100% found this document useful (1 vote)
2K views

Defining Error Codes LG

This document defines common error codes and test modes for LG wall-mounted non-inverter air conditioning systems. It lists 10 error codes indicated by the number of blinks of the indoor unit LED, including codes for thermistor issues, communication failures, and memory errors. It also describes how to initiate the outdoor unit test mode using the PCB button to test components and check for system errors. LED colors on the outdoor PCB indicate which component is being tested in each sequence. Refer to service manuals for troubleshooting specific error codes.

Uploaded by

novy
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views

Defining Error Codes LG

This document defines common error codes and test modes for LG wall-mounted non-inverter air conditioning systems. It lists 10 error codes indicated by the number of blinks of the indoor unit LED, including codes for thermistor issues, communication failures, and memory errors. It also describes how to initiate the outdoor unit test mode using the PCB button to test components and check for system errors. LED colors on the outdoor PCB indicate which component is being tested in each sequence. Refer to service manuals for troubleshooting specific error codes.

Uploaded by

novy
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DEFINING COMMON ERROR CODES

Standard Wall-Mounted Non-Inverter Single Zone Systems


LS093HE/CE Systems (LSN093HE/CE Indoor Units / LSU093HE/CE Outdoor Units)
LS122HE/CE Systems (LSN122HE/CE Indoor Units / LSU122HE/CE Outdoor Units)

LSN093HE/CE and LSN122HE/CE Indoor Units LED

Location of light-emitting diode (LED) display

Defining Commom Error Codes


No. of Times Indoor Unit
Error Code Description
LED Blinks
1 Indoor unit thermistor is disconnected or is shorted out. 1X
2 Outdoor unit thermistor is disconnected or is shorted out. 2X
5 Communication failure from indoor unit to outdoor unit. 5X
9 Indoor unit electrically erasable programmable read-only memory (EEPROM) error. 9X
10 Indoor unit fan has locked up (fan motor operation failure). 10X

LSU093HE/CE and LSU122HE/CE Outdoor Units Location of PCB LED: To access, remove outdoor unit
cover, and then remove lid to PCB box.

LED1 (Green)
Random blinking of LED1 (Green) indicates normal
communication between the outdoor unit PCB and the
indoor unit PCB.

1
DEFINING COMMON ERROR CODES
Standard Wall-Mounted Non-Inverter Single Zone Systems
LS093HE/CE Systems (LSN093HE/CE Indoor Units / LSU093HE/CE Outdoor Units)
LS122HE/CE Systems (LSN122HE/CE Indoor Units / LSU122HE/CE Outdoor Units)
Test Mode Operation
LG non-inverter systems include a test mode that can be initiated by pressing the test key (button) on the outdoor unit PCB. Test mode can be
used to verify individual component operation at any time. See table below for list of outdoor unit components tested. If system is functioning
properly, the components will operate normally. If there are system errors, the components will not function.

Sequence of Test Steps


Outdoor Unit Component Tested Indoor Unit Operation
(Consecutive Button Pushes)
First Initializes test button mode. Units do not operate.
Second Compressor and condenser fan. Runs in Super High Fan Speed mode.
Reversing valve (verify using line voltage at connector terminal).
Third Runs in High Fan Speed mode.
Red LED on PCB blinks.
Condenser fan, reversing valve, and crankcase heater.
Fourth Run in Medium Fan Speed mode.
Green LED on PCB blinks.

Defining Commom Error Codes


Fifth Fan (9,000 and 12,000 Btu/h capacity units only). Runs in Low Fan Speed mode.
Fan (9,000 and 12,000 Btu/h capacity units only).
Sixth Runs in Super High Fan Speed mode.
Red and green LEDs on PCB blink.
Seventh Resets for normal operation. Units will start after three (3) minutes.

Note:
• Resetting the power will terminate test button mode.
• Test button mode will self-terminate after 17 minutes of inactivity. System will then resume normal operation.

LED1 (Green) LED2 (Red)

Location of PCB LED


and test key: To access,
remove outdoor unit
cover, and then remove lid
to PCB box.

Test Key (Button)

Refer to Service Manuals posted on www.lg-dfs.com to troubleshoot individual error codes.


LG Electronics U.S.A. – Commercial Air Conditioning
For continual product development, LG reserves the right to change specifications without notice.
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp.
DFS-TP-AA-001-US 012J10
2

You might also like