Catalogue: HD2012 Software Operation Introduce-Password: 168
Catalogue: HD2012 Software Operation Introduce-Password: 168
Password: 168
Catalogue
Catalogue1 The types controller ……………………………..………………………………………………………….3
Chapter1 Summary…………………………………………………………………………………………………………….4.
1.1 Function............................................................................................................................... 4
2.1 Install.................................................................................................................................... 4
2.2 Unload……………………………………………………………………………………………………………………………….5
1 / 24
HD2012 software Operation Introduce-
Password: 168
Chapter 1 Summary
3 / 24
HD2012 software Operation Introduce-
Password: 168
4 / 24
HD2012 software Operation Introduce-
Password: 168
Chapter Luminance
3 The details Time
of on/off
Tool using
setting
regularly
Scre
3.1enSoftware interface
parame
ter
Communication port, double -click could open
Open <<HD2012>>software, you could
communication port see interface.As below:
title
Menu
Shortcut
menu
Virtual screen
and preview
预览窗
Virtual tools ( zoom in or out/moving left or
right/turn page left or right )
5 / 24
HD2012 software Operation Introduce-
Password: 168
6 / 24
HD2012 software Operation Introduce-
Password: 168
It include
Program、Text、Hypertext、Time、Clock、Count、Temperature、Delet
e、Send、Export、Adjust time、Preview
contents etc)
Hypertext : used for set new Hypertext district ( it could insert
picture 、table etc)
Time : used for set time district ,showing system time(Calendar
type)
Clock :used for set clock district, showing for system type (simulated
type)
Count : used for count on/count down district
8 / 24
HD2012 software Operation Introduce-
Password: 168
Virtual screen
Scre
en
parame
ter
Communication port, double -click cold open
communication port
Luminance setting:it have 3 types (suggest not change);
Time switch:Using for time on /time off
9 / 24
HD2012 software Operation Introduce-
Password: 168
Basic :Before setting ,you need to know your led module type、
Parameter、etc; wrong setting will now showing normal.
a. Data polarity set wrong: it showing red back and black font.
b. 138 decoder set wrong :it will result led module not showing or wrong
showing .
c. Color set wrong:it will result Windth or Hight turn back.
d. OE polarity set wrong: it will result that led module showing
luminance not equality,some lines is high luminance,some
Lines is low luminance
e. Scan mode set wrong: it will result mess code.
10 / 24
HD2012 software Operation Introduce-
Password: 168
After setting ok, click Finish, then finish the screen settin
(Our example is for general P10 setting)
As below ,you could set Luminance and time switch.
11 / 24
HD2012 software Operation Introduce-
Password: 168
Set new
program ,it
could set
20pcs Play program by week, you
could select
file; if we need set lots program ,just need repeat the second 、third
process. (it could play all programs in a screen );if need a software
control several screens file, just need repeat the first 、 second 、 third
process.
The program finished ,it could save (It saved in the install path of Proj
folder).also you could save as in defined path .Through Preview tool, we
could see the setting effects, you could adjust whatever you need
Text
district Over more than 40
13showing
/ 24 In this place ,you
serials
could edit word,
When set type; more than 30
need select font
1ms,it is serials of exit
you could change.
fastest showing type
HD2012 software Operation Introduce-
Password: 168
Noted; Pure wording showing ,we suggest using Text district edit(simple
setting );<<HD2012>> have strong edit function, it could change of
single word by middle in left or right 、 middle in up or down 、 font
Click
Editor
When finished
making, just
Click Table-New, Close it is ok.
It could set, not
support Excel
export directly
14 / 24
HD2012 software Operation Introduce-
Password: 168
Hyperte
xt
district
The modes
Add or of picture
delete showing
picture and exiting
type
The led module time showing is same like text、hypertext,just click the
Time district,as below:
Ways:According to 4.1 and 4.2 contents, set a screen and
program.
Click Time, it will come out Time district ( you could set
Width、Height、of coordinate freedom),the setting is simple, just
adjust the location.
15 / 24
时间区
域坐标
设置
HD2012 software Operation Introduce-
Password: 168
Calendar
preview
The Clock showing is same like text、Hypertext, just click the Clock is
ok, the process as below:
Ways: According to 4.1 and 4.2 contents, set a screen and program.
Then click Clock, it will come out Clock district ( you could set
Width、Height、of coordinate freedom),the setting is simple, just
adjust the location.
Clock preview
Set
coordin Set
Add
ate width
backgro
place and
und
color
16 / 24
HD2012 software Operation Introduce-
Password: 168
This place
Count down/Up could enter
Set background
coordin contents
ate
place
17 / 24
温度内容预
览
HD2012 software Operation Introduce-
Password: 168
Edit
back
Set
Set grou
paramet
coordin nd
er of
ate Tempera
place ture
From 5.1-5.6we could acknowledge lots of our led controller functions
and districts. It could meet different circumstance apply.
as below:
Controller connected
computer directly, using
cross line
(One side is from left to right, another is from left to right)Parallel line
making - two sides plugs of Ethernet cable making is the same. Both is
TIE/EIA-568B or both is TIE/568A standard.
19 / 24
HD2012 software Operation Introduce-
Password: 168
Controller connected
Router directly, using
parallel line
I n LAN
network of 1
PCS ,select
this type
20 / 24
HD2012 software Operation Introduce-
Password: 168
After selected,
I n LAN just close is ok
network of
lots PCS
HD-E,
select this
type
IP management tools
21 / 24
HD2012 software Operation Introduce-
Password: 168
It need
Change IP After
select,
address, the finished
then
Gateway need , just
could
consistent with click set
reset IP
6.4.3 Vedio of lots HD-E controller communication
LAN network
Check Updated
firmware new
version of firmware
controller
Click Update firmware, select the bin file, then finish update. (Updated
firmware just through RS232 or Ethernet port, USB port do not)
Noted: in updated process, it do not permit power off electronic and do
not pull up the serial port
Catalogue 2.2 Controller how to return factory setting
22 / 24
HD2012 software Operation Introduce-
Password: 168
Seve
rn
diffe
rent
testi
ng
type
Catalogue2.4 The screen play
s program by time on/off
regularly
Play program by time on/off regularly, please reference setting of 4.1
23 / 24
HD2012 software Operation Introduce-
Password: 168
24 / 24