Blowdown Tanks: Installation Design Specifications

Blowdown tanks are vessels that collect and cool boiler blowdown water. They are installed with the flash steam outlet at the top to retain blowdown and allow it to cool before release. Optional accessories include cooling control valves, thermometers, and vent condensers. Blowdown tanks come in various sizes to suit different boiler pressures and horsepower ranges, with carbon steel or stainless steel construction and ASME code compliance. Dimensions and specifications can be customized for customer needs.

Uploaded by

Jose Guerra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views1 page

Blowdown Tanks: Installation Design Specifications

Blowdown tanks are vessels that collect and cool boiler blowdown water. They are installed with the flash steam outlet at the top to retain blowdown and allow it to cool before release. Optional accessories include cooling control valves, thermometers, and vent condensers. Blowdown tanks come in various sizes to suit different boiler pressures and horsepower ranges, with carbon steel or stainless steel construction and ASME code compliance. Dimensions and specifications can be customized for customer needs.

Uploaded by

Jose Guerra
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BLOWDOWN TANKS

INSTALLATION DESIGN SPECIFICATIONS


The vessel should be installed with the flash steam outlet (5) at the top as Design Pressure: 100 PSIG
shown.
Design Temperature: 450ºF
OPTIONAL ACCESSORIES Design Code: ASME Sect VIII, Div. I, latest revision
● Self operating thermostatic cooling control valve Material of Construction: Carbon Steel (optional stainless steel)
● Thermometer
● Vent Condenser
Notes:
● Dimensions can be modified to suit customer requirements.
FEATURES ● Larger sizes and selections for higher boiler pressures are available
● Internal weir assembly retains blowdown and allows it to cool to
upon request
atmosphere, saving on cooling water.
● Baffled inlet extends tank life
● Standard inspection cover

DIMENSIONS (All dimensions in inches)


Inspect. Cold Temp. Gauge
Nominal Drain Inlet Vent Outlet Therm. Weight
Model A B C Cover Water Sensor Glass
Boiler HP 3 4 5 6 7 (Lbs.)
1 2 8 9
BDT-25 5-25 18 30 8 4x6 3/4 1-1/2 1-1/2 3 3 1/2 1-1/2 1/2 230
BDT-50 26-50 24 39 8 4x6 3/4 1-1/2 1-1/2 3 3 1/2 1-1/2 1/2 441
BDT-100 51-100 30 46 8 12 x 16 3/4 1-1/2 2 4 4 1/2 1-1/2 1/2 661
BDT-200 101-200 36 44 8 12 x 16 3/4 1-1/2 2 4 4 1/2 1-1/2 1/2 772
BDT-400 201-400 36 53 8 12 x 16 3/4 1-1/2 2 4 4 1/2 1-1/2 1/2 904
BDT-750 401-750 42 60 8 12 x 16 3/4 1-1/2 2 4 4 1/2 1-1/2 1/2 1102
BDT-3000 751-3000 48 69 8 12 x 16 3/4 1-1/2 2 4 4 1/2 1-1/2 1/2 1433