Pressure Drop Calculations - BST-001 Flow:.25m3/hr Density:.904 Kg/m3 Viscocity:. 457 CP

This document provides calculations for pressure drop through a strainer under clean and 50% clogged conditions. Key parameters include a flow rate of 0.25 m3/hr, liquid density of 0.904 kg/m3, and viscosity of 4.57 cp. The pressure drop is calculated to be 47.921 kg/cm2 for clean conditions and 107.823 kg/cm2 for 50% clogged conditions.

Uploaded by

Assure Turbines
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Pressure Drop Calculations - BST-001 Flow:.25m3/hr Density:.904 Kg/m3 Viscocity:. 457 CP

This document provides calculations for pressure drop through a strainer under clean and 50% clogged conditions. Key parameters include a flow rate of 0.25 m3/hr, liquid density of 0.904 kg/m3, and viscosity of 4.57 cp. The pressure drop is calculated to be 47.921 kg/cm2 for clean conditions and 107.823 kg/cm2 for 50% clogged conditions.

Uploaded by

Assure Turbines
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Pressure Drop Calculations - BST-001

Flow :.25m3/hr
Density :.904 Kg/m3
Viscocity:. 457 Cp

Process At 100% Clean At 50% Clogged


Strainer Pipe Screen Condition Condition
Parameters
Outside
Size(mm) 100 11.43 Diameter of Screen(cm) 60.00 p - Density of Liquid in gm/cm3 0.904 0.904
Diameter(cm)
Basket
Type Pipe Schedule(Sch) STD Length of Screen(cm) 100.00 μ - viscosity of Liquid in gm/cm-s 4.570 4.570
Strainer

Surface Area
Class Rating 150 Thickness (cm) 0.602 18849.00 Flow in Cm3/sec 6944.250 6944.250
of Screen(SAS) (cm2) at Clean Condition

V - Superficial Velocity of fluid


Surface Area of Screen 1t 50%
Inside Diameter 10.2 9424.50 based upon the gross area of 1.906 3.812
Clogged
the screen cm/sec
Net Area of Screen used for filtering (cm2)
Area of Pipe 82.1 3643.32 V/α = 9.861 19.722
at Clean Condition
Net Area of Screen used for filtering @ 50%
1821.66 (p/μ) = 0.198 0.198
Clogged (cm2)

Ratio at Clean Condition 44.35 Re - Reynolds No=D*(V/α)*(p/μ) 0.038 0.076

C - Coefficient of discharge
Ratio at 50% Clogged 22.18 0.030 0.040
(From Perry page no. 5-40)

Q - % opening in 80 Wire Mesh 37.90 g - Gravitational force cm/sec2 981.000 981.000

K - Velocity Head Loss =


P- Perforation (5mm Hole,6.5mm pitch) 51.00 28628.735 16103.663
(1/(C*C) * (1-(α*α)/(α*α)))
Pressure Drop (ΔP) =
D - Opening Width (cm) 0.02 47.921 107.823
(K*p*V*V)/2*g
Pressure Drop (ΔP) Inches of
α - Effective opening area mmSq 0.19 18.867 42.450
Water

Pressure Drop (ΔP) Kg/cm2(g) 0.047 0.106

Pressure Drop (ΔP) mBar 46.069 103.656