Renewable Energy

Total Energy
Load Analysis Wat Quantity Hours Of / Day Demand WH
Lighting 15 10 12 1800
TV 70 1 6 420
Kipas Angin 40 8 24 7680
Kulkas 70 70 1 24 1680
11580
Converty Eff 90% 0.9
E Device 12866.67 WH
E Sc (DC Control) 14296.30 WH
E PV 15884.77 WH
PV Module Sizing
T amb 34 ℃ Nama : Derry Prakasa
NOCT 47 ℃ NRP : 07111745000009
S 1 Renewable Energy
MPP Coeff 0.005 0,5%
Pstc 150
Temp Cell 67.75 ℃
P PV 117.94 Wat
E Gen Per Module 530.72 WH
∑ Module 30 Module
E Batery 14296.3 WH
Lead Acid Batery 17870.4 WH ← Max Depth Of Decrease 80%
ESH 4.5 Hours
Autonomous Day
n 2 Day 3 ← Autonomous
E Bat Storage 42.9 KWH
Autonomous Hours 3574 Hours
Charge Storage 12 Hours
Storage Hours / day 2716 WH
1 Day Free Storage 4.7 Day