Pipeline Sizing Formula For Piping Sizing

This document provides a formula and table for sizing pipes based on flow rate, pressure, and velocity. The formula shown is DN (mm) = 18.81 SQ.RT.(Q/(P*v)), where DN is pipe size, Q is flow rate in scmh, P is pressure in bar(g) or bar(abs), and v is velocity in m/s. The table applies this formula to calculate the theoretical and actual pipe sizes in mm for inlet and outlet pipes of two types with varying flow rates, pressures, and velocities.

Uploaded by

Ram Sudheer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views

Pipeline Sizing Formula For Piping Sizing

This document provides a formula and table for sizing pipes based on flow rate, pressure, and velocity. The formula shown is DN (mm) = 18.81 SQ.RT.(Q/(P*v)), where DN is pipe size, Q is flow rate in scmh, P is pressure in bar(g) or bar(abs), and v is velocity in m/s. The table applies this formula to calculate the theoretical and actual pipe sizes in mm for inlet and outlet pipes of two types with varying flow rates, pressures, and velocities.

Uploaded by

Ram Sudheer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

PIPELINE SIZING

FORMULA FOR
DN (in mm) = 18.81 SQ. RT. (Q / (P * v))
PIPING SIZING:
flow Pressure Velocity pipe size
Q (scmh) P (bar (g)) P (bar (abs)) v (m/s) DN (mm) Actual DN (mm)
TYPE I (INLET) 100 4 5.013 20 18.7855945803 20
TYPE I
100 0.1 1.113 40 28.1910477848 40
(OUTLET)

TYPE II (INLET) 100 1 2.013 20 29.6450310989 40


TYPE II
100 0.5 1.513 40 24.1790557087 25
(OUTLET)
DN (inches)
3/4"
1 1/2"

1 1/2"
1"