Wlink R520 Cellular Router User Manual
Wlink R520 Cellular Router User Manual
V3.5
http://www.wlink-tech.com
Jan, 2018
Industrial Cellular Router User Manual
Copyright © Shenzhen WLINK Technology Company Limited 2012 ~ 2018
Without our written approval, Anyone can’t extract, copy whole or part of content of this file and
can’t spread out in any format.
Caution
Due to product updates or functional upgrading, we may renew the content of this file, and this
file only for reference. All statement, information, suggestion .etc in this file does not compose
any form of guarantee and we WLINK reserves the right of final explanation.
Web: http://www.wlink-tech.com
Tel: 86-755-86089513
Fax: 86-755-26059261
www.wlink-tech.com 1
Industrial Cellular Router User Manual
Contents
1 Product Introduction.................................................................................................................... 4
2.1 Panel:................................................................................................................................. 9
www.wlink-tech.com 2
Industrial Cellular Router User Manual
3.10 Appendix (For Dual SIM, GPS, Captive Portal &OpenVPN only) ........................ 56
www.wlink-tech.com 3
Industrial Cellular Router User Manual
1 Product Introduction
www.wlink-tech.com 4
Industrial Cellular Router User Manual
Table 1-1 Router partial model table
www.wlink-tech.com 5
Industrial Cellular Router User Manual
Appearance
Product Single port router Single port Wi-Fi(GPS)router Multi-port Wi-Fi router multi-port double-link router
category
For example, in economic area, R520 Series Router connect server by IPSec & GRE to
ensure data security, tiny design makes it could installed into ATM machine. All these
technology ensured safe and reliable data transmission, and minimize the probability of
network disconnection, and maximize the usability of economic business like ATM, POS .etc.
www.wlink-tech.com 6
Industrial Cellular Router User Manual
1.5 Features
Various cellular module optional, LTE/HSPA+/EVDO/CDMA2000 optional
Support IEEE802.11b/g/n Wi-Fi AP function, extended support to Wi-Fi terminal,
WDS bridging, support WEP, WPA/WPA2 Personal/Enterprise, TKIP/AES, etc.,
Authenticated encryption mode
Support virtual data and private network(APN/VPDN)
Optional support RS-232/RS-485 interface data transparent transmission and
protocol conversion
Support on-demand dialing, include timing on/off-line, voice or SMS control
on/off-line, data trigger online or link idle offline
Support TCP/IP protocol stack, support Telnet, HTTP, SNMP, PPP, PPPoE, etc.,
network protocol
Support VPN Client(PPTP, L2TP),optional support Open VPN, IPSec, HTTPs,
SSH, etc. advanced VPN function
Provide friendly user interface, use normal web internet explorer to easily
configure and manage, long-distance configure Telnet/SSH + CLI
Optional IPv6 protocol stack
www.wlink-tech.com 7
Industrial Cellular Router User Manual
Optional support M2M terminal management platform
WDT watchdog design, keep system stable
Customization as customer’s demand
www.wlink-tech.com 8
Industrial Cellular Router User Manual
2 Hardware Installation
This chapter is mainly for installation introduction, there would be some difference
between the scheme and real object. But the difference doesn’t have any influence to
products performance.
2.1 Panel:
Table 2-1 WL-R520 Structure
WLINK Tech. WL-R520 series
Front
Rear
There are some different for Antenna interface and indicator light for the
expanded Wi-Fi, GPS series.
www.wlink-tech.com 9
Industrial Cellular Router User Manual
There are some difference among the LED indicator of expanded Wi-Fi, GPS
function and single module/double SIM, double module/double SIM series
www.wlink-tech.com 10
Industrial Cellular Router User Manual
products.
2.3 Dimension
www.wlink-tech.com 11
Industrial Cellular Router User Manual
2.4.5 Review
After insert the SIM/UIM card, connect Ethernet cable and necessary antenna, connect
power cable.
Please connect the antenna before connect the power cable, otherwise the signal
maybe poor because of impedance mismatching.
Notice:
Step 1 Check antenna connection.
Step 2 Check SIM/UIM card, confirm SIM/UIM card is available.
----END
www.wlink-tech.com 12
Industrial Cellular Router User Manual
3 Router Configuration
This Chapter introduces the parameter configuration of the router, the router can be
configured via web internet explorer, Firefox, or chrome. Here we take GUIs 7 system and
Internet Explorer 9.0 as sample.
Step 1 Click “start > control panel”, find “Network Connections” icon and double click it to
enter, select “Local Area Connection” corresponding to the network card on this
page. Refer to the figure below.
www.wlink-tech.com 13
Industrial Cellular Router User Manual
User should use the default user name and password when log in for the first time
Different software version have different web configuration interface, below take R520
2.6.0.1 version as example.
After visit the WEB interface, you can check the current status of Router, or modify router
configuration via web interface, below is the introduction for the common setting.
www.wlink-tech.com 14
Industrial Cellular Router User Manual
www.wlink-tech.com 15
Industrial Cellular Router User Manual
Parameter Instruction
Dial Mode ECM/PPP optional. Suggest ECM for 4G router
Bridge WAN to Configure WAN port as LAN port
LAN
Step 2 After setting, please click “save” to finish, the device will reboot.
----End
www.wlink-tech.com 16
Industrial Cellular Router User Manual
Parameter Instruction
Pin Code Some SIM cards are locked with a Personal Identification
Number (PIN) code to prevent misuse if they are lost or stolen.
Operator Lock Lock router for a specified operator via MCC/MNC code.
Connect Mode Auto.Router will automatically connect 3G/4G network and
keep 4G in prior.
LTE. Router will connect 4G only.
3G. Router will connect 3G only.
APN APN, provided by local ISP, usually CDMA/EVDO network do
not need this parameter.
User SIM card user name is provided by ISP
【ICMP Check】
Enable ICMP, Router will automatically check whether the defined IP address is
reachable per 60s. If the IP address is unreachable and ICMP check is timeout at
the first time, it will check 2 times every 3 seconds. If the third time is still failed, the
router will redial.
The ICMP Check IP is a public IP or company server IP address.
【Rx】Router will check the 3G/LTE cellular receiver traffic. If no receiver traffic within
the defined check interval, the router will implement the specified action reconnect
or reboot.
www.wlink-tech.com 17
Industrial Cellular Router User Manual
www.wlink-tech.com 18
Industrial Cellular Router User Manual
Step 2 After setting, please click “save” to finish, the device will reboot.
----End
www.wlink-tech.com 19
Industrial Cellular Router User Manual
www.wlink-tech.com 20
Industrial Cellular Router User Manual
www.wlink-tech.com 21
Industrial Cellular Router User Manual
www.wlink-tech.com 22
Industrial Cellular Router User Manual
www.wlink-tech.com 23
Industrial Cellular Router User Manual
----End
www.wlink-tech.com 24
Industrial Cellular Router User Manual
----End
www.wlink-tech.com 25
Industrial Cellular Router User Manual
Figure 3-10 Port Forwarding GUI
www.wlink-tech.com 26
Industrial Cellular Router User Manual
Figure 3-11 Port Forwarding GUI
www.wlink-tech.com 27
Industrial Cellular Router User Manual
parameter Instruction
Leave Remote
Access
www.wlink-tech.com 28
Industrial Cellular Router User Manual
www.wlink-tech.com 29
Industrial Cellular Router User Manual
www.wlink-tech.com 30
Industrial Cellular Router User Manual
www.wlink-tech.com 31
Industrial Cellular Router User Manual
www.wlink-tech.com 32
Industrial Cellular Router User Manual
Figure 3-18 VRRP Setting GUI
Step 2 Please click ”save” to finish.
----End
3.5 Firewall
3.5.1 IP/URL Filtering
Step 1 Please click “Firewall> IP/URL Filtering” to check or modify the relevant
parameter.
www.wlink-tech.com 33
Industrial Cellular Router User Manual
www.wlink-tech.com 34
Industrial Cellular Router User Manual
www.wlink-tech.com 35
Industrial Cellular Router User Manual
Figure 3-21 GRE Setting GUI
www.wlink-tech.com 36
Industrial Cellular Router User Manual
Parameter Instruction
Start with WAN Enable the Openvpn feature for 4G/3G/WAN port.
Interface Type Tap and Tun type are optional.
Tap is for bridge mode and Tunnel is for routing mode.
Protocol UDP and TCP optional.
Server Address The Openvpn server public IP address and port.
Firewall Auto, External only and Custom are optional
Parameter Instruction
Poll Interval Openvpn client check router’s status as interval time.
Redirect Internet Configure Openvpn as default routing.
Traffic
www.wlink-tech.com 37
Industrial Cellular Router User Manual
Parameter Instruction
Access DNS As the configuration requested.
Encryption As the configuration requested.
Compression As the configuration requested.
Parameter Instruction
Certificate Authority Keep certificate as the same as server
www.wlink-tech.com 38
Industrial Cellular Router User Manual
Parameter Instruction
Ceneral Statistics Check Openvpn status and data statistics.
www.wlink-tech.com 39
Industrial Cellular Router User Manual
Table 3-18 “PPTP/L2TP Basic” Instruction
parameter Instruction
On VPN enable
Protocol VPN Mode for PPTP and L2TP
Name VPN Tunnel name
Server Address VPN Server IP address.
User name As the configuration requested.
Password As the configuration requested.
www.wlink-tech.com 40
Industrial Cellular Router User Manual
www.wlink-tech.com 41
Industrial Cellular Router User Manual
www.wlink-tech.com 42
Industrial Cellular Router User Manual
www.wlink-tech.com 43
Industrial Cellular Router User Manual
----End
www.wlink-tech.com 44
Industrial Cellular Router User Manual
www.wlink-tech.com 45
Industrial Cellular Router User Manual
If the device is online but time update is fail, please try other NTP Time Server.
www.wlink-tech.com 46
Industrial Cellular Router User Manual
www.wlink-tech.com 47
Industrial Cellular Router User Manual
www.wlink-tech.com 48
Industrial Cellular Router User Manual
www.wlink-tech.com 49
Industrial Cellular Router User Manual
Parameter Instruction
M2M Enable Enable/Disable M2M feature in router.
Device ID Identify router in M2M Platform. Max length 24byts and Min
length 7bytes visible characters.
M2M Configure M2M platform IP and port. The router will log in
Server/Port M2M platform and establish a connection between router
and M2M platform. The connection protocol is UDP.
Step 2 After setting the backup and restore configuration. The system will reboot
automatically.
----End
www.wlink-tech.com 50
Industrial Cellular Router User Manual
www.wlink-tech.com 51
Industrial Cellular Router User Manual
www.wlink-tech.com 52
Industrial Cellular Router User Manual
www.wlink-tech.com 53
Industrial Cellular Router User Manual
www.wlink-tech.com 54
Industrial Cellular Router User Manual
Figure 3-34 Trace GUI
Step 2 After configure, please click “Save” to finish.
----End
www.wlink-tech.com 55
Industrial Cellular Router User Manual
LAN IP 192.168.1.1
LAN Subnet Mask 255.255.255.0
DHCP server Enable
User Name admin
Password admin
After reboot, the previous configuration would be deleted and restore to factory
settings.
www.wlink-tech.com 56
Industrial Cellular Router User Manual
【ICMP Check】
Enable ICMP, Router will automatically check whether the defined IP address is
reachable per 60s. If the IP address is unreachable and ICMP check is timeout at
the first time, it will check 2 time as 3s interval. If the third time is still failed, the
router will implement fail action as you configured..
The Check IP is an public IP or company server IP address.
www.wlink-tech.com 57
Industrial Cellular Router User Manual
【Rx】Router will check the 3G/LTE cellular receiver traffic. If no receiver traffic within
the defined check interval, the router will implement the specified action Reconnect
or reboot.
【SIM Mode】
【Fail Over】SIM card mutual backup. Once SIM card is failed, it will switch to the
SIM2 and work on SIM2. Once SIM2 is failed, it will switch back to SIM1.
【Backup】SIM1 is the primary SIM. Once SIM1 is failed, it will switch to SIM2 and
work on SIM2 within the defined time. Once the time is over, it will switch back to
SIM1.
www.wlink-tech.com 58
Industrial Cellular Router User Manual
2. Example
0001_R081850ac,150904,043215.0,06,2234.248130,N,11356.626179,E,0.0,91.5,1,1.2,9
www.wlink-tech.com 59
Industrial Cellular Router User Manual
7.5
www.wlink-tech.com 60
Industrial Cellular Router User Manual
Parameter Instruction
Web Host Configure domain name for the captive portal access. For example,
Configure as wlink.tech.com, we might directly access to captive
portal page in the website as wlink.tech.com
Logged Timeout Maximum time user has connectivity. User need to re-login Captive
Portal page after defined time.
Idle Timeout Maximum time user has connectivity if no network activity from Wi-Fi
User.If User need to re-login Captive page to surf internet.
Ignore LAN If enabled, LAN devices will bypass the Captive Portal page.
Redirecting Router will redirect to the defined link after accepting the terms and
conditions on the Captive Portal page.
www.wlink-tech.com 61
Industrial Cellular Router User Manual
Parameter Instruction
Download QoS Enable to apply the Download and Upload per user limits.
Each Ad file just supports 3 Ad portal images. Picture format should be .png and image
size is less than 100Kbytes and resolution is 800*600. Picture name is 0001_portal.png,
0002_portal.png and 0003_portal.png. Furthermore, please keep image names the same
between portal file and splash.html.
www.wlink-tech.com 62
Industrial Cellular Router User Manual
www.wlink-tech.com 63
Industrial Cellular Router User Manual
---End
www.wlink-tech.com 64
Industrial Cellular Router User Manual
2)Modify portal file storage path
1) Network topology
www.wlink-tech.com 65
Industrial Cellular Router User Manual
www.wlink-tech.com 66
Industrial Cellular Router User Manual
www.wlink-tech.com 67
Industrial Cellular Router User Manual
www.wlink-tech.com 68
Industrial Cellular Router User Manual
www.wlink-tech.com 69