The document describes a relay output module called SM 322; DO 16 x Rel. AC 120/230 V. It has the following key specifications: 1) It has 16 outputs that are electrically isolated in groups of 8. 2) It can switch loads with voltages between 24VDC to 120VDC and 24VAC to 230VAC. 3) It is suitable for switching AC/DC solenoid valves, contactors, motor starters, and signal lamps.

Uploaded by

electron13
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
249 views

Mif Ii

The document describes a relay output module called SM 322; DO 16 x Rel. AC 120/230 V. It has the following key specifications: 1) It has 16 outputs that are electrically isolated in groups of 8. 2) It can switch loads with voltages between 24VDC to 120VDC and 24VAC to 230VAC. 3) It is suitable for switching AC/DC solenoid valves, contactors, motor starters, and signal lamps.

Uploaded by

electron13
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Digital modules

3.32 Relay output module SM 322; DO 16 x Rel. AC 120/230 V; (6ES7322-1HH01-0AA0)

3.32 Relay output module SM 322; DO 16 x Rel. AC 120/230 V;


(6ES7322-1HH01-0AA0)

Order number
6ES7322-1HH01-0AA0

Properties
Properties of SM 322; DO 16 x Rel. AC 120/230 V:
● 16 outputs, electrically isolated in groups of 8
● Load voltage 24 VDC to 120 VDC; 24 VAC to 230 VAC
● Suitable for AC/DC solenoid valves, contactors, motor starters, FHP motors and signal
lamps.

Reaction to a shutdown of the power supply

Note
The internal 200-ms buffer capacitance discharges sufficient power after power off to allow
the user program to set a defined relay state.

Wiring and block diagrams of SM 322; DO 16 x Rel. AC 120/230 V




 







0 

 
  1

 /



  9
 
 






 0
 1

 0




① Channel number
② Status display - green
③ Backplane bus interface

S7-300 Automation System Module Data


Manual, 03/2011, A5E00105505-07 189
Digital modules
3.32 Relay output module SM 322; DO 16 x Rel. AC 120/230 V; (6ES7322-1HH01-0AA0)

Technical specifications of SM 322; DO 16 x Rel. AC 120/230 V

Technical specifications
Dimensions and weight
Dimensions W x H x D (mm) 40 x 125 x 117
Weight ca. 250 g
Module-specific data
Supports isochronous mode no
Number of outputs 16
Cable length
 unshielded max. 600 m
 shielded max. 1000 m

Voltages, currents, electrical potentials


Rated power supply L+ to the relays 24 VDC
Total current of outputs (per group) max. 8 A
Electrical isolation
 between channels and the backplane bus yes

 between channels yes


8
in groups of
Maximum potential difference
 Between Minternal and the power supply to relays 75 VDC/60 VAC

 Between Minternal and the power supply to relays and outputs 230 VAC

 Between outputs of different groups 500 VAC

Isolation test voltage


 between Minternal and the power supply to relays 500 VDC

 between Minternal and the power supply to relays and outputs 1500 VAC

 between outputs of different groups 2000 VAC

Current consumption
 from the backplane bus max. 100 mA
 from power supply L+ max. 250 mA

Power loss of the module typ. 4.5 W


Status, interrupts, diagnostics
Status display green LED per channel
Interrupts none
Diagnostic functions none

S7-300 Automation System Module Data


190 Manual, 03/2011, A5E00105505-07
Digital modules
3.32 Relay output module SM 322; DO 16 x Rel. AC 120/230 V; (6ES7322-1HH01-0AA0)

Technical specifications
Actuator selection data
Thermal current, continuous max. 2 A
Minimum load voltage / current 10 V / 10 mA
Short-circuit current to IEC 947-5-1 200 A, with B10/B16 circuit breaker
Switching capacity and service life of contacts
 with resistive load
Voltage Current Number of switching cycles (typ.)
24 VDC 2.0 A 0.1 million
1.0 A 0.2 million
0.5 A 1.0 million
60 VDC 0.5 A 0.2 million
120 VDC 0.2 A 0.6 million
24 VAC 1.5 A 1.5 million
48 VAC 1.5 A 1.5 million
60 VAC 1.5 A 1.5 million
120 VAC 2.0 A 1.0 million
1.0 A 1.5 million
0.5 A 2.0 million
230 VAC 2.0 A 1.0 million
1.0 A 1.5 million
0.5 A 2.0 million
 with inductive load to IEC 947-5-1 DC13/AC15
Voltage Current Number of switching cycles (typ.)
24 VDC 2.0 A 0.05 million
1.0 A 0.1 million
0.5 A 0.5 million
DC 60 V 0.5 A 0.1 million
DC 120 V 0.2 A 0.3 million
24 VAC 1.5 A 1 million
AC 48 V 1.5 A 1 million
AC 60 V 1.5 A 1 million
AC 120 V 2.0 A 0.7 million
1.0 A 1.0 million
0.5 A 1.5 million
230 VAC 2.0 A 0.7 million
1.0 A 1.0 million
0.5 A 1.5 million
An external protective circuit will increase the service life of contacts.
Size of the motor starter max. size 5 to NEMA
Lamp load 50 W / 230 VAC
5 W / 24 VDC
Contact protection (internal) none

S7-300 Automation System Module Data


Manual, 03/2011, A5E00105505-07 191
Digital modules
3.32 Relay output module SM 322; DO 16 x Rel. AC 120/230 V; (6ES7322-1HH01-0AA0)

Technical specifications
Wiring two outputs in parallel
 for redundant load control supported (only outputs of the same group)

 for performance increase not supported

Control of a digital input supported


Switching frequency
 Mechanical max. 10 Hz

 with resistive load max. 1 Hz

 with inductive load to IEC 947-5-1, DC13/AC15 max. 0.5 Hz

 with lamp load max. 1 Hz

Wiring of the actuators using a 20-pin front connector

S7-300 Automation System Module Data


192 Manual, 03/2011, A5E00105505-07