0% found this document useful (0 votes)
85 views1 page

Structural Drawing2018 4344 PDF

The document appears to be technical specifications or drawings containing various codes and labels (C1, C2, C3, etc.) along with references to column reinforcement and specifications. Key details include column reinforcement for multiple levels (LEVEL 7) of a structure and specifications that all dimensions are in millimeters unless otherwise noted. The document provides technical information about column reinforcement at different levels of a building/structure based on codes and specifications.

Uploaded by

sujups
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views1 page

Structural Drawing2018 4344 PDF

The document appears to be technical specifications or drawings containing various codes and labels (C1, C2, C3, etc.) along with references to column reinforcement and specifications. Key details include column reinforcement for multiple levels (LEVEL 7) of a structure and specifications that all dimensions are in millimeters unless otherwise noted. The document provides technical information about column reinforcement at different levels of a building/structure based on codes and specifications.

Uploaded by

sujups
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 CF1 CF1 CF1 CF2

C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2

CF2

CF3

CF3

CF3

CF3

CF3

CF3

CF3

CF3

CF3
C2 C2 C2 C2 C2 C3 C2 C2 C2 C2 C2 CF4

C2 C2 C3 IF2 CF4

C1 C1 C1 C1 C2 C2 C1 C1 C1 C1 CF2 CF2 IF1 IF1 CF2 CF2

IF3 IF3
C2 C2

SPECIFICATIONS
LEVEL 7
COLUMN REINFORCEMENT DETAILS FOR ALL LEVELS [1] ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED
MACHINE
[2] DIMENSIONS SHALL NOT BE SCALED OUT FROM THE DRAWING
ROOM FLOOR
C1 - 300 MM X 830 MM C2 - 300 MM X600 MM C3 -300 MM X 600 MM REMARKS [3] CONCRETE GRADE SHALL BE M25 FOR ALL STRUCTURAL ELEMENTS
LEVEL 6 [4] STEEL GRADE SHALL BE Fe 500
STAIR ROOM [5] CLEAR COVER FOR COLUMNS - 40MM, FOOTING - 50 MM
FLOOR
LEVEL 5 [7] STRUCTURE IS DESIGNED FOR - GROUND + 3 FLOOR AS PER ARCH. DRAWINGS
3 # 20 2 #25+1#20 3 # 20 [8] ALL COVER SHALL BE ENSURED BY PRECAST COVER BLOCKS MADE BY CM 1:3 DIP CURED
THIRD FLOOR
2 # 20 2 # 20 2 # 16 FOR 7 DAYS WITH BINDING WIRES EMBEDDED IN IT
LEVEL 4 [9] LARGER DIAMETER BARS SHALL BE PLACED AT OUTER ROWS/CORNERS.
FOR 2 # 20 2 # 20 2 # 16
ALL LEVELS
2 # 20 2 #25+1#20 3 # 20 SECOND FLOOR
CLEAR COVER TO COLUMNS
TIES- 8MM @ 150MM C/C TIES- 8MM @ 150MM C/C IS 40MM
3 # 20 LEVEL 3
TIES- 8MM @ 150MM C/C DIMENSIONS OF COLUMN ARE FIRST FLOOR
C1 C2 C3 SHOWN IN MM
LEVEL 2
THE HOOK OF THE LATERAL
GROUND FLOOR
LEVEL 1
M 25 GRADE CONCRETE AND
Fe 500 GRADE STEEL
GOLDEN JUBILEE PG & RESEARCH BLOCK,
LATERAL TIES
ELECTRONICS & COMMUNICATION
ARRANGEMENT
+ + + ENGINEERING,
+ COLLEGE OF ENGINEERING, TVPM
+
COLUMN & FOOTING LAYOUT
DRG. NO: 01

COMBINED FOOTING - REINFORCEMENT DETAILS


BOTTOM BOTTOM
RFT RFT
REINFORCEMENT IN THE STRIP BEAM STIRRUP REINFORCEMENT
PROJECTION PROJECTION DEPTH OF PARALLEL TO PARALLEL
C/C WIDTH OF DEPTH OF B TO L
LENGHT OF WIDTH OF FROM CENTRE FROM CENTRE FOOTING DEPTH
COLUMN STRIP FOOTING
FOOTING FOOTING OF OF SLAB @ OF STRIP
DESIGNATION C1-C2 BEAM SLAB AT BOTTOM AT BOTTOM REMARKS
L B COLUMN C1 COLUMN C2
L2 B1
OUTER EDGE
D2
BEAM D1
IN THE IN THE AT BOTTOM ONLY ONLY
MIDDLE C1 C2
(M) (M) L1 L3 D3 (M) AT COLUMN PORTION
(M) (M) (M) FOOTING FOOTING [CONTINUOUS] UNDER C1 UNDER C2
(M) (M) (M) LOCATIONS BETWEEN
SLAB SLAB FIRST LAYER [SECOND [SECOND
LAYER] LAYER]
COLUMNS X
X

4 LEG- 10MM 4 LEG- 10MM


CF2 6.60 2.40 1.50 1.50 3.60 0.40 0.25 0.45 0.90 # 12 @ 100 # 12 @ 200 # 3 - 25 # 2 - 25 # 2 - 25 # 4 - 25 DIA @ 120 MM DIA @ 180 MM
C/C C/C

4 LEG- 10MM 4 LEG- 10MM


CF3 6.00 2.40 1.50 1.50 3.00 0.40 0.25 0.45 0.90 # 12 @ 100 # 12 @ 200 # 3 - 25 # 2 - 25 # 2 - 25 # 4 - 25 DIA @ 100 MM DIA @ 150 MM
C/C C/C

Y
4 LEG- 10MM 4 LEG- 10MM
C1 C2
CF4 5.00 2.00 1.50 1.50 2.00 0.40 0.25 0.45 0.90 # 12 @ 100 # 12 @ 200 # 3 - 25 # 2 - 25 # 2 - 25 # 4 - 25 DIA @ 120 MM DIA @ 180 MM
C/C C/C

Bottom rft parallel to B Bottom rft parallel to L Section X-X Stirrup at middle location
Section Y-Y

COMBINED FOOTING DETAILS

A
COMBINED FOOTING WITH STRAP BEAM - REINFORCEMENT DETAILS
BOTTOM
COMBINED FOOTING
RFT
REINFORCEMENT IN THE STRIP BEAM STIRRUP REINFORCEMENT
PARALLEL
PROJECTION PROJECTION DEPTH OF TO B BOTTOM C1 C3
LENGHT OF WIDTH OF FROM CENTRE FROM CENTRE C/C COLUMN C/C COLUMN WIDTH OF FOOTING
DEPTH OF
DEPTH OF
C2
REINFORCEMENT
FOOTING
DESIGNATION FOOTING FOOTING OF OF C1-C2 C2-C3 STRIP BEAM SLAB @ STRIP BEAM PARALLEL TO 'L' AT THE TOP REMARKS
SLAB X X
L (M) B (M) COLUMN C1 COLUMN C3 L2 (M) L3 (M) B1 (M) OUTER EDGE D1 (M) IN THE FOOTING AT BOTTOM BETWEEN MIDDLE
D2 (M) IN THE AT BOTTOM AT TOP
L1 (M) L4 (M) D3 (M) SLAB UNDER C1-C2 PORTION
FOOTING [CONTINUOUS] [CONTINUOUS] AT COLUMN LOCATIONS
COLUMN & BETWEEN
SLAB FIRST LAYER (FIRST LAYER)
LOCATION C2- C3 COLUMNS
(SECOND LAYER )

4 LEG- 10MM DIA @ 120 4 LEG- 10MM DIA A


CF1 10.20 2.20 1.50 1.50 3.60 3.60 0.40 0.20 0.45 0.90 Y12@100 Y12@200 3Y25 3Y20 3Y25 3Y20
MM C/C @ 180 MM C/C

C1- EXTERIOR C2 -INTERIOR C3-EXTERIOR

Bottom rft parallel to B Bottom rft parallel to L


Stirrup at middle location
Stirrup at column location
Section A-A Section X-X

NGL

ISOLATED FOOTING - REINFORCEMENT DETAILS


BOTTOM RFT BOTTOM RFT
DEPTH OF
LENGHT OF WIDTH OF PARALLEL TO B PARALLEL TO L
FOOTING
FOOTING FOOTING
DESIGNATION SLAB REMARKS
L B IN THE FOOTING IN THE FOOTING
D
(M) (M) SLAB SLAB
(M)

M 25 GRADE CONCRETE AND


Fe 500 GRADE STEEL

IF1 3.0 3.0 0.6 # 16 @ 100 # 16 @ 100 PCC 1:4:8 , 100 MM THICK BELOW PLINTH BEAM

Bottom rft parallel to L


FOOTING WITH 100MM PROJECTION
AFTER WELL COMPACTION OF GOLDEN JUBILEE PG & RESEARCH BLOCK,
UNDERLYING SOIL.

ELECTRONICS & COMMUNICATION


Height of lift well, as per
lift specification
BOTTOM LEVEL OF FOOTING IS 2.0 M
FROM EXISTING GL.

IF2 2.8 2.8 0.6 # 16 @ 120 # 16 @ 120 PEDESTAL ENGINEERING,


@ 2.0m BELOW NGL.

PEDESTAL OF SIZE PROJECTING 7.5CM


COLLEGE OF ENGINEERING, TVPM
Lift well base slab constructed along with the
FROM FACE OF COLUMN -8 NUMBERS CF4 footing slab

OF 12 # BARS AS MAIN RFT. PROVIDE Bottom rft parallel to B


LINKS OF 8 # @ 200 MM C/C.
IF3 1.8 1.5 0.5 # 12 @ 120 # 12 @ 120
PROVIDE PEDESTAL TOP AT SAME
LIFT WELL DETAILS
COLUMN & FOOTING DETAILS
LEVEL AS PLINTH BEAM TOP ie. 150mm
BELOW FGL
DRG. NO: 02
ISOLATED FOOTING DETAILS

PB3 PB3 PB3 PB3 PB3 PB3 PB3 PB3 PB3 PB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
PB2

PB2

FB3
PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

FB2

FB2
FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2
FB3 FB3 FB3 FB3 FB3 FB3 FB3
FB3
PB4 PB4
FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
PB3 PB3 PB3 PB3 PB3 PB3 PB3 PB3 PB3 PB3 FB3 FB3
FB2
FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2
PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

PB2

FB2

FB3

FB3
PB3 PB3 PB3 PB3 PB2 PB3 PB3 PB3 PB3 PB3 FB3 FB3 FB3 FB3 FB2 FB3 FB3 FB3 FB3
FB3

FB3
FB2
PB2

FB2

PB4 FB3
FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1
FB2 FB3
PB1

PB1

PB1

PB1

PB1

PB1

PB1

PB1

PB1

PB4 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3


PB2

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1
FB2

FB2

PB2 PB2

PB3 PB3 PB3 PB3 PB2 PB3 PB3 PB3 PB3 FB3 FB3 FB3 FB3 FB2 FB2 FB3 FB3 FB3 FB3
FB3
PB3

PB3

FB2

FB2

FB3 FB3
FB3

PB3 FB2 FB2

LEVEL 7
PLINTH BEAM REINFORCEMENT DETAILS SPECIFICATIONS MACHINE
ROOM FLOOR
[1] ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED LEVEL 6
LONGITUDINAL REINFORCEMENT STIRRUP REMARKS
SIZE [2] DIMENSIONS SHALL NOT BE SCALED OUT FROM THE DRAWING STAIR ROOM
GRADE BEAM
NAME
( WIDTH X DEPTH) [3] CONCRETE GRADE SHALL BE M25 FOR ALL STRUCTURAL ELEMENTS FLOOR
MM X MM
BR1-THROUGH OUT
BR2-NEAR MID SPAN
TR1-THROUGH OUT
TR2-NEAR SUPPORT ST1-NEAR SUPPORT
ST2- @ OTHER [4] STEEL GRADE SHALL BE Fe 500 LEVEL 5
THE SPAN THE SPAN LOCATION
[5] CLEAR COVER FOR PLINTH BEAMS - 30 MM & FLOOR BEAMS - 25 MM
THIRD FLOOR
PB1 300 X 450 3# 25 2 # 16 3 # 25 2 # 16 2L-# 8 @ 150 2L # 8 @ 200
[7] STRUCTURE IS DESIGNED FOR - GROUND + 3 FLOOR AS PER ARCH. DRAWINGS
LEVEL 4
[8] ALL COVER SHALL BE ENSURED BY PRECAST COVER BLOCKS MADE BY CM 1:3 DIP CURED
PB2 300 X 450 3# 25 **** 3 # 25 **** 2L-# 8 @ 150 2L # 8 @ 200
FOR 7 DAYS WITH BINDING WIRES EMBEDDED IN IT SECOND FLOOR

PB3 300 X 450 2 # 20 1 # 20 2 # 20 1 # 20 2L-# 8 @ 150 2L # 8 @ 200


[9] LARGER DIAMETER BARS SHALL BE PLACED AT OUTER ROWS/CORNERS.
LEVEL 3

PB4 300 X 450 2 # 16 1 # 16 2 # 16 1 # 16 2L-# 8 @ 150 2L # 8 @ 200 FIRST FLOOR

LEVEL 2

GROUND FLOOR
LEVEL 1

FLOOR BEAM REINFORCEMENT DETAILS

LONGITUDINAL REINFORCEMENT STIRRUP REMARKS

GRADE BEAM
SIZE
( WIDTH X DEPTH)
GOLDEN JUBILEE PG & RESEARCH BLOCK,
NAME
MM X MM
BR1-THROUGH OUT
THE SPAN
BR2-NEAR MID SPAN
TR1-THROUGH OUT
THE SPAN
TR2-NEAR SUPPORT ST1-NEAR SUPPORT
ST2- @ OTHER
LOCATION
ELECTRONICS & COMMUNICATION
2L-# 8 @ 150 2L # 8 @ 200
IN TWO LAYERS ENGINEERING,
FB1 300 X 600 3# 25 2 # 16 3 # 25 2 # 16 WITH 25 MM SPACER
BAR
COLLEGE OF ENGINEERING, TVPM
FB2 300 X 600 3# 25 **** 3# 25 **** 2L-# 8 @ 150 2L # 8 @ 200

FB3 230 X 450 2 # 20 1 # 20 2 # 20 1 # 20 2L-# 8 @ 150 2L # 8 @ 200


BEAM LAYOUT & DETAILS
DRG. NO: 03

TR1+ TR1+ TR2 TR1+ TR2


TR1 TR1 TR1+
TR2 TR2

ST1 ST1 ST2 BR2 ST1


BR1 BR1
BR2 0.3 L1 or Ld whichever is more 0.3 L2 or Ld whichever is more 0.3 L2 or Ld whichever is more
0.3 L1 or Ld whichever is more

L1 L2 LANDING SLAB OF THICKNESS 180 MM


TYPICAL BEAM REINFORCEMENT DETAILS

MM
180
SS
NE
# 8@ 200 [ DISTRIBUTION STEEL] ICK FB3 BEAM
TH
B OF
LA
TS
W AIS
0.3 L 1 0.3 L 2
0.1 L 1
TOP RFT.

BOTTOM RFT.
0.25 L 1 0.25 L 2 # 12 @ 120 [MAIN BAR] M25 & Fe500
EDGE BEAM CLEAR COVER - 20 MM
0.15 L1 INTERMEDIATE BEAM
# 12 @ 120 [MAIN BAR]
L1 L2

FB3 BEAM
TYPICAL SLAB LAYOUT

TYPICAL STAIR DETAILS


SLAB REINFORCEMENT DETAILS IN ALL FLOORS

@ SUPPORT [TOP RFT] @ MID SPAN LOCATION [BOTTOM RFT]


THICKNESS
SLAB NAME TYPE REMARKS
(mm ) SUPPORTING L SUPPORTING ALONG SHORTER ALONG LONGER
BEAM BEAM SPAN SPAN

ALL SLABS TWO WAY 120 8 # @ 150 8 # @ 150 8 # @ 150 8 # @ 150

TOILET SUNKEN 8 # @ 150 8 # @ 150 8 # @ 150 8 # @ 150 CLEAR COVER


TWO WAY 130 20 MM
SLABS
M25 & Fe500

MACHINE FLOOR
TWO WAY 150 8 # @ 150 8 # @ 150 8 # @ 150 8 # @ 150
SLAB

DETAILS OF LINTEL RFT @ 2.1M HEIGHT


LINTEL SPAN OF SIZE [MM]
BOTTOM RFT TOP RFT STIRRUP RFT REMARKS
NAME LINTEL

2L - #8 @ 200
8#@
L1 UPTO 3M 230 X 150 3#12 3#12
M25 & Fe500 GOLDEN JUBILEE PG & RESEARCH BLOCK,
200 CLEAR COVER - 20MM
D
ELECTRONICS & COMMUNICATION
75

L2 3M - 5M 230 X 230 2#16 + 1#12 2#16 + 1#12 2L - #8 @ 200


CONSIDERING 1M
BRICKWALL OVER ENGINEERING,
LINTEL
600 L3 5M - 7M 230 X 300 2#16 + 1#12 2#16 + 1#12 2L - #8 @ 200 COLLEGE OF ENGINEERING, TVPM

W
TYPICAL LINTEL & SUNSHADE DETAIL
SLAB, STAIRCASE & LINTEL DETAILS
DRG. NO: 05

FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3

FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
FB3
FB2

FB2

FB3

FB3
FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB3
FB3
FB3
FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
FB2

FB3
FB3

FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
FB2
FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3

FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3
FLOOR BEAM REINFORCEMENT DETAILS
FB3
FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB3 FB3 FB3 FB3 FB3 FB3 FB3


FB3 LONGITUDINAL REINFORCEMENT STIRRUP REMARKS
SIZE
GRADE BEAM
( WIDTH X DEPTH)
FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 FB3 NAME
MM X MM
BR1-THROUGH BR2-NEAR MID TR1-THROUGH OUT ST1-NEAR ST2- @ OTHER
FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

FB2

TR2-NEAR SUPPORT
OUT THE SPAN SPAN THE SPAN SUPPORT LOCATION

IN TWO LAYERS
FB1 300 X 600 3# 25 2 # 16 3 # 25 2 # 16 2L-# 8 @ 150 2L # 8 @ 200 WITH 25 MM
FB3 FB3 FB3 FB3 FB2 FB3 FB3 FB3 FB3 FB3 SPACER BAR
FB3
FB2 300 X 600 3# 25 **** 3# 25 **** 2L-# 8 @ 150 2L # 8 @ 200

FB3 FB3 FB3 FB3 FB2 FB3 FB3 FB3 FB3 FB3
FB3 230 X 450 2 # 20 1 # 20 2 # 20 1 # 20 2L-# 8 @ 150 2L # 8 @ 200
FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB1

FB3 FB3 FB3 FB3 FB2 FB2 FB3 FB3 FB3 FB3

GOLDEN JUBILEE PG & RESEARCH BLOCK,


ELECTRONICS & COMMUNICATION
ENGINEERING,
COLLEGE OF ENGINEERING, TVPM

BEAM LAYOUT & DETAILS


DRG. NO: 04