Rebuild BCD

The document describes troubleshooting steps taken to rebuild the BCD on a server called MVNSQL01. 1. The server was unable to boot into normal mode or safe mode. Bootrec commands were run to fix the MBR and boot sector, but /ScanOS did not find the OS drive. 2. Running /RebuildBCD returned an error related to the wrkrn.sys file. Renaming this file allowed the server to boot into normal mode. 3. A Tier 4 engineer then took over to complete the troubleshooting with the server booted into normal mode.

Uploaded by

rockysheddy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
125 views

Rebuild BCD

The document describes troubleshooting steps taken to rebuild the BCD on a server called MVNSQL01. 1. The server was unable to boot into normal mode or safe mode. Bootrec commands were run to fix the MBR and boot sector, but /ScanOS did not find the OS drive. 2. Running /RebuildBCD returned an error related to the wrkrn.sys file. Renaming this file allowed the server to boot into normal mode. 3. A Tier 4 engineer then took over to complete the troubleshooting with the server booted into normal mode.

Uploaded by

rockysheddy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Rebuild BCD 

Troubleshooting Performed: 

============================================================ 

1 We logged onto the “VCENTER01” (Site ‐ Blue Fox ‐ Monitoring Only) & accessed the Resource 

“MVNSQL01”. 

          ‐ LKGC 

          ‐ Safe Mode with Networking 

          ‐ Safe Mode 

  All not working 

  

2 Added the ISO in the boot options & rebooted the machine. 

  

3 Ran startrep which completed successfully but did not help for reboot 
 

    

4 Ran below mentioned bootrec commands 

        ‐ /FixMbr 

                    ‐ Successfully completed 

        ‐ /FixBoot 

                    ‐ Successfully completed 

        ‐ /ScanOS:‐ Did not found the OS drive 

        ‐ /RebuildBcd 

                    bcdedit /export C:\BCD_Backup 

                            c: 

                            cd boot 

                            attrib bcd ‐s ‐h ‐r 

 
                            ren c:\boot\bcd bcd.old 

                            bootrec /RebuildBcd 

  

5 Got below mentioned error 

Windows\System32\drivers\wrkrn.sys 

Status: 0xc0000098 

Info: Windows failed to load because a critical system drive is missing or corrupt. 

  

6 Again login back to the recovery console & renamed below mentioned file 

  

        ‐ F:\Windows\System32\drivers\wrkrn.sys to wrkrn.old 

  

7 Rebooted in    Normal Mode 
 

  

8 Eric (Tier 4) took over once the server booted in normal mode. 

  

If you have any queries and concerns kindly revert. 

  

Error Observed 

============================================================ 

Error1: Windows failed to start. A recent hardware or software change might be the 

cause. To fix the problem: 

  

1. Insert your Windows installation disc and restart your computer. 

2. Choose your language settings, and then click "Next". 

 
3. Click "Repair your computer". 

  

If you do not have this disc, contact your system administrator or computer 

manufacturer for assistance. 

  

Status: 0xc0000225 

Info: The boot selection failed because a required device is inaccessible. 

  

Error 2: 

Windows\System32\drivers\wrkrn.sys 

Status: 0xc0000098 

Info: Windows failed to load because a critical system drive is missing or corrupt. 

  
 

Server Information: 

============================================================ 

MVNSQL01 

  

============================================================ 

  

  