwanted/damaged
components should be placed in the trash cans, and the desk left clean and neat.
• No software is to be installed on any of the lab computers without the express permis
sion of the faculty member in charge.