Flap Flow Meter
Flap Flow Meter
•
Flap Flow Meter monitoring
for Liquids •
analysing
Range:
0.5 - 3.5 … 200 - 1500 m3/h
Accuracy: ± 2.0 of reading
pmax: PN40, tmax: -40 … +300 °C
Connection: wafer flange
DN 25 … 500
Material: stainless steel,
Hastelloy C, PP, PTFE
Option: limit contacts,
analogue output with HART® or
PROFIBUS-PA®, Counter
D-65719 Hofheim/Ts.
CHINA, COLUMBIA, CZECHIA, DOMINICAN REPUBLIC, EGYPT, FRANCE, GERMANY, +49 (0) 61 92 2 99 - 0
GREAT BRITAIN, INDIA, INDONESIA, IRAN, ITALY, MALAYSIA, MEXICO, MOROCCO, Fax +49 (0) 61 92 2 33 98
NETHERLANDS, PERU, PHILIPPINES, POLAND, ROMANIA, SINGAPORE, SLOVAKIA, E-Mail: [email protected]
SPAIN, SWITZERLAND, THAILAND, TUNISIA, USA, VENEZUELA, VIETNAM Internet: www.kobold.com 1
Flap Flow Meter for Liquids Model: TSK
Applications Certification
Control of cooling- and flushing processes Explosion protection: BVS 03 ATEX H/B 112
Chemical industry CE-Marking: Pressure Equipment Directive
97/23/EC
Water- and waste-water technology
Power-plants
Display
Maschinery-building
Materials: Aluminium (stove-enameled)
Stainless steel (as option)
Outputs: inductive switch
inductive switch in safety design
microswitch
others on request
Ambient temperature: -40 °C up to +80 °C
(without switch)
-40 °C up to +65 °C
(with switch)
01 / 08-2008
Technical details
Transmitter:
ES with HART®-protocol
ES with HART®-protocol and 2 NAMUR-switches
ES with HART®-protocol and 1 NAMUR-switch /
1 pulse output
ES with PROFIBUS-PA®
ES with HART®-protocol and counter module
Certification
Explosion protection: DMT 00 ATEX E 075
Type of protection: II 2G EEx ia IIC T6
CE-Marking: Explosion Protection Directive
94/9/EC
01 / 08-2008
0 = without
1 = 1x inductive limit contact
0 = without S = Standard 2 = 2x inductive limit contacts
1 = with 0 = without (Aluminium) 6 = electr. transmitter ES,
1 = Certificate of compliance 0 = without
(FPM, max. 150 °C) E = Stainless steel 1 = %-Scale (Water) HART ® Protocol, 4-20 mA, EEx ia
with the order 2.1 X = with
Protection of incoming display IP 66 2 = Range-scale (Water) 7 = electr. transmitter ES,
2 = Test report 2.2 (see separate
solids (f. ex. metal T = Standard 4 = %-Scale (Media) HART® Protocol, 4-20 mA,
B = Inspection certificate 3.1 specifications)
chippings) in the (Aluminium) 5 = Range-scale (Media) EEx ia, 2x Namur contacts
C = Inspection certificate 3.2
transmission chamber with pressure 9 = electr. transmitter ES,
compensation PROFIBUS-PA ® , EEx ia
I = 4-20 mA with HART ®
and counter module
01 / 08-2008
Dimensions
Size Nominal pressure (standard) L [mm] D [mm]
DIN/EN ASME PN class Display Display DIN-/EN- ASME-flange h
aluminium stainless steel flange [mm]
50 2" 40 300 272 261 102 92,1 17
65 2 1/2" 40 300 272 261 122 102 21 (ASME = 17)
80 3" 40 300 272 261 138 127 31
100 4" 16 150 272 261 158 158 36
125 5" 16 150 352 341 186 186 45
150 6" 16 150 352 341 212 212 53
200 8" 16 150 352 341 268 268 80
250 10" 16 150 352 341 320 320 90
300 12" 10 150 372 361 370 381 100
350 14" 10 150 442 431 430 413 100
400 16" 10 150 452 441 482 470 130
500 20" 10 150 492 481 585 585 130
01 / 08-2008