Conclusion and Recommendation

Based on an experiment using a fixed-bed of activated carbon from coconut shell to purify dye solutions, the performance depends on factors like bed height, column diameter, residence time, breakthrough curve, and time to breakthrough. There are recommendations for improving the experiment, such as using one method to measure density, using cheese cloth over filter paper, positioning the eyes parallel to scales, controlling solution flow, using calibrated equipment, and increasing bed height for higher adsorption capacity.

Uploaded by

Judy Ann Bose
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
156 views

Conclusion and Recommendation

Based on an experiment using a fixed-bed of activated carbon from coconut shell to purify dye solutions, the performance depends on factors like bed height, column diameter, residence time, breakthrough curve, and time to breakthrough. There are recommendations for improving the experiment, such as using one method to measure density, using cheese cloth over filter paper, positioning the eyes parallel to scales, controlling solution flow, using calibrated equipment, and increasing bed height for higher adsorption capacity.

Uploaded by

Judy Ann Bose
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

CONCLUSION

Based from the results of the experiment, it is concluded that the performance of a fixed-bed
of activated carbon from coconut shell to purify or cleanse varying concentrations of dye
solution, knowing the isotherm that best fits the data, depends upon a several factor such as
adsorption bed height, column diameter, residence time of the influent, breakthrough curve
and the time required to achieve the breakthrough.

RECOMMENDATION

In this experiment, there are several recommendations that can be applied to get better data
and results, thus the experiment can be done systematically and precisely. These
recommendations are the following:

a. To get accurate data, only one method should be used in getting the density.
b. Better to use a cheese cloth than a filter paper.
c. In taking the reading, the eyes must be parallel to the scale in order to prevent error.
d. Control the solution poured in the burette so that the bed of the activated carbon will
be compact.
e. Use calibrated apparatus to get precise result.
f. Increase the bed height for higher adsorption capacity. (Nabasa ko sa results and
discussion to ate. Ok lang bang ilagay dun? Just asking. hehe)