0% found this document useful (0 votes)
119 views

LP12 50

This document provides specifications for an LP12-50 12V lead-acid battery with a nominal capacity of 50 amp-hours. The battery dimensions are 257mm x 132mm x 200mm and it weighs approximately 15.7 kg. It has a rated capacity of 50.0 amp-hours when discharged over 10 hours at 5.00 amps and 25°C. The battery is suitable for applications requiring uninterrupted backup power such as UPS systems, emergency lighting, and alarm systems.

Uploaded by

Ja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views

LP12 50

This document provides specifications for an LP12-50 12V lead-acid battery with a nominal capacity of 50 amp-hours. The battery dimensions are 257mm x 132mm x 200mm and it weighs approximately 15.7 kg. It has a rated capacity of 50.0 amp-hours when discharged over 10 hours at 5.00 amps and 25°C. The battery is suitable for applications requiring uninterrupted backup power such as UPS systems, emergency lighting, and alarm systems.

Uploaded by

Ja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

LP SERIES-General Purpose

LP12-50 (12V50AH)
Specification
Nominal Voltage 12V
Nominal Capacity(10HR) 50.0AH
Length 257±3mm (10.1 inches)
Width 132±2mm (5.19 inches)
Dimensions Mai nten anc LP12-5
0(12V50AH
Container Height 200±3mm (7.87 inches) Warni ng:
Risk of fire,
heat above
e-fr ee Sea
explo sion,
the 50 OC,
led Lea d-a
or burns .
Do
cid Bat tery
or incine rate. not disass emble ,
)

Total Height (with Terminal) 200±3mm (7.87 inches) R


MH26 866

LEOCH BATTE
RY
CO.,LTD.
MADE IN CHINA Pb.
Non-s
BATTERY MUSTpillable

Approx Weight Approx 15.7 kg (34.6lbs) BE RECYCLED

Terminal T6
Container Material ABS
52.0 AH/2.60A (20hr ,1.80V/cell,250C/770F)
50.0 AH/5.00A (10hr,1.80V/cell,250C/770F) Applications
Rated Capacity 43.1 AH/8.62A (5hr,1.75V/cell,250C/770F)
39.0 AH/13.0A (3hr,1.75V/cell,250C/770F) All purpose
30.5 AH/30.5A (1hr,1.60V/cell,250C/770F) Uninterruptable Power Supply (UPS)
Max. Discharge Current 600A (5s) Electric Power System (EPS)
Internal Resistance Approx 8mΩ Emergency backup power supply
0
Discharge : -15~50 C (5~122 F) 0
Emergency light
Operating Temp.Range Charge : 0~400C (32~1040F) Railway signal
Storage : -15~400C (5~1040F)
Aircraft signal
Nominal Operating Temp. Range 25±30C (77±50F ) Alarm and security system
Initial Charging Current less than 15.0A.Voltage Electronic apparatus and equipment
Cycle Use
14.4V~15.0V at 250 C(770 F)Temp. Coefficient -30mV/0C
Communication power supply
No limit on Initial Charging Current Voltage DC power supply
Standby Use
13.5V~13.8V at 250 C(770 F)Temp. Coefficient -20mV/0C Auto control system
40o C (104o F) 103%
Capacity affected by
25o C ( 77o F) 100%
Temperature o o VdS
0 C ( 32 F) 86%
Leoch LP series batteries may be stored for up to 6 months
Self Discharge at 250 C(770F) and then a freshening charge is required. t est ed
For higher temperatures the time interval will be shorter. 9 Germany

Constant Current Discharge (Amperes) at 25 0C (77 0F )


F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 85.6 67.3 57.2 47.9 38.0 28.8 23.6 15.0 11.9 9.70 7.82 6.81 5.53 4.72 2.58
1.80V/cell 114.9 86.0 69.1 56.6 44.9 33.5 26.4 16.4 12.8 10.4 8.40 7.30 5.86 5.00 2.60
1.75V/cell 129.5 94.5 75.5 60.9 46.6 34.7 27.6 17.0 13.0 10.6 8.60 7.50 5.96 5.05 2.63
1.70V/cell 142.6 103.0 80.6 64.0 48.5 36.1 28.5 17.7 13.4 10.9 8.83 7.66 6.05 5.10 2.68
1.65V/cell 157.3 111.1 85.7 67.9 51.2 37.0 29.5 18.2 13.9 11.2 9.08 7.83 6.14 5.21 2.71
1.60V/cell 173.5 120.6 91.7 72.4 54.0 38.6 30.5 18.8 14.4 11.6 9.38 8.00 6.20 5.26 2.73

Constant Power Discharge (Watts/cell) at 25 0C (77 0F )


F.V/Time 5min 10min 15min 20min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h
1.85V/cell 156.5 124.3 106.8 90.2 72.5 55.3 45.5 29.2 23.1 19.0 15.3 13.4 10.9 9.34 5.10
1.80V/cell 207.8 156.9 127.3 105.1 84.2 63.9 50.7 31.6 24.8 20.1 16.4 14.3 11.5 9.88 5.14
1.75V/cell 229.3 169.7 137.3 111.9 86.7 65.6 52.8 32.7 25.1 20.5 16.7 14.6 11.7 9.97 5.19
1.70V/cell 245.5 180.7 144.5 116.8 89.8 68.0 54.2 33.9 25.8 21.0 17.1 14.9 11.9 10.1 5.28
1.65V/cell 266.9 193.3 152.5 123.1 93.9 69.1 55.7 34.6 26.7 21.7 17.6 15.2 12.0 10.2 5.34
1.60V/cell 287.5 205.0 160.4 129.7 98.5 71.6 57.3 35.6 27.4 22.3 18.1 15.5 12.1 10.3 5.37
Specifications subject to change without notice.

1
Dimensions

T6 Terminal
Unit: mm
φ16
M6

132±2
200±2

114
190±2
6

2-M6

216
257±3

Discharge Characteristics Float Charging Characteristics


12V
Battery
(V) Temperature:25 0 C(77 0 F) Charge Charging Charging
Volume Current Voltage
13.0 0
(V) 0.10CA-2.25V/cell temperature25 C
% (XCA)

12.0
0.25
120 15.0
110 Charged Volume
Terminal Voltage(V)

11.0
0.20
100
0.1C 0.0525C 14.0
0.205C 90 Charge Voltage
10.0 0.4C 80 (Constant 2.25v/cell)
0.15
70 13.0
1C 0.6C
9.0 60
After 50% Discharge
50 0.10
12.0
40 After 100% Discharge
8.0 30
2C 0.05 11.0
20
10 Charging Current
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20
0 0
Min H
0 4 8 12 16 20 24 28 32 36 40
Discharge Time Charging Time(hours)

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life

120 10
0.1CA 8
100 0.17CA 6
5
Capacity(%)

Float Life(year)

0.25CA Charging voltage :


4
80 2.25V/cell
3

60 2

40
1

20
0.5
20 30 40 50 0
O
C
-20 -10 0 10 20 30 40 50 60 68 86 104 122 F
0 Battery temperature
Temperature( C)

Cycle Life in Relation to Depth of Discharge Self Discharge Characteristics


Testing condition
100
Discharging:current 0.17C (FV 1.7V/cell);
Charging:current 0.25C max, voltage 2.45V/cell; A
Remaining Capacity(%)

100C
Charging volume:125% of discharged capacity. 80
Ambient teperature:25±5 C 0 250C
120 60
B

400C 300C
100 40

80 C
20
Capcity(%)

60
100% 50% 30% 0
DOD DOD DOD 2 4 6 8 10 12
40
Ambient Termperature: Storage Time(Months)
25oC (77oF)
20 No supplementary charge required
A (Carry out supplementary charge before use if 100% capacity is required.)
0 Supplementary charge required before use.Optional charging way as below:
0 200 400 600 800 1000 1200 1.Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell.
B 2.Charged for above 20hours at limted current 0.25CA and constant volatge 2.45V/cell.
Number of Cycles 3.Charged for 8~10hours at limted current 0.05CA .

Supplementary charge may often fail to recover the capacity.


C The battery should never be left standing till this is reached.

Sales Office
China sales office: HongKong sales office: Singapore sales office: North America sales office: Europe sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd., Workshop C, 33/F, TML Tower, Add: No. 1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Court. Waterwells
Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2-2AQ,
Tel: +86-755-86036060 (100 lines) New Territories, Hong Kong Tel: +65 68636078 Tel: 949-588-5853 UK United Kingdom
Fax: +86-755-26067269 Tel: +852 35786666 Fax: +65 68636079 Fax: 949-588-5966 Tel: +44(0) 1452 729428 / 1452 729696
E-mail:[email protected] Fax: +852 21170016 Email [email protected] E-mail: [email protected] Fax: +44 (0)1452-690125
Http://www.leoch.com E-mail: [email protected] Http://www.leoch.com Http://www.leoch.com E-mail: [email protected]

Publication No.:LB-LP-7-17
2

You might also like