0% found this document useful (0 votes)
44 views

Project: LOT15 Calc - By. - Subject: Pilecap Design 40Sp600 Date: 11/9/2018

1. This document provides the design of a pile cap with dimensions of 6900mm x 11400mm x 2000mm supporting 600mm diameter piles with a capacity of 2700kN each. 2. Sectional checks are performed to check shear capacity and determine required shear reinforcement. Minimum shear links of 3T10 bars spaced at 400mm are required. 3. Longitudinal reinforcement of 6T16 bars spaced at 250mm are required at the bottom and top of the pile cap.

Uploaded by

WRay Tan
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views

Project: LOT15 Calc - By. - Subject: Pilecap Design 40Sp600 Date: 11/9/2018

1. This document provides the design of a pile cap with dimensions of 6900mm x 11400mm x 2000mm supporting 600mm diameter piles with a capacity of 2700kN each. 2. Sectional checks are performed to check shear capacity and determine required shear reinforcement. Minimum shear links of 3T10 bars spaced at 400mm are required. 3. Longitudinal reinforcement of 6T16 bars spaced at 250mm are required at the bottom and top of the pile cap.

Uploaded by

WRay Tan
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

PROJECT: LOT15 CALC.BY.

SUBJECT: PILECAP DESIGN 40SP600 DATE: 11/9/2018

fcu 35 N/mm2
fy 460 N/mm2
Width,b 11400 mm
Length 6900 mm Pile Size 600 mm
Thickness 2000 mm Pile Capacity 2700 kN
d 1875 mm F.O.S. 1.5

DIRECT SHEAR
Ultimate Av vc 0.8fcu0.5
Shear Shear Eff. Width, b V
Sectional Shear As100/bd fcu/25 400/d Enhance Remark
kN kN mm mm N/mm2 N/mm2 N/mm2
v<0.5vc; Provide v<0.5vc; Provide
1 15741 23611.5 11400 0.286 1.4 1 278 13 6.3 4.73 1.10 Minimum Links Minimum Links
X-DIR 4
2 4740 7110 11400 0.286 1.4 1 400 9 4.4 4.73 0.33 v<0.5vc; Provide v < vc + 0.4 ; Provide
X-DIR Minimum Links Minimum Links 0
3 7600 11400 11400 0.286 1.4 1 300 13 5.8 4.73 0.53 v<0.5vc; Provide Increase Depth
X-DIR Minimum Links 0
4 12169 18253.5 11400 0.286 1.4 1 450 8 3.9 4.73 0.85 v<0.5vc; Provide
X-DIR Minimum Links 0 0
11400 0.286 1.4 1 300 13 5.8 4.73 0.00 0

v < vc + 0.4 ; Provide


5 9328 13992 11400 0.286 1.4 1 1540 2 1.1 4.73 0.65 Minimum Links
Y-DIR
6 7600 11400 11400 0.286 1.4 1 1720 2 1.0 4.73 0.53 v < vc + 0.4 ; Provide
Y-DIR Minimum Links

Y-DIR

With reference to the sectional checks, area of shear reinforcement to be provided is as follow:
v<0.5vc; Provide Minimum Links
Section Eff. Width = 11400 mm
Section Eff. Depth = 1875 mm

Remark
Asv/Sv = (0.4 x bv) /0.87 fy 11.394
Provide 10 @ 400 mm 3 T 10
Asv mm2 471
Sv = Asv / 11.394 mm 41 REDUCE
0.75d mm 1406 OK

LONGITUDINAL BARS
Check
Beam Depth 1875 >750mm Provide Longitudinal Bars
Beam Breadth 11400
Adopted b 500
Bar Spacing, Sb 250
Minimum Bar Size 16

PILECAP DESIGN SUMMARY

Pilecap dimension (length x width x thickness) = 6900mm x 11400mm x 2000mm


Bottom reinforcement = T32 @ 150
Top reinforcement = T20 @ 150
Shear Links = Provided 3T10 @ 400
Longitudinal reinforcement = Provided 6T16 @ Both Sides