Experiment 7 ET 332b No-Load and Starting Characteristics of Squirrel-Cage Induction Motors Purpose
Experiment 7 ET 332b No-Load and Starting Characteristics of Squirrel-Cage Induction Motors Purpose
ET 332b
No-load and Starting Characteristics of Squirrel-Cage Induction Motors
Purpose:
Determine the electrical and mechanical characteristics of a squirrel-cage induction motor during
no-load and start-up operation through lab measurements and calculations.
Theoretical Background
A squirrel-cage induction motor consists of two parts: the stator and the rotor. There is no
electrical connection between the rotor and stator. The magnetic flux produced by the stator
provides power transfer across the air gap without any electrical connection. This makes the
squirrel-cage induction motor a rugged machine for industrial applications
Applying three phase voltages to the motor stator produces a rotating magnetic field. The field’s
rotational speed depends on the voltage frequency and the number of magnetic poles in the
motor design. The variable, ns, synchronous speed, defines the speed of the rotating magnetic
field. The rotating magnetic field induces a voltage in the squirrel-cage rotor bars. The induced
voltage produces a current in the rotor bars since the squirrel-cage forms a complete circuit.
At startup, the induced rotor voltage has maximum frequency since the slip speed is equal to the
synchronous speed. The induced voltage has maximum magnitude also since the relative speed
between the rotor and the rotating field is greatest. Equation (1) gives the relationship between
rotor frequency and slip.
f r fs s (1)
The motor slip is nearly zero when the squirrel-cage motor operates without mechanical load
connected to the shaft. This produces a very low rotor frequency. The rotor leakage reactance
magnitude varies with the rotor frequency based on equation (2)
x r 2f r Lr (2)
This equation shows that the rotor leakage reactance is maximum when the motor starts since fr =
fs.
Figure 1 shows a schematic per-phase circuit representation of the rotor-stator circuit. The rotor
resistance is a function of the motor slip, which relates to the mechanical load on the motor. The
motor slip changes from 1 at start up to nearly zero for no-load. This causes the rotor resistance
xr
Ife Im Rr/s
Rfe xm EBRs
VL
Rotor Circuit Ir
At no-load, the current flowing in the rotor, Ir, is small since the induced voltage is very low and
rotor resistance is high. Most of the current entering the motor goes to the stator circuit to
produce the magnetization current that forces flux across the air gap. The value of xm in Figure 1
represents the magnetization reactance that draws the current Im. Active power losses in the iron
cores of the motor draw core loss current, Ife. The resistor, Rfe, represents the power losses in the
core in the motor model.
Squirrel-cage induction motors draw a large lagging current at no-load since the magnetic circuit
includes an air gap. Most of the current goes to Im, since xm is much smaller than Rfe. The
resulting power factor of the unloaded induction motor is very low (0.2-.5) due to the large
magnetization current component.
The induced rotor voltage EBR is at a maximum when the motor starts. The rotor resistance is
minimum, and the inductive reactance is maximum because slip is 1 at start-up. This
combination of factors produces rotor impedance that is highly inductive and low in value
relative to the no-load rotor impedance. This produces a high rotor current that is reflected to the
stator due to transformer action. This current is seven to ten times the motor rated current
typically. The large inductive component of the rotor impedances gives the rotor a low power
factor during start-up.
The rotor current is directly proportional to stator voltage and inversely proportional to rotor
impedance. The stator voltage also affects the motor torque. Motor torque is proportional to the
strength of the stator magnetic field, which depends on stator voltage. Equation 3 gives the
relationship between the rotor current, power factor, field flux and torque. Increasing the rotor
resistance increases motor torque.
Since current and flux are both proportional to the applied voltage, VL, in Figure 1, the following
equation shows that the starting torque is proportional to the square of the applied voltage.
A motor starting torque test utilizing reduced terminal voltage can use Equation 4 to find the
value of starting torque for rated terminal voltage. Reducing the terminal voltage by half reduces
the starting torque by a factor of four. Reducing the terminal voltage lowers the motor line
current during the test allowing measurement to be made before circuit breakers trip due to high
starting currents.
Testing three-phase induction motors requires three-phase power measurement. The two-
wattmeter method can measure total three-phase power by using two single-phase wattmeters.
Figure 2 shows the connects for this method using an ABC phase sequence.
P1= VacIacos(30-)
Meter 1
A
I-coil
V-coil
C Motor
V-coil
I-coil
Meter 2
P2= VbcIbcos(30+)
The total motor power is the algebraic sum of the meter readings. The meter readings also give
the total reactive power consumed and the load power factor by using Equations 5-7 below.
These equations are correct for ABC phase sequence.
For a BAC phase rotation with the same meter connections, equations (6) and (7) become:
3 P2 P1
Load power factor: tan 1
P1 P2
The equations above show variables P1 and P2 exchanged in the differences of the two equations
when using BAC phase sequence.
Performance Objectives
After successfully completing this lab, the student will be able to:
Required Equipment
Program Plan
Step 1: Place the IM-100 induction machine on the bedplate and clamp the machine
securely.
0-600 W
L2 L2
B P1
0-600 W
L1 L1 0-8 A
A A P2
B
L3 L3
C
V
Stator Rotor
0-300 V
A C
B
I-coil
P1
V-coil
A Motor
I-coil
P2
V-coil
C
Figure 4. Power meter connection details. Dotted end of coils indicates positive terminals.
Step 3: Find the induction motor nameplate and record the rated speed, voltage,
current and horsepower in Table 1 on the Data Tables and Calculations
Summary sheet.
Step 4: Move the voltmeter connections to the terminals of the bench supply.
Turn on the bench power supply and adjust the output voltage to rated
motor voltage. Replace the voltmeter leads to the position in Figure 3.
Step 6: Measure the no-load motor speed using the strobe tachometer. Record the
measurement in Table 3.
Step 7: Turn the motor off. Turn the bench power off.
Step 1: Install the pony brake on the bedplate and couple it to the motor using the
rubber coupling. Clamp the pony brake securely and place shaft guards on
all rotating shafts.
Step 2: Move the voltmeter leads from the motor to the bench power supply. Turn
on the supply and adjust the supply voltage to 104 V. Turn off the supply
and replace the leads in the position shown in Figure 3.
Step 3: Loosen the pony brake tension strap by adjusting the knob located on top
of the device (See photo ). Loosen the brake until the shaft turns freely.
Step 4: Find the force scale and check the zero position. Adjust the zero position
as necessary by pulling the metal tab located on the top of the scale.
Step 6: Complete this step as quickly as possible because the motor will draw a
large current at locked rotor and will eventually trip the breaker on the
motor front panel. Tighten the pony brake until the motor shaft stops.
Record the motor current, voltage and power readings. Record the scale
force value in grams. Enter all these values in Table 4. Power the motor
down using the breaker switch. (Note: Allow the motor to cool and reset
it if it trips before all measurements are taken again.
Step 7: Wait 2-5 minutes for the motor and breaker to cool and repeat step 6 two
more times to complete Table 4.
Step 8: Turn off the motor and the bench power supply. Remove all wiring and
return test items to storage.
1. The total three phase power is the algebraic sum of the P1 and P2 measurements. Add
any negative value to find the net power. Record the value below.
PT = ________________
2. Compute the total apparent power entering the motor using the following formula and
record the result below.
ST 3 VL I L (8)
ST = ________________
3. The ratio of motor active power to apparent power gives the no-load motor power factor.
This value should be low since the motor draws a large reactive current to establish the
flux in the air gap with little active power transfer. Compute the value and enter it below.
PT
Fp = _______________ Lagging
ST
ns n r
s = ________ p.u.
ns
1. Compute the average line current values using the measurement in Table 4 and enter it in
the last row of the table.
2. The experiment uses half the rated terminal voltage when conducting the starting torque
test. Full voltage starting current will be twice the average test value from Table 4.
Compute this value and enter it in the first row of Table 5.
3. Compute the torque values for each test measurements in Table 4 using the following
equation:
F
T (N - m) d
101.972 gm/N
4. Motor torque is proportional to the square of the applied voltage. Stated as proportions
this becomes:
T1 V12
T2 V22
The experimental measurements are made using half voltage so starting torque at rated
voltage is 4 times the average from Table 4.
T2 4 T1
Compute this value and enter it into the first row of Table 5.
7124 HP
T (N - m)
nr
6. Compute the ratio of starting current to full load (rated) current and multiply it by 100%
to determine the percentage of rated current. (Typical 400-700%). Compute the ratio of
starting torque to full load (rated) torque and multiply by 100% to determine percentage
of rated torque. (Typical 200-250%) Enter both these values in row 3 of Table 5.
7. Compute the reduced voltage starting apparent power using Equation (8) from step 2 of
this section. Use the average current and voltage values from Table 4. Enter the
computed result below.
STR = _____________ VA
8. Compute the average total power and enter it in Table 4. Compute the rotor power factor
by dividing the average total power by STR from step 7. Enter the result below.
Fp = ____________
9. Find the power factor angle of the rotor using the following formula and enter the result
below.
cos 1(Fp )
= __________
Quick Quiz
4. You would get more N-m of starting torque from each amp of starting current if:
Write a 1-2 page double spaced discussion that answers the following questions. Do not repeat
the question. Write paragraphs that address these topics using correct grammar and spelling.
1.) Explain how the induced voltage in the rotor of an induction motor changes as the rotor
speed changes.
2.) Show the per-phase schematic model of an induction motor and explain why the rotor current
stays almost constant while the rotor power factor changes.
3.) Explain the relationship between stator terminal voltage and motor torque.
4.) Draw the connections for the two-wattmeter method of measuring active power. How is
power factor found from the power measurements? Use both words and formulas to explain
the process.