General Assumptions and Data Requirements
General Assumptions and Data Requirements
1 PSV 6
Splitting Column
(C-221)
Ground Floor PSV
2 PSV 7
3 PSV 1
HP boiler safety
valve
HP boiler safety
valve
4 PSV 2
DM water pump
6 PSV 4
(P-222)
Standby Oil and
7 Water pump PSV 5
(P-223)
8 MP steam PSV 9
9 K1 Heat exchanger PSV 8
Main Still
10 RD1
(C-251)
Back end Still
11 RD2
(C-281)
Assumptions to be made
There is discrepancy in set pressure of PSV 1 and PSV 2. Per 'DFA PSV and RD list' sheet of provided spreadsheet; set press
kg/cm² and 70 kg/cm² respectively, while per 'HP Boiler Safety Valves' sheet of document; set pressure of both the PSVs is
SOP' spreadsheet; set pressure of PSV 1 and PSV 2 is 67 kg/cm² and 68 kg/cm² respectively. Hence require confirmation ab
PSVs.
a)There are three HP boilers with each boiler having capacity of 3.5 TPH. Therefore, maximum design capacity will be cons
listed boiler for blocked outlet scenario. Please confirm.
Flowrate in each equipment : 3.5 tons/hr
There is discrepancy in set pressure of PSV 1 and PSV 2. Per 'DFA PSV and RD list' sheet of provided spreadsheet; set press
kg/cm² and 70 kg/cm² respectively, while per 'HP Boiler Safety Valves' sheet of document; set pressure of both the PSVs is
SOP' spreadsheet; set pressure of PSV 1 and PSV 2 is 67 kg/cm² and 68 kg/cm² respectively. Hence require confirmation ab
PSVs.
a)There are three HP boilers with each boiler having capacity of 3.5 TPH. Therefore, maximum design capacity will be cons
listed boiler for blocked outlet scenario. Please confirm.
There is discrepancy in set pressure of PSV 4. Per 'DFA PSV and RD list' sheet of provided spreadsheet; set pressure of PSV
'DFA PSV 4' sheet of document; set pressure of the PSV is 66.6 kg/cm² also per 'DFA SOP' spreadsheet; set pressure of PSV
confirmation about set pressure of PSV.
Data provided by site's mail on 24/01/2018:
PSV size : 1D2
Set pressure : 63.8 kg/cm2
Flowrate : 4 tons/hr
Operating pressure: 60 bar
There is discrepancy in PSV tag. PSV tag given in scope list is PSV 9 and same is mentioned in Isometrics drawing, while da
Set pressure of PSV 9 is 8 kg/cm2 and Set pressure of PSV 10 is 10 kg/cm2, Kindly confirm PSV and its set pressure which is
header.
There is discrepancy in rupture pressure of RD1. Per 'DFA PSV and RD list' sheet of provided spreadsheet; rupture pressure
per 'RD1' sheet of document; rupture pressure of the RD is 0.54 kg/cm². Hence require confirmation about rupture pressu
Data provided by site's mail on 24/01/2018:
There is discrepancy in rupture pressure of RD2. Per 'DFA PSV and RD list' sheet of provided spreadsheet; rupture pressure
per 'RD2' sheet of document; rupture pressure of the RD is 0.492 kg/cm². Hence require confirmation about rupture pres
Data still outstanding/pending