0% found this document useful (0 votes)
694 views

Slab Design Excel

The document provides design details for two slabs (S1 and S2) according to IS:456-2000. Slab S1 is a 150mm thick two-way interior panel slab with 10mm main bars spaced at 100-150mm. Slab S2 is a 125mm thick one-way slab with 8mm bars spaced at 150mm. It also includes the design of a 2.2m walkway slab with 12mm main bars at 175mm effective depth to resist a factored load of 9kN/m^2.

Uploaded by

sahmedu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
694 views

Slab Design Excel

The document provides design details for two slabs (S1 and S2) according to IS:456-2000. Slab S1 is a 150mm thick two-way interior panel slab with 10mm main bars spaced at 100-150mm. Slab S2 is a 125mm thick one-way slab with 8mm bars spaced at 150mm. It also includes the design of a 2.2m walkway slab with 12mm main bars at 175mm effective depth to resist a factored load of 9kN/m^2.

Uploaded by

sahmedu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 6

DESIGN OF SLAB AS PER IS:456-2000

latest 28/4/06

BUILDING NAME DPC SLAB S2


SHORT SPAN (mt) Lx 3.20 CONCRETE GRADE M- 20
LONG SPAN (mt) Ly 8.00 STEEL GRADE Fe - 415
SLAB THICKNESS (mm) - D 125 LOAD FACTOR ( L.S.D ) 1.2
LOADS
DEAD LOAD ( KN/Sq.mt ) 3.13 WIDTH OF SLAB ( mm ) B 1000
FINISHES ( KN/Sq.mt ) 2.50 CLEAR COVER ( mm ) 20
LIVE LOAD ( KN/Sq.mt ) 2.00 DIA OF MAIN STEEL ( mm ) 8
DIA OF DIST. STEEL ( mm ) 8
TOTAL LOAD(KN/Sq.mt) 7.63 EFFECTIVE THICKNESS ( mm ) -d 101

B.M COEFFICIENTS:
EDGE CONDITION : CASE 3 ONE LONG EDGE DISCONTINUOUS
AVERAGE MAXIMUM B.M w*Lx*Lx/10
RATIO OF LONG/SHORT SPAN 2.50 ONE-WAY SLAB
FACTORED B.M (KN.M) (KN.mt)
( -VE ) COEFFT. ALONG Lx 0.000 ( -VE ) B.M ALONG Lx 0.00
( +VE ) COEFFT. ALONG Lx 0.100 ( +VE ) B.M ALONG Lx 9.37
( - VE ) COEFFT. ALONG Ly 0.000 ( - VE ) B.M ALONG Ly 0.00
( +VE ) COEFFT. ALONG Ly 0.000 ( +VE ) B.M ALONG Ly 0.00
AREA OF STEEL REQUIRED ( Sq.mm ) SPACING OF STEEL REQUIRED ( mm )
MAX. SPACING AS PER IS-456 303
MINIMUM STEEL AS PER IS-456 150 SPACING OF MINIMUM STEEL 335
( -VE ) STEEL ALONG Lx 150 ( -VE ) STEEL ALONG Lx 303
( +VE ) STEEL ALONG Lx 272 ( +VE ) STEEL ALONG Lx 185
( -VE ) STEEL ALONG Ly 150 ( -VE ) STEEL ALONG Ly 303
( +VE ) STEEL ALONG Ly 150 ( +VE ) STEEL ALONG Ly 303

AREA OF STEEL PROVIDED ( Sq.mm ) SPACING OF STEEL PROVIDED ( mm C/C )

( -VE ) STEEL ALONG Lx 335 ( -VE ) STEEL ALONG Lx 150


( +VE ) STEEL ALONG Lx 335 ( +VE ) STEEL ALONG Lx 150
( -VE ) STEEL ALONG Ly 335 ( -VE ) STEEL ALONG Ly 150
( +VE ) STEEL ALONG Ly 335 ( +VE ) STEEL ALONG Ly 150

CHECK FOR DEFLECTION:

BASIC L/d RATIO 26


Provided.(+) ve pt.(IN SHORTER 0.33 THEORITICAL MODIFICATION FACTOR AS
SPAN) PER SP-24 1.45
Reqd.(+) ve pt.(IN SHORTER Permissible L/d ratio
SPAN) 0.27 39.71
EFF.DEPTH REQUIRED - d (mm) 81 EFF. DEPTH PROVIDED - d ( mm ) 101
HENCE DESIGN OF SLAB IS SAFE
cont..SLAB S2

SUMMARY OF SLAB :
. SPACING OF STEEL PROVIDED (c/c) ( mm )
GRADE OF CONCRETE M 20 ( -VE ) STEEL ALONG SHORT SPAN 150
GRADE OF STEEL Fe 415 ( +VE ) STEEL ALONG SHORT SPAN 150
THICKNESS OF SLAB ( mm ) 125 ( -VE ) STEEL ALONG LONG SPAN 150
DIA OF MAIN STEEL ( mm ) 8 ( +VE ) STEEL ALONG LONG SPAN 150
DIA OF DIST STEEL ( mm ) 8 No. OF EXTRA BARS OVER SUPPORTS 2

PROVIDE #8 @ 150 mm. c/c


2No.s BARS OF #8 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

LX

LY

PROVIDE #8 @ 150 mm. c/c


2No.s BARS OF #8 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

SLAB S2
DESIGN OF SLAB AS PER IS:456-2000
latest 28/4/06

BUILDING NAME DPC SLAB S1


SHORT SPAN (mt) Lx 4.69 CONCRETE GRADE M- 20
LONG SPAN (mt) Ly 6.06 STEEL GRADE Fe - 415
SLAB THICKNESS (mm) - D 150 LOAD FACTOR ( L.S.D ) 1.5
LOADS
DEAD LOAD ( KN/Sq.mt ) 3.75 WIDTH OF SLAB ( mm ) B 1000
FINISHES ( KN/Sq.mt ) 1.00 CLEAR COVER ( mm ) 20
LIVE LOAD ( KN/Sq.mt ) 10.00 DIA OF MAIN STEEL ( mm ) 10
DIA OF DIST. STEEL ( mm ) 8
TOTAL LOAD(KN/Sq.mt) 14.75 EFFECTIVE THICKNESS ( mm ) -d 125

B.M COEFFICIENTS:
EDGE CONDITION : CASE 1 INTERIOR PANEL
B.M. COEFFICIENTS AS PER TABLE 26 OF IS:456-2000
RATIO OF LONG/SHORT SPAN 1.29 TWO-WAY SLAB
FACTORED B.M (KN.M) (KN.mt)
( -VE ) COEFFT. ALONG Lx 0.046 ( -VE ) B.M ALONG Lx 22.33
( +VE ) COEFFT. ALONG Lx 0.035 ( +VE ) B.M ALONG Lx 16.91
( - VE ) COEFFT. ALONG Ly 0.033 ( - VE ) B.M ALONG Ly 16.18
( +VE ) COEFFT. ALONG Ly 0.025 ( +VE ) B.M ALONG Ly 12.17
AREA OF STEEL REQUIRED ( Sq.mm ) SPACING OF STEEL REQUIRED ( mm )
MAX. SPACING AS PER IS-456 375
MINIMUM STEEL AS PER IS-456 180 SPACING OF MINIMUM STEEL 437
( -VE ) STEEL ALONG Lx 544 ( -VE ) STEEL ALONG Lx 144
( +VE ) STEEL ALONG Lx 402 ( +VE ) STEEL ALONG Lx 196
( -VE ) STEEL ALONG Ly 383 ( -VE ) STEEL ALONG Ly 131
( +VE ) STEEL ALONG Ly 283 ( +VE ) STEEL ALONG Ly 178

AREA OF STEEL PROVIDED ( Sq.mm ) SPACING OF STEEL PROVIDED ( mm C/C )

( -VE ) STEEL ALONG Lx 786 ( -VE ) STEEL ALONG Lx 100


( +VE ) STEEL ALONG Lx 524 ( +VE ) STEEL ALONG Lx 150
( -VE ) STEEL ALONG Ly 503 ( -VE ) STEEL ALONG Ly 100
( +VE ) STEEL ALONG Ly 335 ( +VE ) STEEL ALONG Ly 150

CHECK FOR DEFLECTION:

BASIC L/d RATIO 26


Provided.(+) ve pt.(IN SHORTER 0.42 THEORITICAL MODIFICATION FACTOR AS
SPAN) PER SP-24 1.34
Reqd.(+) ve pt.(IN SHORTER Permissible L/d ratio
SPAN) 0.33 39.10
EFF.DEPTH REQUIRED - d (mm) 120 EFF. DEPTH PROVIDED - d ( mm ) 125
HENCE DESIGN OF SLAB IS SAFE
cont..SLAB S1

SUMMARY OF SLAB :
SPACING OF STEEL PROVIDED (c/c) ( mm )
GRADE OF CONCRETE M 20 ( -VE ) STEEL ALONG SHORT SPAN 100
GRADE OF STEEL Fe 415 ( +VE ) STEEL ALONG SHORT SPAN 150
THICKNESS OF SLAB ( mm ) 150 ( -VE ) STEEL ALONG LONG SPAN 100
DIA OF MAIN STEEL ( mm ) 10 ( +VE ) STEEL ALONG LONG SPAN 150
DIA OF DIST STEEL ( mm ) 8 No. OF EXTRA BARS OVER SUPPORTS 2

PROVIDE #8 @ 150 mm. c/c


2No.s BARS OF #8 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

LX

LY

PROVIDE # 10 @ 150 mm. c/c


2No.s BARS OF # 10 EXTRA OVER SUPPORTS
BETWEEN TWO CRANKED BARS

SLAB S1
Design of walk Way slab

Span of the slab = 2.200 m

Thickness of the at support = 0.20 m

Thickness of the at free end = 0.20 m

Grade of steel = M 20

Grade of concrete = 415 N / mm 2

Live load on the slab = 3.00 Kn / m 2

Floor finishing = 1.00 Kn / m 2

Width of the slab = 1000 mm

Effective depth = 175.0 mm

Diameter of main bar = 12 mm

Diameter of distribution bar = 8 mm

Load on slab :

Dead load = ( 0.2 + 0.2 ) x 0.5 x 25 = 5

Live load = 3.00

Floor finishing = 1.00

9.00 Kn / m 2

Bending moment = 1.5 x 9 x 2.2 ^ 2


2
= 32.670 Kn - m
Minimum area of steel required as per IS-456 = 210.0 mm 2
( 0.12% of crossectional area )

Area of steel required from BM consideration = 553.67 mm 2

Max spacing required as per IS-456 = 450.0 mm

Spacing required for minimum steel = 538.8 mm

Spacing required for BM consideration = 204.4 mm

Spacing of main steel provide = 125 mm

Area of main steel provided = 905.1 mm 2

Distribution steel :

Spacing required = 239.46 mm

Provide distribution steel spacing = 200 mm

Check for Deflection :

Basic L/d Ratio = 7

Percentage of steel provided = 0.52

Percentage of steel required = 0.32

Permissible L/d ratio = 12.58

Effective depth required = 174.94 mm

Effective depth provided = 175.0 mm Hence safe