Heat Recovery Division, Inc.: Enquiry Data Sheet Forair Preheater Replacement or Retrofit General Data

This document contains an enquiry data sheet for an air preheater replacement or retrofit project. It requests general plant information as well as details on furnace design, fuel characteristics, combustion parameters, stack configuration, pressure and temperature measurements, and specifications of existing equipment including the furnace, fans, and air preheaters. The level of detail requested will allow for the evaluation and selection of appropriate replacement equipment.

Uploaded by

Assure Turbines
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
205 views1 page

Heat Recovery Division, Inc.: Enquiry Data Sheet Forair Preheater Replacement or Retrofit General Data

This document contains an enquiry data sheet for an air preheater replacement or retrofit project. It requests general plant information as well as details on furnace design, fuel characteristics, combustion parameters, stack configuration, pressure and temperature measurements, and specifications of existing equipment including the furnace, fans, and air preheaters. The level of detail requested will allow for the evaluation and selection of appropriate replacement equipment.

Uploaded by

Assure Turbines
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

BD

Heat Recovery Division, Inc.


9180 Oakhurst Road Suite 4
Seminole, Florida 33776
Phone: +1 727-392-0492
E-Mail: [email protected]
Enquiry Data Sheet forAir Preheater Replacement or Retrofit
General data
Plant name: Furnace type (CDU, VDU, etc…)
Plant location: Furnace number:
Ambient conditons
Averge Air temp. °C Min. Winter temp. °C
Draft type (please "x")
natural draft balanced draft forced draft
Design duty of furnace
MW Gcal/hr
Typical fuel
Heavy Oil consumption kg/hr light Oil consumption kg/hr
LHV kJ/kg LHV kJ/kg
Gas consumption Nm3/hr
Methane Vol. % Average Hydrosulfide ppm
Ethane Vol. % max. Hydrosulfide ppm
Propane Vol. % Peak Hydrosulfide ppm
Butane Vol. % Sulfur Vol. %
Pentane Vol. % Argon Vol. %
Hexane Vol. % Water Vol. %
Carbondioxide Vol. % Carbonmonoxide Vol. %
Nitrogen Vol. % Acetylen Vol. %
Hydrogen Vol. % Ethene / Ethylen Vol. %
Ammonia Vol. % Propen / Propylen Vol. %
Combustion
Excess air in furnace -
O2 content before entrance to existing APH, or leaving convection section Vol. %, dry
O2 content after APH or at stack Vol. %, dry
Number of burners - Type of burners
Stack
Height of Stack m Fluegas temp. at stack °C
NOx emission at stack mg/Nm3, dry max. NOx emission limit mg/Nm3, dry
Number of furnaces connected to the stack
Pressure
Flue gas pressure before APH or leaving convection section mbar or inWC
Flue gas pressure before ID-Fan mbar or InWC
Air Pressure after FD-Fan mbar or InWC
Air Pressure after existing Air Preheater mbar or InWC
Air Pressure before burners mbar or InWC
Temperatures
normal °C
Flue gas temp. before APH (or leaving convection section) min. °C
max. °C
Flue gas temperature before ID-Fan normal °C
Air temperature after Air preheater normal °C
Air temperature to burner normal °C
Existing equipment
Furnace please send furnace data sheet + GA-Drawing
FD-Fan please send Fan curve
ID-Fan please send Fan curve
Existing Air Preheater please send data sheet
Existing Air Pre-Preheater (for example coil) please send data sheet + GA-Drawing