Ecotek DesignManual v2015 02
Ecotek DesignManual v2015 02
UP TO
Section Page
1 DESIGN DETAIL
Contents 2
Overview - features and benefits 3
Applications 4
Material and colour selection 5
General specifications 6
Lapping details 7
Accessory information 8 - 11
Span tables & thermal ratings 12 - 13
Span tables for attached canopys 14 - 15
Roof penetrations 16 - 17
Technical properties 18 - 19
Acoustic properties 20
Fire properties 21 - 23
2 DETAILING AND FIXING
Dead Load and Fixing information 24 - 25
Fixing and rainwater lapping information 26
Typical roof plan 27
- Typical gable roof 27
- Typical skillion roof 28
Typical details 29
- Gutter, panel lap and roof end details 29
- Typical hip roof junction 30
- Typical skillion roof 31
- Optional plaster lining with wall junction detail 31
Corrugated infill detail 32
Rainwater goods 33 - 35
3 CERTIFICATION
Fire properties 36 - 38
Cyclone testing 39
Codemark certification 40
Product compliance certification 41
4 SUPPORT DOCUMENTATION
Warranty Period Information 42
Warranty Terms and Conditions 43
ARCPANEL ecotek roof panel Design and Detailing Manual - publishing and version details
This manual is subject to regular updates, please ensure that you are working with the latest version.
Contact ARCPANEL to receive the latest version on 1300 200 004 or email [email protected]
This manual and its contents are Copyright © and may not be reproduced without the permission of ARCPANEL.
On site time spent fitting trusses, eave linings, plasterboard, battens, insulation lining, roof sheeting and painting, is
eliminated when using ARCPANEL ecotek roof panel.
Pre-finished top and bottom sheet - extensive range of COLORBOND ® colours available
Dependant on the design, cantilevers of up to 40% the actual backspan can be achieved
ARCPANEL ecotek roof panel is available in COLORBOND® Ultra, Stainless Steel, Zincalume® & Xtreme
Rapid installation makes the ARCPANEL ecotek roof panel a clear winner over traditional roof construction
Superior standard thermal ratings up to R6.1 are achieved using the ARCPANEL ecotek roof panel
ARCPANEL Applications
Roof Types
Straight panels can be manufactured up to 24 metres in length, suitable
for housing, awnings, patios, commercial and industrial projects.
Straight & large curved panels can be manufactured using XRW,
Ultra, Stainless Steel, Zincalume® and Xtreme. A range of
COLORBOND® colours are available, with limited colour ranges
in Stainless Steel and Xtreme.
An ARCPANEL insulated roof system with COLORBOND® steel plays a major part in the design of a thermally efficient
building. COLORBOND® steel now includes Thermatech® solar reflectance technology to reflect more of the sun’s heat,
especially in summer. In hot weather, COLORBOND® steel with Thermatech® can help reduce peak roof temperatures by
up to 11oC.
For a superior thermally efficient building, if you select COLORBOND® Coolmax® steel in Whitehaven®, you could help
reduce the annual cooling energy costs of your building by up to 7.5%¹ compared to COLORBOND® steel
Warranty Information
Historically, to obtain a significant warranty in severe marine, coastal, aquatic
centres, industrial or harsh chemical environments stainless steel products are
generally specified. However, using ARCPANEL Ecotek Xtreme Roof Panel™ will
provide warranties up to 25 years.
COLORBOND
Basalt™ Dark 0.69 M
Classic Cream ™ Very Light 0.31* L
Cottage Green Dark 0.75 D
Cove™ Light 0.54 L
Deep Ocean® Dark 0.749 D
Dune® Light 0.466 L
Evening Haze® Light 0.427 L
Gully™ Dark 0.63 M
Ironstone® Dark 0.74 D
Jasper® Dark 0.682 M
Mangrove™ Dark 0.64 M
Manor Red® Dark 0.688 M
Monument® Dark 0.73 D
Night Sky® Dark 0.96 D
Pale Eucalypt® Dark 0.597 M
Paperbark® Light 0.421 L
Surfmist® Very Light 0.318* L
Terrain™ Dark 0.69 M
Wallaby™ Dark 0.69 M
Whitehaven® Very Light 0.23 L
Windspray® Dark 0.584 M
Woodland Grey® Dark 0.706 D
Zincalume Very Light ≤0.35* L
STAINLESS STEEL
Surfmist® Very Light 0.318* L
ARCPANEL XTREME
XTREME
*Greater deemed to satisfy insulation concessions apply to these colours when used for Class 5 to 8, 9a and 9b buildings.
General Disclaimer: Colours and availability are subiect to change, please contact ARCPANEL to confirm colours and availability prior to specification.
Notes: 1) Some colours listed above may require longer manufacturing lead times. Please contact ARCPANEL for further information.
2) COLORBOND® and colour names are registered trade marks of Bluescope Steel LimitedTM.
Panel Sizes
Eight standard panel thicknesses are available (other panel thicknesses are available upon request ):
90mm - 110mm - 130mm - 150mm - 175mm - 200mm - 210mm - 250mm
Panel Lengths
Generally straight and large curved panels can be supplied up to 24 metres in length. Longer lengths can be supplied, please
contact ARCPANEL for details.
Panel Configurations
Panels can be manufactured in straight and large curved configurations. Refer to roof type guide on page 4 for further information.
Panel Finish
The ARCPANEL ecotek panel is only available in a Trimdek topside profile and a custom orb (corrugated) underside profile.
Please refer to table 1 on page 5 for further information on colours and material types. Base metal thickness of 0.420mm and a
total coated thickness of 0.470mm is used as standard, unless otherwise stated (other steel thickness are available on request).
Panel Dimensions
ALL
As shown in the following details (figures 1 -2), the ARCPANEL ecotek roof panel can be installed from left to right (left
hand) or right to left (right hand), this is normally determined prior to undertaking of the workshop drawings. Should a
specific installation direction be required please advise ARCPANEL at time of order. Direction of lap is determined by
looking from the gutter end of the roof panel.
SINGLE MULTIPLE
LEFT HAND PANEL INSTALLATION LEFT HAND PANEL INSTALLATION DETAIL
RBS 1527-8 E
RBS 1527-9 E
Corrugated Infill
(The use of Corrugated Infill is recommended to fully seal wall/soffit junctions.
Refer to page 32 for further details).
Details: 792mm x 80mm x 0.42mm COLORBOND Surfmist ®.
Used: On internal or external walls or both.
It is attached to the wall prior to installing the lining. It is used as a
permanent barrier between the inside and outside. It is used on walls
that run at 90 degrees to the run of the roof panels.
Services
The ARCPANEL roof panels incorporate a service duct at panel joints ie. @ 762 mm approx c/c. The duct is 30 mm in
diameter and runs the full length of the panel.
Electrical fixtures are best placed on panel joins where possible, but can be positioned in any location. It is advisable that
the electrical contractor is present during the installation of the ARCPANEL roof panels.
- The electrical contractor can run wiring from supporting walls through service ducts to the required outlets.
- The underside sheet of the ARCPANEL roof panels can be drilled or a circular opening cut for inlet or outlet of wiring.
- Electrical fixtures that are not on the panel joints can be wired by drilling an opening or by pushing a heated rod
sideways or use a long auger bit and drill into the polystyrene core to the required outlet.
SELECTED TOGGLE
SIKAFLEX APPLIED
SCREWS WITH
TO UNDERSIDE OF
RECESSED HEADS
MOUNTING BLOCK.
LOCK INTO VALLEY
SECURE IN PLACE
OF ROOF SHEET
WITH TOGGLE SCREWS
INSTALLATION
OF FAN BLOCK
LED down lights can be installed directly into ARCPANEL panels with a thickness of 100mm or more. For panels less than
100mm, down lights can be surface mounted using the timber mounting block.
ARCPANEL
RBS 5128-2 A
TRIMDEK
TRIMDEK
FIXING TABLE APPLIES TO SOLAR PANELS UP TO 1700MM X 1000MM INSTALLED WITH RAILS DISTRIBUTING THE LOAD ACROSS NUMEROUS BRACKETS. FOR
PANELS OUTSIDE THIS SPEC AND INSTALLATION METHOD, PROFESSIONAL CONSULTANTS ARE REQUIRED AND JOB SPECIFIC FIXING REQUIREMENTS SHOULD
BE CALCULATED USING THE PULL OUT VALUE OF 260WSCREW.
NOTE: THE DESIGN OF THE ROOF BRACKET SYSTEM FOR A SOLAR PANEL MOUNTING APPUCATION REQUIRES THE SERVICES OF PROFESSIONAL CONSULTANTS.
THIS INFORMATION HAS BEEN PREPARED AS A SOURCE OF INFORMATION TO PROVIDE GENERAL GUIDANCE TO PROFESSIONAL CONSULTANTS AND NO WAY
REPLACES THE SERVICES OF PROFESSIONAL CONSULTANTS. NO UABIUTY CAN THEREFORE BE ACCEPTED BY Architectural Panels Pty Ltd FOR ITS USE.
WHEN PLACING OBJECTS ON ROOF: MAXIMUM DISTRIBUTED LIVE LOAD IS 0.25kPa AND REFER TO MAX ALLOWABLE DEAD LOADS ON PAGE 24.
Ultimate Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value
Limit
State
Wind Class
Design R1.7 R2.3 R2.8 R3.4 R4.0 R4.7 R5.0 R6.1
(Permissible)
Wind
Pressure
(P) (kPa) 90mm Panel 110mm Panel 130mm Panel 150mm Panel 175mm Panel 200mm Panel 210mm Panel 250mm Panel
Max Max Max Max Max Max Max Max Max Max Max Max Max Max Max Max
Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever
N2-W33 1.52 4900 1715 6200 2170 7500 2625 8100 2835 8500 2975 9500 3325 10500 3675 11400 3990
1.68 4720 1650 5980 2090 7220 2525 7820 2735 8200 2870 9200 3220 10160 3555 11020 3855
1.85 4540 1585 5760 2015 6940 2425 7540 2635 7900 2765 8900 3115 9820 3435 10640 3720
2.01 4360 1525 5540 1935 6660 2330 7260 2540 7600 2660 8600 3010 9480 3315 10260 3590
2.18 4180 1460 5320 1860 6380 2230 6980 2440 7300 2555 8300 2905 9140 3195 9880 3455
N3-W41 2.34 4000 1400 5100 1785 6100 2135 6700 2345 7000 2450 8000 2800 8800 3080 9500 3325
2.57 3840 1310 4910 1675 5880 2005 6460 2205 6760 2305 7720 2635 8500 2900 9200 3140
2.80 3680 1220 4720 1565 5660 1880 6220 2065 6520 2165 7440 2470 8200 2720 8900 2955
3.03 3520 1135 4530 1460 5440 1750 5980 1925 6280 2020 7160 2305 7900 2545 8600 2770
3.26 3360 1045 4340 1350 5220 1625 5740 1785 6040 1880 6880 2140 7600 2365 8300 2585
N4-W50 3.50 3200 960 4150 1245 5000 1500 5500 1650 5800 1740 6600 1980 7300 2190 8000 2400
3.80 3040 885 3980 1160 4820 1405 5300 1545 5600 1630 6360 1850 6980 2035 7540 2205
4.11 2880 815 3810 1075 4640 1310 5100 1440 5400 1520 6120 1725 6660 1880 7080 2010
4.41 2720 740 3640 990 4460 1215 4900 1335 5200 1415 5880 1600 6340 1730 6620 1815
4.72 2560 670 3470 905 4280 1120 4700 1230 5000 1305 5640 1475 6020 1575 6160 1620
N5-W60 5.03 2400 600 3300 825 4100 1025 4500 1125 4800 1200 5400 1350 5700 1425 5700 1425
Span Table - Non Cyclonic - Continuous (Double) Span [Y span must = (0.3X to 0.7X] TABLE 3B
Midspan deflection up to span/120 at serviceability limit state; Self weight deflection up to span/600. Maximum unsupported Spans (mm) roof panel
Ultimate Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value
Limit
State
Wind Class
Design R1.7 R2.3 R2.8 R3.4 R4.0 R4.7 R5.0 R6.1
(Permissible)
Wind
Pressure
(P) (kPa) 90mm Panel 110mm Panel 130mm Panel 150mm Panel 175mm Panel 200mm Panel 210mm Panel 250mm Panel
Max Max Max Max Max Max Max Max Max Max Max Max Max Max Max Max
Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever
N2-W33 1.52 5390 1615 6820 2045 8250 2475 8910 2670 9350 2805 9975 2990 11025 3305 12000 3600
1.68 5190 1555 6575 1970 7940 2380 8600 2575 9020 2705 9660 2895 10665 3195 11600 3480
1.85 4990 1495 6335 1895 7630 2285 8290 2485 8690 2605 9345 2800 10310 3090 11200 3360
2.01 4795 1435 6090 1825 7325 2195 7985 2390 8360 2505 9030 2705 9950 2980 10800 3240
2.18 4595 1375 5850 1750 7015 2100 7675 2300 8030 2405 8715 2610 9595 2875 10400 3120
N3-W41 2.34 4400 1320 5610 1680 6710 2010 7370 2210 7700 2310 8400 2520 9240 2770 10000 3000
2.57 4220 1230 5400 1570 6465 1880 7105 2070 7435 2165 8105 2360 8925 2595 9680 2820
2.80 4045 1140 5190 1460 6225 1755 6840 1930 7170 2020 7810 2200 8610 2425 9360 2640
3.03 3870 1055 4980 1355 5980 1625 6575 1790 6905 1880 7515 2045 8295 2255 9040 2460
3.26 3695 965 4770 1245 5740 1500 6310 1650 6640 1735 7220 1885 7980 2085 8720 2280
N4-W50 3.50 3520 880 4565 1140 5500 1375 6050 1510 6380 1595 6930 1730 7665 1915 8400 2100
3.80 3340 805 4375 1055 5300 1280 5830 1405 6160 1485 6675 1610 7325 1770 7980 1930
4.11 3165 735 4190 970 5100 1185 5610 1300 5940 1375 6425 1490 6990 1625 7560 1760
4.41 2990 665 4000 890 4905 1090 5390 1195 5720 1270 6170 1370 6655 1480 7140 1595
4.72 2815 595 3815 805 4705 995 5170 1090 5500 1160 5920 1250 6320 1335 6720 1425
N5-W60 5.03 2640 525 3630 725 4510 900 4950 990 5280 1055 5670 1130 5985 1195 6300 1260
Ultimate Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value Total R Value
Limit State
Wind Class Design
Wind
R1.7 R2.3 R2.8 R3.4 R4.0 R4.7 R5.0 R6.1
(Permissible)
Pressure
(P) (kPa) 90mm Panel 110mm Panel 130mm Panel 150mm Panel 175mm Panel 200mm Panel 210mm Panel 250mm Panel
Max Max Max Max Max Max Max Max Max Max Max Max Max Max Max Max
Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever Span Cantilever
C1-W41 3.11 3000 840 3800 1080 4600 1310 5000 1425 5500 1565 6100 1735 6500 1850 8000 2250
3.41 2840 780 3640 1010 4440 1235 4840 1350 5320 1480 5880 1635 6280 1750 7640 2110
3.71 2680 720 3480 945 4280 1165 4680 1275 5140 1395 5660 1540 6060 1650 7280 1970
4.02 2520 665 3320 880 4120 1090 4520 1200 4960 1315 5440 1440 5840 1550 6920 1830
4.32 2360 605 3160 815 3960 1020 4360 1125 4780 1230 5220 1345 5620 1450 6560 1690
C2-W50 4.62 2200 550 3000 750 3800 950 4200 1050 4600 1150 5000 1250 5400 1350 6200 1550
5.03 2090 505 2840 685 3580 865 4010 970 4400 1060 4840 1165 5180 1250 5820 1410
5.43 1980 460 2680 625 3360 785 3820 890 4200 975 4680 1085 4960 1150 5440 1270
5.84 1870 415 2520 560 3140 700 3630 810 4000 890 4520 1000 4740 1055 5060 1135
6.24 1760 370 2360 500 2920 620 3440 730 3800 805 4360 920 4520 955 4680 995
C3-W60 6.65 1650 330 2200 440 2700 540 3250 650 3600 720 4200 840 4300 860 4300 860
7.13 1580 315 2100 420 2560 510 3040 605 3380 675 3960 790 4060 810 4060 810
7.61 1510 300 2000 400 2420 480 2830 565 3160 630 3720 740 3820 760 3820 760
8.09 1440 285 1900 380 2280 455 2620 525 2940 585 3480 695 3580 715 3580 715
8.57 1370 270 1800 360 2140 425 2410 485 2720 540 3240 645 3340 665 3340 665
C4-W70 9.05 1300 260 1700 340 2000 400 2200 445 2500 500 3000 600 3100 620 3100 620
<3M 15 20 25 25 25 30 35 50
3M - 6M - 15 20 20 20 25 25 35
6M - 8M - - 10 15 15 20 20 20
8M - 10M - - - - - 10 15 15
NOTES: 1) For dead load requirements that exceed the above criteria, refer to ARCPANEL for specific engineering advice.
2) No dead load is permitted on cantilevers without specific written approval from ARCPANEL.
3) The above loads are unfactored.
150 8450 8350 8100 8100 8350 8600 8350 2670 attached to.
175 9600 9500 8500 8500 9500 9750 9500 2805
150 7950 7300 6700 6700 7300 8550 7300 2210 3 SIDES OPEN (CASE A)
175 9050 8350 7000 7000 8350 9750 8350 2310
175 6350 5750 4800 4800 5750 6925 5750 1055 1 SIDE OPEN (CASE C)
200 7100 6450 5400 5400 6450 7750 6450 1130
Version 2015.02 - Design & Detailing Manual. Always refer to local state building regulations and current safety requirements.
DESIGN DETAIL
ARCPANEL Attached Canopy Span Tables
130 5800 5200 4450 3420 5200 6325 5200 950 ATTACHED FLY OVER
C2-W50
ARCPANEL
RBS 1527-39-1 A
RBS 1527-39-2 B
1 Panel (L=762mm) 2 1.8 1.6 1.5 1.35 1.25 1.1 0.95 0.55
2 Panels (L=1524mm) 4.1 3.6 3.3 3 2.7 2.5 2.3 2.1 1.65
kN per m 2.7 2.4 2.1 1.95 1.8 1.6 1.5 1.45 1.2
Allowable lateral load (kN) Min length 762mm * Note: For straight and curved panels
FIGURE 9
EQ
EQ
RBS 1527-73 C
FIGURE 10
RBS 1527-74 B
ARCPANEL roof diaphragm action assumes there is adequate structural connection through the full length of the building
along supporting walls and beams, capable of resisting the resulting overall tension and compressive loads caused by any
ARCPANEL roof diaphragm action, as would be normally required in a traditionally braced roof.
ECOTEK
FIGURE 10. TYPCIAL SKILLION ROOF
1400
250mm 210mm
1200
1000
200mm
210mm
800 175mm
200mm
150mm
600
175mm
130mm
400 150mm
110mm
130mm
90mm
200 110mm
90mm
0
0 2000 4000 6000 8000 10000 12000
ECOTEK PANEL THICKNESS Vs STIFFNESS FOR VARYING SPANS (EI) - PER 762mm WIDE PANEL TABLE 8
90mm 110mm 130mm 150mm 175mm 200mm 210mm 250mm
Span Span Span Span Span Span Span Span
El El El El El El El El
(mm) (mm) (mm) (mm) (m) (m) (mm) (mm)
1300 22 1700 40 2100 67 2350 91 2500 107 2950 190 3400 242 3500 309
1600 27 2150 54 2700 97 3100 136 3300 162 3900 285 4500 366 4300 425
2400 43 2900 80 3750 151 4500 223 4800 266 5400 430 6050 536 6200 701
3200 59 3300 94 4100 168 5500 280 5800 329 6600 530 7350 661 8000 932
4000 73 4150 121 5000 211 6700 337 7000 394 8000 628 8850 783 9500 1090
4900 86 5100 148 6100 256 8100 390 8600 462 9650 724 10700 899 11400 1250
ECOTEK 10
ARCPANEL ecotek Panel meets the requirements for buildings assessed in bushfire prone areas
in accordance with section 2 AS 3959 - 2009 AS BAL - 29
Designated bushfire prone area means land which has been designated under a power in legislation as being
subject, or likely to be subject to bushfires.
AS 3959-2009 determines that any residence situated less than 100m from unmanaged vegetation (including
forests, woodlands, scrub, rainforests and shrubland) over one hectare in size, is deemed to be in a bushfire prone
area and all new houses or alterations and additions must meet the Bushfire Attack Level (BAL) requirements.
Note.
73 AS 5-8 rivets required to fix BAL 29 flashing
profile in to place.
RBS 1527-72 A
RBS 1527-72 A
NOTES:
SUFFIX ( * PD1 ) = PRE DRILL AND USE T17 TIMBER SCREW, PRE DRILL HOLE SIZE 5.5MM TO 5.7MM DIAMETER (DRILL BITS TO BE SUPPLIED)
SUFFIX ( * CC1 ) = 14-10 x ”X” CAN BE USED FOR STEEL 4.1MM TO 5MM IF SUITABLE CUTTING COMPOUND IS USED, REFER TO TECHNICAL SERVICES
- 14-10 x ‘X’ MM SCREWS CAN BE SUBSTITUTED FOR 14-14-’X’ MM SCREWS IN STEEL BETWEEN 1.3MM TO 4.0MM
- 14-20 x 150 MM SERIES 500 SCREW CAN BE USED FOR 110MM ECOTEK PANEL INTO 3.0MM to 12.0MM IF THERE IS NO VOID BETWEEN PANEL AND FIXING BEAM / TOP PLATE
- 14-20 x 250 MM SERIES 500 SCREW CAN BE USED FOR 210MM ECOTEK PANEL INTO 3.0MM to 12.0MM IF THERE IS NO VOID BETWEEN PANEL AND FIXING BEAM / TOP PLATE
- CLEARANCE MUST BE CHECKED TO ALLOW FOR PROTRUDING SCREW LENGTH THROUGH FIXING POINT
- FIXING BEAM / TOP PLATE MUST BE PITCHED TO SUIT THE ROOF PANEL PITCH
- FIXING TO OTHER SUBSTRATES (ALUMINIUM, STAINLESS STEEL ETC) MAY BE POSSIBLE, REFER TO TECHNICAL SERVICES
- FIXING TO STEEL SUBSTRATES LESS THAN 2.0mm, REFER TO TECHNICAL SERVICES
- FIXING SCREW TABLE REFLECTS THE RANGE OF SCREWS CURRENTLY AVAILABLE ON THE MARKET FROM BUILDEX AND POWERS FASTENERS
- Xtreme panels are compatible with stainless steel 316/2B & 445m2 as well as class 4 fixings
FIGURE 15
Stitching Screws - Top
Details: Hex Seal Class 4 - 12 - 11 x 25 - Type T17 with seal washer
Spacing: Used at 300mm centres on the top sheet lap and may be used
to attach rainwater goods
Rivets - Underside
Details: 73 AA 5-4
Spacing: Used at 300mm centres on the underside sheet lap
Tables 15 and 16 list the recommended fixing method for the ARCPANEL roof panels, however in some situations additional fixing
and/or different spacing may be required due to wind loads, structural requirements etc. An engineer should be consulted to
confirm that the above fixings will be adequate for the individual project. ARCPANEL recommends that an experienced installer
is used for fixing and finishing of the ARCPANEL roof panels.
*1 Please refer to standard fixing C - Channel details
Figure 16 shows standard components used in constructing a gable end ARCPANEL roof panel, this includes hold down
positions, stitching screws and rainwater goods.
RBS 1527-31 K
Figure 17 shows standard components used in constructing a skillion roof using the ARCPANEL roof panel, this includes,
hold down positions, stitching screws and rainwater goods.
RBS 1527-32 K
Figure 18 shows some standard ARCPANEL ecotek roof panel details. Detail A reflects recommended lapping details,
with detail B showing barge detail and detail C showing typical box gutter detail.
FIGURE 18
RBS 1527-38 J
RBS 1527-1 G
ECOTEK
(SPECIFICATION BY OTHERS)
RBS 1527-52 E
Figure 19 provides details on how the ARCPANEL ecotek roof panel is used on hipped roofs, or in the case of a verandah
roof, a 90 degree return. In the case of hipped roofs, all panels are to be cut on site, ARCPANEL does not pre cut any
roof panels. The roof is laid and marked as would be a conventional roof sheet, care is taken to include the lap when
measuring and cutting panels.
19
RBS 1527-4 F
Figure 20 shows a typical skillion roof using the C-Channel to support the panels at one end, also shown is the typical
gutter and end capping details.
20
RBS 1527-2 F
Figure 21 provides details on how to attach a plasterboard lining to the underside of the ARCPANEL ecotek panel, by
using standard metal furring channel, the plasterboard is attached in the conventional manner. The wall / ceiling junc-
tion as shown, does require a shadow joint junction.
21
RBS 1527-3 D
RBS 1527-33 E
24
Additional Note. If poly film is supplied on any ARCPANEL panels, flashings and accessories, it must be removed within one week of manufacture.
In the event that any ARCPANEL panels, flashings and accessories require storage in excess of one week, they must be fully covered and protected
from direct sunlight and weathering. Failure to remove the poly film may result in difficulty to remove the film and possible staining.
24
Additional Note. If poly film is supplied on any ARCPANEL panels, flashings and accessories, it must be removed within one week of manufacture.
In the event that any ARCPANEL panels, flashings and accessories require storage in excess of one week, they must be fully covered and protected
from direct sunlight and weathering. Failure to remove the poly film may result in difficulty to remove the film and possible staining.
Flatback
104
53
104
75
147
150
130
81
75
74
56
98
150
130
85
85
110
68
115
24
* Other gutter’s available, 200 half round, 175 (unslotted only) & Quad (unslotted only)
Additional Note. If poly film is supplied on any ARCPANEL panels, flashings and accessories, it must be removed within one week of manufacture.
In the event that any ARCPANEL panels, flashings and accessories require storage in excess of one week, they must be fully covered and protected from
direct sunlight and weathering. Failure to remove the poly film may result in difficulty to remove the film and possible staining.
ARCPANEL Certification
ARCPANEL Certification
ARCPANEL Certification
CodeMark is a building product certification scheme which supports the use of new and innovative
building products by providing a nationally and internationally accepted process for products to be
assessed for compliance with the requirements of the building codes of Australia and New Zealand.
CodeMark strengthens the entire building supply chain and gives users confidence that their building
products comply with the Building Code of Australia (or in New Zealand the New Zealand Building Code). CodeMark
certificates are accredited from internationally recognised accreditation bodies, offering increased credibility and
acceptance of a certificate holder’s CodeMark certified products.
The scheme provides confidence and certainty to regulatory authorities and the market through the issue of a Certificate
of Conformity.
How CodeMark Works: Third-party CodeMark certification bodies evaluate and certify products to ensure they
meet the specified requirements of the National Construction Code (NCC) and Building Code of Australia (BCA).
Product Certification - The Australian Building Codes Board (ABCB) is committed to ensuring best practice in the
building and construction industry. There are two product certification schemes to provide a nationally consistent quality of
materials and products; the voluntary CodeMark building product certification scheme which the ABCB owns and jointly
manages and the mandatory WaterMark plumbing and drainage product certification scheme which is managed and
administered by the ABCB.
A register of CodeMark certified products is maintained by the ABCB and listed on this website. Relevant legislation
requires building control authorities to accept CodeMark certified products.
ARCPANEL takes pride in the quality of the materials used in its products. That quality allows ARCPANEL
to offer its customers, in particular circumstances, certain warranties over and above required statutory
warranties. Whether or not those warranties apply is dependent upon factors including, without limitation,
the Panel Material, the site location and Environmental Exposure. Those warranties can at times have
extensive warranty periods up to the maximum that appear in the tables below and those warranties are
otherwise limited by ARCPANEL's Terms and Conditions.
Specific project limited warranties will be customised and determined at ARCPANEL's sole discretion on a
job by job basis. In exercising that discretion ARCPANEL will consider numerous factors particularly those
related to the:
intended use of the Product; and
location at which the Product will be used.
For example, in categorising, customising and determining warranty periods for Severe Marine or Very
Severe Marine applications ARCPANEL will consider factors present such as whether or not different
marine conditions apply such as Surf, Exposed or Calm conditions where:
Surf typically means that the near vicinity or the area is exposed to breaking surf and ocean spray.
Exposed typically means that there are expanses of salt or brackish water present in the near vicinity and
the area or the near vicinity is exposed to onshore winds, but not typically to breaking surf.
Calm typically means protected areas of salt or brackish water, including ports, harbours, bays, and river
estuaries.
Due to the ARCPANEL’s policy of continued improvements to its Products and systems, the specifications
and detailed contained in its publications may change without notice. Please refer to ARCPANEL's Terms
and Conditions which are available by contacting ARCPANEL on 1300 200 004 or by email
[email protected].
COLOUR RANGE
Basalt™
Classic Cream ™
Cottage Green
Cove™
Deep Ocean®
Dune®
Evening Haze®
Gully™
Ironstone®
Jasper®
Mangrove™
Manor Red®
Monument®
Night Sky®
Pale Eucalypt®
Paperbark®
Shale Grey®
Surfmist®
Terrain™
Wallaby™
Whitehaven®
Windspray®
Woodland Grey®
Zincalume
XTREME
Off White
STAINLESS
Surfmist®
ALUMINIUM COLOURS AVAILABLE
AQUATEK WHITE
For further information on COLORBOND® steel,
AQUATEK
the following technical bulletins LIGHTfrom
are available GREY
ARCPANEL.
AQUATEK
• Tb-1a steel roofing products DARK
– selection GREY
guide
• Tb-4 maintenance of Colorbond® steel and
Zincalume® steel
• Tb-8 flashing materials for Zincalume® steel
and Colorbond® steel sheet
• Tb-10 cut edge protection of Zinc-coated and
Zinc/aluminium alloy-coated steel
Information contained within this document is Copyright© and may not be reproduced without permission from Architectural Panels Pty Ltd (ARCPANEL).
Custom Panel, Ecotek, Firetek Panel and Aquatek Panel are registered trademarks of Architectural Panels Pty Ltd.