0% found this document useful (0 votes)
26 views

2 LP06 60deg W5C

This flaw detecting report from July 31, 2015 details an inspection of an LP heater part that found a flaw 37.8 mm from the sound path with a projection of 32.7 mm and depth of 13.1 mm using an MFD500B instrument and dual element probe. The inspection found and reported a flaw in the part.

Uploaded by

Sanjaya Perera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
26 views

2 LP06 60deg W5C

This flaw detecting report from July 31, 2015 details an inspection of an LP heater part that found a flaw 37.8 mm from the sound path with a projection of 32.7 mm and depth of 13.1 mm using an MFD500B instrument and dual element probe. The inspection found and reported a flaw in the part.

Uploaded by

Sanjaya Perera
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 2

FLAW DETECTING REPORT

DATE&TIME: 7/31/2015 ### PAGE NO:

CLIENT REPORT NO
EXECUTOR TEST LOCATION
PART NAME LP HEATER 06 COVERAGE
PART NO. W5C TEST TIMING
PART SIZE REF. STANDARD
MATERIAL ACCEPT LEVEL
TEST SURFACE FLAW INFORMATION
HEAT PROCESS DISTANCE 37.8 mm
COUPLANT PROJECTION 32.7 mm
INSTRUMENT MFD500B H-AXIS SOUND PATH FLAW DEPTH 13.1 mm
PROBE NO. 60889 PRB TYPE DUAL ELEMENTDB OFFSET
XTAL FREQ 4.00 MHz X-VALUE 0.0 mm FLAW LENGTH
PROBE ANGLE 60.0 Deg. FLAW HEIGHT
GAIN 47.5 dB+0.0 dB+0.0 dB TEST CLASS
FLAW ECHO

RESULT:

OPERATOR DATE&TIME

SIGNATURE DATE&TIME