0% found this document useful (0 votes)
152 views

Glulam Span Table

This document provides span tables for glulam beams and rafters made according to the BS EN 14080:2013 production standard. It summarizes the available cross-section sizes and permissible horizontal and sloped spans for simply supported ridge beams, eaves beams, purlins, floor beams, and rafters under various loading and support conditions. The span tables are based on the strength class GL30c and other design standards. Lilleheden glulam from Denmark is available through a national stockist network and weekly deliveries throughout the UK.

Uploaded by

martinror
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views

Glulam Span Table

This document provides span tables for glulam beams and rafters made according to the BS EN 14080:2013 production standard. It summarizes the available cross-section sizes and permissible horizontal and sloped spans for simply supported ridge beams, eaves beams, purlins, floor beams, and rafters under various loading and support conditions. The span tables are based on the strength class GL30c and other design standards. Lilleheden glulam from Denmark is available through a national stockist network and weekly deliveries throughout the UK.

Uploaded by

martinror
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Span Tables 2016

Glulam – Made in Denmark

Valid from July 2016

TION STAN
UC
DA
W PROD

RD
13 ·
NE

20

BS :
EN 14080
·


BS EN 14080:2013
Production Standard

Since August 2015 the


production standard for Glulam,
BS EN 14080:2013 has been
mandatory for all manufacturers of
Glulam for load bearing structures.

NEW STANDARD GLULAM GL28cs and GL30c


The revised standard provides com- Strength [MPa] GL28cs GL30c
mon European requirements for the Bending strength f m,k 28 30
production of laminated timber Tensile strength f t,0,k 19.5 19.5
and strength classes for Glulam. f t,90,k 0.5 0.5
Compression strength f c,0,k 24.5 24.5
Designers need to be aware of the f c,90,k 2.5 2.5
strength classes available on Shear strength f v,k 3.5 3.5
the UK market. The strength classes Rolling shear strength f r,k 1.2 1.2
are now GL28cs and GL30c.
Stiffness Properties [MPa] GL28cs GL30c

Although the strength classes have Modulus of elasticity E 0,mean 12500 13000

changed you still get the same E 0,05 10400 10800

quality product from Lilleheden. E 90,mean 300 300


E 90,05 250 250
Shear modulus G mean 650 650
G 05 540 540
Rolling shear modulus G r,mean 65 65
G r,05 54 54

Density [kg/m3] GL28cs GL30c


Density ρk 390 390
Your best choice for Glulam.
ρmean 430 430

2 Span Tables 2016


Span tables
Simply supported beams

Basis of design
Horizontal beams
Section Ridge beam / Eaves beam / Purlin Floor beam Standards:
size Load width [m] Load width [m] BS EN 1990:2002+A1:2005 + NA
[mm] BS EN 1991-1-1:2002 + NA
2.0 2.5 3.0 3.5 4.0 4.5 2.0 2.5 3.0 3.5 4.0 4.5
BS EN 1991-1-3:2003 + NA
90 x 225 4.2 3.9 3.7 3.5 3.3 3.2 3.6 3.3 3.1 2.9 2.6 2.3
BS EN 1995-1-1:2004+A2:2014 + NA
90 x 270 5.1 4.7 4.4 4.2 4.0 3.9 4.3 4.0 3.8 3.6 3.1 2.8
90 x 315 6.0 5.5 5.2 5.0 4.7 4.5 5.1 4.7 4.4 4.2 3.7 3.3 Strength class:
90 x 360 6.8 6.3 6.0 5.7 5.4 5.2 5.8 5.4 5.1 4.8 4.2 3.7 GL30c acc. to BS EN 14080:2013
90 x 405 7.7 7.1 6.7 6.4 6.1 5.9 6.5 6.1 5.7 5.3 4.8 4.2
115 x 225 4.6 4.3 4.0 3.8 3.6 3.5 3.9 3.6 3.4 3.2 3.1 2.9 Dead loads:
115 x 270 5.5 5.1 4.8 4.6 4.4 4.2 4.7 4.7 4.4 4.2 4.0 3.9 Roof: 0.7 kN/m2 on slope
115 x 315 6.4 6.0 5.7 5.4 5.1 4.9 5.5 5.1 4.8 4.6 4.4 4.2 Floor: 0.5 kN/m2
115 x 360 7.4 6.9 6.5 6.2 5.9 5.7 6.3 5.8 5.5 5.2 5.0 4.7
115 x 405 8.3 7.7 7.3 6.9 6.6 6.4 6.9 6.6 6.2 5.9 5.6 5.3 Imposed loads:
115 x 450 9.2 8.6 8.1 7.7 7.4 7.1 7.4 7.1 6.8 6.6 6.3 5.9 Roof: 0.6 kN/m2 on plan
115 x 495 10.1 9.4 8.9 8.5 8.1 7.8 8.0 7.6 7.3 7.1 6.9 6.5 Floor: 1.5 kN/m2
Partitions: 0.5 kN/m2
140 x 225 4.9 4.5 4.3 4.1 3.9 3.7 4.1 3.8 3.6 3.4 3.3 3.1
140 x 270 5.9 5.5 5.2 4.9 4.7 4.5 5.0 4.6 4.4 4.1 4.0 3.8
Service class: 1
140 x 315 6.9 6.4 6.0 5.7 5.5 5.3 5.9 5.4 5.1 4.9 4.7 4.5
140 x 360 7.8 7.3 6.9 6.6 6.3 6.0 6.6 6.2 5.9 5.6 5.3 5.1 Limiting values for deflections:
140 x 405 8.8 8.2 7.8 7.4 7.1 6.8 7.2 6.9 6.6 6.3 6.0 5.8 wfin ≤ span/250
140 x 450 9.8 9.1 8.6 8.2 7.9 7.6 7.7 7.4 7.1 6.9 6.7 6.4
140 x 495 10.7 10.0 9.5 9.0 8.7 8.3 8.3 7.9 7.6 7.4 7.2 7.0 Fundamental frequency
residential floor:
f1 ≥ 8 Hz
Rafters

Section Roof pitch 0˚-15˚ Roof pitch 16˚-30˚ Lateral restraint to top flange:
size Centres [m] Centres [m] Max distance between lateral
[mm] 2.0 2.5 3.0 3.5 4.0 4.5 2.0 2.5 3.0 3.5 4.0 4.5 support 15 x section width.
90 x 225 4.3 4.0 3.7 3.5 3.4 3.2 4.0 3.7 3.5 3.3 3.2 3.0
Fire requirement:
90 x 270 5.1 4.8 4.5 4.3 4.1 3.9 4.8 4.5 4.2 4.0 3.8 3.7
No fire requirement considered.
90 x 315 6.0 5.6 5.3 5.0 4.8 4.6 5.7 5.3 4.9 4.7 4.5 4.3
90 x 360 6.9 6.4 6.0 5.7 5.5 5.3 6.5 6.0 5.7 5.4 5.2 5.0 Limitation of the span tables:
90 x 405 7.8 7.2 6.8 6.5 6.2 6.0 7.3 6.8 6.4 6.1 5.8 5.6 The span tables serve as a
115 x 225 4.6 4.3 4.0 3.8 3.7 3.5 4.3 4.0 3.8 3.6 3.4 3.3 design aid but do not replace
115 x 270 5.6 5.2 4.9 4.6 4.4 4.3 5.2 4.9 4.6 4.4 4.2 4.0 structural calculations.
115 x 315 6.5 6.1 5.7 5.4 5.2 5.0 6.1 5.7 5.4 5.1 4.9 4.7
115 x 360 7.4 6.9 6.5 6.2 6.0 5.7 7.0 6.5 6.1 5.8 5.6 5.4
115 x 405 8.4 7.8 7.4 7.0 6.7 6.5 7.9 7.3 6.9 6.6 6.3 6.1
115 x 450 9.3 8.7 8.2 7.8 7.5 7.2 8.7 8.1 7.7 7.3 7.0 6.7
115 x 495 10.2 9.5 9.0 8.6 8.2 7.9 9.6 8.9 8.5 8.1 7.7 7.4
140 x 225 4.9 4.6 4.3 4.1 3.9 3.8 4.6 4.3 4.1 3.9 3.7 3.5
140 x 270 5.9 5.5 5.2 5.0 4.7 4.6 5.6 5.2 4.9 4.6 4.4 4.3
140 x 315 6.9 6.5 6.1 5.8 5.5 5.3 6.5 6.1 5.7 5.4 5.2 5.0
140 x 360 7.9 7.4 7.0 6.6 6.4 6.1 7.4 6.9 6.5 6.2 6.0 5.7
140 x 405 8.9 8.3 7.8 7.5 7.2 6.9 8.3 7.8 7.4 7.0 6.7 6.5
140 x 450 9.8 9.2 8.7 8.3 8.0 7.7 9.2 8.6 8.2 7.8 7.5 7.2
140 x 495 10.8 10.1 9.6 9.1 8.8 8.4 10.1 9.5 9.0 8.6 8.2 7.9

Permissible horizontal spans [m]

www.lilleheden.co.uk 3
Glulam – Made in Denmark
– Available here.
National network of
stockists plus weekly
deliveries throughout
mainland GB.

Glulam – Made in Denmark


Lilleheden A/S · Digital Media Centre
County Way · Barnsley S70 2JW
T: 01226 720 760 · F: 01226 720 701
[email protected] · www.lilleheden.co.uk

You might also like