Replacement Boiler Sizing Chart: Standing Radiation

This document provides a boiler sizing chart to help determine the appropriate size for a replacement boiler. It includes tables for calculating the heating requirements based on the type of heating system (steam or hot water), fuel type, existing boiler information, and square footage of different types of radiators (standing, baseboard, column, tube, wall). Conversion factors are provided to calculate the total BTUH load from the radiator square footage.

Uploaded by

vivek mishra
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
155 views

Replacement Boiler Sizing Chart: Standing Radiation

This document provides a boiler sizing chart to help determine the appropriate size for a replacement boiler. It includes tables for calculating the heating requirements based on the type of heating system (steam or hot water), fuel type, existing boiler information, and square footage of different types of radiators (standing, baseboard, column, tube, wall). Conversion factors are provided to calculate the total BTUH load from the radiator square footage.

Uploaded by

vivek mishra
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Replacement Boiler Sizing Chart

Type of System Steam Forced Hot Water


Type of Fuel Oil Natural Gas
Brand Name of Present Boiler
Model Number
Boiler Input (BTUH)
Square Feet of Radiation
Output (Heating Capacity - BTUH)

Standing Radiation
Sq Ft. Per Section
Room (see Standing Radiation Tab) x Number of Sections =
x =
x =
x =
x =
x =
x =
x =
x =
x =
x =
x =
x =
Total Sq Ft. of Radiation
Conversion Factor (see below) x
Total BTUH Load

Conversion Factors
1 sq. ft. of steam radiation = 240 Net BTUH
1 sq. ft. of forced hot water = 185 Net BTUH at 190ºF
Gravity Hot Water
LPG

Baseboard Radiation
Lineal Feet
Radiation in Sq. Ft. (Length of Finned Tube Only)
0
0
0
0
0
0
0
0
0
0
0
0
0 Total Linear Feet 0
x 600 BTU/Ft. 600
0 Total BTUH Load 0
Column Type Radiators
Sq. Ft. Radiation Per Section
Height One Two Three Four Window
(Inches) Column Column Column Column
13 --- --- --- --- 3
16 --- --- --- --- 3-3/4
18 --- --- 2-1/4 3 4-1/4
20 1-1/2 2 --- --- 5
22 --- --- 3 4 ---
23 1-2/3 2-1/3 --- --- ---
26 2 2-2/3 3-3/4 5 ---
32 2-1/2 3-1/3 4-1/2 6-1/2 ---
38 3 4 5 8 ---
45 --- 5 6 10 ---

Tube Type Radiators


Sq. Ft. Radiation Per Section
Window
Height Three Four Five Six Seven
(Inches) Tube Tube Tube Tube Tube
14 --- --- --- --- 2-1/2
17 --- --- --- --- 3
20 1-3/4 2-1/4 2-2/3 3 3-2/3
23 2 2-1/2 3 3-1/2 ---
26 2-1/3 2-3/4 3-1/2 4 4-3/4
32 3 3-1/2 4-1/3 5 ---
38 3-1/2 4-1/4 5 6 ---

Wall Type Radiators


Sq. Ft. Radiation Per Wall Radiator Section
Heating
Type of Height Length Thickness Sq. Ft.
Section (Inches) (Inches) (Inches) Radiation
5-A 13-5/16 16-5/8 2-7/8 5
7-A 13-5/16 21-7/8 2-7/8 7
7-B 21-7/8 13-3/16 3-1/16 7
9-A 18-5/16 29-1/16 2-7/8 9
9-B 29-1/16 18-5/16 3-11/16 9