INTRODUCTION
In the MELDAS600, 60/60S Series, the user PLC development environment is supported using MELSEC
PLC development tool, which is Mitsubishi integrated FA software MELSOFT series (GX Developer), in
addition to the conventional MELDAS PLC programming tool (PLC4B) and onboard ladder tool.
This manual explains user PLC development environment using GX Developer, mainly usage specific to
MELDAS.
CAUTION
Items not described in this manual must be interpreted as "not possible".
Some screens and functions may differ depending on the NC system or its version,
and some functions may not be possible. Please confirm the specifications before
use.
General precautions
Refer to the respective manuals for details of the MELDAS series PLCs and for details of various
tools described in this manual. Refer to the MELSEC Series manual for details on the various tools
and instructions for the MELSEC Series.
(Caution)
• The version numbers are current as of the editing of this manual, but may be
updated in the future.
• GX Developer Version 8 (Model SW8D5C-GPPW) is the new name of the old
"Windows Version GPP Function Software package" (common name GPPW).
Precautions for Safety
Always read the specifications issued by the machine maker, this manual, related
manuals and attached documents before installation, operation, programming,
maintenance or inspection to ensure correct use.
Understand this numerical controller, safety items and cautions before using the unit.
This manual ranks the safety precautions into "Danger", "Warning" and "Caution".
CAUTION When the user may be subject to bodily injury or when physical
damage may occur if handling is mistaken.
Note that even items ranked as " CAUTION", may lead to major results depending on
the situation. In any case, important information that must always be observed is
described.
DANGER
Not applicable in this manual.
WARNING
Not applicable in this manual.
CAUTION
1. Items related to product and manual
For items described as "Restrictions" or "Usable State" in this manual, the instruction
manual issued by the machine maker takes precedence over this manual.
An effort has been made to describe special handling of this machine, but items that
are not described must be interpreted as "not possible".
This manual is written on the assumption that all option functions are added. Refer to
the specifications issued by the machine maker before starting use.
Refer to the Instruction Manual issued by each machine maker for details on each
machine tool.
Some screens and functions may differ depending on the NC system or its version,
and some functions may not be possible. Please confirm the specifications before
use.
2. SETUP ............................................................................................................................14
2.1 Setting up Each Tool ...............................................................................................14
2.2 RS-232C Connection Procedures...........................................................................14
2.3 Setting the CNC Parameters...................................................................................15
GX Developer
Printout
(GPPW)
General-purpose printer
RS -232C
PLC program editing ROM cassette Floppy disk drive unit DOS format FLD IC card
Ladder monitor
ROM making
New development is enabled by offline
development only.
-1-
1. PLC DEVELOPMENT ENVIRONMENT
1.2 Software Configuration
The GX Converter is a tool that carries out data conversion of GX Developer data files and the
following (Start up GX converter from the GX Developer menu as a add-on tool for GX
Developer):
• Ladder list files and comment text files output by the CLST6L
• Alarms and operator messages created by the text editor
• Data files of commercially available spreadsheet software, word processors and editors
This tool is a software package for various MELSEC support. GX Converter needs to be used
with the versions following GX Developer Version 3 (SW3D5C-GPPW). Refer to the enclosed
Operating Manual for function details.
The DOS version "CNVQ" (SW0IVD/NX-CNVQ data conversion software package) of this tool
can also be used. Refer to Appendix "OPERATION METHODS USING GPPQ" for details.
This tool converts the user PLC ladder list data developed for the PLC4B to M600, M60/60S
specification instructions and devices, and outputs the data in a ladder list format. The user
PLC ladder developed in the PLC4B can be used for M600, M60/60S Series with the GX
Developer by using the GX Converter to further convert the conversion results of this tool.
This tool runs on Windows DOS.
-2-
1. PLC DEVELOPMENT ENVIRONMENT
1.2 Software Configuration
This tool outputs the contact/coil comment data of a user PLC ladder developed for the PLC4B
in the text format of the M600, M60/M60S series device specifications. The contact/coil
comment data developed in the PLC4B can be used with GX Developer by using GX Converter
to further convert the conversion results of this tool.
This tool runs on Windows DOS.
This tool outputs a MELDAS specification ladder printout image with cross information in a text
format from the GX Developer specification ladder list and comment data.
This tool runs on Windows DOS.
-3-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
The following shows a list of GX Developer outline functions supported by the M600, M60/60S
Series.
A mark indicates functions that can be used by the M600, M60/60S Series. An r mark indicates
that the function cannot be used because it is related to "MELSEC Series" characteristic functions.
The function details during on-line are described in the next section.
List of general section functions (1) : Possible, : Limitedly possible, U : Not possible
Program type Support Remarks
Ladder
List
SFC U
MELSAP-L U
Function block U
-4-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
List of general section functions (2) : Possible, : Limitedly possible, U : Not possible
Function Menu Sub menu Support Remarks
(Project) Macro Registration macros
Macro utilize
Delete macros
Macro reference path
Printer setup
Print
Start new GX Developer session
Exit GX Developer
Edit Undo
Restore after ladder conversion
Cut
Copy
Paste
Insert line
Delete line
Insert row
Delete row
Insert NOP batch
Delete NOP batch
Draw line
Delete line
Change TC setting
Read mode
Write mode
Ladder symbol Open contact
Close contact
Open branch
Close branch
Coil
Application instruction
Vertical line
Horizontal line
Delete vertical line
Delete horizontal line
Rising pulse Instead of DEFR
Falling pulse U
Rising pulse open branch U
Falling pulse close branch U
Invert operation results U
Convert operation results to U
rising pulse
Convert operation results to U
falling pulse
Documentation Comment
Statement
Note
Statement/Note block edit
-5-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
List of general section functions (3) : Possible, : Limitedly possible, U : Not possible
Function Menu Sub menu Support Remarks
Find/Replace Find device
Find instruction
Find step no.
Find character string
Find contact or coil
Replace device
Replace instruction
Change open/close contact
Replace character string
Replace unit head I/O No. U
Replace statement/note type
List of used contact coils
List of used devices
Convert Convert
Convert (All programs being
edited)
Convert (Online change) U
View Comment
Statement
Note
Alias
Macro instruction format display
Comment format 4*8 characters
3*5 characters
Alias format display Replace device name and
display
Arrange with device and display
Toolbar
Status bar
Zoom 50%
75%
100%
150%
Specify
Auto
Project data list
Instruction list
Set the contact 9 contacts
11 contacts
Elapsed time U
Online Refer to "List of on-line section Refer to "List of on-line section
functions" functions"
-6-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
List of general section functions (4) : Possible, : Limitedly possible, U : Not possible
Function Menu Sub menu Support Remarks
Tools Check program
Merge data
Check parameter U
Transfer ROM Read U
Write U
Verify U
Write to file U
Delete unused comments
Clear all parameters U
IC memory card Read IC memory card U
Write IC memory card U
Read image data U
Write image data U
Start ladder logic test U
Set TEL data Connection U
Disconnection U
TEL data U
AT command U
Call book U
Intelligent function utility Utility list U
Customize keys
Change display color
Options Limited partly
Create start-up setting file
Window Cascade
Tile vertically
Tile horizontally
Arrange icons
Close all windows
Help CPU error U
Special relay/register U
Key operation list
Product information
Connect to MELFANSweb
-7-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
The following shows a list of GX Developer on-line functions supported by the M600, M60/60S
Series.
A mark indicates functions that can currently be used by the M600, M60/60S Series. An r mark
indicates that the function cannot be used because it is related to "MELSEC Series" characteristic
functions.
List of on-line section functions (1) : Possible, : Limitedly possible, U : Not possible
Menu Sub menu Detailed function Support Remarks
Transfer setup PC side I/F
PLC side I/F Only for QnACPU
Other station U
Network route U
Co-existence network U
route
Read from PLC Target memory
Title
File selection
Device data U
Program U
Common U
Local U
Refresh view
Free space volume
Create title U
Write to PLC Target memory
Title
File selection
Device data U
Program U
Common U
Local U
Free space volume
Create title U
Verify with PLC Target memory
Title
File selection
Program U
Refresh view
Free space volume
Create title U
Write to PLC Write the program U
(Flash ROM) memory to ROM
Write to PLC U
(Flash ROM)
Delete PLC data Target memory
Title
File selection
Refresh view
Free space volume
Create title U
Change PLC data U
attributes
PLC user data Read PLC user data U
Write PLC user data U
Delete PLC user data U
-8-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
List of on-line section functions (2) : Possible, : Limitedly possible, U : Not possible
Menu Sub menu Detailed function Support Remarks
Monitor Monitor mode ON/OFF state
Scan time display U
CPU state display
Monitor [Write mode] U
Start monitor
[All windows]
Stop monitor
[All windows]
Start monitor
Stop monitor
Change current value
monitor [Decimal]
Change current value
monitor [Hexadecimal]
Local device monitor
Device batch Device
Connect
Coil
Setting value
Current value
Monitor format : Bit & word
Monitor format : Bit
Monitor format : word
Display : 16bit integer
Display : 32bit integer
Display : Real number U
Display : ASCII character U
Value : DEC
Value : HEX
T/C set value Reference
program
Device test
Entry data monitor Device
ON/OFF/Current
Setting value
Connect
Coil
Display : 16bit integer
Display : 32bit integer
Display : Real number U
Display : ASCII character U
Value : DEC
Value : HEX
T/C setting value, Local
label Reference program
Device test
Buffer memory batch U
Monitor condition setup Device
Step No.
Monitor stop condition setup Device
Step No.
Program monitor list U
Interrupt program monitor list U
Scan time measurement U
Entry ladder monitor
Delete all entry ladder
-9-
1. PLC DEVELOPMENT ENVIRONMENT
1.3 Outline of GX Developer Functions and List of Supported Functions
List of on-line section functions (3) : Possible, : Limitedly possible, U : Not possible
Menu Sub menu Detailed function Support Remarks
Debug Device test FORCE ON
FORCE OFF
Toggle force
Device
Buffer memory U
Forced input output U
registration/cancellation
Debug U
Skip execution U
Partial execution U
Step execution U
Trace Sampling trace U
Remote operation PLC status
RUN
STOP
PAUSE U
Latch clear U
STEP-RUN U
Reset U
Operation during RUN, U
STEP-RUN
Specify execution U
destination
Keyword setup Register U
Delete U
Disable U
Clear PLC memory U
Format PLC Target memory Only internal RAM other than
memory ladder storage area.
Format Type U
Arrange PLC U
memory
Set time YY MM DD Hr. Min. Sec.
Day of week U
Specify execution U
destination
- 10 -
1. PLC DEVELOPMENT ENVIRONMENT
1.4 Memory Specifications
The M600, M60/60S series stores PLC data onto flash ROM (hereafter abbreviated to the F-ROM).
The following shows the storage area structure.
256 Kbyte
Control information area
The PLC data transferred from GX Developer are stored in either of the following two storage
methods, which differs depending on the model.
As for the transferred data, the PLC ladder code is first stored into the nonvolatile RAM area
(hereafter abbreviated to the S-RAM) designed for execution. The non-ladder PLC data are
stored into the normal RAM area (hereafter abbreviated to the D-RAM).
Write them to the F-ROM on the CNC controller side I/O screen. At power-ON of the CNC
controller, the data are transferred from the F-ROM to the S-RAM and D-RAM areas, where
they will be executed.
The transferred data are stored into the F-ROM area designed for both storage and execution.
They can also be copied to the cassette F-ROM area for maintenance purpose.
- 11 -
1. PLC DEVELOPMENT ENVIRONMENT
1.4 Memory Specifications
The following table indicates the storage areas that can be selected for the online functions
(Write to PLC, Read from PLC, Verify with PLC) of GX Developer.
Function M600 series M60/60S series
Write to PLC S-RAM Internal F-ROM
Read from PLC, S-RAM Internal F-ROM
Verify with PLC Internal F-ROM
Cassette F-ROM
- 12 -
1. PLC DEVELOPMENT ENVIRONMENT
1.4 Memory Specifications
Any of the storage areas that can be selected for the online functions (Write to PLC, Read from
PLC, Verify with PLC) of GX Developer can be specified as a [Target memory] item on the
corresponding operation screen.
Also, pressing the [Title] button displays the comment of that storage area if PLC data exists. It
is not displayed if the storage memory is not fitted or the data does not exist.
Further, pressing the [Free space volume] button displays [Total free space volume] and
[Largest continuous volume] of the selected area.
Some storage areas displayed as the target memory differ from the actual storage areas of the
CNC controller. The following tables indicates the relationships between the [Target memory]
items and storage areas.
- 13 -
2. SETUP
2.1 Setting up Each Tool
2. SETUP
2.1 Setting up Each Tool
In the M600 M60/60S Series PLC development environment, it is assumed that the various tools
are used with an IBM PC/AT compatible personal computer. Prepare each tool so that it is IBM
PC/AT compatible personal computer.
Refer to the enclosed Operating Manual (Startup) and Operating Manual for the setup and start
procedures of each tool.
Between the IBM PC/AT compatible personal computer that uses GX Developer and the CNC
controller, use an RS-232C serial cable equivalent to the one shown below in the RS-232C
connection diagram.
[Note]
The cables given in the connection diagrams of the GX Developer Operating Manual cannot be
used.
Settings such as the GPPW communication speed are not required on the NC side.
Personal
NC side
computer side
(25-pin D-SUB)
(9-pin D-SUB)
Cable
Pin Pin
Signal name connection and Signal name
No. No.
signal direction
CD 8 1 DC
SD 2 2 RD
RD 3 3 SD
DR (DSR) 6 4 ER (DTR)
SG 7 5 SG
ER (DTR) 20 6 DR (DSR)
CS (CTS) 5 7 RS (RTS)
RS (RTS) 4 8 CS (CTS)
22 9 RI
∗ The above shows a general RS-CS method connection format.
∗ The pin Nos. of dotted lines are not used.
- 14 -
2. SETUP
2.3 Setting the CNC Parameters
7 6 5 4 3 2 1 0
# (51) Data (0 0 1 0 0 0 0 0)
Bit 5 = 0
The serial port is used for communication with GX Developer.
(This serial port cannot be used concurrently with the other function.)
Bit 5 = 1
The serial port is not used for communication with GX Developer.
(When the serial port is used for another function)
7 6 5 4 3 2 1 0
# (6451) Data (0 0 1 1 0 0 0 0)
1 : GPPW mode
Use No. 6451. 0 : GPP communication disabled
1 : GPP communication enabled
[Reference] #6451 corresponds to the low side of the file register R2925.
Bit 4 = 1
The PLC development environment of GX Developer is used.
Bit 5 = 0
The serial port is not used for communication with GX Developer.
(When the serial port is used for another function)
Bit 5 = 1
The serial port is used for communication with GX Developer.
(This serial port cannot be used concurrently with the other function.)
- 15 -
2. SETUP
2.3 Setting the CNC Parameters
7 6 5 4 3 2 1 0
# (6451) Data (0 0 1 1 0 0 0 0)
0 : PLC4B mode
1 : GPPW mode
Use No. 6451.
0 : GPP communication disabled
1 : GPP communication enabled
[Reference] #6451 corresponds to the low side of the file register R2925.
Choose the PLC development environment. Independently of the setting of this bit, the currently
stored ladder of either format operates.
Note that the onboard function is inactive if the format of the currently stored ladder differs from
the environment selected here.
Bit 4 = 0
The PLC development environment of PLC4B is used.
Bit 4 = 1
The PLC development environment of GX Developer is used.
When using the PLC development environment of GX Developer, choose whether the serial
port used for communication with GX Developer will be used or not.
Bit 5 = 0
The serial port is not used for communication with GX Developer.
(When the serial port is used for another function)
Bit 5 = 1
The serial port is used for communication with GX Developer.
At this time, the onboard function is not started if bit 4 = 1.
When the GPPW serial port use selection parameter is set to "1" (enabled),
GPPW occupies the communication so communication (input/output) other than
GPPW cannot be used.
- 16 -
3. PLC PROGRAM DEVELOPMENT
- 17 -
3. PLC PROGRAM DEVELOPMENT
3.1 User PLC (Ladder) Development Procedure
Start
Determination of
machine
Determination of
CNC and PLC
specifications
Determination of the Commercially available
numbers of I/O points spreadsheet tool The data created with the
Device Name Commen t
Assignment of I/O X0 X-OT X-axis OT
commercially available
signals X1 Y-OT Y-axis OT spreadsheet tool can be
Assignment of X2 Z-OT Z-axis OT
used as ladder comment
internal relays
data.
GX Developer
Use GX Developer for
Programming programming.
After completion, download
the data through RS-232C.
Onboard
GX Developer Perform monitoring/correction
Debugging
(RAM operation) with GX Developer's online
function or onboard function.
Program correction
Printout to a commercial
Printout
printer connected with the
personal computer from GX
Developer.
Program data:
Data save onto FLD
Saved using GX Developer
Binary data:
Completion Program data Binary data Saved using I/O screen
- 18 -
3. PLC PROGRAM DEVELOPMENT
3.2 Precautions before Development
The PLC type must be set when newly creating programs, etc. Select the following CPU type when
requested to select the PLC type by the GX Developer. An error will occur during transfer of the
ladder program to the CNC controller if another PLC type is selected.
Do not set the devices when developing the ladder program for the CNC controller. Develop the
program with the device settings (No. of points, etc.) left at their default values applied when GX
Developer was started. The ladder program cannot be transferred to the CNC controller normally
when it is developed with settings other than the default values.
MELSEC-specific PLC instructions cannot be used in the ladder program development for the CNC
controller. Only PLC instructions and formats in PLC programming manual can be used.
The format, etc., are changed with some instructions. Refer to "Appendix 2. DIFFERENCES IN
DEVELOPMENT ENVIRONMENT BETWEEN PLC4B AND M600, M60/60S" for details.
- 19 -
3. PLC PROGRAM DEVELOPMENT
3.2 Precautions before Development
GX Developer allows a ladder program to be commented (with interlinear statements and notes).
They are available in two types: integrated and peripheral.
Integrated type : Can be downloaded together with a ladder program to the CNC
controller.
Peripheral type : Cannot be downloaded.
The integrated type cannot be used with the M600, M60/60S series. If it is used, a ladder program
cannot be transferred to the CNC controller properly.
Inside the M600, M60/60S series, PLC-related data are controlled and stored in the following
categories. Therefore, they are also developed in the same categories.
CAUTION
If the data transferred does not follow the file name rule, the NC will mistake
it for another data, resulting in unexpected operation, e.g. PLC program
erasure.
M1 xxxx. W PG or W CD
When data is transferred by GX Developer, its data type is distinguished by the file name.
An extension indicates a file type, and the first two characters denote a data type and a language
type.
The file name can be designated with eight characters (excluding the extension) which contain the
data type and language type.
[Note] Unusable file name
Data type : "M", "C" or "H" (alphabet)
Language type : "0" to "9" (numeral)
at the beginning of a file name are reserved on the NC side. Do not use the file name of this
combination.
- 20 -
3. PLC PROGRAM DEVELOPMENT
3.2 Precautions before Development
- 21 -
3. PLC PROGRAM DEVELOPMENT
3.4 Specifying the Connection Target
Perform the following operation from GX Developer to start the setting screen.
- 22 -
3. PLC PROGRAM DEVELOPMENT
3.5 Starting/Stopping the PLC of the CNC Controller
Perform the following operation from GX Developer to start the operation screen.
On the following screen, set "STOP" or "RUN" in the [PLC] part under [Operation] and click
[Execute]. The current status is displayed in [PLC status] under [Connection target information].
[Note] Operations other than RUN and STOP are not possible.
The operation is completed when the following dialog appears. Click [OK]. The status after
completion appears in [PLC status] on the remote operation screen displayed behind. If the status
does not change, check whether an alarm is displayed or not on the CNC controller side.
- 23 -
3. PLC PROGRAM DEVELOPMENT
3.6 Writing the PLC Program to the CNC Controller
Perform the following operation from GX Developer to start the operation screen.
As soon as a ladder is written from GX Developer to the CNC controller, the CNC controller
converts it into the CNC-specific ladder machine code. A conversion error occurs if any of the
devices and instruction formats not supported by the M600, M60/60S series is used.
At a conversion error, the CNC side ladder machine code is converted into the "NOP code", the
ladder up to the last step is transferred, and the following dialog is then displayed on the GX
Developer screen.
- 24 -
3. PLC PROGRAM DEVELOPMENT
3.6 Writing the PLC Program to the CNC Controller
When the file that resulted in a conversion error is displayed with the [File selection] tab of the
[Read from PLC] screen, the following warning appears in the title field.
"∗∗ WARNING Checksum ERROR!! ∗∗"
If you execute RUN the PLC as-is, an alarm occurs on the CNC side and the PLC does not RUN.
CAUTION
Do not read a ladder file on which a conversion error occurred into the GX
Developer side. The file may include unexpected contents to result an illegal
operation.
3.6.3 How to confirm the error step number
The PLC verification function can be used to confirm the error step. Executing verification with PLC
displays mismatches as in the following example. For details of the PLC verification function, refer to
"3.8 Verifying the PLC Programs".
Following example shows the step where CNC controller outputs a conversion error because NOP
instructions mismatched between CNC and GX Developer.
Double-click the mismatch to display and to edit the corresponding part of the GX Developer side.
<Memory> indicates the GX Developer side, and <PLC> the CNC controller side.
- 25 -
3. PLC PROGRAM DEVELOPMENT
3.7 Reading the PLC Program from the CNC Controller
Perform the following operation from GX Developer to start the operation screen.
If a ladder file with the same name already exists in the GX Developer side, following dialogue will
appear.
[Note] Choosing [Yes (Y)] in the dialogue will overwrite the GX Developer side ladder file. The
file before overwriting will be erased.
Confirm the file enough before choosing [Yes (Y)].
- 26 -
3. PLC PROGRAM DEVELOPMENT
3.7 Reading the PLC Program from the CNC Controller
The [Read from PLC] screen can also be used as a CNC controller side file listing function. Move
the scroll bar of the [File selection] tab to the right to display the write date and size of each file.
Click [Free space volume] to display the free area of the target memory.
- 27 -
3. PLC PROGRAM DEVELOPMENT
3.8 Verifying the PLC Programs
Perform the following operation from GX Developer to start the operation screen.
If verification mismatches occur, the following mismatch screen appears. Double-click the mismatch
to display the corresponding part of the GX Developer side file.
- 28 -
3. PLC PROGRAM DEVELOPMENT
3.9 Monitoring the PLC Program
(1) Display the ladder program to be monitored and move to the circuit part to be monitored.
[Note] If the ladder program being run by the CNC controller differs from the one being displayed
on GX Developer, monitoring will not result in an error but will continue.
- 29 -
3. PLC PROGRAM DEVELOPMENT
3.10 Using PLC46 Type PLC Programs
Creation
PLC4B/LIST4B
LIST4B output
ladder list
zzzz.TXT
Ladder list conversion
CLST6L
Ladder list for
M600, M60
zzzz.TXT
List to ladder conversion
GX Converter CNC controller
Ladder data
for M600, M60
zzzz.W PG
Editing (transfer)
GX Developer
RS232C
(1) Creation
The PLC program created for the old model is output in a list format.
(2) Conversion
Using CLST6L (ladder list converter), the output program is converted into a PLC program for
M600, M60/60S series (list format). Using GX Converter (data conversion software package),
the list format program is converted into the GX Developer data.
(3) Editing/transfer
The resultant program can be handled like a newly created PLC program.
- 30 -
3. PLC PROGRAM DEVELOPMENT
3.10 Using PLC46 Type PLC Programs
Set the conversion format on the following data conversion wizard screen.
Choose [Original Data Type]-[Delimited] and [Data Type]-[List], and click [Next>].
- 31 -
3. PLC PROGRAM DEVELOPMENT
3.10 Using PLC46 Type PLC Programs
Choose to highlight the Instruction column part in the [Data Preview] list and choose [Column
Data Format]-[Instr].
Further, choose to highlight the Argument column part in the [Data Preview] list and choose
[Column Data Format]-[I/O(Device)]. Click [Next>].
- 32 -
3. PLC PROGRAM DEVELOPMENT
3.10 Using PLC46 Type PLC Programs
Set the program name used on GX Developer at [Data name] column and a ladder annotation
at [Title] column, and click [Finish].
(6) Completion
The setting is complete when the following completed dialog appears after the converting dialog.
Click [OK].
- 33 -
4. PLC MESSAGE DEVELOPMENT
4.1 Development Procedure
(1) Making conversion into GX Developer data using a general text editor or spreadsheet tool and
data conversion package.
(When there is a large volume of message data and you want to control them with a
commercially available tool, for example)
RS232C
- 34 -
4. PLC MESSAGE DEVELOPMENT
4.1 Development Procedure
(1) Creation
The message data is described using a general text editor. The description method and format
will be described later.
(2) Conversion
The conversion from text data to GX Developer data is carried out using the "GX Converter
(data conversion software package)".
(3) Transfer
With the GX Developer, the message data is handled as a PLC program interlinear comment,
and can also be edited.
The message data is transferred to the CNC controller using the GX Developer, in the same
manner as the ladder program.
(1) Creation
The message data is described directly from GX Developer. The message data is handled as a
PLC program interlinear comment by GX Developer. The description method and format will be
described later.
(2) Transfer
The message data is transferred from GX Developer to the CNC controller in the same manner
as the ladder program.
- 35 -
4. PLC MESSAGE DEVELOPMENT
4.2 Message Data Description Method
Message data is classified into setting areas to store the setting for each message and message
areas to store message data. It is described in the following respective description format.
The message length and No. of messages are set for each message in the setting area. The
message data region secured by the CNC controller can be adjusted to the most efficient status
using these settings. The respective maximum values are set if nothing is set. (Refer to "4.2.3
Precautions" for the maximum values.)
;$, message classification code, maximum message length, No. of messages [CR]
- 36 -
4. PLC MESSAGE DEVELOPMENT
4.2 Message Data Description Method
The message data is described as text data by the following description format.
(1) Comment
Statements having a semicolon (;) at the head of the line, in a different format than described in
"4.2.1 Description format", are regarded as comments. These comments are handled as
comment data in the GX Developer also, but are erased during the transfer to the CNC
controller. An error will occur if there is no semicolon at the head of the line.
Each message is set here. This area must be described before the message area of the
relevant message. That setting will be ignored if it is described in the middle of or after the
relevant message description.
Collect similar messages in a group and describe them. There is no description order in the
respective messages, but the latter description is validated if there are descriptions with the
same factors (index No., etc.).
A page break code is described at one or more places approx. every 15 lines in the setting area
and message area. The message data may skip if there is no page break code.
- 37 -
4. PLC MESSAGE DEVELOPMENT
4.2 Message Data Description Method
An end code is described at the end of the description. Description after the end code are
ignored.
An error will occur if there is no end code.
4.2.3 Precautions
No. of characters, quantity limitations, handling of information other than settings, handling of
information other than format are described below.
Processing will be carried out with the following values considered as the maximum values if the
setting is not carried out in the setting area, or if the description position in the setting area is
illegal.
[Note] Two-byte data in the message character string is handled as two characters.
GX Developer accepts 64 characters as an interlinear comment. However, since that
includes information other than a message character string (e.g. message classification
code, index No. and data register No.), the message character string is actually up to
58 characters long.
(2) When the setting value and message data do not match
When the message data contents (such as index No., switch No. and message character string)
overflows from the settings in the setting area, the data that overflowed is ignored.
- 38 -
4. PLC MESSAGE DEVELOPMENT
4.3 Converting Data into GX Developer Format
Set the conversion format on the following data conversion wizard screen.
Choose [Original Data Type]-[Fixed Width] and [Data Type]-[List], and click [Next>].
- 39 -
4. PLC MESSAGE DEVELOPMENT
4.3 Converting Data into GX Developer Format
Choose to highlight the Instruction column part in the [Data Preview] list and choose [Column
Data Format]-[Instruction ,Statement ,Note]. Click [Next>].
Set the program name used on GX Developer in [Data name] and a data annotation in [Title],
and click [Finish]. Data conversion is completed when the Completed dialog appears. Click
[OK].
- 40 -
4. PLC MESSAGE DEVELOPMENT
4.4 Entering/Editing Data Using GX Developer
Perform the following operation to display the "Project data list" window and double-click the file
name to display the edit screen. First, the normal ladder screen appears.
[View] → [Project data list], then double-click [File name you want to display].
(2) Display of message data
Perform the following operation to display the message data that are integrated type interlinear
statements.
[View] → [Statement]
- 41 -
4. PLC MESSAGE DEVELOPMENT
4.4 Entering/Editing Data Using GX Developer
Perform the following operation to display the "Project data list" window and double-click the file
name to display the edit screen. First, the normal ladder screen appears.
[View] → [Project data list], then double-click [File name you want to display].
(2) Display of list data
Perform the following operation to display the list data. The list display also shows the message
data that are integrated type interlinear statements.
[View] → [Ladder]
- 42 -
4. PLC MESSAGE DEVELOPMENT
4.4 Entering/Editing Data Using GX Developer
On the circuit display screen that shows the integrated type interlinear statements, double-
clicking the interlinear statement you want to edit displays the following dialog. Perform editing
operation on the dialog and click [OK] or press [Enter].
On the list display screen, double-clicking the interlinear statement you want to edit displays the
following dialog. Perform editing operation on the dialog and click [OK] or press [Enter].
Perform the following operation to display the [New] dialog, and set the [Data name] and
[Title]. After setting, click [OK].
Press "Enter" at the "END" line, and input the data in the same manner as 4.4.3 (2) above.
Then, press "Enter" on the next line, and input the message data.
- 43 -
4. PLC MESSAGE DEVELOPMENT
4.5 Writing to the CNC Controller
- 44 -
4. PLC MESSAGE DEVELOPMENT
4.6 Reading and Verifying from the CNC Controller
The message description format was shown in "4.2.1 Description format", but there are no special
rules concerning provision of descriptions in the setting area or the order of message description in
the message area. For that reason, the description format may differ between transfer and reading
of the message data.
The following shows the format during reading as the "Standard description format".
(6) Others
• Spaces and tabs are not included before and after the comma(,) separating the message data
factors.
• The message character string is handled the same as normal data even when blank.
• The NOPLF code between messages is described to the position to which the message data
following the NOPLF code during transfer moved.
- 45 -
5. DEVICE COMMENT CREATION
5.1 Development Procedure
In this method, device comments are converted into GX Developer data using a general text
editor or spreadsheet tool and data conversion package. Use this method when you want to
divert the device comments of the old model or when a device comment volume is large and
you want to control them with a commercially available tool, for example.
Creation
Spreadsheet tool
Text editor
M600, M60
device
comment
zzzz.TXT Conversion
GX Converter CNC controller
M600, M60
device
comment
zzzz.W CD
Editing
GX Developer
RS232C
M600, M60
ladder
zzzz. W PG
In this method, device comments are entered directly from GX Developer. Use this method
when a device comment volume is small or when addition or correction is to be made, for
example.
There are the following three methods for direct entry from GX Developer. Refer to the
Operating Manual for details.
- 46 -
5. DEVICE COMMENT CREATION
5.2 Description Method for Indirect Entry
Save the above data in the CSV format. The following example shows the above data saved in the
CSV format.
- 47 -
5. DEVICE COMMENT CREATION
5.3 Converting Device Comments
Set the conversion format on the following data conversion wizard screen.
Choose [Original Data Type]-[Delimited] and [Data Type]-[Comment], and click [Next>].
- 48 -
5. DEVICE COMMENT CREATION
5.3 Converting Device Comments
Make sure that the column parts in the [Data Preview] list are in order of [Device Number],
[Label] and [Comment], and click [Next>].
Choose [Data type]-[Common comment] or [Program comment], set the comment file name
used on GX Developer in [Data name] and a comment annotation in [Title], and click [Finish].
- 49 -
5. DEVICE COMMENT CREATION
5.3 Converting Device Comments
(5) Completion
The setting is complete when the following dialog appears. Click [OK].
If an error occurred during conversion, its status and the line where it occurred are displayed.
- 50 -
6. RELATIONSHIPS BETWEEN GX DEVELOPER AND ONBOARD FUNCTIONS
6.1 Function Differences
The restriction specifications related to circuit display/editing differ between GX Developer and
onboard functions. Since the restriction specifications of the onboard functions are narrower
than those of GX Developer, care should be taken when creating a circuit on the GX Developer
side.
Onboard GX Developer
Number of 8 contacts, 1 coil 11 contacts, 1 coil
Display contacts
specifications Number of 9 lines Depending on window
of single screen lines size and screen reduction
ratio
Restriction specifications of 18 lines (return count: 0) 24 lines of 200 or more
single circuit (Note 1) series contacts
(Note 1) The relationships between the return count and the maximum value of the vertical
width of the circuit that can be created at that time are as follows.
Return count (times) 0 1 2 3 4 5 6 7 8
Vertical width of circuit (lines) 18 11 7 5 4 3 3 2 2
Excess over the above will result in "LADDER ERROR".
If the circuit created on the GX Developer side exceeds the circuit restriction specifications
of the onboard functions, the following message is displayed.
Operation Message Handling
When "read" or "monitor" function "DISPLAY OVER FLOW" Circuit is not displayed.
is used to display circuit (Only bus is displayed)
When "write", "insertion", "NOT WRITE" Editing operation is
"deletion" or "conversion" function inhibited.
is selected
- 51 -
6. RELATIONSHIPS BETWEEN GX DEVELOPER AND ONBOARD FUNCTIONS
6.2 Specification Differences
The step count specifications in the individual instructions of the MELSEC and MELDAS differ
in some instructions. Therefore, steps may be different when the same circuit is displayed by
GX Developer and onboard functions.
This will give rise to a problem especially when the circuit diagram printed from GX Developer
is used for maintenance with the onboard functions. To resolve this problem, a tool (PCNV6LM)
to print a circuit diagram in the MELDAS step specifications is available.
MELDAS original specification instructions that cannot be handled with GX Developer are used
after being replaced with alternate instructions which can be handled by GX Developer. The
specifications when these instructions are displayed with the onboard are shown below.
D
Bit DEFR ⎯[ DEFR D ]⎯
⎯ ↑ ⎯
Average value AVE ⎯[ AVE S D n ] ⎯[ S.AVE S D n ]
Carry flag set STC ⎯[ STC ] ⎯[ S.STC ]
Carry flag reset CLC ⎯[ CLC ] ⎯[ S.CLC ]
ATC ATC ⎯[ ATC Kn Rn Rm Mm ] ⎯[ S.ATC Kn Rn Rm Mm ]
ROT ROT ⎯[ ROT Kn Rn Rm Mm ] ⎯[ S.ROT Kn Rn Rm Mm ]
TSRH TSRH ⎯[ TSRH Rm Rn Mn ] ⎯[ S.TSRH Rm Rn Mn ]
DDBA DDBA ⎯[ DDBA Rn/Dn ] ⎯[ S. DDBA Rn/Dn]
DDBS DDBS ⎯[ DDBS Rn ] ⎯[ S. DDBS Rn ]
CAL1 CAL1 ⎯[ CAL1 Pn ] ⎯[ S. CAL1 Pn ]
LDBIT [ < = S1 n ]⎯ [ < = S1 n ]⎯
ANDBIT ⎯[ < = S1 n ]⎯ ⎯[ < = S1 n ]⎯
ORBIT [ < = S1 n ] [ < = S1 n ]
BIT
LDBII [< > S1 n ]⎯ [ < > S1 n ]⎯
ANDBII ⎯[ < > S1 n ]⎯ ⎯[ < > S1 n ]⎯
ORBII [ < > S1 n ] [ < > S1 n ]
The circuit of the END instruction is not displayed by the onboard functions.
- 52 -
7. PROCEDURE FOR WRITING PLC PROGRAMS, ETC. TO ROM
7.1 Data That Can Be Written to ROM
Related data
Remarks
classification
1 PLC program (ladder) PLC program code
2 PLC program comment Comment data for GPPQ/W
3 Message 1st language 1st language data of message data such as alarm
messages, operator messages, and PLC switches
4 Message 2nd language Same as above
(2nd language data)
- 53 -
7. PROCEDURE FOR ROMING PLC PROGRAMS, ETC.
7.2 ROM Writing Operation Procedure
The following gives the common operations and individual operations of the M600M and M600L
operation procedures. For details of the I/O screen, refer to the instruction manual of that model.
Set the [Device], [Directory] and [File] of [A:Device] and [B:Device] respectively. Selecting any
of the following functions on the menu keys starts the corresponding operation.
(a) [Trnsfr A->B]
Data is transferred from Device A to Device B. If Device B is an F-ROM, the F-ROM
contents is erased and the data of Device A is written to it. Devices A, B may be other than
the internal RAM or F-ROM (storage such as the hard disk).
(b) [Compare A:B]
Data of Device A and Device B are compared. Devices A, B may be other than the internal
RAM or F-ROM.
(c) [Erase A]
The data of Device A is erased. Note that it is not erased when the internal RAM is
specified.
(d) [Erase B]
The data of Device B is erased. Note that it is not erased when the internal RAM is
specified.
(2) Individual operations (How to set the [Device], [Directory] and [File])
(a) M600M
(i) Device selection
Specify [Memory] from the menu key.
(ii) Directory designation
Type the storage region type in the setting box.
Internal RAM : "/MEM"
Internal F-ROM : "/FRA"
External cassette F-ROM: "/FRB"
(iii) File name designation
Type the file name in the setting box.
Fixed to "LAD.DAT"
(b) M600L
(i) Device selection
Specify [Memory] from the menu key.
(ii) Directory designation
Specify [PLC prog] from the menu key.
(iii) File name designation
Specify the storage region type from the menu key.
[Inside RAM], [Inside F-ROM] or [Outside F-ROM]
- 54 -
8. LIST OF ERROR STATES
[Note] When an error occurred at GX Developer On-line function, the error message may not
explain exactly the state in the CNC controller side.
Always refer to the error list.
The following table indicates the causes and remedies of the errors that can occur during online
operation with the CNC controller. For other errors, refer to the GX Developer Operating Manual.
- 55 -
8. LIST OF ERROR STATES
- 56 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
Appendix 1.1 GPPQ Function Outline and Functions Supported by the M600,
M60/60S Series
The GPPQ functions explained here are those supported by the M600, M60/60S Series in the "off-
line functions" operated with the GPPQ independently and "on-line functions" carried out connected
to the CNC controller.
Refer to the enclosed Operating Manual (off-line section and on-line section) for function details.
The following shows a list of GPPQ outline functions supported by the M600, M60/60S Series.
A mark indicates functions that can be used by the M600, M60/60S Series. An r mark indicates
that the function cannot be used because it is related to "MELSEC Series" characteristic functions.
The function details during on-line are described in the next section.
List of general section functions (1) : Possible, r : Support not possible/not determined
Mode Function Support Remarks
Initialization New creation
File new read
PLC new read → Refer to the List of on-line section functions
File quit
PLC type change r Q4ACPU only
Option Environment setting
Display and operation option
Startup setting
Circuit Write → Refer to the List of on-line section functions
Read → Refer to the List of on-line section functions
Monitor → Refer to the List of on-line section functions
Test → Refer to the List of on-line section functions
Debug → Refer to the List of on-line section functions
File access → Refer to the List of on-line section functions
PLC access → Refer to the List of on-line section functions
Program search → Refer to the List of on-line section functions
Comment display → Refer to the List of on-line section functions
Program edit → Refer to the List of on-line section functions
Monitor and test → Refer to the List of on-line section functions
Window changeover → Refer to the List of on-line section functions
Option → Refer to the List of on-line section functions
List Write
Read
File access
PLC access → Refer to the List of on-line section functions
Program search
Comment display
Program edit
Window changeover
Option
- 57 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
List of general section functions (2) : Possible, r : Support not possible/not determined
Mode Function Support Remarks
Parameter PLC name setting r
PLC system setting r
PLC file setting r
Device setting r
PLC RAS setting r
I/O assignment r
MELSECNET (II,10)/Ethernet setting r
MELSECNET/MINI setting r
MELSECNET/J setting r
Miscellaneous setting r
Duplex PLC setting r
SFC r
X/Y assignment confirmation r
File access r
PLC access r
Parameter search r
Parameter edit r
Miscellaneous setting r
Window changeover r
Option r
Device Device value input → Refer to the List of on-line section functions
Device initialization → Refer to the List of on-line section functions
Buffer memory simulation → Refer to the List of on-line section functions
File access
PLC access → Refer to the List of on-line section functions
Device search
Device display
Device edit → Refer to the List of on-line section functions
Window changeover
Option
On-line Drive name selection → Refer to the List of on-line section functions
File name selection → Refer to the List of on-line section functions
File access → Refer to the List of on-line section functions
PLC access → Refer to the List of on-line section functions
Data search → Refer to the List of on-line section functions
Trace → Refer to the List of on-line section functions
Trace device edit → Refer to the List of on-line section functions
Device test → Refer to the List of on-line section functions
Window changeover → Refer to the List of on-line section functions
PLC Diagnosis target selection r
diagnosis Current error display r
Fault history display r
CPU message r
Unit detailed display r
File access r
PLC access → Refer to the List of on-line section functions
Data search r
Error display r
Network monitor and test r
Window changeover r
Option r
- 58 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
List of general section functions (3) : Possible, r : Support not possible/not determined
Mode Function Support Remarks
Text Device comment
creation Pointer statement
Interlinear statement
Note
Print statement
File access
PLC access → Refer to the List of on-line section functions
Comment search
Comment edit
Window changeover
Option
Printer Printer data setting
Print execution
Printer setting
Paper size change
Edit
Window changeover
Option
File Machine name/File name selection
maintenance File access
PLC access → Refer to the List of on-line section functions
File search
Display
IC memory card r
Window changeover
Option
Program Label name definition
generation File access
Program generation
Label display
Display
Label edit
Window changeover
Option
SFC r
Quit
- 59 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
The following shows a list of GPPQ on-line functions supported by the M600, M60/60S Series.
A mark indicates functions that can currently be used by the M600, M60/60S Series. An r mark
indicates that the function cannot be used because it is related to "MELSEC Series" characteristic
functions.
List of on-line section functions (1) : Possible, r : Support not possible/not determined
Mode Function Menu Detailed function Support Remarks
6.2 Circuit write 6.2.1 Write during run r
6.3 Circuit read 6.3.1 Step No. read
6.3.2 Instruction read
6.3.3 Device read
6.3.4 Contact and coil designation
read
6.3.5 Statement and note
designation read
6.3.6 Last circuit designation read
6.4 Monitor 6.4.1 Monitor screen common
display Monitor destination CPU name
No. of Monitor program steps
Monitor program name
Scan time r
Monitor interval
CPU operation status
Monitor destination
Flicker during communication
6.4.2 Circuit monitor
Bit device monitor display
Word device monitor display
Digit designation monitor display
Timer/counter monitor display
Double word monitor display
Index modification monitor display
Circuit
mode Monitor step changeover
Changeover to next circuit block
Changeover to previous circuit block
Monitor stop
Monitor column numeric value/No. of
display levels changeover
6.4.3 Device registration monitor
Bit device monitor display
Word device monitor display
Digit designation monitor display
Timer/counter monitor display
Double word monitor display
Index modification monitor display
16-bit integer designation
32-bit integer designation
Real number designation r
Character designation r
Registration device erase
6.4.4 ON/OFF cause automatic
search
6.5 Test 6.5.1 Monitor trigger stop
Stop at bit device rising edge r
Stop at bit device falling edge r
Stop at word device designation
value r
Monitor restart r
- 60 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
List of on-line section functions (2) : Possible, r : Support not possible/not determined
Mode Function Menu Detailed function Support Remarks
6.5 Test 6.5.2 Forced ON/OFF
Forced ON r
Forced OFF r
6.5.3 Current value change
16-bit change r
32-bit change r
6.5.4 Setting value change
Timer r
Counter r
6.6 Debug 6.6.1 Step execution r
6.6.2 Partial execution r
6.7 File menu 6.7.1 Read
6.7.2 Write
6.7.3 Compare
6.8 PLC menu 6.8.1 Read
6.8.2 Write
Parameter r
Sequence program
Entire range
Range designation r
Device comment
Device default value r
Simulation data r
File register r
Device memory r
Entire range r
Range designation r
6.8.3 Compare
Circuit
mode 6.8.4 New edit target read r
6.8.5 List of files
File name
Classification
Size
Date
Time
Header statement
No. of files
Continuous max. open capacity
Entire open capacity
6.8.6 Connection designation
Peripheral side interface
PLC side interface r Fixed
Target CPU r Fixed
Target memory r Fixed
6.8.7 Remote operation CPU status display
RUN
STOP
PAUSE r
STEP-RUN r
Latch clear r
Reset r
Operation during RUN, STEP-RUN r
Execution destination designation r
Execution unit designation r
6.8.8 Write option For write
r during run
- 61 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
List of on-line section functions (3) : Possible, r : Support not possible/not determined
Mode Function Menu Detailed function Support Remarks
6.9 Display 6.9.1 Circuit display changeover
menu Device name display
Comment display
Statement display
Display with note
6.10 Monitor 6.10.1 Device batch monitor
and test Bit device monitor display
menu Word device monitor display
Bit and word monitor
Bit multipoint monitor
Word multipoint monitor
Timer/counter mulipoint monitor
Target device change
Decimal/hexadecimal display
changeover
Integer/real number display
changeover
0 → F/F → 0 display changeover
Forced ON
Forced OFF
6.10.2 Multiple device batch monitor
Bit device monitor display
Word device monitor display
Decimal/hexadecimal display
changeover
Integer/real number display
changeover
Registration device erase
Forced ON
Forced OFF
Circuit
6.10.3 ON/OFF cause automatic
mode
search
6.10.4 Scan time measure r
6.10.5 Device registration monitor Bit device monitor display
Word device monitor display
Digit designation monitor display
Timer/counter monitor display
Double word monitor display
Index modification monitor display
16-bit integer designation
32-bit integer designation
Real number designation
Character designation
Registration device erase
6.10.6 Monitor and test menu
Constant monitoring r
Word device condition
Bit device condition
Step No. r
6.10.7 Monitor stop condition setting
Monitoring does not stop
Word device condition
Bit device condition
Operation status r
6.10.8 Monitor data
registration/application
6.10.9 Device test
Forced ON
Forced OFF
Forced ON/OFF reverse
Current value change
- 62 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.1 GPPQ Function Outline and Functions Supported by the M600, M60/60S Series
List of on-line section functions (4) : Possible, r : Support not possible/not determined
Mode Function Menu Detailed function Support Remarks
6.10 Monitor 6.10.10 Sampling/monitoring trace U
and test 6.10.11 Step execution U
menu 6.10.12 Partial execution U
6.10.13 Skip execution U
6.10.14 Simulation U
Circuit 6.10.15 Monitor column numeric
mode value display changeover Numeric value display format
No. of display level
6.10.16 Program execution status U
monitor
6.11 Option 6.11.1 Monitor destination setting U
menu
8.2 PLC menu
Para-
meter Refer to 6.8
mode →
PLC menu
9.2 Device U
value input
9.3 Default
value U
range
setting
Device
mode 9.4 Buffer
memory U
simulation
List of on-line section functions (5) : Possible, r : Support not possible/not determined
Mode Function Menu Detailed function Support Remarks
10.5 PLC 10.5.7 Remote operation CPU status display
menu RUN
STOP
PAUSE U
STEP-RUN U
Latch clear U
Reset U
Operation during RUN, STEP-RUN U
Execution destination designation U
Execution unit designation U
10.5.8 Write option U For write
during run
10.5.9 Key word registration U
10.5.10 Device memory operation U
10.5.11 PLC memory batch U
operation
On- 10.5.12 Delete
line 10.5.13 Header statement creation U
mode
10.6 Search 10.6.1 Head/end search U
menu 10.6.2 File search U
10.6.3 Frequency search U
10.6.4 Time search U
10.6.5 Data search U
10.7 Trace 10.7.1 Sampling trace U
menu 10.7.2 Monitoring trance U
10.7.3 Status latch U
10.7.4 Program trace U
10.8 Edit menu 10.8.1 Cut/copy/paste U
10.9 Test menu 10.9.1 Device test U
Forced ON
Forced OFF
Forced ON/OFF reverse
Current value change
10.10 Window 10.10.1 Display window change
menu
11.2 Diagnosis
target U
selection
11.3 Current
error U
display
11.4 Fault
history U
display
11.5 CPU U
message
11.6 Unit
PLC detailed U
diagno- display
sis 11.7 File menu U
mode
11.8 PLC U
menu
11.9 Search U
menu
11.10 Display U
menu
11.11 Network U
menu
11.12 Window U
menu
11.13 Option U
menu
- 64 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.2 Ladder Transfer to the CNC Controller
The screen is selected from the menu using the following GPPQ basic operation.
The required options are selected and executed on the following screen.
[Write to PLC]
Interface RS232C <---> QnACPU
Target PLC Network : 0 Station : FF PLC Type : Q4A
Target Mem Internal RAM Title [ ]
1. File 1. File Name [ ] Title [ ]
2. Tgt 1. [ * ] Parameter
2. [ * ] Seq/SFC Prog 1. ( * ) Whole Range
2. ( ) Step Range [ ]–[ ]
3. [ ] Device Comment 3. ( ) Step Range P[ ] – [ ]
4. [ ] Dev Init Value 4. ( ) Block Range [ ]–[ ]
5. [ ] Simulation Data
6. [ ] File Register 1. ( * ) Whole Range
2. ( ) Specify ZR[ ]–[ ]
2. Device Mem 1. [ ] Internal 1. ( * ) Whole Range
2. ( ) Specify Detail Range
Execute(Y) Cancel(N)
[Restrictions]
The following options of [2. Tgt] under [1. File] can be selected.
[1. Parameter]
[2. Seq/SFC Prog] and [1. Whole Range]
[3. Device Comment]
Note that nothing will be transferred even if [1. Parameter] is selected.
- 65 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.2 Ladder Transfer to the CNC Controller
The ladder data is converted to the ladder machine code characteristic to the CNC controller
simultaneously with the ladder transfer from the GPPQ to the CNC controller. A conversion error will
occur if devices or instruction formats are used that are not supported by the M600, M60/60S Series.
During a conversion error, the following message appears at the bottom of the GPPQ screen after
the M600 ladder machine code is converted to an "NOP code" and transferred to the last step.
The following warning statement appears in the header statement item when the file having the
conversion error is displayed with the PLC file list function.
[List]
:
File Type Size Data Time Title
PLCTEST QnA Seq 12345 97-11-18 10:34 [∗∗WARNING: Checksum ERROR!!∗∗]
:
If an attempt is made to run the PLC in this status, the following alarm message will appear on the
NC side, and the PLC will not run.
The error step can be confirmed using the PLC compare function. The mismatched contents appear
as in the following example when the PLC comparison is executed. Refer to "Appendix 1.4 Ladder
comparison with the CNC controller" for details.
[Sequence Program Diff List]
- 66 -
APPENDIX 1. OPERATION METHODS USING GPPQ
APPENDIX 1.3 Ladder Read from the CNC Controller
The screen is selected from the menu using the following GPPQ basic operation.
The file names are designated and executed on the following screen.
File name designation method
Input the file name stored in the read target memory.
Display the read target memory list screen by pressing Ctrl + D .
Display the file list screen by pressing Ctrl + L .
After selecting the file using ↑ and ↓ , display the file name selected in the file name
designation column by pressing Enter .
Execute(Y) Cancel(N)
[Restrictions]
The following options of [2. Tgt] under [1. File] can be selected.
[2. Seq/SFC Prog] and [1. Whole Range]
[3. Device Comment]
- 67 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.4 Ladder Comparison with CNC Controller
The screen is selected from the menu using the following GPPQ basic operation.
The file names are designated and executed on the following screen. The options that can be
selected are the same as those of the ladder read.
File name designation method
Input the file name stored in the read target memory.
Display the read target memory list screen by pressing Ctrl + D .
Display the file list screen by pressing Ctrl + L .
After selecting the file using ↑ and ↓ , display the file name selected in the file name
designation column by pressing Enter .
[PLC compare]
Interface RS232C <---> QnACPU
Target PLC Network : 0 Station : FF PC Type : Q4A
Target Mem Internal RAM Title [ ]
1. File 1. File Name [ ] Title [ ]
2. Tgt 1. [ * ] Parameter
:
:
:
Execute(Y) Cancel(N)
When the comparison contents do not match, a screen with the mismatched contents appears.
- 68 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.5 PLC-Related Data Development Procedure
Use the "CNVQ (data conversion software package)" for conversion from text data to GPPQ data.
Instead of text data, spreadsheet software data can also be converted to GPPQ data. Refer to the
Operating Manual for details.
(1) Initialization
After CNVQ is started, the project file (file for setting the drive/path name, system name,
machine name, file name, etc.) is read or newly created.
Refer to the Operating Manual for the operation method.
The screen is selected from the menu using the following CNVQ basic operation.
Mode Conversion
F11 ( HOME CLR ) selection 3 format set- Alt ( GRPH ) 2
Mode menu screen Conversion ting screen
Menu Conversion
format setting format change
The conversion format is set on the following screen. Select the "Statement" item shown by the
arrow (1) when converting message data.
Refer to the CNVQ Operating Manual for details.
1. Delimter
1. ( * ) Tab 1. ( * ) Auto Adjust (1Tab [ 8]Column)
2. ( ) Left Align
3. ( ) Specify [ 1]Tab
2. ( * ) Space 1. ( * ) Auto Adjust
2. ( ) Left Align
3. ( ) Specify [ 1]Column
2. Input Conditions
1. ( ) Step #
2. ( ) Device Comment
3. ( * ) Statement (1)
4. ( ) Note
5. ( ) Device Label
6. ( ) Without NOP
Execute(Y) Cancel(N)
- 69 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.5 PLC-Related Data Development Procedure
The screen is selected from the menu using the following CNVQ basic operation.
Mode Commercially
F11 ( HOME CLR ) selection 1 available software
menu screen -> QnA conversion
Mode Com mercially setting screen
available software
-> QnA conversion
The conversion source/destination directory path and conversion file name, etc., are set on the
following screen. Refer to the Operating Manual for details.
PgUp : Prev Page PgDn : Next Page Ctrl+P :Drive/Path Enter : Decide
The screen is selected from the menu using the following CNVQ basic operation.
The conversion status appears at the bottom of the screen. If "There were n conversion errors"
appears when the conversion is finished, display the conversion error edit screen from the menu
using the following CNVQ basic operation to confirm the error contents.
- 70 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.5 PLC-Related Data Development Procedure
Message data in the GPPQ is handled as "Integrated type interlinear statements" in the PLC
program. "Integrated type interlinear statements" are interlinear comments to help in understanding
the PLC program. Interlinear comments transferred with the PLC program to the controller are
called "integrated type".
"Interlinear statements" can be displayed in the "Circuit mode", and edited on the "Interlinear
statement edit screen".
The screen is selected from the menu using the following GPPQ basic operation.
Display Interlinear
Circuit mode Alt ( GRPH ) 4 menu 3 statement
screen display
Menu Display window Interlinear screen
statement
The following appears. At that time, the page break code and end code appear as normal
ladder codes.
$, A, 32, 200
$, 0, 40, 200
$, P, 12, 32
$, M, 60, 20
12 NOPLF
A, 0, 0, EMERGENCY STOP
A, 11, 1, SPINDLE ALARM
:
:
:
:
98 NOPLF
:
:
:
:
- 71 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.5 PLC-Related Data Development Procedure
The screen is selected from the menu using the following GPPQ basic operation.
Mode Device
F11 ( HOME CLR ) selection 7 comment Alt ( GRPH ) 5
Mode menu screen Text creation edit screen Menu Edit
Edit menu
screen 6 Step No. Interlinear
Interlinear designation [ Step ] Enter Y statement
statement
screen Execution edit screen
Ctrl + F7
Statement
The message data can be edited on the following screen. The GPPQ data can be converted to
text data using the CNVQ to save the edited data as text data. Refer to the CNVQ Operating
Manual for details.
- 72 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.5 PLC-Related Data Development Procedure
The following shows the method of transferring a message from the GPPQ to the CNC controller.
The transfer method is the same as that of the ladder code. Ladder codes and message data are
distinguished by their file names only.
The screen is selected from the menu using the following basic operation.
[Write to PLC]
Interface RS232C <---> QnACPU
Target PLC Network : 0 Station : FF PC Type : Q4A
Target Mem Internal RAM Title [ ]
1. File 1. File Name [ M1TEST ] Title [ message 1st language test ]
2. Tgt 1. [ ] Parameter
2. [ * ] Seq/SFC Prog 1. ( * ) Whole Range
2. ( ) Step Range [ ]–[ ]
3. [ ] Device Comment 3. ( ) Step Range P[ ] – [ ]
4. [ ] Dev Init Value 4. ( ) Block Range [ ]–[ ]
5. [ ] Simulation Data
6. [ ] File Register 1. ( * ) Whole Range
2. ( ) Specify ZR[ ]–[ ]
2. Device Mem 1. [ ] Internal 1. ( * ) Whole Range
2. ( ) Specify Detail Range
Execute(Y) Cancel(N)
The following describes the method of reading and comparing a message from the CNC controller
to the GPPQ. The method of reading and comparing is the same as that of ladder codes. Ladder
codes and message data are distinguished by their file names only.
- 73 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.5 PLC-Related Data Development Procedure
The message description format was shown in "5.3.1 Description format", but there are no
special rules concerning provision of descriptions in the setting area or the order of message
description in the message area. For that reason, the description format may differ between
transfer and reading of the message data.
The following shows the format during reading as the "Standard description format".
(f) Others
• Spaces and tabs are not included before and after the comma(,) separating the message
data factors.
• The message character string is handled the same as normal data even when blank.
• The NOPLF code between messages is described to the position to which the message
data following the NOPLF code during transfer moved.
Message data comparison can be executed in the same manner as the ladder program,
however, note that the target compared is the ladder code (NOPLF, END) only. Therefore,
message data described as "Integrated type interlinear statements" are not compared.
When comparing, read the data to the GPPQ side using the read function, then compare using
the master file and file comparison function.
- 74 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.6 Procedure for ROM Writing
ROM cassette insertion ... Insert the ROM cassette in the CBUS1 slot.
... Contents are read if PLC data already exists on the ROM cassette.
Power turned ON
PLC data region formatted ... The PLC data region is formatted with the GPPQ.
Already existing PLC data is erased.
PLC (Ladder programs are not erased.)
stop
PLC data transfer ... The required PLC data is transferred from the GPPQ.
Operation confirmation ... The operation of the transferred PLC data is confirmed.
ROM write ... ROM writing is carried out with the GPPQ.
NC restart ... The PLC data is read from the ROM cassette.
Operation reconfirmation ... The operation of the PLC data is confirmed again.
- 75 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.6 Procedure for ROM Writing
It is recommended to initialize the data region before ROM writing. (This is not absolutely
required, however.)
The difference from file deletion is that the file control region is initialized.
The screen is selected from the menu using the following basic operation.
Mode On-line
F11 ( HOME CLR ) selection 5 mode Alt ( GRPH ) 2
Mode menu screen On-line screen Menu PC
PLC memory
PLC menu batch 2
B
window operation
PLC memory window PLC memory
batch operation format
The PLC related data (excluding ladder programs) is completely erased by the above operation.
Mode On-line
F11 ( HOME CLR ) selection 5 mode
Mode menu screen On-line screen
The following drive name selection screen or file name selection screen appears. If the file
name selection screen appears, it can be returned to the drive name selection screen with the
Escape [esc] key.
- 76 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.6 Procedure for ROM Writing
The drive mounted on the CNC controller can be selected, and the following operations carried
out, on the drive name selection screen.
• Copying between drives (Including flash ROM writing)
• Displaying the drive details (date of creation, size)
• Confirmation of the drive open capacity, etc.
The mounting and PLC data availability is checked for each drive. The header statement
appears when PLC data exists. There are sections in which the drive target memory and the
actual CNC controller drive meaning differ, so confirm with the header statement.
The following shows the meanings in the CNC controller of each drive.
• Drive 0
This refers to the file groups stored in the internal S-RAM (ladder programs) and internal D-
RAM (other than ladder programs).
File transfer with GPPQ is carried out in this drive 0.
Only internal S-RAM information is displayed for the drive capacity.
• Drive 1
This refers to the file groups stored in the internal D-RAM (other than ladder programs).
Only internal D-RAM information is displayed for the drive capacity.
• Drive 2
This refers to the file groups stored in the internal F-ROM. The ladder related data storage
availability to the internal F-ROM differs depending on the system.
Approx. 30 seconds are required until the finish of the writing (copying to drive 2) process to the
internal F-ROM.
• Drive 4
This refers to the file group stored in the cassette F-ROM inserted in the expansion bus. The
expansion bus insertion position is automatically judged.
Approx. 10 seconds are required until the finish of the writing (copying to drive 4) process to the
cassette F-ROM.
- 77 -
APPENDIX 1. OPERATION METHODS USING GPPQ
Appendix 1.6 Procedure for ROM Writing
↑ , ↓ F8 ↑ , ↓ Enter
File selection Copy source Copy destination Copy
selection selection
Select the copy source target memory using ↑ and ↓ , and press F8 .
Set the band cursor to the copy destination target memory drive. The following dialog box appears
when Enter is pressed.
Press Y to execute.
The copy process between drives is executed in the background. The write process starting
message is displayed immediately after execution, and the next operation is not accepted during the
copy process. The copy process time differs depending on the copy target.
A message will appear at the first operation after the copy process is finished if an error occurred in
the copy process. No message will appear if the copy process finished normally.
The following shows the meanings of the messages during and after execution.
Cannot communicate with PLC. The drive background writing process has
Error No. = 4068 started.
Cannot write correctly to the ROM The flash ROM writing was unsuccessful.
- 78 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.1 Development Tools, etc.
- 79 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.2 Devices and Device Assignments
D D0 to D1023 ←
R R0 to R8191 ← Assignment changed.
A0, A1 Discontinued
A ⎯⎯⎯
(replaced by D and R registers).
Z Z Z0
V V Z1 Discontinued (replaced by Z1).
N N0 to N17 ←
P P0 to P255 ←
K-32768 to K32767
K K-2147483648 to ←
K2147483647
H0 to HFFFF
H ←
H0 to HFFFFFFFF
- 80 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.2 Devices and Device Assignments
- 81 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.2 Devices and Device Assignments
- 82 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.2 Devices and Device Assignments
- 83 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.3 PLC Instructions
The instruction range that can be used in the MELSEC-QnA Series PLC program differs from the
instruction range that can be used by the MELDAS Series. Because of this, some instructions that
can be used by the M600, M60/60S cannot be handled with the GX Developer. There are also
instructions that can be used by the GX Developer but cannot be used by the M600, M60/60S.
When these are arranged, they are classified into the three following types.
• M600, M60/60S instructions that cannot be handled with the GX Developer
• M600, M60/60S instructions that the format differs from that of the GX Developer
• Instructions that can be used by the GX Developer, but cannot be used by the M600,
M60/60S
Instructions that cannot be handled with the GX Developer are substituted with alternate instructions
that can be handled with the GX Developer. Instructions that can be alternated are shown in "Table
2.3.1 Table of alternate instruction correspondence".
When some instructions described in "Table 2.3.1 Table of alternate instruction correspondence"
are created with the GX Developer with the M600, M60/60S instruction sign left as is, an error
results and creation cannot be carried out. Create the instructions using the GX Developer
instruction sign described in the correspondence table.
When PLC programs containing alternate instructions are written from the GX Developer to the
M600, M60/60S, they are rewritten to the original MELDAS Series instructions.
- 84 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.3 PLC Instructions
Appendix 2.3.2 Instructions with the format that differs from that of the GX Developer
The device types and assignments have been reconsidered as "Appendix 2.2 Devices and Device
Assignments".
The format of conventional "instructions used by inputting or outputting an accumulator (A0, A1)" is
changed so that the general word register can be designated with arguments without fixing by A0 or
A1 input or output because of the discontinuance of accumulator (A0, A1).
Format-changed instructions are shown in "Table 2.3.2 Table of format-changed instruction
correspondence".
When some instructions described in "Table 2.3.2 Table of format-changed instruction
correspondence" are created with the GX Developer with the conventional instruction sign left as is,
an error results and creation cannot be carried out. Create the instructions using the GX Developer
instruction sign described in the correspondence table.
- 85 -
APPENDIX 2. DIFFERENCES IN DEVELOPMENT ENVIRONMENT BETWEEN PLC4B
AND M600, M60/60S
Appendix 2.3 PLC Instructions
Appendix 2.3.3 Instructions that can be used with the GX Developer, but cannot be used
by the M600, M60/60S
When instructions that cannot be used by the M600, M60/60S are written from the GX Developer to
the M600, M60/60S, they are rewritten to "NOP" instructions, and if they are run, an alarm will occur.
(Note that instructions described in "Table 2.3.1 Table of alternate instruction correspondence" are
rewritten to the corresponding M600, M60/60S instructions.)
"Instructions that can be used by the GX Developer, but cannot be used in the M600, M60/60S " are
defined by the following expression.
"Instructions that can be used by the GX Developer, but cannot be used in the M600, M60/60S"
= "All instructions described in the QnA Programming Instruction Manual"
- ("All instructions described in the M600, M60/60S PLC Programming Instruction
Manual"
+ "Table 2.3.1 Table of alternate instruction correspondence"
+ "Table 2.3.2 Table of format-changed instruction correspondence")
- 86 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.1 Sequence Instructions
LDI
ORB ORB
AND
MPS MPS
ANI MRD MRD
OR MPP MPP
INV
ORI
LDP MEP
MEF
LDF
Vn
EGP
ANDP
Vn
EGF
ANDF
ORP
ORF
RST RST D
Master control instructions
PLS PLS D
Classifi- Instruction
Symbol
PLF PLF D cation sign
Master
MC n D
FF FF D control MC
MCR MCR n
DELTA DELTA D
DELTAP DELTAP D
- 87 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.2 Comparison Operation Instructions
PAGE PAGE n
LD S1 S2 LDD D S1 S2
AND S1 S2 ANDD D S1 S2
OR S1 S2 ORD D S1 S2
LD S1 S2 LDD D S1 S2
AND S1 S2 ANDD D S1 S2
OR S1 S2 ORD D S1 S2
LD S1 S2 LDD D S1 S2
AND S1 S2 ANDD D S1 S2
OR ORD D S1 S2
S1 S2
LD S1 S2 LDD D S1 S2
AND S1 S2 ANDD D S1 S2
OR ORD D S1 S2
S1 S2
LD S1 S2 LDD D S1 S2
AND S1 S2 ANDD D S1 S2
OR S1 S2
ORD D S1 S2
- 88 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.2 Comparison Operation Instructions
LDE E S1 S2 LD$ $ S1 S2
ANDE E S1 S2 AND$ $ S1 S2
ORE E S1 S2 OR$ $ S1 S2
LDE E S1 S2 LD$ $ S1 S2
ANDE E S1 S2 AND$ $ S1 S2
ORE E S1 S2 OR$ $ S1 S2
LDE E S1 S2 LD$ $ S1 S2
ANDE E S1 S2 AND$ $ S1 S2
ORE E S1 S2 OR$ $ S1 S2
LDE E S1 S2 LD$ $ S1 S2
ANDE E S1 S2 AND$ $ S1 S2
ORE E S1 S2 OR$ $ S1 S2
LDE E S1 S2 LD$ $ S1 S2
ANDE E S1 S2 AND$ $ S1 S2
ORE E S1 S2 OR$ $ S1 S2
Block BKCMP S1 S2 D n
BKCMP
data
compar- BKCMP BKCMP S1 S2 D n
ison
BKCMP BKCMP S1 S2 D n
BKCMP BKCMP S1 S2 D n
BKCMP BKCMP S1 S2 D n
BKCMP BKCMP S1 S2 D n
BKCMP P BKCMP P S1 S2 D n
BKCMP P BKCMP P S1 S2 D n
BKCMP P BKCMP P S1 S2 D n
BKCMP P BKCMP P S1 S2 D n
BKCMP P BKCMP P S1 S2 D n
BKCMP P BKCMP P S1 S2 D n
- 89 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.2 Comparison Operation Instructions
+P +P S1 S2 D B+P B+P S1 S2 D
S D B B S D
P P S D B P B P S D
S1 S2 D B B S1 S2 D
P P S1 S2 D B P B P S1 S2 D
BIN D+ S D BCD DB+ S D
D+ DB+
32-bit 8-digit
addition/ D+P D+P S D addition/ DB+P DB+P S D
subtrac- subtracti
tion D+ D+ S1 S2 D on DB+ DB+ S1 S2 D
D D S D DB DB S D
D P D P S D DB P DB P S D
D D S1 S2 D DB DB S1 S2 D
D P D P S1 S2 D DB P DB P S1 S2 D
BIN S1 S2 D BCD B S1 S2 D
B
16-bit 4-digit
multipli- P P S1 S2 D multipli B P B P S1 S2 D
cation/ cation/
division / / S1 S2 D division B/ B/ S1 S2 D
/P /P S1 S2 D B/P B/P S1 S2 D
BIN D S1 S2 D BCD DB S1 S2 D
D DB
32-bit 8-digit
multipli- D P D P S1 S2 D multipli DB P DB P S1 S2 D
cation/ cation/
division D/ D/ S1 S2 D division DB/ DB/ S1 S2 D
- 90 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.2 Comparison Operation Instructions
E P E P S1 S2 D DFLTP DFLTP S D
E S1 S2 D Floating- INT S D
Floating- E INT
point ->
point
E P E P S1 S2 D BIN INTP INTP S D
data
conver-
multiplic-
E/ E/ S1 S2 D sion DINT DINT S D
ation/
division E/P E/P S1 S2 D DINTP DINTP S D
BK P BK P S1 S2 D n WORDP WORDP S D
- 91 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.2 Comparison Operation Instructions
Floating- EMOV S D
EMOV Program execution control instructions
point
data EMOVP S D Classifi- Instruction
transfer EMOVP Symbol
cation sign
Charac- $MOV S D Interrupt
$MOV DI DI
ter string disable
data $MOVP S D
$MOVP Interrupt
transfer EI EI
enable
16-bit CML CML S D Interrupt
data NOT disable/
transfer CMLP CMLP S D IMASK IMASK S
enable
32-bit setting
DCML DCML S D
data NOT Return IRET IRET
transfer DCMLP DCMLP S D
- 92 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.3 Application Instructions
DRCRP DRCRP D n
DXOR DXOR S D
Left DROL D n
DROL
DXORP DXORP S D rotation
DROLP DROLP D n
DXOR S1 S2 D
DXOR
DRCL DRCL D n
DXORP S1 S2 D
DXORP DRCLP D n
DRCLP
BKXOR S1 S2 D n
BKXOR
BKXORP S1 S2 D n
BKXORP
- 93 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.3 Application Instructions
- 94 -
APPENDIX 3. LIST OF INSTRUCTIONS USABLE WITH GX DEVELOPER
Appendix 3.3 Application Instructions
FIFR FIFR S D
FIFRP FIFRP S D
FPOP FPOP S D
FPOPP FPOPP S D
FINS S D n
FINS
FINS S D n
FINSP
FDEL S D n
FDEL
FDELP S D n
FDELP
- 95 -