2.5.2 DC330 Component Code List: IOTC: WR Protect - For What
This document contains a list of component codes for a machine. It includes the component name, type (digital input, output, etc.), status indicators for when the component is on or off, and a brief description. There are over 50 components listed, ranging from sensors to motors to temperature readings. The component codes are organized into sections for the main machine components and the IOTC board components.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
88 views8 pages
2.5.2 DC330 Component Code List: IOTC: WR Protect - For What
This document contains a list of component codes for a machine. It includes the component name, type (digital input, output, etc.), status indicators for when the component is on or off, and a brief description. There are over 50 components listed, ranging from sensors to motors to temperature readings. The component codes are organized into sections for the main machine components and the IOTC board components.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8
2.5.
2 DC330 Component Code List Component Name
Chain-Link Type H/L Status <IIT> (Part Name or Signal Name) Side FP Triac (100/200V H: OFF/L: ON Type) DI: Digital Input, DO: Digital Output 010-001 DO machines) (Turned OFF in 5 seconds) Component Name H: OFF/L: ON Chain-Link Type H/L Status 010-002 Side LP Triac (200V machine) DO (Part Name or Signal Name) (Turned OFF in 5 seconds) 005-001 Output All *1 DO H: ON/L: OFF Center FP Triac (100/200V H: OFF/L: ON 005-010 IIT Drive Motor (100% driven) DO H: ON/L: OFF 010-003 DO machines) (Turned OFF in 5 seconds) 005-011 IIT Drive Motor (400% driven) DO H: ON/L: OFF Center LP (200V machine)/ H: OFF/L: ON H: Paper detected/L: No paper 010-004 DO 005-105 IIT A4/B5 Sensor DI Sub Heater Triac (100V machine) (Turned OFF in 5 seconds) detected. 010-005 Exhaust Fan LH: Speed DO H: Low Speed/L: High Speed H: Paper detected/L: No paper 010-006 Exhaust Fan LH: On DO H: OFF/L: ON 005-106 IIT A3/B4 Sensor DI detected. 010-007 Exhaust Fan RH: Speed DO H: Low Speed/L: High Speed H: Paper detected/L: No paper 010-008 Exhaust Fan RH: On DO H: OFF/L: ON 005-107 IIT A2/B3 Sensor DI detected. 010-011 Fuser Drive Motor: Bit 0 H: Paper detected/L: No paper 010-012 Fuser Drive Motor: Bit 1 DO *1 005-108 IIT A1/B2 Sensor DI detected. 010-013 Fuser Drive Motor: bit 2 H: Paper detected/L: No paper 010-200 Over Heat Thermostat DI H: Normal/L: Overheat 005-109 IIT A0 Sensor DI detected. 010-201 Thermistor 1: Open DI *4 H: Paper detected/L: No paper 010-202 Thermistor 2: Over Heat DI *5 005-124 IIT Feed Stop Sensor DI detected. 010-203 Thermistor 2: Open DI *4 H: Paper detected/L: No paper 005-125 IIT Regi Sensor DI 010-204 Thermistor 3: Open DI *4 detected. 010-205 Thermistor 4: Over Heat DI *5 H: Paper detected/L: No paper 005-135 IIT Right Skew Sensor DI 010-206 Thermistor 4: Open DI *4 detected. 010-207 Exit Motion Sensor DI (pulse) H: Paper detected/L: No paper 005-145 IIT Left Skew Sensor DI H: Paper detected./L: No paper detected. 010-208 Exit Jam Switch DI detected. 005-301 IIT Cover Sensor RH DI H: Open/L: Close 010-209 Exhaust Fan LH: Fail DI H: Abnormal/L: Normal 005-302 IIT Cover Sensor LH DI H: Open/L: Close 010-210 Exhaust Fan RH: Fail DI H: Abnormal/L: Normal H: Paper detected/Open/ON H: Asynchronous/L: 005-499 Input All *2 DI L: No paper 010-211 Fuser Drive Motor: Lock DI Synchronous detected/Close/OFF 010-250 Thermistor 1: Temp AI *6 023-401 <Start> key DI H: ON/L: OFF 010-251 Thermistor 2: Temp AI *6 023-402 <Stop> key DI H: ON/L: OFF 010-252 Thermistor 3: Temp AI *6 062-001 CIS R/L DO H: ON/L: OFF IOTC: WR Protect - For what *1) Turn the IIT Drive Motor (100% driven) and CIS R/L ON/OFF at the same time. 042-002 DO H: Disable/L: Enable purpose? *2) Check the ON/OFF of all sensors. 042-005 Attention Light: Lamp On DO H: OFF/L: ON 042-006 Attention Light: Lamp Color DO H: Amber/L: Green <IOT> 042-007 Attention Light: Buzzer DO H: OFF/L: ON Type) DI: Digital Input, DO: Digital Output, AI: Analog Input, AO: Analog Output, 042-202 IOTC: Vref Monitor DI H: Normal/L: Error I I: Interrupt Input, TI: Timer Input 042-261 IOTC: Int Cut Trigger II H: -/L: Interrupt AI has steps between 0 and 1023 and AO has steps between 0 and 255. 042-262 IOTC: Int Page Sync II H: -/L: Interrupt
2-91 2.5 System Data/Component Code List
Chapter 2 Troubleshooting 2-92 Chapter 2 Troubleshooting 2.5 System Data/Component Code List Component Name Component Name Chain-Link Type H/L Status Chain-Link Type H/L Status (Part Name or Signal Name) (Part Name or Signal Name) 046-001 HVPS: BCR On DO H: OFF/L: ON H: No paper detected/L: Paper 071-104 Roll1 30" Sensor DI 046-002 HVPS: DB On DO H: OFF/L: ON detected 046-003 HVPS: BTR On DO H: OFF/L: ON H: No paper detected/L: Paper 071-105 Roll1 Cut Trigger Sensor DI 046-004 HVPS: BTR ± DO H: -/L: + detected 046-005 HVPS: DTS On DO H: OFF/L: ON H: No paper detected/L: Paper 071-106 RFC Vertical Jam Sensor DI 046-050 HVPS: BCR ACI Control AO *10 detected 046-051 HVPS: BCR DCV Control AO *10 071-200 Roll1 Cutter Switch LH DI H: Not Detected/L: Detected 046-052 HVPS: DB ACV Control AO *10 071-201 Roll1 Cutter Switch RH DI H: Not Detected/L: Detected 046-053 HVPS: DB DCV Control AO *10 071-202 Roll1 Auto Cut Switch DI H: Released/L: Pressed 046-054 HVPS: BTR DCIV Control AO *10 071-270 Roll1 Feeder Motor: Clock TI (pulse) 046-055 HVPS: DTS ACV Control AO *10 071-271 Roll1 No Paper Sensor TI (pulse) 046-200 24B Monitor DI H: Normal/L: Error 071-300 Roll1 Cutter Interlock Switch DI H: Close/L: Open 046-201 5B Monitor DI H: Normal/L: Error 071-301 RFC1 Drawer Open Switch DI H: Open/L: Close 046-202 24C Monitor DI H: Normal/L: Error 072-001 Roll2 Feeder Motor: Bit 0 046-250 HVPS: BTR DCV Monitor AI *11 072-002 Roll2 Feeder Motor: Bit 1 DO *2 061-001 IOTC: LPH On DO H: ON/L: OFF 072-003 Roll2 Feeder Motor: Bit 2 061-002 IOTC: LPHC Reset DO H: -/L: Reset 072-004 Roll2 Cutter Motor: Bit 0 DO *3 (Turned OFF in 0.8 second) - I heard this is impossible. Is 072-005 Roll2 Cutter Motor: Bit 1 061-080 IOTC: LPH Test 2dot Half Soft H: No paper detected/L: Paper this really possible? 072-100 Roll2 Set Sensor DI - I heard this is impossible. Is detected 061-081 IOTC: LPH Test All Black Soft H: No paper detected/L: Paper this really possible? 072-101 Roll2 A3 Sensor DI 061-200 LPHIF: 5C Monitor DI H: Abnormal/L: Normal detected 061-201 IOTC: LPHC Acc Ready DI H: Ready/L: Busy H: No paper detected/L: Paper 072-102 Roll2 A2 Sensor DI 061-250 LPHIF: LPH Temp Thermistor AI *7 detected 061-270 IOTC: Line Sync TI (pulse) H: No paper detected/L: Paper 072-103 Roll2 A1 Sensor DI detected 071-001 Roll1 Feeder Motor: Bit 0 071-002 Roll1 Feeder Motor: Bit 1 DO *2 H: No paper detected/L: Paper 072-104 Roll2 30" Sensor DI 071-003 Roll1 Feeder Motor: Bit 2 detected 071-004 Roll1 Cutter Motor: Bit 0 H: No paper detected/L: Paper DO *3 (Turned OFF in 0.8 second) 072-105 Roll2 Cut Trigger Sensor DI 071-005 Roll1 Cutter Motor: Bit 1 detected 071-006 RFC Take Away Clutch DO H: OFF/L: ON 072-200 Roll2 Cutter LH Switch DI H: Not Detected/L: Detected H: No paper detected/L: Paper 072-201 Roll2 Cutter RH Switch DI H: Not Detected/L: Detected 071-100 Roll1 Set Sensor DI 072-202 Roll2 Auto Cut Switch DI H: Released/L: Pressed detected H: No paper detected/L: Paper 072-270 Roll2 Feeder Motor: Clock TI (pulse) 071-101 Roll1 A3 Sensor DI 072-271 Roll2 No Paper Sensor TI (pulse) detected H: No paper detected/L: Paper 072-300 Roll2 Cutter Interlock Switch DI H: Close/L: Open 071-102 Roll1 A2 Sensor DI 072-301 RFC2 Drawer Open Switch DI H: Open/L: Close detected H: No paper detected/L: Paper 075-001 Manual Feed Clutch DO H: OFF/L: ON 071-103 Roll1 A1 Sensor DI H: No paper detected/L: Paper detected 075-100 Manual No Paper Sensor DI detected Component Name *1) Fuser Drive Motor: Bit 0 to 2 Chain-Link Type H/L Status (Part Name or Signal Name) Output Voltage Motor Operation H: No paper detected/L: Paper Increment Clock Frequency H/Roll Peripheral Velocity 075-101 Manual A3 Sensor DI Bit 2 Bit 1 Bit 0 detected (Hz) (reference) (mm/sec) H: No paper detected/L: Paper H H H 0 0.000 0 075-102 Manual A2 Sensor DI detected H H L 1 1111.596 59.4 (TBD) H: No paper detected/L: Paper H L H 2 1113.452 59.6 (TBD) 075-103 Manual A1 Sensor DI detected H L L 3 1115.308 59.8 (TBD) H: No paper detected/L: Paper 075-104 Manual 30" Sensor DI L H H 4 1117.163 60.0 (TBD) detected L H L 5 1119.019 60.2 (TBD) H: No paper detected/L: Paper 075-105 Manual Feed Stop Sensor DI L L H 6 1120.875 60.4 (TBD) detected H: No paper detected/L: Paper L L L 7 1122.731 60.6 (TBD) 075-106 Manual Page Sync Sensor DI *2) Roll1/2 Feeder Motor: Bit 0 to 2 detected 077-001 Paper Heater Triac (Tr side) DO H: ON/L: OFF Output Voltage Increment Motor Operation H: No paper detected/L: Paper Bit 2 Bit 1 Bit 0 077-100 RFC Page Sync Sensor DI detected H H H 0 OFF (No slow down, Energizing OFF) H: No paper detected/L: Paper H H L 1 Reverse rotation 077-101 H-Tra Jam Sensor DI detected H L H 2 Ignore (Continue the control before this) 077-300 Swing Frame Interlock Switch DI H: Open/L: Close H L L 3 Ignore (Continue the control before this) 077-301 Fuser Cover Interlock Switch DI H: Open/L: Close L H H 4 Forward rotation at low speed 077-302 Front Door Interlock Switch DI H: Open/L: Close L H L 5 Forward rotation at high speed 077-303 H-Tra Open Sensor DI H: Close/L: Open L L H 6 Stop (Slow down, Energizing OFF) 091-001 Main Drive Motor: On DO H: OFF/L: ON L L L 7 Hold (Slow down, Energizing ON) H: Asynchronous/ 091-200 Main Drive Motor: Lock DI *3) Roll1/2 Cutter Motor: Bit 0 to 1 L: Synchronous Internal Voltage Output Voltage H: No toner detected/L: Toner Cutter Operation 091-201 Toner Empty Sensor DI Bit 1 Bit 0 *2 *1 detected 091-202 Waste Toner Bottle Full Sensor DI H: Full/L: Not Full H H 0V 0V Brake 091-250 Open Air Sensor: Hum AI *9 L H +24V 0V Scan from LH side to RH side 091-251 Open Air Sensor: Temp AI *8 H L 0V +24V Scan from RH side to LH side 091-300 Rear Top Cover Switch DI H: Open/L: Close L L OFF OFF Off 093-001 Deve Drive Clutch DO H: OFF/L: ON *1) RFC1: P443-21Pin, RFC2: P444-19Pin *2) RFC1: P443-19Pin, RFC2: P444-17Pin *4) Thermistor 1 - 4: Open Internal Thermistor Status Scan Temperature Resistance Voltage Voltage Lower or equal 680 KOhm or 3.17V or Open Circuit than -15°C L higher higher equivalent Higher than -15°C Lower than Lower than Normal H equivalent 680 KOhm 3.17V