Awex 2014
Awex 2014
VER.14.2
Awex brand has been existing in the emergency tests
lighting sector since 2002, invariably fulfilling its clearly
defined mission: top-quality state-of-the-art products The research and development works ensure that our
and customer satisfaction. We offer the full range of offer is constantly updated according to development
emergency lighting devices in compliance with all the trends in the industry, and thus we can supply the most
European standards. Within 10 years of our market modern, multifunctional and technologically advanced
presence, we gained the leading position in the industry products.
thanks to the involvement of knowledge, means,
cooperation with best specialists, including research We take care of the environment
facilities, and investments in innovative projects.
Awex means the latest technologies, experienced We offer the environment-friendly products and the
team of designers and engineers, top quality, reliable manufacturing process meets strict EU standards.
equipment, diversity of offer, unique design, unlimited
productivity and unblemished reputation supported Quality Warranty
by references. The biggest award is satisfied and
trusted customers. We also enjoy the recognition of With the aim of fulfilling the company’s mission,
independent experts. We were awarded the title of we implemented the quality management system
the “Export Leader 2006” for our business volume, and according to EN ISO 9001:2008, and the certificate
the Puls Biznesu awarded us twice with the “Business issued by TÜV NORD ensures top quality of design,
Gazelles” prize as one of the most dynamically manufacture, assembly and servicing of emergency
developing companies in Poland. lighting equipment.
Professional Personnel
investments
AXN 6
AXP8
LOVATO N 10
LOVATO P 12
EYE LED round 14
EYE LED square 16
EYE18
INFINITY PO 19
SPY 20
HELIOS LED 22
HELIOS24
EMX25
TIGER LED 26
TIGER27
PANORAMA & PANORAMA LED 28
OUTDOOR LED 29
SQUARE30
Twister31
HERMETICA32
JOBLED33
MATERIALS:
White polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (118lm), C 1W (114lm) or
O 3W (283lm), C 3W (287lm) or
O 6W (575lm), C 6W (600lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h or 8h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
202
IP42 or IP65
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 202 58
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery 220-240V
216V 24V
ADDITIONAL INFORMATION: AC LED IP65
DC DC
50-60Hz
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version Ni-MH
Optional adaptation of the fixture for low temperatures up to -25°C
6
Emergency escape lighting
Photometry
L1 L2
AXNC – LED 1W (114lm) with optics for escape route AXNO – LED 1W (118lm) with optics for open area
h [m] L1 L2 h [m] L1 L2
AXNC – LED 3W (287lm) with optics for escape route AXNO – LED 3W (283lm) with optics for open area
AXNC 3W – avg 1lx AXNO 3W – min 0,5lx
h [m] L1 L2 h [m] L1 L2
2,50 7,00 18,00 2,50 4,00 16,00
3,00 8,00 20,00 3,00 5,00 17,00
3,50 9,00 21,00 3,50 5,00 17,00
4,00 9,50 22,00 4,00 5,00 17,50
4,50 10,00 23,00 4,50 5,00 17,50
5,00 10,50 24,00 5,00 5,00 17,50
6,00 11,00 25,00 6,00 5,00 18,00
7,00 10,50 27,00 7,00 5,00 18,00
8,00 9,50 25,00 8,00 5,00 18,00
9,00 9,00 23,00 9,00 5,00 18,00
10,00 7,00 19,00 10,00 4,00 17,00
AXNC – LED 6W (600lm) with optics for escape route AXNO – LED 6W (575lm) with optics for open area
AXNC 6W – avg 1lx (SE mode) AXNO 6W – min 0,5lx (SE mode)
h [m] L1 L2 h [m] L1 L2
2,50 11,00 24,00 2,50 8,00 18,00
3,00 12,00 26,00 3,00 8,00 20,00
3,50 12,50 27,00 3,50 8,00 21,00
4,00 12,50 29,00 4,00 8,00 22,00
4,50 13,00 30,00 4,50 8,00 23,00
5,00 13,50 31,00 5,00 8,00 23,50
6,00 14,50 33,00 6,00 8,00 24,00
7,00 15,00 34,00 7,00 8,00 24,00
8,00 15,50 36,00 8,00 8,00 25,00
9,00 15,50 37,00 9,00 8,00 25,00
10,00 15,50 38,00 10,00 8,00 25,00
11,00 13,50 39,00 11,00 8,00 25,00
12,00 12,50 39,00 12,00 7,00 25,00
7
Emergency escape lighting
AXP
MATERIALS:
White polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (118lm), C 1W (109lm) or
O 3W (285lm), C 3W (265lm) or
O 6W (616lm), C 6W (523lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h or 8h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
100
IP20 or IP65/20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 100 37
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery 220-240V
216V 24V
ADDITIONAL INFORMATION: AC LED IP20 IP65/20
DC DC
50-60Hz
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version Ni-MH
h min. 150 mm
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION
AXPC 1 3 6 1 2 3 8* SE SA AT RS
AXPO 1 3 6 1 2 3 8* SE SA AT RS
AXEPC 1 3 6 1 2 3 8* SE SA AT RS
AXEPO 1 3 6 1 2 3 8* SE SA AT RS
*AVAILABLE WITH 1W VERSION ONLY
8
Emergency escape lighting
Photometry
L1 L2
AXPC – LED 1W (109lm) with optics for escape route AXPO – LED 1W (118lm) with optics for open area
AXPC 1W – avg 1lx AXPO 1W – min 0,5lx
h [m] L1 L2 h [m] L1 L2
2,50 6,00 13,00 2,50 4,00 11,00
3,00 6,00 14,50 3,00 3,00 12,00
3,50 6,50 15,00 3,50 3,00 12,00
4,00 6,50 15,00 4,00 3,00 12,00
4,50 6,50 16,00 4,50 3,00 12,00
5,00 6,50 16,00 5,00 3,00 12,00
6,00 5,50 9,00 6,00 3,00 11,50
7,00 5,50 6,00 7,00 2,50 10,00
8,00 5,50 6,00 8,00 2,00 9,00
AXPC – LED 3W (265lm) with optics for escape route AXPO – LED 3W (285lm) with optics for open area
AXPC – LED 6W (523lm) with optics for escape route AXPO – LED 6W (616lm) with optics for open area
AXPC 6W – avg 1lx (SE mode) AXPO 6W – min 0,5lx (SE mode)
h [m] L1 L2 h [m] L1 L2
9
Emergency escape lighting
LOVATO N
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (118lm), C 1W (114lm) or
O 3W (249lm), C 3W (238lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
120
IP41
120
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
AT – autotest 120 40
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 220-240V
216V 24V
LED indicator signalizes mains power supply and battery charge AC LED IP41
DC DC
50-60Hz
Deep discharge protection
III class of insulation of FZLV version
Ni-MH
10
Emergency escape lighting
LVNC – LED 1W (114lm) with optics for escape route
11
Emergency escape lighting
LOVATO P
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (121lm), C 1W (122lm) or
O 3W (242lm), C 3W (238lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP20
95
95
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
95 47,7
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 220-240V
216V 24V
LED indicator signalizes mains power supply and battery charge AC LED IP20
DC DC
50-60Hz
Deep discharge protection
III class of insulation of FZLV version
Ni-MH
h min. 150 mm
12
Emergency escape lighting
LVPC – LED 1W (122lm) with optics for escape route
Photometry
LVPC 3W – avg 1lx
h [m] L1 L2 L1 L2
2,50 7,50 16,50
3,00 8,50 18,50
h
3,50 9,00 21,00
4,00 9,00 22,50
4,50 9,50 22,50
5,00 10,00 23,00 L1 – distance from the wall to the first fixture
6,00 11,00 25,00 L2 – distance between fixtures
7,00 11,00 24,00 h – height of the ceiling
8,00 10,00 21,00
13
Emergency escape lighting
EYE LED round
MATERIALS:
Body made of stainless steel or steel painted white,
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (117 lm), C 1W (110 lm) or
O 3W (259 lm), C 3W (241 lm) or
3x1W (255 lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
47
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 80 80
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
CB – central battery AC LED IP20
DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection Ni-MH
III class of insulation of FZLV version
h min. 150 mm
Legend:
SE – non maintained
CENTRAL BATTERY CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM OPTION COLOR
AT – autotest
EYO 1 3 CB CBS ADS ADL ST WH RS – Rubic central monitoring
EYC 1 3 CB CBS ADS ADL ST WH FZLV – fixture for central battery FZLV 24 VDC
EY 3x1 CB CBS ADS ADL ST WH CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
FZLV SYSTEM CONFIGURATION ADL – central battery with address module ADL
EYO – fixture Eye led with optics for open area
CODE POWER [W] SYSTEM COLOR
EYC – fixture Eye led with optics for escape route
EYO 1 3 FZLV ST WH
EY – fixture Eye led
EYC 1 3 FZLV ST WH ST – stainless steel
EY 3x1 FZLV ST WH WH – fixture in white color
14
Emergency escape lighting
EYO – LED 1W (117lm) with optics for open area
h
EYC – LED 1W (110lm) with optics for escape route
15
Emergency escape lighting
EYE LED square
MATERIALS:
Body made of stainless steel or steel painted white
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (117 lm), C 1W (110 lm) or
O 3W (259 lm), C 3W (241 lm) or
3x1W (255 lm) power LED
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
47
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 80 80
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
CB – central battery AC LED IP20
DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection Ni-MH
III class of insulation of FZLV version
h min. 150 mm
Legend:
SE – non maintained
CENTRAL BATTERY CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM OPTION COLOR
AT – autotest
EYKO 1 3 CB CBS ADS ADL ST WH RS – Rubic central monitoring
EYKC 1 3 CB CBS ADS ADL ST WH FZLV – fixture for central battery FZLV 24 VDC
EYK 3x1 CB CBS ADS ADL ST WH CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
FZLV SYSTEM CONFIGURATION ADL – central battery with address module ADL
EYKO – fixture Eye led square with optics for open area
CODE POWER [W] SYSTEM COLOR
EYKC – fixture Eye led square with optics for escape route
EYKO 1 3 FZLV ST WH
EYK – fixture Eye led square
EYKC 1 3 FZLV ST WH ST – stainless steel
EYK 3x1 FZLV ST WH WH – fixture in white color
16
Emergency escape lighting
EYKO – LED 1W (117lm) with optics for open area
h
EYKC – LED 1W (110lm) with optics for escape route
17
Emergency escape lighting
EYE
MATERIALS:
Body made of stainless steel or steel painted white,
other colors optionally
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W (255 lm) power LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP44/20
47
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained 95 95
SA – maintained
AT – autotest
RS – Rubic central monitoring 220-240V
216V 24V IP44/20
AC LED
FZLV – central battery FZLV 24V DC DC
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Ni-MH
Deep discharge protection
III class of insulation of FZLV version
Dimension of assembly hole Ø 60mm
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
4EY 3x1 1 2 3 SE SA AT RS ST WH
h min. 150 mm
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION COLOR
Legend:
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
4EY – fixture Eye
ST – stainless steel 4EY – min 0,5lx open area 4EY – avg 1lx escape route
WH – fixture in white color h [m] L1 L2 h [m] L1 L2
18
Emergency escape lighting
INFINITY PO
MATERIALS:
White, grey or black polycarbonate body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W (227 lm) power LED
Open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
70
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
II 330 45
IP RATING:
IP44
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 220-240V
216V 24V
AC LED IP44
SE – non maintained DC DC
50-60Hz
SA – maintained
PT – manual test button
AT – autotest Ni-MH
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: Photometry
LED indicator signalizes mains power supply and battery charge
Deep discharge protection L1 L2
III class of insulation of FZLV version
h
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
IFAPO 3x1 1 2 3 SE SA PT AT RS WH GR BL
L1 – distance from the wall to the first fixture
L2 – distance between fixtures
CENTRAL BATTERY CONFIGURATION
h – height of the ceiling
CODE POWER [W] SYSTEM OPTION COLOR
IFAPO 3x1 CB CBS ADS ADL WH GR BL IFAPO 3x1W (227lm)
BZ7 =100%
135° 150° 180° 150° 135°
FZLV SYSTEM CONFIGURATION 320
CODE POWER [W] SYSTEM COLOR 120° 120°
160
IFAPO 3x1 FZLV WH GR BL 105° 105°
90° 90°
75° 75°
160
60° 60°
320
45° 45°
480
Legend: 30° 15° 0° 15° 30°
SE – non maintained I(0°)=127cd/klm[ cd/klm]
SA – maintained C0-C180 C90-C270
19
Emergency escape lighting
SPY
MATERIALS:
Body made of aluminum or aluminum painted white
MOUNTING:
Inside light fitting
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
O 1W (117 lm), C 1W (110 lm) or
O 3W (259 lm), C 3W (241 lm)
Escape route or open area optics
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
63
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C 63 50 - 82 10
OPTIONS:
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
Ni-MH
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION COLOR
Legend:
SE – non maintained
SA – maintained
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
SPO – fixture SPY with optics for open area
SPC – fixture SPY with optics for escape route
WH – fixture in white color
SR – fixture in silver color
20
Emergency escape lighting
SPO – LED 1W (117lm) with optics for open area
Photometry
L1 L2
SPO – LED 3W (259lm) with optics for open area
21
Emergency escape lighting
HELIOS LED
MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W (257 lm) LED
3x1W (275 lm) or 2x3W (436 lm) power LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP42 or IP65
136
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 356 79
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
CB – central battery AC LED IP42 IP65
DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection Ni-MH
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version
22
Emergency escape lighting
HWM – LED 3,2W (257lm) for 2,5 to 10 m
HWM – min 0,5lx open area HWM – avg 1lx escape route
h [m] L1 L2 h [m] L1 L2
2,50 5,00 10,00 2,50 5,50 10,00
3,00 5,00 11,00 3,00 5,50 11,00
3,50 6,00 11,50 3,50 6,00 11,50
4,00 6,00 12,50 4,00 6,00 12,00
4,50 7,00 13,00 4,50 6,00 12,50
5,00 7,00 14,00 5,00 6,00 13,00
5,50 7,00 15,00 5,50 6,00 13,00
6,00 7,00 15,00 6,00 6,00 13,00
6,50 7,00 15,50 6,50 5,60 13,00
7,00 7,00 16,00 7,00 5,50 13,00
7,50 7,00 17,00 7,50 5,00 12,50
8,00 7,00 17,00 8,00 3,00 12,50
9,00 7,00 17,50 9,00 2,50 12,00
10,00 7,00 18,00 10,00 2,50 12,00
Photometry
L1 L2 L3 L4
h h
L1 – distance from the wall to the first fixture L3 – distance from the wall to the first fixture
L2 – distance between fixtures L4 – distance between fixtures
h – height of the ceiling h – height of the ceiling
23
Emergency escape lighting
HELIOS
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover with Fresnel optics
MOUNTING:
Surface (wall, ceiling)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
8W, 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
136
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP42 or IP65 356 79
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
230V
OPTIONS: 216V
AC T5 TC-SEL IP42 IP65
DC G5 2G7
SE – non maintained 50-60Hz
SA – maintained
PT – manual test button Ni-Cd
AT – autotest
RS – Rubic central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
H 8 11 18* 1 2 3 SE SA PT AT RS
* AVAILABLE ONLY IN NON-MAINTAINED VERSION
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
H – fixture Helios IP 65
HE – fixture Helios IP 42
24
Emergency escape lighting
EMX
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
2x8W, 18W, 24W, 36W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
160
INSULATION CLASS:
I
IP RATING:
IP65
400 100
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained 230V
216V
AC T5 TC-L IP65
SA – maintained DC G5
50-60Hz 2G11
PT – manual test button
AT – autotest
RS – RUBIC central monitoring Ni-Cd EVG
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
EM 2x8 18 24 36 1 2 3 SE SA PT AT RS
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
EM – fixture EMX
25
Emergency escape lighting
TIGER LED
MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery –220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE: 323
3,2W LED (270 lm)
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
144
118
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP22 350
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
220-240V
OPTIONS: AC
216V 24V
LED IP22
DC DC
SE – non maintained 50-60Hz
SA – maintained
PT – manual test button
Ni-MH
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
Photometry
CB – central battery
ADDITIONAL INFORMATION: L1 L2
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C h
III class of insulation of FZLV version
Legend:
TL 3,2W – avg 1lx escape route TL 3,2W – min 0,5lx open area
SE – non maintained transparent cover transparent cover
SA – maintained
h [m] L1 L2 h [m] L1 L2
PT – manual test button
AT – autotest 2,50 4,00 10,00 2,50 4,00 10,00
26
Emergency escape lighting
TIGER
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall, ceiling)
Optional assembly in dry-wall or under plastering
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries 323
INSULATION CLASS:
II
IP RATING:
IP22
144
118
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 350
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 230V
216V
Deep discharge protection AC T5 IP22
DC G5
50-60Hz
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
Ni-Cd
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TG – fixture Tiger
27
Emergency escape lighting
PANORAMA & PANORAMA LED
MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24 VDC
LIGHT SOURCE:
8W, 11W fluorescent lamp
3,2W LED
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP54
AMBIENT TEMPERATURE:
185
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 330 45
RS – RUBIC central monitoring
FZLV – central battery FZLV
CB – central battery 220-240V
216V
216V 24V
24V
AC T5 TC-SEL
TC-SEL LED
ADDITIONAL INFORMATION: DC DC G5 2G7
2G 7
50-60Hzz
50-60H
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version Ni-Cd
Ni-Cd EVG
EVG
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
FZLV – central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
P – fixture Panorama
PML – fixture Panorama LED
28
Emergency escape lighting
OUTDOOR LED
MATERIALS:
Stainless steel painted white
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24 VDC
LIGHT SOURCE:
3x1W (256lm) power LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY & BATTERIES:
1h, 2h, or 3h, Ni-MH batteries
INSULATION CLASS:
I
IP RATING:
IP 65 222
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
227
SA – maintained
AT – autotest
RS – RUBIC central monitoring
77
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 220-240V
216V
216V 24V
24V
Deep discharge protection AC
DC DC
LED IP65
50-60Hzz
50-60H
III class of insulation of FZLV version
29
Emergency escape lighting
SQUARE
MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
1x 11W, 18W fluorescent lamp
2x 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP54
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
360
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 360 83
Deep discharge protection
SD – 18W
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
SD – fixture Square
30
Emergency escape lighting
Twister
MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall, ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
1x 11W, 18W fluorescent lamp
2x 11W, 18W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP54
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
360
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 360 83
Deepdischargeprotection
TD – 18W
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TD – fixture Twister
31
Emergency escape lighting
HERMETICA
MATERIALS:
Grey polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (ceiling)
POWER SUPPLY: A
Self contained – 220÷240VAC/50÷60Hz D
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
1x 14, 18, 24, 28, 35, 36, 49, 54, 58, 80W fluorescent lamp
2x 14, 18, 24, 28, 35, 36, 49, 54, 58, 80W fluorescent lamp
CHARGING:
113
100
Maximum 12h
AUTHONOMY AND BATTERIES:
1h, 2h or 3h, Ni-Cd batteries 140 90
INSULATION CLASS:
I
IP RATING:
220-240V
IP65 216V
AC IP65 T8 T5
DC G13 G5
AMBIENT TEMPERATURE: 50-60Hz
ta: 0°C÷40°C
OPTIONS: Ni-Cd EVG
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – RUBIC central monitoring
CB – central battery Dimensions [mm]
Photometry
SELF CONTAINED CONFIGURATION
HR – 1x18W HR – 2x18W
CODE POWER [W] AUTONOMY [h] mode OPTION
HR 14 2x14 1 2 3 SE SA PT AT RS
HR 18 2x18 1 2 3 SE SA PT AT RS
HR 24 2x24 1 2 3 SE SA PT AT RS
HR 28 2x28 1 2 3 SE SA PT AT RS
HR 35 2x35 1 2 3 SE SA PT AT RS
HR 36 2x36 1 2 3 SE SA PT AT RS
HR 49 2x49 1 2 3 SE SA PT AT RS
HR 54 2x54 1 2 3 SE SA PT AT RS
HR 58 2x58 1 2 3 SE SA PT AT RS
HR 80 2x80 1 2 3 SE SA PT AT RS
32
Emergency escape lighting
JOBLED
MATERIALS:
Black, hit resistant polycarbonate
POWER SUPPLY:
230 VAC/50Hz optionally – 12 VDC
LIGHT SOURCE:
3W (120 lm) highpower LED
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
8,5h 6V / 4,0 Ah batteries
INSULATION CLASS:
II
IP RATING:
IP43
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Charging through wall mounted adapter or directly from mains 230V
132
SELF CONTAINED CONFIGURATION 128
CODE POWER [W] AUTONOMY [h]
130
112
80 55 Ø130
230V
AC IP43
DC
50-60Hz
33
emergency exit signS
SK-836
INFINITY B 37
INFINITY AC & INFINITY AS 38
INFINITY AD & INFINITY AR 39
TWINS40
PLEXI LED 41
ESCAPE & ESCAPE LED 42
HELIOS & HELIOS LED 43
HELIOS DS & HELIOS DS LED 44
HELIOS P & HELIOS P LED 45
TIGER & TIGER LED 46
TIGER DS & TIGER DS LED 47
TIGER P & TIGER P LED 48
PANORAMA & PANORAMA LED 49
SCREEN50
SCREEN DS 51
EMX52
QUADRO53
MATERIALS:
White polycarbonate body
Opal or transparent polycarbonate cover
MOUNTING:
Surface (ceiling, wall)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W or 3,2W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
II
IP RATING: 310
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
250
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 20
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery 220-240V
216V 24V
AC LED IP44
ADDITIONAL INFORMATION: DC DC
50-60Hz
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Ni-Cd
III class of insulation of FZLV version
d=30m
Legend:
SE – non maintained
SA – maintained
PT - manual test button
AT - autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
SK8 - fixture SK-8
WT - white body and transparent cover
WL - white body and opal cover
GT - grey body and transparent cover
GL - grey body and opal cover
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
36
ONE-sided emergency exit signs
INFINITY B
MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Recessed (wall)
Surface (wall)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II 28 43
IP RATING:
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
180
123
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 330
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 220-240V
216V 24V
AC LED IP44
CB – central battery DC DC
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Ni-MH
Deep discharge protection
d=30m
III class of insulation of FZLV version
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
IFB – fixture Infinity B
WH – fixture in white color
GR – fixture in grey color
BL – fixture in black color
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
37
Two-sided emergency exit signs
INFINITY AC & INFINITY AS
MATERIALS:
White, grey or black polycarbonate body
Plexi glass
MOUNTING:
Surface (ceiling, rope sling)
Optional wall assembly using the bracket
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP44
VIEWING DISTANCE: 330 45
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
70
OPTIONS:
SE – non maintained
250
SA – maintained
180
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V infinity ac 15
CB – central battery
ADDITIONAL INFORMATION: 330
LED indicator mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
70
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION COLOR
max 1m
IFAC 3,2 1 2 3 SE SA PT AT RS WH GR BL
180
IFAS 3,2 1 2 3 SE SA PT AT RS WH GR BL
220-240V
FZLV SYSTEM CONFIGURATION 216V 24V
AC LED IP44
DC DC
CODE POWER [W] SYSTEM COLOR 50-60Hz
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
38
ssTwo-sided emergency exit signs
MATERIALS:
Steel body in gray, black or white color
Plexi glass in grey, black or white polycarbonate frame
MOUNTING:
Recessed (ceiling, rope sling)
POWER SUPPLY:
Self contained – 220÷240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-MH batteries
INSULATION CLASS:
II
IP RATING:
IP44
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
39
Two-sided emergency exit signs
TWINS
MATERIALS:
Silver or black aluminium body
Plexi glass
MOUNTING:
Surface (ceiling, wall)
Assembly on rope slings or wall mounting bracket as an option
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING: 315 48
IP41
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
83
ta: 0°C÷40°C
OPTIONS:
243
SE – non maintained
SA – maintained
160
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 230V
216V 24V
AC LED T5 IP41
LED indicator signalizes mains power supply and battery charge DC DC G5
50-60Hz
Deep discharge protection
III class of insulation of FZLV version
Ni-Cd
SELF CONTAINED CONFIGURATION
CODE POWER [W] AUTONOMY [h] MODE OPTION
TW 1,2 8 1 2 3 SE SA PT AT RS EVG
TWB 1,2 8 1 2 3 SE SA PT AT RS d=30m
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TW – fixture Twins
TWB – fixture Twins black
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
40
ssTwo-sided emergency exit signs
PLEXI LED
MATERIALS:
Steel body in grey or white color
Plexi glass
MOUNTING:
Recessed (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP20 325 45
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
210
170
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 355 110
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 230V
216V 24V
AC LED T5 IP20
Deep discharge protection DC DC G5
50-60Hz
III class of insulation of FZLV version
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
PL – fixture Plexi led
GR – fixture in grey color
Wh – fixture in white color
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
41
Two-sided emergency exit signs
ESCAPE & ESCAPE LED
MATERIALS:
Steel body in white color
Plexi glass
MOUNTING:
Surface (ceiling)
Optional wall assembly using the bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
I 352 60
IP RATING:
IP20
VIEWING DISTANCE:
69
30m
AMBIENT TEMPERATURE:
228
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP20
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
EVG
SELF CONTAINED CONFIGURATION
d=30m
CODE POWER [W] AUTONOMY [h] MODE OPTION
E 8 1 2 3 SE SA PT AT RS
EL 1,2 1 2 3 SE SA PT AT RS
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
E – fixture Escape
EL – fixture Escape LED
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
42
ONE-sided emergency exit signs
HELIOS & HELIOS LED
MATERIALS:
White polycarbonate body
Transparent cover with Fresnel optics or opal polycarbonate cover
MOUNTING:
Surface (wall)
Optional assembly with wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
II
136
IP RATING:
IP42 or IP65
VIEWING DISTANCE:
25m
356 79
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP42 IP65
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version
HL 1,2 1 2 3 SE SA PT AT RS OP
*see pictogram
HEL 1,2 1 2 3 SE SA PT AT RS OP
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
43
Two-sided emergency exit signs
HELIOS DS & HELIOS DS LED
MATERIALS:
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS: 356 136
II
IP RATING:
IP42 or IP65
VIEWING DISTANCE:
25m
219
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 33
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 230V
216V 24V
AC LED T5 IP42
CB – central battery DC DC G5
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Ni-Cd
Deep discharge protection IP65
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – IK08
III class of insulation of FZLV version EVG
d=25m
HDL 1,2 1 2 3 SE SA PT AT RS
*see pictogram
HDEL 1,2 1 2 3 SE SA PT AT RS
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
44
ssTwo-sided emergency exit signs
MATERIALS:
White polycarbonate body
Transparent cover with Fresnel optics
Plexi glass
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS: 356 136
II
IP RATING:
IP42
VIEWING DISTANCE:
30m
225
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP42
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd EVG
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
Protection against mechanical impacts – Ik07
III class of insulation of FZLV version d=30m
*see pictogram
Legend:
FZLV SYSTEM CONFIGURATION SE – non maintained
CODE POWER [W] SYSTEM SA – maintained
PT – manual test button
HPL 1,2 FZLV
AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
HP – fixture Helios P
HPL – fixture Helios P LED
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
45
ONE-sided emergency exit signs
MATERIALS:
White polycarbonate body
Transparent or opal polycarbonate cover
MOUNTING:
Surface (wall)
Optional assembly in dry-wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES: 323
1h, 2h, 3h, Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
144
118
IP22
VIEWING DISTANCE:
20m
AMBIENT TEMPERATURE:
350
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 230V
216V 24V
AC LED T5 IP22
RS – Rubic central monitoring DC DC G5
50-60Hz
FZLV – central battery FZLV 24V
CB – central battery
Ni-Cd EVG
ADDITIONAL INFORMATION:
d=20m
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
III class of insulation of FZLV version
*see pictogram
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
46
ssTwo-sided emergency exit signs
MATERIALS:
White polycarbonate body
Opal polycarbonate cover
MOUNTING:
Surface (ceiling)
Optional assembly in dry-wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
1,2W LED
8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
323 118
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP22
VIEWING DISTANCE:
186
20m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
350 144
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 230V
216V 24V
AC LED T5 IP22
FZLV – central battery FZLV 24V DC DC G5
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
Ni-Cd
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
EVG
d=20m
*see pictogram
Legend:
SE – non maintained
FZLV SYSTEM CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM
PT – manual test button
TSL 1,2 FZLV AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TGS – fixture Tiger DS
TSL – fixture Tiger DS LED
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
47
Two-sided emergency exit signs
TIGER P & TIGER P LED
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
Plexi glass
MOUNTING:
Surface (ceiling)
Optional assembly in dry-wall or ceiling bracket
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
8W fluorescent lamp
1,2W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES: 323 118
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP22
192
VIEWING DISTANCE:
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS: 350 144
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest 230V
216V 24V
AC LED T5 IP22
RS – Rubic central monitoring DC DC G5
50-60Hz
FZLV – central battery FZLV 24V
CB – central battery
Ni-Cd
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version EVG
d=30m
*see pictogram
Legend:
SE – non maintained
FZLV SYSTEM CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM
PT – manual test button
TPL 1,2 FZLV AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
TP – fixture Tiger P
TPL – fixture Tiger P LED
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
48
ONE-sided emergency exit signs
PANORAMA & PANORAMA LED
MATERIALS:
White plastic body
Opal plastic cover
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery–220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
8W fluorescent lamp
1,2W LED
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
II
IP RATING:
IP54
VIEWING DISTANCE:
185
30m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained 330 45
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V 230V
216V 24V
AC LED T5 TC-SEL IP54
CB – central battery DC DC G5 2G7
50-60Hz
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Ni-Cd EVG
Deep discharge protection
d=30m
III class of insulation of FZLV version
*see pictogram
P 8 CB CBS ADS
Legend:
SE – non maintained
FZLV SYSTEM CONFIGURATION
SA – maintained
CODE POWER [W] SYSTEM
PT – manual test button
PML 1,2 FZLV AT – autotest
RS – Rubic central monitoring
FZLV – fixture for central battery FZLV 24 VDC
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
P – fixture Panorama
PML – fixture Panorama LED
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
49
ONE-sided emergency exit signs
SCREEN
MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 220-240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
SC30 3x1W; SC40 3,2W; SC60 2x3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
I
IP RATING:
IP40
VIEWING DISTANCE:
b
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained a c d
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 220-240V
216V 24V
AC LED IP40
FZLV – central battery FZLV 24V DC DC
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Ni-MH
d=30m d=40m d=60m
Deep discharge protection
III class of insulation of FZLV version
*see pictogram
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
50
ssTwo-sided emergency exit signs
SCREEN DS
MATERIALS:
Aluminium body
Plexi glass
MOUNTING:
Surface (ceiling) or mounting on a rope sling
POWER SUPPLY:
Self contained – 220-240VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
SCS30 3x1W; SCS40 3,2W; SCS60 2x3,2W LED
CHARGING:
Maximum 12h; energy-saving electronic impulse charger
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-MH batteries
INSULATION CLASS:
I
IP RATING:
IP40
VIEWING DISTANCE:
b
30, 40 or 60m (depends on version)
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained a c
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring 220-240V
216V 24V
AC LED IP40
FZLV – central battery FZLV 24V DC DC
50-60Hz
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge Ni-MH
d=30m d=40m d=60m
Deep discharge protection
III class of insulation of FZLV version
*see pictogram
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
51
ONE-sided emergency exit signs
EMX
MATERIALS:
White polycarbonate body
Transparent polycarbonate cover
MOUNTING:
Surface (wall)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
LIGHT SOURCE:
2x8W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP65
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
160
OPTIONS:
SE – non maintained
SA – maintained
PT – manual test button
400 100
AT – autotest
RS – Rubic central monitoring
CB – central battery
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Optional adaptation of the fixture for low temperatures up to -25°C
230V
216V
AC T5 IP65
DC G5
50-60Hz
Ni-Cd EVG
d=25m
*see pictogram
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION
Legend:
SE – non maintained
SA – maintained
PT – manual test button
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
EM – fixture EMX
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
52
Four-sided emergency exit signs
QUADRO
MATERIALS:
Opal plexi glass body
MOUNTING:
Surface (ceiling)
POWER SUPPLY:
Self contained – 230VAC/50÷60Hz
Central battery – 220÷240VAC/50÷60Hz; 216VDC
Central battery FZLV – 24VDC
LIGHT SOURCE:
3x1W LED
11W fluorescent lamp
CHARGING:
Maximum 24h
AUTONOMY AND BATTERIES:
1h, 2h, 3h , Ni-Cd batteries
INSULATION CLASS:
I
IP RATING:
IP41
VIEWING DISTANCE:
25m
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
OPTIONS:
SE – non maintained
SA – maintained
240
PT – manual test button
AT – autotest
RS – Rubic central monitoring
FZLV – central battery FZLV 24V
CB – central battery
ADDITIONAL INFORMATION: 240
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
III class of insulation of FZLV version
230V
24V
AC TC-SEL LED
DC 2G7
50-60Hz
Ni-Cd EVG
d=25m
*see pictogram
CENTRAL BATTERY CONFIGURATION
CODE POWER [W] SYSTEM OPTION
Legend:
FZLV SYSTEM CONFIGURATION SE – non maintained
CODE POWER [W] SYSTEM SA – maintained
PT – manual test button
Q 3x1 FZLV
AT – autotest
RS – Rubic central monitoring
CB – central battery
CBS – central battery (circuit monitoring)
ADS – central battery with address module ADS 20
ADL – central battery with address module ADL
Q – fixture Quadro
*Emergency exit sign fixtures do not include any pictogram in the set. Pictograms have to be chosen and ordered as a separate item.
53
emergency conversion kits
NEXT & NEXT NEXT PLUS LIDER EVG LIDER PLUS LIN LINEX & LINEX UNILED BM
AUTOTEST & NEXT PLUS & LIDER PLUS AUTOTEST
AUTOTEST AUTOTEST
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
230 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
35
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
42
A new generation of conversion kits which replaces conversion kits series LIDER
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 157
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
230V
Ni-Cd
AC IP20
50-60Hz
56
emergency conversion kits
NEXT PLUS & NEXT PLUS AUTOTEST
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd or Ni-MH battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
35
ta: 0°C÷55°C
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
42
A new generation of conversion kits which replaces conversion kits series LIDER
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 157
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
220-240V
Ni-Cd Ni-MH
AC IP20
50-60Hz
57
emergency conversion kits
LIDER EVG
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
230 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
35
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
42
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Cooperation with magnetic and electronic ballasts
157
Optional adaptation of conversion kit for low temperatures up to -25°C
230V
Ni-Cd
AC IP20
50-60Hz
58
emergency conversion kits
LIDER PLUS & LIDER PLUS AUTOTEST
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear and compact fluorescent lamps
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-Cd or Ni-MH battery
INSULATION CLASS:
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
35
OPTIONS:
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
42
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Cooperation with magnetic and electronic ballasts
157
Optional adaptation of conversion kit for low temperatures up to -25°C
220-240V
Ni-Cd Ni-MH
AC IP20
50-60Hz
LEP PLUS AUTOTEST - ORDER CODES LIDER Ni-MH AUTOTEST - ORDER CODES
CODE POWER [W] AUTONOMY [h] BATTERY CODE POWER [W] AUTONOMY [h] BATTERY
59
emergency conversion kits
LIN
MATERIALS:
White polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear fluorescent T5 lamp
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
30
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-MH battery (optionally Ni-Cd battery*)
INSULATION CLASS:
II
IP RATING:
IP20
22
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
OPTIONS: 284
PT – manual test button
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 220-240V
Ni-Cd Ni-MH
AC IP20
Cooperation with magnetic and electronic ballasts 50-60Hz
Optional adaptation of conversion kit for low temperatures up to -25°C
Long life of the LF lamp due to the function of the preheating of electrodes
Stabilization of lightstream
60
emergency conversion kits
LINEX & LINEX AUTOTEST
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz
LIGHT SOURCE:
Linear fluorescent T5 lamp
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
30
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-MH battery (optionally Ni-Cd battery*)
INSULATION CLASS:
II
IP RATING:
IP20
22
AMBIENT TEMPERATURE:
ta: 0°C÷55°C
OPTIONS: 284
PT – manual test button
AT – autotest
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge 220-240V
Ni-Cd Ni-MH
AC IP20
Deep discharge protection 50-60Hz
Cooperation with magnetic and electronic ballasts
Optional adaptation of conversion kit for low temperatures up to -25°C
Long life of the LF lamp due to the function of the preheating of electrodes
Stabilization of lightstream
61
emergency conversion kits
UNILED BM
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240 VAC/50-60 Hz; 216 VDC
LIGHT SOURCE:
1W, 3W, 6W* LED
CHARGING:
Maximum 12h; electronic energy-saving impulse charger
AUTONOMY & BATTERIES:
1h, 2h or 3h; Ni-MH battery (optionally Ni-Cd battery)
INSULATION CLASS:
22
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
38
ta: 0°C÷40°C
OPTIONS:
PT – manual test button 134
AT – autotest
ADDITIONAL INFORMATION:
LED indicator signalizes mains power supply and battery charge
Deep discharge protection 220-240V
Ni-Cd Ni-MH
Optional adaptation of conversion kit for low temperatures up to -25°C AC IP20
50-60Hz
Automatic detection of battery capacity and setting test parameters
Output voltage: 3.3 VDC
* 6W – power of light source only in non-maintained fixtures
62
emergency conversion kits
UNILED GU10
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
230VAC/50-60Hz
LIGHT SOURCE:
3,5–8W LED
CHARGING:
Maximum 24h
AUTONOMY & BATTERIES:
1h or 3h; Ni-Cd battery
INSULATION CLASS:
35
II
IP RATING:
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷40°C
42
OPTIONS:
PT – manual test button
ADDITIONAL INFORMATION: 157
LED indicator signalizes mains power supply and battery charge
Deep discharge protection
Designed for cooperation with LED light sources with voltage 180VDC 230V
Ni-Cd
In emergency mode light stream is 80% of the nominal stream AC IP20
50-60Hz
63
emergency conversion kits
UNILED UM
MATERIALS:
Polycarbonate body
MOUNTING:
In the fixture
POWER SUPPLY:
220÷240VAC/50÷60Hz
LIGHT SOURCE:
Power mode: max 80W
Voltage mode: max 9W
Designed for cooperation with LED light sources with voltage 12V - 90VDC - max 80W
OUTPUT POWER:
1 - 9W (10mA - 750mA)
35
CHARGING:
Maximum 12h or 24h; depending on battery capacity
AUTONOMY & BATTERIES:
1h, 3h lub 8h, Batteries Ni-MH, Ni-Cd
Autonomy 1h, 3h, 8h set by jumper
42
INSULATION CLASS:
II
IP RATING: 157
IP20
AMBIENT TEMPERATURE:
ta: 0°C÷50°C
OPTIONS: 220-240V
Ni-Cd Ni-MH
PT – manual test button AC IP20
50-60Hz
AT – autotest
RS – Rubic central monitoring
ADDITIONAL INFORMATION:
Deep discharge protection
Optional adaptation of conversion kit for low temperatures up to -25°C
Automatic detection of battery capacity and setting test parameters
Automatic detection of LED light source voltage in Power mode
In emergency mode (Power or Voltage), the incorrect settings
are detected by LED indicator
AUTONOMY [h]
Type of battery
1h 3h 8h
7,2V 1000mAh 3W 1W –
Ni-MH/Ni-Cd
7,2V 4000mAh 9W 5W 2W
7,2V 8000mAh 9W 9W 4W
=
light output in emergency mode LED power in emergency mode
=
LED power in emergency mode [W]
light output in emergency mode [lm] x light output in mains mode [lm]
LED power in mains mode [W]
64
emergency conversion kits
Voltage mode Settings
LED
UNILED UM power supply
max. 9W
OFF
7,2V 1500mAh 0,41 0,20 0,14 0,10 0,08 0,05 0,41 0,08 0,06 0,04 0,03 0,02 0,41 0,03 0,02 0,02 0,01 0,01
Ni-MH/Ni-Cd
7,2V 2500mAh 0,68 0,34 0,23 0,17 0,14 0,09 0,28 0,14 0,09 0,07 0,06 0,04 0,11 0,06 0,04 0,03 0,02 0,02
7,2V 4000mAh 0,75 0,54 0,36 0,27 0,22 0,14 0,45 0,23 0,15 0,11 0,09 0,06 0,18 0,09 0,06 0,05 0,04 0,02
7,2V 8000mAh 0,75 0,75 0,72 0,54 0,43 0,29 0,75 0,45 0,30 0,23 0,18 0,12 0,36 0,18 0,12 0,09 0,07 0,05
UM 10 CD MH B1 B2 B3 PT AT RS
UM 15 CD MH B1 B2 B3 PT AT RS
UM 25 CD MH B1 B2 B3 PT AT RS
UM 40 CD MH B1 B2 B3 PT AT RS
UM 80 CD MH B1 B2 B3 PT AT RS
65
systems
RUBIC UNA 68
RUBIC MINI UNA 69
Central Battery system FZLV 70
Central battery system LPS 72
Central Battery system CBS 74
SMART VISIO PLATFORM 76
RUBIC UNA RUBIC MINI UNA Central Central Central SMART VISIO
Battery battery Battery PLATFORM
system FZLV system LPS system CBS
systems
RUBIC UNA
• Touch panel
• Unique addresses of luminaires
• Address programmer not required
• Proper polarization of connection of bus communication line is not
required
• Legible, big touchscreen LCD with a simple menu
• 4 potential-free 24V inputs
• 4 potential-free 24V outputs
• RJ45 connector for direct communication with any computer via
Ethernet,
• Preview of the system via any web browser
• Monitoring up to 750 of emergency fittings
• The quantity of the monitored fittings within one system can be
expanded up to 4000 emergency fittings
• Displaying the current system state
• Monitor emergency luminaires equipped with autonomous power
The Rubic UNA system is the latest and the most advanced version of supply RS sources, both fluorescent and LED
the monitoring system which controls independent fittings of emergency • Internal battery supporting power supply of the central unit
and evacuation lighting. Each control unit can control up to 4000 fittings • Automated testing
by using MPU250 submodules. Submodules communicate with the central • SD card slot and card itself allow to save the periodic test results, event
RUBIC UNA via LAN. Due to the connection through the LAN it is possible log and system configuration, in accordance with EN 50172
to use the Wi - Fi connection between the submodules. • Posiibility to test the fittings individually or in a group
• Night operation mode activated with one digital button
RUBIC UNA has a touch panel with graphical, intuitive menu. This • Management and visualization of the system using dedicated software
allows you to configure the system in a simply and easy way without the SMART VISIO
use of SmartVISIO application. • Works with any BMS (Building Management System) by using the
Due to applied technical solutions, we have eliminated the importance potential-free contacts.
of polarization of connecting the communication bus directly to:
• RUBIC UNA central unit
• MP UNA submodules
• RS address modules
RS485
max. 1200m
RS485
max. 1200m
PC WWW
68
systems
RUBIC MINI UNA
The main advantages of the control unit are its small size and the
possibility of direct mounting on TH-35 rail (DIN-3). The system is maximally
simplified but has all the key features from the point of view of the user.
Each control unit is equipped with an input bus RS, RJ45 connector, three
LEDs indicating the status of the system, the reset button and the service
pin which is used to personalize the new IP address. Communication
with emergency RS luminaires is carried out by bus RS485 conducted
in RS485 standard. Length of a single bus in linear topology is 1200 m.
Communication with the luminaires is continuous.
RS485
max. 1200m
RS485
max. 1200m
LAN
max. 100m
ROUTER
INTERNET PC WWW
LAN
max. 100m
PC
69
systems
Central Battery system FZLV
Central battery system FZLV is a high-tech device created to power fittings and the introduction of all settings and parameters of the system
and monitor emergency lighting in buildings of small and medium size and with the use of the user interface. Statuses are displayed in both graphic
in closed fire zones. The system can work with up to 80 LED luminaires and text form. Using the central unit one can assign a name to the fitting
supplied by SELV 24V (Safety Extra-Low Voltage) and was designed in that will clearly help to identify the fittings installed in the system. Using the
SMART technology. central unit one can program and freely configure the emergency fittings
in constant, non-constant, switching and switching-dimming modes as well
The application of the SELV voltage ensures high level of safety of as night work mode. The system has its own IP address and RJ45 slot which
servicing of the system and its elements are compilant with the currently is used for direct connection to Ethernet. With an built-in WEB module you
valid regulations. Small dimensions of the central unit enable the can directly access the system from any computer and print the event log
installation of the system in places where one cannot fit a large-size central by using any web browser. Additionally, the system has an input and an SD
battery system. The FZLV central unit is equipped with a big touch panel card that allows to record and upload system settings (back-up) and the
enabling both the current reading of the status of the system, circuits and record of the reports of the Event Log in accordance with EN 50172.
1....20 1....20
1....20 1....20
1....20 1....20
1....20 1....20
1....20 1....20
1....20 1....20
PH90*
70
systems
The most important parameters:
• Possibility to store the system settings (back – up) on SD card
• Power supply and monitoring up to 80 individual LED fittings in SMART • Contained security light mode (night operation)
technology • Possibility to control fittings and some functions of the system via
• Safe supply SELV 24V terminals 24V and 230V
• SMART technology – any mode of a fitting • Testing of each fitting separately as well as group of fittings
• Easy to read, big LCD touch screen • Internal rechargeable battery with a designed life of 10 years
• Easy and intuitive menu with simple icons • RJ45 slot for direct connection to Ethernet
• Automated testing • Individual IP address
• Automatic detection and adding of the fittings to the system • Preview of the system via any web browser
• Built-in WEB module • Works with any BMS (Building Management System) by using the
• Programming and configuration of the fittings directly from the system module of potential-free contacts or a CAN-bus
• Communication with luminaires through the power supply cable • Unlimited grouping of systems and joint supervision by Smart Touch
• SD slot and SD card for recording, transmission and printing emergency Controller
lighting reports from any PC, in accordance with EN 50172 • Programmable emergency time operation for individual fixtures
access point
INTERNET
ROUTER
MAX 100m
MAX 100m
MAX 100m
MAX 100m
MAX 100m
MAX 100m
MAX 100m
1....20 1....20
1....20 1....20
1....20 1....20
1....20 1....20
1....20 1....20
1....20 1....20
PH90*
71
systems
Central battery system LPS
The LPS central battery system, offered by AWEX, is a small, The system enables emergency supplying of the fittings with a total
up-to-date, reliable and simple device. It has been designed in accordance power of 1500W for the time of 1h, or the fittings 500W - for 3h. With four
with the he applicable standards and with using SMART technology. Its sensor inputs installed in the steering module it is possible to control
functions are equivalent to the functions of CBS system, however, due fire zones through the use of sensors decay phases (CFZ), which control
to its small size and limited power the system is suitable for installation power supply to the switch board of power supply zone. In addition, the
in smaller buildings or buildings that require diversification of source of system can be expanded by ELS-230 modules, with nine voltage control
supply of emergency fittings (as a group system). inputs. Linear modules have separate protection for AC and DC mode, this
significantly increases the safety level of switching the emergency mode
in the building. In the emergency mode, the system works in IT network
(isolated system).
System LPS
72
systems
The most important parameters:
• LCD display with easy-to-use menu • Possibility to record the back-up of the system on the SD card
• Automatic test performing • Night mode operation
• Automatic detection and adding luminaires to the system • Possibility to control luminaires and functions of the system through the
• Monitoring of each luminaire 24V and 230V internal and external connectors
• Monitoring of each circuit • Possibility to monitor power in the distribution boards and in the
• Programming and configuration of the luminaires directly from the separate lighting circuits
central unit • USB slot
• Communication with luminaires through the power cable • RJ45 connector for direct communication with any computer via
• SMART technology – any mode of operation of the luminaire Ethernet
• The linear modules are secured for the AC and DC mode separatelly • Preview of the system via any web browser
• SD card slot and card itself allow to save the periodic test results, event • Management and visualization of the system by using dedicated
log and system configuration software SMART VISIO
• Supply of the fixtures of total capacity 1500W for time 1h or 500W for 3h
LON/LAN
LON/LAN
LON/LAN
SUPPLY
73
systems
Central Battery system CBS
The CBS central battery system is state-of-the-art, reliable and easy- the periodic test results, event log and system configuration, in accordance
to-operate central battery system constructed in accordance with the with EN 50172. The event log can be printed out of the SD card on any
requirements of VDE 0108 as well as EN 50171 and EN 50172 standards. PC without any additional software. Besides, all the settings are stored in
Due to the possibility of using sub-modules it is dedicated to medium and non-volatile memory and will not be lost even during the complete power
large buildings and was designed in SMART technology. supply and battery failure. The charger module ensures battery charging
based on UI characteristics with temperature compensation according
The system monitors each output circuit individually and with the use to EN 50171. The charger is equipped with internal active PFC module
of address modules – each luminaire. The system allows any configuration which provides a power factor close to 1. Linear modules have separate
of mode both of the circuit and the luminaire. Using the driver one can protection for AC and DC mode, significantly increasing the safety level
programme the mode of the address module without interfering into the while switching on emergency lighting in the building. In DC mode the
luminaire and without any specialized service software. The SD card slot system works in IT network layout (isolated system).
used in the system allows to perform a backup of the system and to save
74
systems
The most important parameters:
CB/02 CB/02 (n=MAX 20 OR 6A) PBS/01/n (n=MAX 20) PBS/01/03 PBS/01/02 PBS/01/01
CB/01/01 CB/01/02 CB/01/03 CB/01/n (n=MAX 20) PBS/02/n (n=MAX 20) PBS/02/03 PBS/02/02 PBS/02/01
CB/01 monitoring of luminaires
(combined mode)
lon
AC - 230V
mains 230V
Monitoring
L1, L2, L3 230V
cbs Monitoring
L1, L2, L3 230V
Remote control panel smart visio Monitoring
L1, L2, L3 230V
75
systems
THE SMART VISIO PLATFORM
SMART VISIO application is an advanced supervising and managing implemented in most of the buildings. Due to the low installation costs,
software created by AWEX for the latest emergency lighting systems. the possibility of full visualization and minimum time necessary for the
Regardless of the choice of the system (FZLV, LPS, CBS, RUBIC UNA) SMART daily inspection of emergency lighting, SMART VISIO is recommended for
VISIO allows you to connect, group and visualize each of them at the same shopping malls, medium and large office buildings, hospitals, stadiums,
time and in any configuration, from one place. By using a common LAN airports factories and other buildings.
standard to communicate with the systems, the software is easy to be
Properties:
PC
LAN LAN
max. 100m max. 100m
ROUTER
76
systems
In the tree of the system, one of the systems can be selected and its status
will be shown on the panel. If the System is chosen, the status of all the
central units will be seen (icons change color the same way as on the plan
of the building). To change the current settings, use “Settings” tab.
RUBIC panel allows you to see the status of Rubic UNA or Rubic UNA MINI
central unit, as well as conversion kits and luminaires connected to it, to
see the results of tests, reports and configuration of the central unit. The
diagram displays the software version, serial number, status of inputs,
outputs, errors, lock, night work, power status, charger status, battery
status. Icons indicate the status of groups and sub-modules.
FZLV panel allows observation of the FZLV central unit and the luminaires
connected to it, viewing test results, reports, graphs and configuration of
the central unit. The diagram shows the hardware and software version,
serial number, status of inputs, outputs, errors, lock, night work, total
status of the central unit, power status, charger status, battery status,
circuit status.
CBS panel allows observation of status of the central battery, control unit,
charger, sensor modules, linear modules and luminaires, view test results,
reports. The diagram shows a view of the central battery cabinet. Modules
inside the cabinet can be moved by dragging the module with a mouse,
left button pressed. The control module is shown as CM (Control Module),
charger is shown as CH (Charger). The status of the groups (G1 - G255) is
displayed in the table named Steering Groups. The list displays the status
of the linear modules LM (Linear Module) and sensor modules SM (Sensor
Module).
77
additional components
TECHNICAL SPECIFICATION:
Power supply: 230 VAC/50 Hz
Insulation class: I
Minimal ambient temperature: -25°C
Minimal battery temperature: +6°C
Heater initiation temperature: <10°C
4
2
L
N
PE
Legend:
1. Thermostat NO – closing temperature 10°C ±5°C – assembled inside the fixture
2. Thermostat NC – opening temperature 60°C ± 5°C – assembled on the battery
3. Self-regulated heating wire
4. Battery pack
ORDER CODES
CODE BATTERY CAPACITY BATTERY TYPE CODE BATTERY CAPACITY BATTERY TYPE
HTR-25/3.6-1000-CD 3.6V 1000mAh Ni-Cd HTR-25/3.6-1000-MH 3.6V 1000mAh Ni-MH
HTR-25/3.6-1500-CD 3.6V 1500mAh Ni-Cd HTR-25/3.6-1500-MH 3.6V 1500mAh Ni-MH
HTR-25/3.6-2500-CD 3.6V 2500mAh Ni-Cd HTR-25/3.6-2500-MH 3.6V 2500mAh Ni-MH
HTR-25/3.6-4000-CD 3.6V 4000mAh Ni-Cd HTR-25/3.6-4000-MH 3.6V 4000mAh Ni-MH
HTR-25/4.8-1500-CD 4.8V 1500mAh Ni-Cd HTR-25/4.8-1500-MH 4.8V 1500mAh Ni-MH
HTR-25/4.8-2500-CD 4.8V 2500mAh Ni-Cd HTR-25/4.8-2500-MH 4.8V 2500mAh Ni-MH
HTR-25/4.8-4000-CD 4.8V 4000mAh Ni-Cd HTR-25/4.8-4000-MH 4.8V 4000mAh Ni-MH
HTR-25/6.0-1500-CD 6.0V 1500mAh Ni-Cd HTR-25/6.0-1500-MH 6.0V 1500mAh Ni-MH
HTR-25/6.0-2500-CD 6.0V 2500mAh Ni-Cd HTR-25/6.0-2500-MH 6.0V 2500mAh Ni-MH
HTR-25/6.0-4000-CD 6.0V 4000mAh Ni-Cd HTR-25/6.0-4000-MH 6.0V 4000mAh Ni-MH
HTR 25 heating system type is designed for installation in luminaires with a degree of IP65 or higher.
HTR25 heating system type is designed for installation in luminaires with a degree of IP65 or higher.
80
additional components
Accessories
300 30
128
CEILING BRACKET
HELIOS
CODE: 1902
300 30
115
WALL BRACKET
HELIOS
CODE: 1901
128
435
CEILING BRACKET WITH PIPE
HELIOS
CODE: 2944
300
348
WALL BRACKET
INFINITY AS, INFINITY AC, ESCAPE
CODE: 1011
45
110
325
WALL BRACKET
TWINS
CODE: 1009
120
SUSPENSION ROPES
120
135
120
EXTENSION BOX
LOVATO N
CODE: WWT 1000064
120
81
additional components
BATTERIES
DIMENSIONS [mm]
CODE CAPACITY [mAh] VOLTAGE [V] WEIGHT [Kg]
AxBxCxDxExF
1000 153x179x18x15x14x4 0,076
1500 136x162x25x22x18x4 0,14
Ni-Cd 3.6
2500 152x178x30x26x20x4 0,21
4000 189x210x30x33x25x4 0,352
1500 175x202x25x22x18x4 0,184
Ni-Cd 2500 4.8 202x228x30x26x20x4 0,288
4000 245x270x36x33x25x4 0,452
1500 218x244x25x22x18x4 0,228
Ni-Cd 2500 6.0 248x275x30x26x20x4 0,354
4000 303x329x36x33x25x4 0,574
1500 153x179x18x15x14x4 0,088
Ni-MH 2500 3.6 136x162x25xx22x18x4 0,172
4000 152x179x30x26x20x4 0,26
1500 202x228x18x15x14x4 0,114
Ni-MH 2500 4.8 175x202x25x22x18x4 0,22
4000 202x228x30x26x20x4 0,338
1500 251x276x18x15x14x4 0,14
Ni-MH 2500 6.0 220x246x26x23x18x4 0,268
4000 251x276x30x26x20x4 0,398
C
E
F
A
B
82
additional components
pictograms
22 23 24
25 26 27
28 29
61
designed for TG, TL, TGS, TSL H, HE, HEL, HD, HDE, HDL, HDEL TP, TPL, HP, HPL, E, EL, TW, PL, IF, SK8 Q
Legend:
xx - number of pictogram (picture above)
83
Information for readers
Used symbols
The product meets the requirements in accordance with Light source type - LED
the European Directive LED
220-240V The permissible range of AC input voltage Light source type - fluorescent lamp T5
AC T5
50-60Hz G5
Safety extra low voltage SELV Mounting of emergency escape lighting fittings - surface / ceiling
24V
DC
*see pictogram
The pictures and the parameters of the products contained in this catalogue shall be considered only a commercial information and do not constitute
an offer within the meaning of the law.
Some parameters of the delivered products may differ from the parameters of the products in this catalogue. Appearance of some products may differ
slightly from pictures and drawings represented in this catalogue. AWEX company reserves the right to withdraw products from catalogue or change
their parameters.
84
notes
P.P.H.U. AWEX Rafał Stanuch
Masłomiąca, ul. Długa 39
32-091 Michałowice, Poland
tel.: (+48) 12 681 55 00, fax: (+48) 12 681 55 26
e-mail: [email protected]
www.awex.eu