The document describes power factor and phase angle meters that comply with various industry standards. The meters can measure single or three phase systems with 2, 3, or 4 wires and have high accuracy of 0.5% with an LED display. They are designed to withstand overloads and surges while providing reliable operation across a wide temperature and voltage range.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
67 views

MP PDF

The document describes power factor and phase angle meters that comply with various industry standards. The meters can measure single or three phase systems with 2, 3, or 4 wires and have high accuracy of 0.5% with an LED display. They are designed to withstand overloads and surges while providing reliable operation across a wide temperature and voltage range.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Power Factor & Phase Angle Meters

Featrues
True power system design compliants
ANSI-IEEE, IEC & VDE standards
High over capability to assure reliable operation
High accuracy 0.5%
Display with super rate LED
Applied rules & standards
Measuring & conversion IEC 688
Dielectric strenth IEC 688
Impulse & Surge test ANSIc37.90/1989, IEC 255-3
Adaptability=powersystm IEC 0110
Measuring reliability VDE 3540
Specification
Model MP & ML Power factor and Phase angle meters, designed of a balance type with universal & flexible application
feature, can be applied to measure single phase 2 or 3 wires, 3 phase 3 wires & 3 phase 4 wires only under the
specified terminal connection. The units accept ac voltage & current inputs with detection of phase relation between the
measured phase voltage & phase current of power factor COSØ for MP & phase angle for ML. The designed specifica-
tions compliant ANSI, DIN & VDE standards with full protection for unusual surge intrusion and input over assuring
reliable operation.
Specification
Accuracy (23± 3°C) 0.5%fs + 0.2° > 20% input current, 0.5%fs + 0.4° >10% input current
Stability Temperature coefficient <50 ppm per degree c, long term draft <0.2% per year
Display & resolution 0.56” super rate LED, 0.001-0.999 for PF, 0.010-360.0 degree for phase angle
Response time Sample rate 1 of per sec. typically
Input over Current input:3xrating-continuous, 10x rating-30 sec., 25x rting-3 sec.
Voltage input : max continuous 750V or 1.5 rating which ever great
Frequency 47-70 Hz
Dielectric strength 2.5KVrms/1 min, all terminals to case, 2KVrms/1 min input vs power terminals
Surge test ANSI C37.90/1989, IEC 255-3 (1989)
Impulse Voltage 1.2x50us 4KV, oscillation wave 0.5us-100KHz 3KV or 1Mhz-0.25 ms 2.5KV
operating condition Temperature range -10 to 55°C, 0-99% RH non-condensed, storage -25 to 70°C
Auxiliary poer AC ± 15% < 6 VA DC ±20% < 6 watt
Order form
System Function Models
1 phase 2 wires Power Factor MP
3 phase 3 wires
3 phase 4 wires Phase Angle ML
Frame ( in mm)
96x48 U
110x110 O
Auxiliary power
AC 110 V & 220V S
DC Option 12 V 1
DC Option 24 V 2
DC Option 48 V 3
DC Option 125 V 4
Voltage & Current Input
Defined range Effective rang
75-135V/0.5-5A 50-160V/0.2-0.75A 1 50-300V A
180-500V/0.5-5A 150-600V/0.2-7.5A 2 100-500V B
75-135V/0.1-1A 50-160V/0.05-1.5A 3 V-V input for phase angle
180-500V/0.1-1A 150-600V/0.05-1.5A 4 only
90-300V/2-20A 60-330V/0.5-25A 5
180-500V/2-20A 150-600V/0.5-25 6
Terminal connection........... Model MP / ML
Terminals 11(+),12(-),for DC power option

1phase 2 wires 3 phase 3 wires

Ms MI Pm Pn As AI Cs Cl P a Pb Pc

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
m n AC110V a b c AC110V
AC 220V AC 220V
Aux. Power Aux. Power
M A
N B
Source Load C
Source Load

3 phase 4 wires Ousi 3 phase 4 wires

As AI Bs BI Cs CI P a Pb Pc Pn As AI Bs BI Cs CI P a Pn

1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12
a b c n AC110V a n c AC110V
AC 220V AC 220V
Aux. Power Aux. Power
A A
B B
C C
N Source Load N Source Load

V - V input for phase angle only

+ - + -
1 2 3 4 5 6 7 8 9 10 11 12
V1 V2 AC110V
AC 220V
Aux. Power