Thyristor Controlled Series Capacitor With Automatic Control
Thyristor Controlled Series Capacitor With Automatic Control
ABSTRACT
An increasingly competitive market where economic and environmental pressures limit their
scope to expand transmission facilities.The optimization of transmission corridors for power
transfer has become a great importance. In this scenario, the FACTS technology is an attractive
option for increasing system operation flexibility [1] , New developments in high-current, high-
power electronics are making it possible to control electronically the power flows on the high
voltage side of the network during both steady state and transient operation.
In this paper a series controller from the Flexible AC Transmission System (FACTS) family
called as ‘Thyristor Controlled Series Capacitor’ (TCSC) is designed using PIC microcontroller.
Thyristor controlled series compensator (TCSC), is the first generation of FACTS controller, can
govern line impedance through introduction of a thyristor controlled capacitor in series with the
transmission line. A grid of transmission lines operating at high voltages is required to transmit
power from generating stations to load. In addition to transmission lines that carry power from
source to load, modern power systems are highly interconnected for economic reasons. The large
interconnected transmission networks occur to faults due to the lightning discharges and reduce
insulation strength. Changing loads and atmospheric conditions are unpredictable factors. This
may cause overloading of lines due to which voltage collapse takes place. All the above said
things are undesirable for secure and economic operation of a line. These problems can be erased
by providing sufficient margin of working parameters and power transfer, but it is not possible
due to expansion of transmission network. Still the required margin is reduced by introduction of
fast dynamic control over reactive and active power by high power electronic controllers.
The TCSC operation which we are simulating in MATLAB (i) To calculate the various
resonance points in the impedance characteristics of the TCSC w.r.t. various firing angle.
INTRODUCTION
The TCSC is used as series compensator in transmission system, it can be designed to control the
power flow in order to increase the power transfer limits or to improve the transient stability.
Power quality is an issue that is nowadays gaining significant interest to both electric utilities and
endusers. The term power quality comprises a multitude of aspects, which is not new in essence,
but has a growing concern due to the dissemination of sensitive loads (e.g. industrial plants) that
use power electronics as a means of modernizing their manufacturing processes. The TCSC
controller can provide a very fast action to increase the synchronization power through quick
1|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
changing of the equivalent capacitive reactance to the full compensation in first few cycles after
a fault, hence subsequent oscillations are damped. Series capacitor compensation is an approach
to improve stability limits and increase transfer capabilities. The transmitted power through a
line is inversely proportional to the transfer impedance.
Power system stability may be broadly defined as the ability of a power system to remain in a
state of operating equilibrium under normal operating conditions and to regain an acceptable
state of equilibrium after being subjected to a disturbance.[3] Stability of power system has been
a major concern in system operation. The stability of a system determines whether the system
can settle down to the original or close to the steady state after the transients disappear. In
general, power system stability is the ability to respond to a disturbance from its normal
operation by returning to a condition where the operation is again normal. [3] A power system is
said to be steady state stable for a particular operating condition if, following any small
disturbance, it reaches a steady state operating condition which is identical or close to the
predisturbance operating condition.[3] Transient stability is defined as the ability of the power
system to maintain synchronism when subjected to a severe transient disturbance. A system is
transiently stable if it can survive the initial disturbance but it is transiently unstable if it cannot
survive. For the transiently stable system, a large disturbance suddenly occurs, the system angle
spread starts to increase but reaches a peak and then starts to decline, making the system
transiently stable. The resulting system response involves large excursions of generator rotor
angles. Transient stability is sometimes called first swing stability as the instability often occurs
during the first angle swing.[3]
To meet rising demand of power, FACTS devices are introduced in the transmission line to
enhance its power transfer capability; either in series or in shunt. It is obvious by series
compensation technique that power transfer between two stations can be affected by adjusting
the net series impedance of line. One such conventional and established method of increasing
transmission line capability is to install a series capacitor, which reduces the net series
impedance, thus allowing additional power to be transferred. Although this method is well
known, slow switching times is the limitation of its use. Thyristor controllers, on the other hand,
are able to rapidly and continuously control the line compensation over a continuous range with
resulting flexibility. Controller used for series compensation is the Thyristor Controlled Series
Compensator (TCSC). TCSC controllers use thyristor-controlled reactor (TCR) in parallel with
capacitor segments of series capacitor bank (Figure 1). The combination of TCR and capacitor
allow the capacitive reactance to be smoothly controlled over a wide range and switched upon
command to a condition where the bidirectional thyristor pairs conduct continuously and insert
an inductive reactance into the line. The series compensation is an economic method of
improving power transmission capability of the lines.
2|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
CONCEPT OF TCSC
Figure 1 is a schematic representation of a TCSC module [2], which consists of a series capacitor
bank in parallel with a Thyristor Controlled Reactor (TCR). The controlling element is the
thyristor controller, shown as a bidirectional thyristor valve.
A TCSC is a series controlled capacitive reactance that can provide continuous control of
power on the ac line over a wide range. The functioning of TCSC can be comprehended by
analyzing the behavior of a variable inductor connected in series with a fixed capacitor.
The introduction of thyristor technology brings the concept of series compensation still a large
step further. Important added benefits are:
1. Increased dynamic stability of power transmission systems,
2. Improved stability,
3. Improved load sharing between parallel lines,
4. Elimination of line overloads,
5. Reduction of loop flows,
6. Improved voltage regulation and reactive power balance,
7. Elimination of subsynchronous resonance risks (SSR),
8. Damping of active power oscillations,
9. Dynamic power flow control,
10. Minimizing system losses,
11. Reduction of the gap between commercial and physical flows.
12. Optimizing load sharing between parallel circuits,
CLASSIFICATION OF STABILITY
The stability limit represents the maximum stead state power flow possible when the
synchronous machine is operating with stability. There are two forms of stability. One is
synchronous stability and other is voltage stability. Synchronous stability can be assessed by
using P-δ curve and voltage stability can be estimated using P-V curve as explained below.
3|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
As shown in the figure 2, the impedance of TCSC acts like a function of firing angle. According
to this diagram we have three regions:
1. Capacitive region
2. Inductive region
3. Resonance region
If we want to decrease the power transfer from sending bus bar to receiving bus bar we have to
operate TCSC in inductive region. In such scenario the length of transmission line enlarged. In
such mode the TCSC is rarely operated. If we want to decrease the electric length of
transmission line that is we want to amplify power transfer from sending bus bar to receiving bus
4|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
bar, TCSC should be operated in capacitive region. Due to stability issues TCSC is not operated
in Resonance region.
There are three modes of operation of TCSC depending upon the firing angle of the pulses fed to
the thyristor.
1. Thyristor blocked mode
2. Thyristor bypassed mode
3. Vernier or Partially Conducting Thyristor operating mode
5|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
6|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
Series capacitive compensation is thus used to reduce the series reactive impedance to
minimize receiving end voltage variation and the possibility of voltage collapse. It is also
observed that the compensation by using this technique i.e TCSC is faster when compared to
other compensating techniques such as mechanical switching and synchronous condensers.
PV curves have been drawn for both the cases. The system stability has been assessed with
PV curves.
CONCLUSIONS
Thyristor Control Series Capacitors (TCSC) is maintain the system stability that means if any
error occurs during the transmission of electric power, this device is solve the error and work
continuously. The function of this device is the ability to change impedance transmission lines
and thus increase the transmission capacity and power flow control. TCSC with his composition
and capabilities allows widely using in power system. It can be used also for damping of active
7|Page
NOVATEUR PUBLICATIONS
INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT]
ISSN: 2394-3696
VOLUME 2, ISSUE 4, APR.-2015
power oscillations, improve dynamic and voltage stability, eliminating SSR and other. Before the
installation of TCSC is important to determine the parameters of TCSC, prepare power analysis
and analysis of the behavior of TCSC at various cases. Thus the subject of analysis was on a
simple model of electrical network with two parallel lines simulate the behaviour of TCSC in
terms of use in power flow control through the lines. The TCSC has also wide usage, it just
makes it suitable for deployment of the electricity system to ensure better operational parameters
and safe power transmission.
REFERENCES
8|Page