DC Motors & Controls

HVAC Motors
Subfractional Permanent 1/50 thru 1/4 Hp
Magnet DC Motor - TENV,
Applications: General purpose including conveyors, material
Rigid Base handling equipment and packaging machinery.

Farm Duty
Motors
Features: High quality ball bearing motors with precision machined
die cast aluminum or steel housings. Dynamically balanced for
smooth, vibration-free operation.

Definite Purpose
Input Output Voltage Full Load Ap’x.
Catalog List Mult.

Motors
Motor Base Direct Current Amperage Gear Style Shpg. Notes (a)
Number Price Sym.
Hp Speed Armature Armature Wgt.
1/50 1800 90 0.3 AP231001 244 DS 2308P 4 20,60
1/25 1725 90 0.5 AP232001 268 DS 2314P 5 20,60
90 0.8 AP233001 288 DS 2318P 6 20,60
1/15 1800
180 0.4 AP233021 288 DS 2318P 6 20,60

Brake Motors
90 1.3 AP7401 403 DS 2424P 10 20,60
1/8 1725
180 0.7 AP7402 403 DS 2424P 10 20,60
90 2.5 AP7421 403 DS 2424P 10 20,60
1/4 3450
180 1.3 AP7422 403 DS 2424P 11 20,60
NOTE: Supplied with type SJO, three foot 18/3 AWG grounded cord. (a) See notes on inside back flap and pages 5-6.

SCR Drive Permanent

200 & 575 Volt


1/4 thru 5 Hp NEMA 56C thru 1810ATC

Motors
Magnet Motor -
TENV and TEFC, C-Face Applications: Conveyors, mixers, packaging machinery.
with Base Features: NEMA C-face with removable base. Tach adaptable. Class
F insulation, double sealed ball bearings. 20:1 constant torque speed
range. UL and CSA recognized. 1/4 - 1/2 Hp motors are TENV, all others

IEC Frame
Motors
are TEFC. No dual mounting base holes on 1/4 - 1/2 Hp.

Voltage Full Load Ap’x.

50 Hertz
Base NEMA Catalog List Mult. Reliance

Motors
Hp D.C. Amperage Enclosure Shpg. Notes (a)
Speed Frame Number Price Sym. M/N
Arm. Arm. Wgt.

90 2.5 TENV CDP3310 584 K 24 20,60 T56S1001


1/4 1750 56C
180 1.25 TENV CDP3306 584 K 24 20,60
90 3.2 TENV CDP3320 617 K 27 20,60 T56S1003

Motors & Controls


1/3 1750 56C

Inverter/Vector
180 1.6 TENV CDP3316 617 K 27 20,60
90 4.8 TENV CDP3330 690 K 32 20,60 T56S1005
1750 56C
1/2 180 2.5 TENV CDP3326 690 K 31 20,60 T56S1027
2500 56C 90 5 TENV CDP3335 617 K 26 20,60 T56S1006
90 7.6 TEFC CDP3440 838 K 38 20 T56S1009
1750 56C
3/4 180 3.7 TEFC CDP3436 838 K 38 20 T56S1029
2500 56C 90 7.5 TEFC CDP3443 741 K 36 20
and Controls
DC Motors

90 10 TEFC CDP3445 1,019 K 44 20 T56S1011


1750 56C
180 5 TEFC CDP3455 1,019 K 44 20 T56S1013
1
90 9.7 TEFC CDP3450 838 K 38 20
2500 56C
180 4.85 TEFC CDP3460 838 K 38 20 T56S1012
1750 145TC 180 7.7 TEFC CDP3575 1,879 L1 65 20
1 1/2
2500 145TC 180 7 TEFC CDP3580 1,634 L1 51 20
Dynamic Brakes
Soft Start &

1750 145TC 180 9.6 TEFC CDP3585 2,242 L1 74 20


2
2500 145TC 180 10 TEFC CDP3590 1,879 L1 64 8
1750 182TC 180 14 TEFC CDP3603 2,760 L1 112 20
3
182C 180 14 TEFC CDP3604 2,745 L1 115 20
1750
5 1810ATC 180 21.6 TEFC CDP3605 4,686 L1 160 20
NOTE: See Tach Generators on page 283 and Mounting Kits on page 284. (a) See notes on inside back flap and pages 5-6. ­267
DC Motors & Controls
HVAC Motors

Integral DC Tach 1/4 thru 5 Hp NEMA 56C thru 1810ATC


Permanent Magnet SCR
Applications: Conveyors and metering pumps (precise speed regulation).
Drive Motor -
TENV and TEFC, Features: Provides an integral 50 VDC per 1000 RPM precision tachometer
Farm Duty
Motors

C-Face with Base for closed loop drive system. Class F insulation. 20:1 constant torque
speed range with NEMA Type K control. 1/4 - 1/2 motors are TENV, all others
are TEFC.
Definite Purpose
Motors

Voltage Full Load Ap’x.


Base NEMA D.C. Amperage Catalog List Mult.
Hp Enclosure Shpg. Notes (a)
Speed Frame Number Price Sym.
Arm. Arm. Wgt.
Brake Motors

90 2.5 TENV CDPT3310 1,670 K 27 20,60


1/4 1750 56C
180 1.25 TENV CDPT3306 1,670 K 27 20,60
90 3.2 TENV CDPT3320 1,704 K 32 20,60
1/3 1750 56C
180 1.6 TENV CDPT3316 1,704 K 30 20,60
90 4.8 TENV CDPT3330 1,811 K 35 20,60
1/2 1750 56C
180 2.5 TENV CDPT3326 1,811 K 36 20,60
90 7.6 TEFC CDPT3440 1,916 K 44 20
200 & 575 Volt

3/4 1750 56C


180 3.7 TEFC CDPT3436 1,916 K 45 20
Motors

90 10 TEFC CDPT3445 2,137 K 50 20


1 1750 56C
180 5 TEFC CDPT3455 2,137 K 50 20
1 1/2 1750 143TC 180 7.7 TEFC CDPT3575 2,967 L1 69 20
2 1750 143TC 180 9.6 TEFC CDPT3585 3,329 L1 79 20
3 1750 182ATC 180 14 TEFC CDPT3603 3,872 L1 122 20
5 1750 1810ATC 180 24.5 TEFC CDPT3605 5,793 L1 161 20
IEC Frame

(a) See notes on inside back flap and pages 5-6.


Motors

Explosion Proof
1/4 thru 1 1/2 Hp NEMA 56C thru 145TC
Permanent Magnet SCR
Drive Motor - TEFC, Applications: Conveyors, feeders, and pumps (adjustable speed and
constant torque for hazardous locations).
50 Hertz

C-Face with Base


Motors

Features: NEMA C-Face with welded on base. 20:1 constant torque


speed range. UL and CSA. Class I, Group D; Class II, Group F & G. T3C.
Thermostat and explosion proof conduit box included. Not tach adaptable.
Motors & Controls
Inverter/Vector

Voltage Full Load Ap’x.


Base NEMA D.C. Amperage Catalog List Mult.
Hp Shpg. Notes (a)
Speed Frame Number Price Sym.
Arm. Arm. Wgt.
and Controls
DC Motors

90 2.7 CDPX3410 1,605 K 38 20, 59


1/4 1750 56C
180 1.3 CDPX3406 1,605 K 38 20, 59
90 3.6 CDPX3420 2,017 K 42 20, 59
1/3 1750 56C
180 1.7 CDPX3416 2,017 K 44 20, 59
90 5.2 CDPX3430 2,278 K 46 20, 59
1/2 1750 56C
180 2.5 CDPX3426 2,278 K 46 20, 59
Dynamic Brakes

90 7 CDPX3440 2,816 K 51 20, 59


Soft Start &

3/4 1750 56C


180 3.5 CDPX3436 2,816 K 51 20, 59
90 9.6 CDPX3545 3,751 K 72 20, 59
1 1750 56C
180 4.9 CDPX3555 3,751 K 71 20, 59
1 1/2 1750 145TC 180 7.1 CDPX3575 4,010 L1 81 20, 59
(a) See notes on inside back flap and pages 5-6.
­268
DC Motors & Controls

HVAC Motors
Washdown Duty 1/4 thru 5 Hp NEMA 56C thru 1810ATC
Permanent Magnet SCR
Drive Motor - TENV and Applications: Food processing conveyors and feeders exposed to high
pressure wash down.
TEFC, C-Face

Farm Duty
Motors
Features: Moisture sealant on bolt heads between frame and endplates,
with Base neoprene gasketed conduit box. Double sealed ball bearings. Forsheda®
running contact v-ring slinger. Stainless steel shaft. Electrostatic epoxy
paint coating. Class F insulation. 20:1 constant torque speed range.
Tach adaptable. 3300P motors are TENV, all others are TEFC.

Definite Purpose
Motors
Voltage Full Load Ap’x.
Base NEMA D.C. Amperage Catalog List Mult.
Hp Enclosure Shpg. Notes (a)
Speed Frame Number Price Sym.
Wgt.

Brake Motors
Arm. Arm.
90 2.5 TENV CDPWD3310 757 K 23 20,60
1/4 1750 56C
180 1.25 TENV CDPWD3306 757 K 24 20,60
90 3.2 TENV CDPWD3320 799 K 27 20,60
1/3 1750 56C
180 1.6 TENV CDPWD3316 799 K 27 20,60
90 4.8 TENV CDPWD3330 898 K 32 20,60
1/2 1750 56C
180 2.5 TENV CDPWD3326 898 K 32 20,60

200 & 575 Volt


90 7.6 TEFC CDPWD3440 1,085 K 38 20

Motors
3/4 1750 56C
180 3.7 TEFC CDPWD3436 1,085 K 38 20
90 10 TEFC CDPWD3445 1,324 K 44 20
1 1750 56C
180 5 TEFC CDPWD3455 1,324 K 44 20
1 1/2 1750 145TC 180 7.7 TEFC CDPWD3575 2,533 L1 66 20
2 1750 145TC 180 9.6 TEFC CDPWD3585 3,023 L1 73 20
3 1750 182TC 180 14 TEFC CDPWD3603 3,869 L1 114 20

IEC Frame
5 1750 1810ATC 180 24.5 TEFC CDPWD3605 6,556 L1 157 20

Motors
NOTE: See Tach Generators on page 283. Mounting kits on page 284.
(a) See notes on inside back flap and pages 5-6.

Paint Free Washdown 1/4 thru 1 Hp NEMA 56C


Duty Permanent Magnet

50 Hertz
Motors
SCR Drive Motor, TEFC, Applications: Food processing, packaging exposed to high pressure
washdown with caustic solutions.
C-Face with Base
Features: Class F insulation; 20:1 constant torque speed range.

Motors & Controls


Moisture resistant 200°C magnet wire. Sealed ball bearings with moisture

Inverter/Vector
resistant grease. Contact lip seals on shaft extensions. Neoprene gaskets.
Special processed endplates. 300 series stainless steel motor frame, base,
shaft and hardware. No exterior paint. Tropicalized. Not tach adaptable.
and Controls
DC Motors

Voltage Full Load Ap’x.


Base NEMA D.C. Amperage Catalog List Mult.
Hp Shpg. Notes (a)
Speed Frame Number Price Sym.
Arm. Arm. Wgt.

90 2.7 CDPSWD3410 906 K 29 20


1/4 1750 56C
180 1.3 CDPSWD3406 906 K 28 20
Dynamic Brakes
Soft Start &

90 5.2 CDPSWD3430 1,074 K 37 20


1/2 1750 56C
180 2.5 CDPSWD3426 1,074 K 38 20
90 9.6 CDPSWD3545 1,588 K 63 20
1 1750 56C
180 4.9 CDPSWD3555 1,588 K 63 20
(a) See notes on inside back flap and pages 5-6.

­269
DC Motors & Controls
HVAC Motors

Metric Flange 0.15 thru 5 kW IEC D63 thru D112D


Permanent Magnet 0.2 thru 3.7 Hp
SCR Drive Motor, TENV Applications: Metric SCR Drive Motor replacement.
and TEFC, Flange and
Farm Duty
Motors

Face Mount Features: Metric Flange or C-Face per IEC 60072-1 Standards. Bolt on
non-metric base. Class F insulation. Tach adaptable except type 15kW. 20:1
constant torque speed range. Conforms to IEC 60034-1.
Definite Purpose
Motors

Voltage Full Load Catalog Ap’x.


Base NEMA D.C. Amperage List Mult.
kW/Hp Enclosure Number Shpg. Notes (a)
Speed Frame Price Sym.
Arm. Arm. Wgt.
Brake Motors

B5 Flange
.15/.20 1800 D63D 180 1.1 TENV VP7424D 404 DS 11 60
.18/.25 1750 D71D 180 1.25 TENV VP3311D 584 K 24 20,60
.25/.33 1750 D71D 180 1.6 TENV VP3316D 617 K 28 20,60
1750 D71D 180 2.5 TENV VP3326D 690 K 31 20,60
.37/.5
3000 D71D 180 2.5 TEFC VP3428D 715 K 32 20
200 & 575 Volt

1750 D80D 180 3.7 TEFC VP3436D 838 K 41 20


.57/.75
Motors

3000 D80D 180 3.6 TEFC VP3439D 741 K 37 20


1750 D80D 180 5 TEFC VP3455D 1,019 K 46 20
.75/1
3000 D80D 180 5.1 TEFC VP3458D 838 K 41 20
3000 D90D 180 7.7 TEFC VP3468D 934 L1 47 20
1.1/1.5
1750 D90D 180 7.7 TEFC VP3575D 1,889 L1 68 20
1750 D90D 180 9.6 TEFC VP3585D 2,254 L1 77 20
1.5/2
IEC Frame

3000 D90D 180 10 TEFC VP3588D 1,889 L1 69 20


Motors

2.2/3 1750 D112D 180 14 TEFC VP3603D 2,774 L1 124 20


3.7/5 1750 D112D 180 24.5 TEFC VP3605D 4,710 L1 165 20
B14 Face
.15/.20 1800 D63D 180 1.1 TENV VP7424-14 404 DS 5 60
.18/.25 1750 D71C 180 1.4 TEFC VP3411-14 657 K 30 20
.25/.33 1750 D71C 180 1.7 TEFC VP3416-14 700 K 31 20
50 Hertz

3000 D71C 180 2.5 TEFC VP3428-14 715 K 31 20


Motors

1.37/.50
1750 D71C 180 2.5 TEFC VP3426-14 741 K 37 20
3000 D80C 180 3.6 TEFC VP3439-14 741 K 35 20
.56/.75
1750 D80C 180 3.7 TEFC VP3436-14 838 K 39 20
3000 D80C 180 5.1 TEFC VP3458-14 838 K 38 20
.75/1
1750 D80C 180 5 TEFC VP3455-14 1,019 K 44 20
Motors & Controls
Inverter/Vector

3000 D80C 180 7.7 TEFC VP3468-14 934 L1 43 20


1.1/1.5
1750 D90C 180 7.7 TEFC VP3575-14 1,889 L1 71 20
3000 D90C 180 10.0 TEFC VP3588-14 1,889 L1 70 20
1.5/2
1750 D90C 180 9.6 TEFC VP3585-14 2,254 L1 80 20
NOTE: Above motors D71 and larger with B5 flange, fitted with oil seal. Catalog numbers VP7424D and VP7424-14 are not tach adaptable.
Tach Generators are shown on page 283. Tach Mounting Kits are shown on page 284.
(a) See notes on inside back flap and pages 5-6.
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­270
DC Motors & Controls

HVAC Motors
Low Voltage Permanent 1/4 thru 1 Hp NEMA 56C
Magnet Motor -
Applications: Battery operation for portable pumps, fans, augers,
TENV and TEFC winches and lifts.

Farm Duty
Motors
Features: NEMA C-face, Class F insulation, double sealed ball bearings.
Top-mounted terminal studs for power connection on ratings 40-amps and
up. Not tach adaptable. 1/4 - 1/2 Hp are TENV, 3/4 - 1 Hp are TEFC.

Definite Purpose
Motors
Ap’x.
Base NEMA Voltage Full Load Catalog List Mult.
Hp Shpg. Notes (a)
Speed Frame D.C. Amperage Number Price Sym.
Wgt.
12 22.5 CDP3410-V12 628 K 30 20,60
1/4 1800 56C

Brake Motors
24 10.6 CDP3410-V24 596 K 29 20,60
12 28.6 CDP3420-V12 690 K 30 20,60
1/3 1800 56C
24 13.6 CDP3420-V24 658 K 30 20,60
12 40 CDP3430-V12 715 K 33 20,60
1/2 1800 56C
24 19.6 CDP3430-V24 682 K 34 20,60
56C 12 66 CDP3440-V12 1,026 K 42 20
3/4 1800
56CZ 24 29.4 CDP3440-V24 711 K 35 20

200 & 575 Volt


12 85.6 CDP3445-V12 1,486 K 45 20
1 1800 56C

Motors
24 34.2 CDP3445-V24 1,479 K 44 20
(a) See notes on inside back flap and pages 5-6.

DC Power Motor -

IEC Frame
1/3 thru 1 1/2 Hp NEMA 56 thru 184

Motors
TEFC, Rigid Base
Applications: Cranes, hoists, conveyors, augers and marine duty
DC applications. Powered from generators or batteries.

Features: 20% Compound Wound. Weather proof, meets IEEE 45


specifications. Suitable for mounting in any position. Continuous duty.

50 Hertz
Motors
Easy access brushes. Not tach adaptable.

Motors & Controls


Inverter/Vector
Ap'x
NEMA Rated Catalog List Mult.
Hp Speed Shpg. Notes (a)
Frame Current Number Price Sym.
Wgt.
115 VDC
1/3 1750 56 3.2 D1151 1,143 K 23 20
1/2 1750 56 4.8 D1152 1,222 K 29 20
3/4 1750 56 6.6 D1153 1,435 K 34 20
and Controls

1 1750 56 8 D1154 1,688 K 62 20


DC Motors

230 VDC
1/3 1750 56 1.7 D2301 1,143 K 30 20
1/2 1750 56 2.1 D2302 1,225 K 29 20
3/4 1750 56 3.3 D2303 1,435 K 33 20
1 1750 56 4 D2304 1,688 K 61 20
1 1/2 1750 184 6.1 D2305 2,965 L1 82 20
Dynamic Brakes
Soft Start &

NOTE: Not for SCR control applications. Base welded on 3513D type only. Not tach adaptable.
(a) See notes on inside back flap and pages 5-6.

­271
DC Motors & Controls
HVAC Motors

Shunt Wound 1/4 thru 3 Hp NEMA 56C thru 184TC


SCR Drive Motors, Applications: Conveyors, printing, textile equipment, machine tools
TEFC & Explosion Proof (adjustable speeds with constant torque).
C-Face with Base
Farm Duty

Features: TEFC enclosure, shunt wound, Class F insulation. Designed for


Motors

use with NEMA TYPE K SCR control, 20:1 constant torque speed range
(except where noted). NEMA C-face and removable base (1) (except on
explosion proof models). NEMA 182 and larger have a thermostat (normally
closed contracts) on the field winding.
Definite Purpose
Motors

Voltage Full Load Ap’x.


Base NEMA D.C. Amperage Catalog List Mult.
Hp Shpg. Notes (e)
Speed Frame Number Price Sym.
Arm. Field Arm. Field (c) Wgt.
1/4 1750 56C 90 100/50 3 .3/.6 CD3425 588 K 23 20
Brake Motors

90 100/50 3.4 .4/.8 CD3433 642 K 24 20


1/3 1750 56C 180 200/100 1.9 .21/.42 CD3434 642 K 24 20
90 100/50 3.7 .5/1 CD5333 (a)(d) 926 K 32 20
90 100/50 5.7 .5/1 CD3450 730 K 29 20
1/2 1750 56C 180 200/100 2.6 .25/.5 CD3451 730 K 29 20
90 100/50 5 .44/.88 CD5350 (d) 1,024 K 38 20
200 & 575 Volt

90 100/50 7.8 .6/1.2 CD3475 909 K 34 20


Motors

3/4 1750 56C 180 200/100 3.9 .3/.6 CD3476 909 K 34 20


90 100/50 8 .6/1.2 CD5375 (d) 1,205 K 47 20
180 200/100 5 .3/.6 CD5318 (d) 1,283 K 53 20
56C
90 100/50 10 .6/1.2 CD5319 (d) 1,283 K 52 20
1 1750
180 200/100 5 .25/.5 CD6218 1,715 L1 65 20
182C
90 100/50 9.6 .55/1.1 CD6219 1,715 L1 64 20
IEC Frame

1 1/2 1750 182C 180 200/100 7.5 .25/.5 CD6215 1,921 L1 82 20


Motors

2 1750 182C 180 200/100 9.5 .4/.8 CD6202 2,272 L1 96 20


3 1750 184TC 180 200/100 14.7 .6/1.2 CD6203 2,580 L1 135 8, 73
Explosion-Proof - Continuous Duty - Class I, Group D & Class II, Group F & G - 1.0 S.F.
1/2 1750 182CZ 90 100/50 4.9 .55/1.1 CDX1850 (b) 2,330 L1 103 2
3/4 1750 182CZ 90 100/50 7 .55/1.1 CDX1875 (b) 3,087 L1 102 2
182CZ 180 200/100 5 .25/.5 CDX2001 (b) 3,841 L1 105 2
50 Hertz
Motors

1 1750
182C 180 200/100 5 .25/.5 CDX7100 3,187 L1 103 2
1 1/2 1750 182C 180 200/100 7.5 .25/.5 CDX7150 4,221 L1 118 2
2 1750 182C 180 200/100 9.5 .4/.8 CDX7200 (b) 4,741 L1 137 2
NOTE: See Tach Generators on page 283 and Mounting Kits on page 284. Tach Mounting Kits are not available for explosion-proof motors.
Motors & Controls

(a) Base welded on type 3513D only.


Inverter/Vector

(b) Refers to shaft and/or face mounting dimensions only. Base mounting dimensions and shaft height differ from NEMA frames shown. Go to www.baldor.com for details.
(c) Field amps for high voltage connection.
(d) No dual mounting base holes on 35D, 75D or 91D type.
(e) See notes on inside back flap and pages 5-6.

Explosion-proof ratings UL and CSA, Class I, Group D & Class II, Group F & G, will not exceed surface temperature of 165°C, equivalent to Code T3B.
* F2 Mount
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­272
DC Motors & Controls

HVAC Motors
RPM III DC Shunt 1.5 thru 5 Hp NEMA 189ATY thru 2112ATCZ
Wound SCR Drive Applications: Metals, paper, web processes, extruders, cranes, conveyors,
Motors, 180V Armature packaging, printing, machine tools.
Power Code K

Farm Duty
Features: Unique laminated square frame for improved commutation on

Motors
rectified power supplies. The square configuration allows for increased
rating per frame size. Class F rated insulation system. Service Line brushes
with convenient wear indicating reference lines. PLS™ (Positive Lubrication
System) for longer bearing and motor life. F-3 mounting. Tach adaptable with
thermostat.

Definite Purpose
Motors
Voltage Full Load Ap’x.
Base NEMA D.C. Amperage Catalog List Mult. Reliance Field XPY
Hp Enclosure Shpg.
Speed Frame Number Price Sym. M/N Type Tach Kit

Brake Motors
Arm. Field Arm. Field (a)(b) Wgt.

1.5 1750 DC189ATY (c) 180 100/200 7.2 0.721 TENV D1815R 4,275 N2 169 T18R1119 STR 413336-1R
2 1750 DC189ATY (c) 180 100/200 9.5 0.72 TENV D1802R 5,135 N2 166 T18R1117 STR 413336-1R
DC1811ATCZ (d) 180 100/200 14.1 1.21 TENV CD1803R 6,594 N2 218 T18R1102 STR 413336-1R
3 1750 DC189ATY (c)(e) 180 100/200 14.8 0.946 DPG D1803R 4,169 N2 130 T18R1118 STR 413336-1R
DC189ATCZ (d)(e) 180 100/200 14.8 0.946 DPG CDD1803R 4,169 N2 160 T18R1120 STR 413336-1R

200 & 575 Volt


DC1810ATCZ (d)(e) 180 100/200 24 1.67 DPG CD1805R 6,395 N2 175 T18R1105 STR 413336-1R
5 1750

Motors
DC2112ATCZ (d) 180 100/200 23 1.3 TENV CD2105R 10,963 N2 400 T21S1101 STR 413336-1R
NOTE: Encoder and tachometer kits on page 277.
(a) Field amps at 25°C
(b) Field amps for high voltage connection
(c) 140TC C-face
(d) 180TC C-face
(e) Top mounted conduit box, if blower added, blower must be mounted F-1 or F-2.

IEC Frame
Motors
RPM III DC Shunt 3 thru 10 Hp NEMA 1811ATCZ thru 2113ATCZ
Wound SCR Drive Applications: Textile range drives, roofing machines, tube mills, and similar
Motors, 240V Armature applications.

50 Hertz
240V Field, Power

Motors
Features: Range drive motors have matched IR drops within approximately
Code C 5 volts and good regulation characteristics out to the maximum field
weakened speed of 2300 rpm. Capable of operation at 25% base speed with
67% armature current and motor field pre-weakened to 2100 rpm. Specially
designed for use on multi-motor drives operating on a common voltage power

Motors & Controls


Inverter/Vector
supply such as textile range drives, roofing machines, tube mills, etc.
F-1 mounting. Tach adaptable with thermostat.

Voltage Full Load


and Controls

Ap’x.
DC Motors

Base NEMA D.C. Amperage Catalog List Mult. Reliance Field XPY
Hp Enclosure Shpg.
Speed Frame Number Price Sym. M/N Type Tach Kit
Arm. Field Arm. Field (a) Wgt.
3 1750/2300 C1811ATCZ (b) 240 240 11 0.994 SPG CD2003R-2 5,083 N2 180 T18R1009 STAB 413336-1R
5 1750/2300 C1811ATCZ (b) 240 240 18.1 1.11 SPG CD2005R-2 6,892 N2 180 T18R1010 STAB 413336-1R
7.5 1750/2300 C1812ATCZ (b) 240 240 27 1.4 SPG CD2007R-2 8,554 N2 215 T18R1011 STAB 413336-1R
Dynamic Brakes

10 1750/2300 SC2113ATCZ (c) 240 240 37 2.18 SPG D2010R-2 9,596 N2 360 T21S1001 STAB 417708-21
Soft Start &

NOTE: Encoder and tachometer kits on page 277.


(a) Field amps at 25°C
(b) 180TC C-face
(c) 210TC C-face

­273
DC Motors & Controls
HVAC Motors

RPM III DC Shunt 5 thru 50 Hp NEMA 1812ATZ thru 3212ATZ


Wound SCR Drive Applications: Metals, paper, web processes, extruders, cranes, conveyors,
TEFC Motors, 240V & packaging, printing, machine tools.
500V Armature, Power
Farm Duty

Features: Unique laminated square frame for improved commutation on


Motors

Code C rectified power supplies. The square configuration allows for increased
rating per frame size. Class F rated insulation system. Service Line brushes
with convenient wear indicating reference lines. PLS™ (Positive Lubrication
System) for longer bearing and motor life. F-1 mounting unless otherwise
specified. Tach adaptable with thermostat.
Definite Purpose
Motors

Voltage Full Load Ap’x.


Base/Max NEMA D.C. Amperage Catalog List Mult. Reliance Field XPY
Hp Shpg. Notes
Speed Frame Number Price Sym. M/N Type Tach Kit
Arm. Field Arm. Field (a)(b) Wgt.
C1812ATZ 240 150 18.5 1.79 D2505R 8,737 N2 235 87 T18R1005 (d) STAB 417709-17
Brake Motors

5 1750/2300
SC2113ATZ 500 150/300 9 1.05 D5505R 8,737 N2 345 87 T21S201 (c) STAB 417708.21
SC2113ATZ 240 150 27 3.26 D2507R 10,579 N2 380 87 T21S301 STAB 417709-65
7.5 1750/2300
SC2113ATZ 500 150/300 13.5 1.41 D5507R 10,579 N2 375 87 T21S302 (d) STAB 417709-65
MC2113ATZ 240 150 35.5 3.13 D2510R 12,085 N2 380 87 T21S303 STAB 417709-65
10 1750/2300
MC2113ATZ 500 150/300 17.5 1.55 D5510R 12,085 N2 290 87 T21S304 STAB 417709-65
SC2512ATZ 240 150 53.5 2.17 D2515R 15,609 N2 555 6.87 T25S301 STAB 417709-66
15 1750/2300
200 & 575 Volt

SC2512ATZ 500 150/300 25.6 1.71 D5515R 15,609 N2 555 87 T25S302 STAB 417709-66
LC2512ATZ 240 150 71 4.14 D2520R 17,936 N2 630 87 T25S303 STAB 417709-66
Motors

20 1750/2300
LC2512ATZ 500 150/300 33 2.05 D5520R 17,936 N2 630 87 T25S304 STAB 417709-66
MC2812ATZ 240 150 87 4.05 D2525R 21,012 N2 825 87 T28S301 STAB 417709-67
25 1750/2300
MC2812ATZ 500 150/300 41 2.23 D5525R 21,012 N2 825 86,87 T28S302 STAB 417709-67
30 1750/2300 LC2812ATZ 500 150/300 50 1.75 D5530R 23,264 N2 900 87 T28S303 STAB 417709-67
40 1750/2300 MC3212ATZ 500 150/300 65 1.82 D5540R 29,367 N2 1150 87 T32S301 STAB 417709-68
50 1750/2300 LC3212ATZ 500 150/300 84 1.97 D5550R 35,357 N2 1325 87 T32S302 STAB 417709-68
IEC Frame
Motors

NOTE: Encoder and tachometer kits on page 277.


(a) Field amps at 25°C
(b) Field amps for high voltage connection
(c) TENV enclosure
(d) Power Code D
50 Hertz
Motors
Motors & Controls
Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­274
DC Motors & Controls

HVAC Motors
RPM III Wound Field SCR 10 thru 500 Hp NEMA 2113ATZ thru 4414ATZ
Drive DPG-FV Motors, Applications: Metals, printing, extruders, cranes, conveyors, machine tools
240V & 500V Armature,
Power Code C Features: Laminated square frame for improved commutation. Tach

Farm Duty
adaptable with thermostat. F1 mount unless otherwise specified.

Motors
Voltage Full Load Ap’x.
Base/Max NEMA D.C. Amperage Catalog List Mult. Reliance Field XPY
Hp Shpg. Notes
Speed Frame Number Price Sym. M/N Type Tach Kit
Arm. Field Arm. Field (a) Wgt.
10 1750/2300 SC2113ATZ 500 300 18 1.11 D5010RS-BV 14,382 N2 415 (c) 91,92 T21T1342 STAB 417708-21

Definite Purpose
SC2113ATZ 240 150 56 4.73 D2015R-BV 12,333 N2 385 (d) 93 T21T1359 STR 417708-21

Motors
SC2113ATCZ 240 150 56 4.73 CD2015R-BV 12,928 N2 385 (b) 93 T21T1384 STR 417708-21
15 1750/2300
SC2113ATZ 500 300 27 2.22 D5015R-BV 12,333 N2 345 93 T21T1364 STR 417708-21
SC2113ATZ 500 300 27 3.03 D5015RS-BV 16,615 N2 345 (c) 91,92 T21T1346 STAB 417708-21
SC2113ATZ 240 150 76.5 7.12 D2020R-BV 13,834 N2 400 (d) 93 T21T1363 STR 417708-21
20 1750/2300 SC2113ATZ 500 300 37 3.03 D5020R-BV 13,834 N2 395 93 T21T1350 STR 417708-21
MC2113ATZ 500 300 37 2.23 D5020RS-BV 18,415 N2 440 (c) 91,92 T21T1344 STAB 417708-21

Brake Motors
MC2113ATZ 240 150 96 8.43 D2025R-BV 15,305 N2 425 (d) 93 T21T1371 STR 417708-21
25 1750/2300 MC2113ATZ 500 300 46 3.33 D5025R-BV 15,305 N2 370 6,94 T21T1351 STR 417708-21
LC2113ATZ 500 300 43 3.08 D5025RS-BV 20,181 N2 470 (c) 91,92 T21T1345 STAB 417708-21
LC2113ATZ 240 150 109 10 D2030R-BV 16,632 N2 400 93 T21T1375 STR 417708-21
1750/2300
LC2113ATZ 500 300 52 3.3 D5030R-BV 16,632 N2 450 93 T21T1352 STR 417708-21
30
1750/2300 SC2512ATZ 500 300 51 2.84 D5030RS-BV 21,773 N2 565 (c) 91,92 T25T1342 STAB 417708-21

200 & 575 Volt


1150/1800 LC2115ATZ 500 300 54 3.94 D5130R-BV 21,017 N2 550 94 T21T1378 STR 417708-21
1750/2300 LC2115ATZ 240 150 146 5.63 D2040R-BV 19,785 N2 480 6,93 T21T1380 STR 417708-21

Motors
MC2115ATZ 500 300 69 4.48 D5040R-BV 19,785 N2 425 93 T21T2353 STR 417708-21
40 1750/2100
MC2512ATZ 500 300 68.5 2.88 D5040RS-BV 25,983 N2 570 (c) 6,91,92 T25T1344 STAB 417708-21
1150/2000 LC2512ATZ 500 300 72 5.27 D5140R-BV 24,453 N2 650 94 T25T1355 STR 417708-21
LC2115ATZ 500 300 87 3.94 D5050R-BV 22,211 N2 530 93 T21T2354 STR 417708-21
1750/2100
50 LC2512ATZ 500 300 84 3.38 D5050RS-BV 28,466 N2 610 (c) 6,91,92 T25T1339 STAB 417708-21
1150/1900 C2514ATZ 500 300 87 4.06 D5150R-BV 27,744 N2 735 6,94 T25T1359 STR 417708-21

IEC Frame
Motors
LC2512ATZ 500 300 102 4.6 D5060R-BV 25,028 N2 650 93 T25T2348 STR 417708-21
1750/2100
60 MC2812ATZ 500 300 100 3.43 D5060RS-BV 31,848 N2 810 (c) 6,91,92 T28T1330 STAB 417708-26
1150/1900 C2515ATZ 500 300 102 5.17 D5160R-BV 31,311 N2 870 6,93 T25T1364 STR 417708-21
C2514ATZ 500 300 124 6.21 D5075R-BV 28,928 N2 695 93 T25T2349 STR 417708-21
1750/2100
75 LC2812ATZ 500 300 124 3.62 D5075RS-BV 36,528 N2 930 (c) 6,91,92 T28T1327 STAB 417708-26
1150/2000 C2815ATZ 500 300 125 4.14 D5175R-BV 36,330 N2 1190 6,93 T28T1342 STR 417708-26
1750/2000 C2515ATZ 500 300 167 6.7 D50100R-BV 35,595 N2 870 93 T25T2350 STR 417708-21

50 Hertz
Motors
100 1750/2100 MC3212ATZ 500 300 162 3.33 D50100RS-BV 44,526 N2 1210 (c) 6,91,92 T32T1314 STAB 417708-26
1150/1850 C2815ATZ 500 300 168 4.14 D51100R-BV 43,793 N2 1240 6,94 T28T1344 STR 417708-26
C2813ATZ 500 300 204 6.93 D50125R-BV 41,651 N2 940 6,93 T28T1333 STR 417708-26
1750/2000
UC2813ATZ 500 300 204 6.93 D50125UR-BV 42,888 N2 945 5,6,93 T28T1349 STR 417708-26
125
1750/2100 LC3212ATZ 500 300 203 4.4 D50125RS-BV 51,797 N2 1290 (c) 6,91,92 T32T1318 STAB 417708-26

Motors & Controls


1150/2000 UC3214ATZ 500 300 204 8.36 D51125RR-BV 52,096 N2 1475 5,6,93 T32T1327 STR 417708-26

Inverter/Vector
C2815ATZ 500 300 245 9.45 D50150R-BV 47,534 N2 1125 6,93 T28T1334 STR 417708-26
1750/2000
UC2815ATZ 500 300 245 9.45 D50150UR-BV 48,779 N2 1255 5,6,93 T28T1350 STR 417708-26
150
1750/2100 MC3612ATZ 500 300 240 4.8 D50150RS-BV 58,856 N2 1685 (c) 6,95 T36S1313 STAB 417708-26
1150/2000 ULC3612ATZ 500 300 249 7.29 D51150RR-BV 60,130 N2 1860 5,6,94 T36S1323 STR 417708-26
UC3214ATZ 500 300 322 8.36 D50200RR-BV 61,614 N2 1585 5,6,93 T32T1322 STR 417708-26
1750/2100
200 LC3612ATZ 500 300 321 5.41 D50200RS-BV 74,515 N2 1850 (c) 6,95 T36S1314 STAB 417708-26
1150/2000 C3613ATZ 500 300 323 10.7 D51200R-BV 72,045 N2 2010 6,94 T36S1325 STR 417708-26
and Controls
DC Motors

ULC3612ATZ 500 300 405 8.87 D50250RR-BV 73,723 N2 1890 5,6,94 T36S1318 STR 417708-26
1750/2100
250 C4011ATZ 500 300 400 6.63 D50250RS-BV 90,167 N2 2500 (c) 6,95 T40S1306 STAB 417708-26
1150/2000 MC4013ATZ 500 300 406 10.7 D51250R-BV 87,340 N2 2800 6,94 T40S1317 STR 417708-26
1750/2000 LC3613ATZ 500 300 478 12.5 D50300R-BV 88,856 N2 2010 6,94 T36S1319 STR 417708-26
300 1750/2100 MC4013ATZ 500 300 478 6.5 D50300RS-BV 108,190 N2 2800 (c) 6,95 T40S1309 STAB 417708-26
1150/2000 LC4013ATZ 500 300 485 13.2 D51300R-BV 101,564 N2 3100 6,94 T40S1320 STR 417708-26
Dynamic Brakes

MC4013ATZ 500 300 643 11.9 D50400R-BV 121,463 N2 2800 6,94 T40S1314 STR 417708-26
Soft Start &

1750/2000
400 LC4013ATZ 500 300 635 7.97 D50400RS-BV 154,523 N2 3100 (c) 6,95 T40S1311 STAB 417708-26
1150/1600 C4413ATZ 500 300 644 13 D51400R-BV 136,315 N2 3830 6,91,94 T44T1304 STR 417708-156
1750/2050 C4412ATZ 500 300 797 10.8 D50500R-BV 164,021 N2 3480 6,91,94 T44T1305 STR 417708-156
500
1150/1450 C4414ATZ 500 300 805 12.3 D51500R-BV 172,203 N2 4560 6,91,94 T44T1306 STR 417708-156
NOTE: Encoder and tachometer kits on page 277. (a) Field amps at 25°C (c) Extruder duty enclosed commutator design
(b) 210TC C-Face (d) Power Code D ­275
DC Motors & Controls
HVAC Motors

RPM III Wound Field 3 thru 60 Hp NEMA 189ATCZ thru 2812ATZ


SCR Drive DPG Motors, Applications: Metals, paper, web processes, extruders, cranes, conveyors,
240V & 500V Armature packaging, printing, machine tools.
Power Code C
Farm Duty

Features: Unique laminated square frame for improved commutation on


Motors

rectified power supplies. The square configuration allows for increased rating
per frame size. High limit thermostat. Provision for adding adapter mounted
feedback device. Class F rated insulation system. Service Line brushes
with convenient wear indicating reference lines. PLS™ (Positive Lubrication
System) for longer bearing and motor life. F-1 mounting unless otherwise
Definite Purpose

specified.
Motors

Voltage Full Load Ap’x.


Base/Max NEMA D.C. Amperage Catalog List Mult. Reliance Field XPY
Hp Shpg. Notes
Speed Frame Number Price Sym. M/N Type Tach Kit
Brake Motors

Arm. Field Arm. Field(a)(b) Wgt.


DC189ATCZ (c)(e) 240 150 11 1.52 D2003R 4,193 N2 130 80,83 T18R1127 STAB 413336-1R
3 1750/2300
C1811ATZ 500 300 5.2 0.741 D5003R 4,943 N2 197 80 T18R1333 (d) STR 413336-1R
C1811ATZ 240 150 19.2 1.77 D2005R 6,139 N2 194 80,83 T18R1318 (d) STAB 413336-1R
5 1750/2300
C1811ATZ 500 300 9 1 D5005R 6,139 N2 175 80 T18R1334 (d) STR 413336-1R
C1811ATZ 240 150 28 1.95 D2007R 7,418 N2 197 80,83 T18R1301 (d) STAB 413336-1R
7.5 1750/2300
200 & 575 Volt

C1811ATZ 500 300 13.5 1.29 D5007R 7,418 N2 210 80 T18R1335 (d) STR 413336-1R
D2010R
Motors

C1812ATZ 240 150 37 2.12 8,459 N2 225 80,84 T18R1302 (d) STAB 413336-1R
10 1750/2300
C1812ATZ 500 300 17.4 1.08 D5010R 8,459 N2 235 80,85 T18R1307 (d) STAB 413336-1R
SC2113ATZ 240 150 56 4.12 D2015R 10,186 N2 315 87 T21S1330 STAB 417708-21
15 1750/2300
SC2113ATZ 500 150/300 27 1.76 D5015R 10,186 N2 315 87 T21S1322 STAB 417708-21
LC2113ATZ 240 150 74 4.24 D2020R 11,688 N2 370 87 T21S1331 STAB 417708-21
20 1750/2300
MC2113ATZ 500 150/300 35 1.98 D5020R 11,688 N2 375 87 T21S1323 STAB 417708-21
LC2113ATZ 240 150 91.5 5.82 D2025R 14,441 N2 410 87 T21S1332 STAB 417708-21
IEC Frame

25 1750/2300
Motors

LC2113ATZ 500 150/300 43 2.61 D5025R 14,441 N2 415 87 T21S1324 STAB 417708-21
SC2512ATZ 240 150 111 3.45 D2030R 15,900 N2 505 87 T25S1330 STAB 417708-21
30 1750/2300
SC2512ATZ 500 150/300 52 1.71 D5030R 15,900 N2 505 87 T25S1322 STAB 417708-21
40 1750/2100 LC2512ATZ 500 150/300 68 2.4 D5040R 18,713 N2 580 6,87 T25S1323 STAB 417708-21
50 1750/2100 MC2812ATZ 500 150/300 85 2.01 D5050R 21,381 N2 775 6,87 T28S1313 STAB 417708-26
60 1750/2100 LC2812ATZ 500 300 100 2.77 D5060R 24,482 N2 850 6,87 T28S1314 STAB 417708-26
NOTE: Encoder and tachometer kits on page 277.
50 Hertz
Motors

(a) Field amps at 25°C


(b) Field amps for high voltage connection
(c) 180 TC C-face
(e) Top mounted conduit box, if blower added, blower must be mounted F-1 or F-2
(d) Power Code D
Motors & Controls
Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­276
DC Motors & Controls

HVAC Motors
RPM III DC Motor Applications: Encoder and Tachometer Kits for Field Installation

Encoder and Tachometer Kits Features: Kits include the encoder or tachometer and all mounting
hardware required for installation on RPM III DC Motors.
Device Catalog List Mult. Ap’x.
Output Frames Enclosure

Farm Duty
Type Number Price Sym. Shpg. Wgt.

Motors
417708-30 DC180, C180, DC2112 DPG, DPFV 2,444 E8 5
417708-32 C210-C250 DPG, DPFV, TENV 2,444 E8 5
RD120-1 1 x 120 ppr
417708-33 C280-C400 DPG, DPFV, TENV 2,444 E8 5
417708-153 C440 DPG, DPFV, TENV 2,444 E8 5
417708-34 DC180, C180, DC2112 DPG, DPFV 3,002 E8 5

Definite Purpose
417708-36 C210-C250 DPG, DPFV, TENV 3,002 E8 5
RD120-2 2 x 120 ppr
417708-37 C280-C400 DPG, DPFV, TENV 3,002 E8 5

Motors
417708-154 C440 DPG, DPFV, TENV 3,002 E8 5
417708-133 DC180, C180, DC2112 DPG, DPFV, TENV 3,258 E8 5
417708-134 C210-C250 DPG, DPFV, TENV 3,258 E8 5
H20 1024 ppr
417708-135 C280-C400 DPG, DPFV, TENV 3,258 E8 5
417708-151 C440 DPG, DPFV, TENV 3,258 E8 5
417708-126 DC180, C180, DC2112 DPG, DPFV, TENV 4,275 E8 4

Brake Motors
417708-136 C210-C250 DPG, DPFV, TENV 4,275 E8 6
RL67 1024z ppr
417708-137 C280-C400 DPG, DPFV, TENV 4,275 E8 6
417708-138 C440 DPG, DPFV 4,275 E8 4
413327-W DC180, C180, DC2112 DPG, DPFV, TENV 3,257 E8 8
45 VAC/ 417708-20 C210-C250 DPG, DPFV, TENV 3,257 E8 11
RE045
1000 RPM 417708-25 C280-C400 DPG, DPFV, TENV 3,257 E8 11

200 & 575 Volt


417708-152 C440 DPG, DPFV, TENV 3,257 E8 13

Motors
IEC Frame
Motors
Encoder and Tachometer Applications: Encoder and Tachometer mounting kits for field installation
Mounting Kits (less tach) Features: Kits include all mounting hardware required for installation on
RPM III DC motors. Feedback device not included.

50 Hertz
Motors
Device Catalog List Mult. Ap’x.
Frames Enclosure
Type Number Price Sym. Shpg. Wgt.
413336-2R DC180, C180, DC2112 DPG, DPFV, TENV 1,080 E8 9
417708-22 C210-C250 DPG, DPFV, TENV 1,080 E8 9
417708-27 C280-C400 DPG, DPFV, TENV 1,080 E8 9

Motors & Controls


Inverter/Vector
XC42, XC46, BC42, 417708-155 C440 DPG, DPFV, TENV 1,080 E8 9
BC46, H56, 417709-21 C180 TEFC 2,159 E8 19
800123-R & -S 417709-58 C210 TEFC 2,159 E8 20
417709-59 C250 TEFC 2,159 E8 23
417709-60 C280 TEFC 2,159 E8 23
417709-61 C320 TEFC 2,159 E8 29
413336-1R DC180, C180, DC2112 DPG, DPFV, TENV 1,080 E8 7
and Controls

417708-21 C210-C250 DPG, DPFV, TENV 1,080 E8 7


DC Motors

417708-26 C280-C400 DPG, DPFV, TENV 1,080 E8 7


417708-156 C440 DPG, DPFV, TENV 1,080 E8 8
XPY, XPYII,
417709-17 C180 TEFC 2,159 E8 6
5PY, RPY444
417709-65 C210 TEFC 2,159 E8 6
417709-66 C250 TEFC 2,159 E8 9
417709-67 C280 TEFC 2,159 E8 15
Dynamic Brakes

417709-68 C320 TEFC 2,159 E8 18


Soft Start &

417708-40 DC180, C180, DC2112 DPG, DPFV, TENV 205 E8 1


417708-41 C210 - C250 DPG, DPFV, TENV 205 E8 2
RL67
417708-42 C280 - C400 DPG, DPFV, TENV 205 E8 1
417708-157 C440 DPG, DPFV, TENV 256 E8 1

­277
DC Motors & Controls
HVAC Motors

Blower Kits for use with RPM III DC Motors


Suitable for operation on 230/460V or 240/480V, 3-Phase, 50/60 Hz
Ap’x.
Motor Catalog List Mult.
Shpg. Description
Frame Number Price Sym.
Farm Duty

Wgt. (lb)
Motors

C180ATZ, DC180ATZ 417077-51 1,273 A8 44 Blower Kit Without Filter


C210ATZ 419947-29 1,691 A8 52 Blower Kit Without Filter
C250ATZ 419947-30 1,934 A8 39 Blower Kit Without Filter
C280ATZ 419947-32 2,179 A8 55 Blower Kit Without Filter
C320ATZ 419947-34 2,422 A8 81 Blower Kit Without Filter
Definite Purpose

C3612ATZ 417077-74 2,748 A8 55 Blower Kit Without Filter


Motors

C3613ATZ 417077-127 2,616 A8 75 Blower Kit Without Filter


C400ATZ 417077-75 2,726 A8 85 Blower Kit Without Filter
C440ATZ 417077-126 8,345 A8 225 Blower Kit Without Filter

Filter Kits for use with DPG-FV, RPM III DC motors


Brake Motors

Ap’x.
Motor Catalog List Mult.
Shpg. Description
Frame Number Price Sym.
Wgt. (lb)
C180ATZ, DC180ATZ 417077-57 554 A8 2 Washable Wire Mesh Canister Type
C2113ATZ 417077-58 704 A8 4 Washable Wire Mesh Canister Type
C2115ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
200 & 575 Volt

C2512ATZ 417077-58 704 A8 4 Washable Wire Mesh Canister Type


Motors

C2514ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type


C2515ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
C2812ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
C2813ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
C2815ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
C3210ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
IEC Frame
Motors

C3212ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type


C3214ATZ 417077-59 554 A8 4 Washable Wire Mesh Canister Type
C3612ATZ 417077-65 727 A8 7 Washable Wire Mesh Canister Type
C3613ATZ 417077-102 1,070 A8 6 Washable Wire Mesh Canister Type
C400ATZ 417077-102 1,070 A8 6 Washable Wire Mesh Canister Type
C440ATZ 417077-124 1,588 A8 18 Square Replaceable Polyester Type
50 Hertz
Motors

Sliding Bases for RPM III DC motors


Applications: Used for adjusting belt tension on belted applications. Not suitable for wall or ceiling mounting.
Motors & Controls

Ap’x.
Inverter/Vector

Motor Catalog List Mult. Dimension


Shpg. Description
Frame Number Price Sym. Sheet
Wgt.
DC1810ATZ 42384-26D 459 A8 14 Standard Duty 609987-501
DC1811ATZ 42384-26BE 551 A8 17 Heavy Duty 609987-501
C1811ATZ 42384-26BE 551 A8 17 Heavy Duty 609987-1
C1812ATZ 42384-26BF 551 A8 17 Heavy Duty 609987-1
DC2112ATZ 42384-26BH 551 A8 29 Heavy Duty 609958-51
and Controls

C2113ATZ 419914-1A 551 A8 50 Heavy Duty 609957-1


DC Motors

C2115ATZ 419914-1P 551 A8 36 Heavy Duty 609957-1


C2512ATZ 419914-1B 643 A8 33 Heavy Duty 609957-1
C2514ATZ 419914-1R 643 A8 59 Heavy Duty 609957-1
C2515ATZ 419914-1S 643 A8 36 Heavy Duty 609957-1
UC2812ATZ 419914-1C 825 A8 37 Heavy Duty 609957-1
UC2813ATZ 419914-1T 825 A8 26 Heavy Duty 609957-1
Dynamic Brakes
Soft Start &

UC2815ATZ 419914-1U 825 A8 42 Heavy Duty 609957-1


UC3212ATZ 419914-1D 825 A8 69 Heavy Duty 609977-1
UC3214ATZ 419914-1W 825 A8 76 Heavy Duty 609977-1
UC3612ATZ 419914-1E 1,630 A8 76 Heavy Duty 609977-1
UC3613ATZ 419914-1X 1,630 A8 81 Heavy Duty 609977-1

­278
DC Motors & Controls

HVAC Motors
SCR Drive Motors Shunt 5 thru 250 Hp NEMA L186AT thru 506AT
and Stabilized Shunt
Applications: Conveyors, plastic extruders, packaging machinery and other
Wound - DPFG, Self constant torque applications for DC SCR motors.
Ventilated, Rigid Base

Farm Duty
Motors
Features: Includes thermostat on interpole. Class F insulation system
resistant to dirt, carbon, dust and moisture. High dielectric stability. Low
moment of inertia armature for fast response. Constant pressure brush
springs and longer brushes for reduced maintenance. Includes grease fittings
and reliefs for bearing maintenance. Power code C and D or M-G sets.

Definite Purpose
Maximum RPM by field weakening. Provisions for tach mounting. (See tach

Motors
mounting kits on page 282). May be converted to blower ventilated (DPBV) for
extended constant torque speed range.

Voltage Full Load List


Ap’x. XPY Blower
Base/Max NEMA D.C. Amperage Catalog Price Mult.

Brake Motors
Hp Shpg. Tach Catalog Notes (e)
Speed (a) Frame Number Motors Sym.
Arm. Field Arm. Field (b) Wgt. (d) Kit Number
Only (c)
240 150/300 17.7 .68 D2005P 4,888 N2 178 TKP1836XP FVB3180 2,20
5 1750/2300 L186AT
500 150/300 8.5 .6 D5005P 4,888 N2 162 TKP1836XP FVB3180 2,20
1810AT 240 150/300 28.1 .8 D2007P 5,896 N2 239 TKP1836XP FVB3180 2,20
7 1/2 1750/2300
218AT 500 150/300 13.2 .69 D5007P 5,896 N2 239 TKP1836XP FVB3210 2,20

200 & 575 Volt


240 150/300 36.6 2.16 D2010P 6,719 N2 259 TKP1836XP FVB3210 2,20
10 1750/2300 219AT
500 150/300 17.2 1.17 D5010P 6,719 N2 255 TKP1836XP FVB3210 2,20

Motors
240 150/300 55 2.58 D2015P 8,083 N2 379 TKP1836XP FVB3250 2,20
15 1750/2300 258AT
500 150/300 25.2 1.4 D5015P 8,083 N2 379 TKP1836XP FVB3250 2,20
240 150/300 70.5 2.48 D2020P 9,268 N2 429 TKP1836XP FVB3250 2,20
20 1750/2300 259AT
500 150/300 35.1 1.24 D5020P 9,268 N2 429 TKP1836XP FVB3250 2,20
288AT 240 150/300 89.2 2.99 D2025P 10,938 N2 589 TKP1836XP FVB4280 2,20
25 1750/2300
287-8AT 500 150/300 43.4 1.64 D5025P 10,938 N2 529 TKP1836XP FVB4280 2,20

IEC Frame
Motors
240 150/300 106 4.52 D2030P 12,035 N2 589 TKP1836XP FVB4280 2,20
30 1750/2300 288AT
500 150/300 50 2 D5030P 12,035 N2 579 TKP1836XP FVB4280 2,20
40 1750/2100 328AT 500 150/300 67.9 2.17 D5040P 14,850 N2 819 TKP1836XP FVB6320 2,20
50 1750/2100 328AT 500 150/300 83.7 2 D5050P 16,923 N2 822 TKP1836XP FVB6320 2,20
60 1750/2100 365-6AT 500 150/300 98.6 1.75 D5060P 19,371 N2 815 TKP1836XP FVB6400 2,20
75 1750/2100 366AT 500 150/300 123 1.48 D5075P 22,756 N2 959 TKP1836XP FVB6400 2,20
100 1750/2000 368AT 500 150/300 158 3 D50100P 28,548 N2 1129 TKP1836XP FVB6400 2,20

50 Hertz
Motors
125 1750/2000 407AT 500 150/300 200 3 D50125P 33,807 N2 1459 TKP400XP FVB6400 2,20
150 1750/2000 409AT 500 150/300 237 3.7 D50150P 40,674 N2 1139 TKP400XP FVB6400 2,20
200 1750/1900 504AT 500 150/300 320 3.9 D50200P 51,586 N2 2149 TKP500XP FVB8500 2,20
250 1750/1900 506AT 500 150/300 392 5 D50250P 63,431 N2 2569 TKP500XP FVB8500 2,20
NOTES:

Motors & Controls


(a) DPFG enclosure is self-ventilated. Speed can be reduced to approximately 60% of base speed with constant torque.

Inverter/Vector
See performance data in CA608 catalog for specific speed-torque curves. Separate blower can be used to increase operating range below 60% of base speed.
(b) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. 360, 400 & 500 frames are 4 pole stabilized shunt until 3rd quarter 2006
when they became shunt. Others are 2 pole shunt.
(c) Does not include price of blower. See page 282 for pricing.
(d) Does not include weight of blower. See page 282 for weights.
(e) See notes on inside back flap and pages 5-6.

180 frame motors are supplied without external conduit box, see online layout drawing for details.
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­279
DC Motors & Controls
HVAC Motors

SCR Drive Motor Shunt 40 thru 500 Hp NEMA 328AT thru 5010AT
and Stabilized Shunt Applications: Conveyors, plastic extruders, packaging machinery and other
Wound DPBV Enclosure constant torque applications for DC SCR motors.
- Rigid Base
Farm Duty

Features: Includes thermostat on interpole. Class F insulation system


Motors

resistant to dirt, carton, dust and moisture. High dielectric stability. Low
moment of inertia armature for fast response. Constant pressure brush
springs and longer brushes for reduced maintenance. Includes grease fittings
and reliefs for bearing maintenance. Power code C or M-G sets. Maximum
Definite Purpose

RPM by field weakening. Provisions for tach mounting. (See tach kits on
page 282). Blower-ventilated, includes filter.
Motors

Voltage Full Load List Price Ap’x. XPY


Base/Max NEMA D.C. Amperage Catalog Mult.
Hp w/Blower Shpg. Tach Notes (b)
Speed Frame Number Sym.
Arm. Field Arm. Field (a) & Filter Wgt. Kit
Brake Motors

240 150/300 138 2.64 D2040P-BV 16,174 N2 889 TKP1836XP 2,20


40 1750/2100 328AT
500 150/300 67.9 2.17 D5040P-BV 16,174 N2 871 TKP1836XP 2,20
240 150/300 175 2.64 D2050P-BV 18,090 N2 898 TKP1836XP 2,20
50 1750/2100 328AT
500 150/300 83.7 2 D5050P-BV 18,090 N2 899 TKP1836XP 2,20
366AT 240 150/300 201 5.6 D2060P-BV 20,316 N2 996 TKP1836XP 2,20
60 1750/2100
365-6AT 500 150/300 98.6 1.75 D5060P-BV 20,316 N2 869 TKP1836XP 2,20
200 & 575 Volt

240 150/300 256 5.6 D2075P-BV 23,394 N2 1015 TKP1836XP 2,20


75 1750/2100 366AT
500 150/300 123 1.48 D5075P-BV 23,394 N2 999 TKP1836XP 2,20
Motors

100 1750/2000 368AT 500 150/300 158 3 D50100P-BV 28,489 N2 1179 TKP1836XP 2,20
125 1750/2000 368AT 500 150/300 197 3 D50125P-BV 33,440 N2 1189 TKP1836XP 2,20
150 1750/2000 407-9AT 500 150/300 238 2.7 D50150P-BV 38,358 N2 1519 TKP400XP 2,20
200 1750/1900 409AT 500 150/300 311 3.75 D50200P-BV 47,849 N2 1809 TKP400XP 2,20
250 1750/1900 504-6AT 500 150/300 405 4.9 D50250P-BV 58,661 N2 2289 TKP500XP 2,20
300 1750 506AT 500 150/300 478 6.2 D50300P-BV 69,640 N2 2659 TKP500XP 2,20
IEC Frame
Motors

400 1750/1900 508AT 500 150/300 624 6.08 D50400P-BV 98,303 N2 3289 TKP5006XP 2,20
500 1750/1900 5010AT 500 150/300 788 6 D50500P-BV 129,266 N2 4169 TKP500XP 2,20
NOTE: (a) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors.
360 through 500 frames are 4 pole stabilized shunt, until 3rd quarter 2006 when they became shunt. Others are 2 pole shunt. Tach mounting kits on page 282.
(b) See notes on inside back flap and pages 5-6.

SCR Drive Motor 240V


50 Hertz
Motors

3 thru 15 Hp NEMA L186ATC thru 258ATC


Armature - 240V Field
Shunt Wound DPFG - Applications: Conveyors, plastic extruders, packaging machinery and other
constant torque applications for DC SCR motors.
Self-Ventilated Rigid
Motors & Controls
Inverter/Vector

Base and C-Face Features: Includes thermostat on interpole. Class F insulation system
resistant to dirt, carton, dust and moisture. High dielectric stability. Low
moment of inertia armature for fast response. Constant pressure brush
springs and longer brushes for reduced maintenance. Includes grease fittings
and reliefs for bearing maintenance. Power code C or M-G sets. Maximum
RPM by field weakening.
and Controls
DC Motors

Voltage Full Load List Ap’x. XPY Blower


Base/Max NEMA D.C. Amperage Catalog Price Mult.
Hp Shpg. Tach Catalog Notes (d)
Speed Frame Number Motor Sym.
Arm. Field Arm. Field (a) (b) Wgt. (c) Kit Number

3 1750/2300 L186ATC 240 120/240 10.6 .45 CD2003P-2 4,164 N2 170 TKP1836XP FVB3180 1, 3
Dynamic Brakes

5 1750/2300 L186ATC 240 120/240 17.7 .45 CD2005P-2 5,048 N2 170 TKP1836XP FVB3180 1, 3
Soft Start &

7 1/2 1750/2300 1810ATC 240 120/240 28.1 .52 CD2007P-2 6,056 N2 233 TKP1836XP FVB3180 1, 3
10 1750/2300 219ATC 240 120/240 36.6 1.26 CD2010P-2 7,191 N2 267 TKP1836XP FVB3210 1, 3
15 1750/2300 258ATC 240 120/240 55 1.26 CD2015P-2 8,552 N2 409 TKP1836XP FVB3250 1, 3
NOTE: (a) Field amps for 240VDC connection. (b) Does not include price of blower and filter. See page 282 for pricing.
(c) Does not include weight of blower and filter. See page 282 for weights. Tach mounting kits on page 282.
­280 (d) See notes on inside back flap and pages 5-6. 180 frame motors are supplied without external conduit box, see online layout drawing for details.
DC Motors & Controls

HVAC Motors
Shunt Wound SCR 5 thru 25 Hp NEMA 1810AT THRU 328AT
Drive Motor - TEFC,
Applications: Conveyors and packaging machinery.
Rigid Base
Features: Includes thermostat on interpole, grease fittings and reliefs. Class

Farm Duty
Motors
F insulation system. Constant pressure brush springs and precision brush
holders. Provisions for tach mounting ( See tach mounting kits page 282).

Definite Purpose
Motors
Voltage Full Load List Price Ap’x. XPY
Base/Max NEMA D.C. Amperage Catalog Mult.
Hp Motors Shpg. Tach Notes (b)
Speed Frame Number Sym.
Arm. Field Arm. Field (a) Only Wgt. Kit

240 150/300 17.6 0.68 D2505P 6,939 N2 379 N/A 1, 3


5 1750/2300 1810AT
500 150/300 8.3 0.34 D5505P 7,399 N2 229 N/A 1, 3

Brake Motors
240 150/300 26.6 2.10 D2507P 8,394 N2 319 TKP2136XPT 1, 3
7 1/2 1750/2300 2110AT
500 150/300 12.3 1.05 D5507P 8,394 N2 319 TKP2136XPT 1, 3
240 150/300 34.3 1.72 D2510P 9,582 N2 459 TKP2136XPT 1, 3
10 1750/2300 259AT
500 150/300 16.3 0.86 D5510P 9,582 N2 459 TKP2136XPT 1, 3
240 150/300 51.7 1.96 D2515P 12,366 N2 629 TKP2136XPT 1, 3
15 1750/2300 288AT
500 150/300 24.5 0.99 D5515P 12,366 N2 629 TKP2136XPT 1, 3

200 & 575 Volt


240 150/300 68.8 2.22 D2520P 14,202 N2 879 TKP2136XPT 1, 3
20 1750/2300 328AT
D5520P

Motors
500 150/300 32.7 1.11 14,202 N2 867 TKP2136XPT 1, 3
240 150/300 84.8 2.22 D2525P 16,632 N2 872 TKP2136XPT 1, 3
25 1750/2300 328AT
500 150/300 40.9 1.11 D5525P 16,632 N2 870 TKP2136XPT 1, 3
NOTE: (a) Field amps are for 150V connection on 240VDC motors; 300V connection on 500VDC motors. Tach mounting kits on page 282.
(b) See notes on inside back flap and pages 5-6.
180 frame motors are supplied without external conduit box, see online layout drawing for details.

IEC Frame
Motors
Lifting Magnet 5 thru 40 kW NEMA 1810AT thru 329AT
Generators
Applications: Crane mounted lifting magnets for recyclers and steel mills.

Features: Heavy duty steel frame. Cast iron endplates. Class H insulation

50 Hertz
Motors
with Class F temperature rise. Precision brush holders. Constant force brush
springs. Double sealed ball bearings. Compound wound with drooping
voltage characteristics. DPFG enclosure. Weather resistant paint.
F-2 conduit box. CDMG generators have C-face and base mounting for

Motors & Controls


hydraulic pump or PTO mounting.

Inverter/Vector
Voltage Full Load Field Control
Ap’x.
Base NEMA D.C. Amperage Catalog List Mult. Rheostat
kW Shpg. Notes (a)
Speed Frame Number Price Sym.
Arm. Field Arm. Field Wgt. Ohms Amp Max.
5 2500 1810AT 230 230 21.7 0.61 DMG2305 6,285 N2 220 300 0.85 1, 3
7 1/2 2500 219AT 230 230 32.6 1.14 DMG2307 7,230 N2 262 150 1.6 1, 3
and Controls

219AT 230 230 43.5 0.72 DMG2310 8,013 N2 246 200 1.4 1, 3
DC Motors

10 2500
219ATC 230 230 43.5 0.72 CDMG2310 8,515 N2 250 200 1.4 1, 3
259AT 230 230 65 1.3 DMG2315 13,452 N2 429 200 1.82 1, 3
15 1750
259ATC 230 230 65 1.3 CDMG2315 13,943 N2 459 200 1.82 1, 3
288AT 230 230 87 1.8 DMG2320 14,727 N2 589 125 2.52 1, 3
20 1750
288ATC 230 230 87 1.8 CDMG2320 15,565 N2 609 125 2.52 1, 3
Dynamic Brakes

328AT 230 230 109 2.13 DMG2325 16,103 N2 849 100 3.0 1, 3
25 1750
Soft Start &

328ATC 230 230 109 2.13 CDMG2325 16,935 N2 878 100 3.0 1, 3
328AT 230 230 144 2.13 DMG2333 20,421 N2 831 100 3.0 1, 3
33 1750
328ATC 230 230 144 2.13 CDMG2333 21,246 N2 883 100 3.0 1, 3
40 1750 329AT 230 230 174 3.7 DMG2340 22,385 N2 910 50 5.2 1, 3
NOTE: Field control rheostat and meters are not included in price or available from Baldor.
(a) See notes on inside back flap and pages 5-6.
­281
DC Motors & Controls
HVAC Motors

Tach Mounting Kits and Cooling Blowers for DC Integral Hp Motors

Applications: Allows addition of DC, AC and digital tachometers to large


DC motors for closed-loop operation.
Farm Duty
Motors

Features: Tach mounting kits supply adapter, coupling, accessory shaft and
mounting hardware. Allows mounting to 8.5 inch accessory face on most
large DC motors.
Definite Purpose
Motors

Tach Mounting Kits for DC Integral Hp Motor Catalog No. Ending With “P”
Ap’x.
Tach Motor Motor Catalog List Mult.
Shpg.
Type Frame Enclosure Number Price Sym.
Wgt.
XPYII 180/360 DPFG, DPBV TKP1836XP 872 A8 1
Brake Motors

XPY, DPY 210/360 TEFC TKP2136XPT 872 A8 13


BTG1000 400 DPFG, DPBV TKP400XP 872 A8 3
500 DPFG, DPBV TKP500XP 872 A8 3
XC42 or 210/360 DPFG, DPBV TKP2136XC 1,218 A8 16
XC46 500 DPFG, DPBV TKP500XC 1,218 A8 7
180/360 DPFG, DPBV TKP1836ENC 664 A8 17
ENC00NV 400 DPFG, DPBV TKP400ENC 664 A8 16
200 & 575 Volt

ENCODER 500 DPFG, DPBV TKP500ENC 664 A8 17


Motors

210/360 DPFG, DPBV TKP2136NC 53 A8 3


NCS 400 DPFG, DPBV TKP400NC 53 A8 1
PANCAKE 500 DPFG, DPBV TKP500NC 53 A8 1
210/360 DPFG, DPBV TKP2136AC 53 A8 2
AC 400 DPFG, DPBV TKP400AC 53 A8 1
PANCAKE 500 DPFG, DPBV TKP500AC 53 A8 1
IEC Frame
Motors

Blower and Mounting Kits for DC Integral Hp Motor Catalog No. Ending With “P”
50 Hertz
Motors

Ap’x.
Motor Catalog Blower Blower List Mult.
Shpg.
Frame Number Power Size Price Sym.
Wgt.
Blower and Mounting Kit
180 FVB3180 1 PH LM 3 1,239 A8 18
Motors & Controls

210 FVB3210 3 PH LM 3 1,239 A8 22


Inverter/Vector

250 FVB3250 3 PH LM 3 1,239 A8 19


280 FVB4280 3 PH LM 4 1,513 A8 38
320 FVB6320 3 PH LM 6 1,766 A8 46
360-400 FVB6400 3 PH LM 6 1,933 A8 59
504-506 FVB8500 3 PH LM 8 2,286 A8 79
508-5012 FVB95010 (a) 3 PH LM 9 3,941 A8 171
Filter and Hardware for Above Blowers
and Controls
DC Motors

180, 210, 250 FLT3210-250 (b) - LM 3 593 A8 2


280 FLT4280 - LM 4 593 A8 9
320,360,400 FLT6320-400 - LM 6 593 A8 9
504-506 FLT8500 - LM 8 754 A8 9
NOTE: (a) Includes Blower and Filter. (b) Also used with FVB3180.
Dynamic Brakes
Soft Start &

­282
DC Motors & Controls

HVAC Motors
Tach Generators Applications: Speed feedback for controls (encoders also offer position
feedback).
DC, AC and Digital
Output Features: Ball bearing construction, standard mounting flanges and/or feet.

Farm Duty
Motors
Definite Purpose
Motors

Ap’x.
Generator Catalog List Mult.
Voltage Shpg.
Type Number Price Sym.
Wgt.
XPY Flange Mount (DC)
30AFL-O 50VDC BTG1000 409
466 DS 7

Brake Motors
XPYII 100VDC BTG100XPS 743
850 N5 2
XPYII 100VDC PTG100XPS 1,257
1099 N5 10
XPY 100VDC PTG100XP 1,210
1058 N5 3
XPY 50VDC BTG50XPS 850
743 N5 23
XPYII 50VDC PTG50XPS 1,257
1099 N5 8
XPY 50VDC PTG50XP 1,210
1058 N5 3

200 & 575 Volt


XPY Washdown Flange Mount (DC)

Motors
XPYII 100VDC PTGWD100XPS 1,338
1170 N5 9
XPYII 100VDC BTGWD100XPS 1,011
884 N5 2
XPYII 50VDC PTGWD50XPS 1,338
1170 N5 10
XPYII 50VDC Encoder Based Digital PY Flange Mount
BTGWD50XPS 1,011 N5 2
DPY 1024PPR Encoder Based
PTG1024LD (a) Digital PY Flange Mount
1380 N5 1
DPY 1024PPR Electrically
PTG1024LD (a) Isolated Encoder1,578 N5 1

IEC Frame
E-ACC 1024PPR Electrically
ENC00NV (a) (b) Isolated Encoder1501 E8 2

Motors
E-ACC 1024PPR Metric
ENC00NV Flange Mount (DC) 1,792
(a) (b) E8 2
XPY 60VDC Metric (c)
PTG60XP-M Flange Mount (DC) 1058 N5 8
XPYII
XPY 60VDC PTG60XPS-M
PTG60XP-M (c) (c) 1,210
1099 N5 5
XPYII 60VDC PTG60XPS-M Foot
(c) Mount (DC) 1,257 N5 5
XPYII
XPY 100VDC
60VDC BTG60XPS-M
PFTG100XP (c) 1058
850 N5 26
XPY 50VDC PFTG50XP Foot Mount (DC) 1058 N5 6

50 Hertz
XPY 100VDC Foot Mount with Face (DC) 1,210
PFTG100XP N5 6

Motors
XC42
XPY 100VDC
50VDC PFTG42100X
PFTG50XP 1,210
2081 N5 33
6
XC42 50VDC Foot Mount with Face (DC) 2127
PFTG4250XC N5 32
XC42
XC46 100VDC PFTG42100X
PFTG46100X 2,380
3659 N5 33
43
XC42
XC46 50VDC PFTG4250XC
PFTG4650XC 2,432
3659 N5 32
44
XC46 100VDC Pancake Mount (AC & DC) 4,184
PFTG46100X N5 43

Motors & Controls


Inverter/Vector
XC46
AC 45/90VAC
50VDC PTG4590AC
PFTG4650XC (d) ** 4,184
1017 N5 44
9
NCS 50VDC PTG50NCPancake
(d) **Mount (AC & DC) 1518 N5 8
AC 45/90VAC PTG4590AC (d) ** 1,163 N5 8
NCS 50VDC PTG50NC (d) ** 1,736 N5 8
NOTE: Flange mounted tachs require tach adapters shown on pages 282 & 284. XPY tachs have UL listing, file number E109527, CSA file number LR36841-5, XPYII
tachs are pending approval.
(a) See page 210 for cables.
and Controls

(b) Electrically isolated encoder & kit: Mounts to Fort Mill DC motors using appropriate adapter shown on page 282 may eliminate the need for EXB00801 isolated encoder
DC Motors

feedback board.
(c) Requires adapter for metric flange tach. Will not mount on adapters for PY flanges.
(d) Does not mount to TEFC. See catalog MN605 for details. Will only mount to DPFG and DPBV motors on pages 279 & 280 using adapters shown on page 282.
Dynamic Brakes
Soft Start &

­283
DC Motors & Controls
HVAC Motors

Field Conversion For PY Flange mounted BTG1000, XPY, XPYII and DPY
tachometers
Tach Mounting Kits
for Permanent Magnet Complete kits consisting of fan cover (except TK3300), shaft extension
coupling and tach adapter bracket with miscellaneous hardware. If you prefer,
and Shunt Wound Motor
Farm Duty

the conversion can be made by Baldor Mod Express. Tach kits will not work
Motors

with Explosion Proof Motors (CDPX or CDX). See PY flange mount tachs
shown on page 283.

Kit Ap’x.
Definite Purpose

Baldor List Mult.


Catalog Shpg.
Motor Type Price Sym.
Motors

Number Wgt.
3300P TK3300 168 A8 1
3400D/P TK3400 298 A8 4
3500D/P TK3500 314 A8 9
3600D TK3600 415 A8 5
Brake Motors

3600P TK3600PM 415 A8 3


7500D TK7500 429 A8 17
9100D TK9100 464 A8 23
200 & 575 Volt
Motors
IEC Frame
Motors
50 Hertz
Motors
Motors & Controls
Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­284
DC Motors & Controls

HVAC Motors
DC Drives Selection Chart
Single Phase DC Three Phase DC
Series 19H Series 20H FlexPak 3000
BC DC2 DC3 Non-Regen Regen Non-Regen & Regen

Farm Duty
Motors
Definite Purpose
Motors
Main Attributes
29 models to choose from Enhanced operating features Lowest cost single phase Digital DC Drive with standard armature voltage feedback Digital DC Drive; user
with extensive list of available including process signal DC family. Plate style and or built in encoder feedback capability. Many options friendly OIM; Quick Start
options to fit greatest range speed ref. and torque control enclosed models available. available include high resolution analog input and digital set up and diagnostics

Brake Motors
of applications models. Simple set up and output boards. menu.
operation.
Hp Range
1/100 thru 5 1/4 to 2 1/8 to 2 5 thru 300 1.5 to 600
Voltage Range
115/230 1-phase 115/230 1-phase 115/230 1-phase 230/460 3-phase 230/460 3-phase

200 & 575 Volt


Motors
Enclosure Selection
Chassis, NEMA 1, NEMA 4X Chassis, NEMA 4X, NEMA 12 Chassis, NEMA 1, NEMA 4X, Chassis Chassis, NEMA 1 (with kit);
NEMA 12 IP00, IP20
Speed Control
Armature voltage or Tach Armature voltage or Tach Armature voltage or Tach Armature voltage or Encoder feedback, standard Armature voltage or Tach

IEC Frame
Motors
Speed Regulation
1% of base speed, 1% of set 2% of base speed, 1% with Base speed, 1% or 0.1% 1% of base speed, 0.1% of set speed with encoder Base speed, 2% armature
speed with tach feedback tach feedback with tach feedback feedback feedback, 1% with analog
tach feedback, .01% with
encoder feedback.
Speed Range

50 Hertz
Motors
20:1 or 50:1 20:1 or 30:1 60:1 100:1 based on top speed and feedback type 100:1 based on top speed
and feedback type.
Communications Options
None None None RS-232 Serial, RS-422/485, Device Net, Modbus Plus, DeviceNet, ControlNet,
Profibus DP. Profibus DP, AutoMax,

Motors & Controls


Interbus-S

Inverter/Vector
Operator Interface
Local analog controls on Local analog controls on Local analog controls on Local keypad / display. 2 lines X 16 characters backlit Local OIM (operator
enclosed models; analog and enclosed models; analog and enclosed models; analog LCD. 12 key membrane w/tactile response. interface module), keypad
discrete remote control. discrete remote control. and discrete remote control. with multi-line LCD display;
remote mounting kit for
standard OIM; CS300 PC
software option
and Controls
DC Motors

Differentiating Feature
HP range available from OEM feature/benefits, Economical, Isolated analog High peak overload rating up to 300%. 15 preset speeds. Extensive option list
1/100 through 5. application flexibility. speed ref. signal input 9 assignable digital inputs. including: NEMA 1
models available without enclosure kit, AC line
need for option kits. disconnect kit, Blower
Motor Starter, DB, OIM
Dynamic Brakes
Soft Start &

Remote mounting kit.

­285
DC Motors & Controls
HVAC Motors

Fractional Horsepower 1/15 thru 1/4 115 VAC Single Phase 50/60 Hz.
DC Speed Controls for
Applications: Conveyors, machine tools and other applications requiring
PMDC Motors adjustable speed.
Farm Duty
Motors

Features: Simple DC motor control with built-in circuit breaker, center lock
reversing switch (center off), on/off switch, 7 foot SJO oil resistant cord, and
variable voltage transformer for manual speed adjustment. NEMA 1 enclosure
is standard. CSA list file # LR54532.
Definite Purpose
Motors

Max Catalog List Mult Ap’x Amp Input


Hp Number Price Sym. Shpg. Wgt. Capacity Voltage
1/15 BC110 490 E9 5 1.0 115VAC
1/8 BC115 523 E9 6 1.5 115VAC
1/4 BC130 666 E9 10 3.0 115VAC
Brake Motors

NEMA 1 Enclosed DC 1/100 thru 2 Hp 115/230 VAC Single Phase 50/60 Hz.
Controls for PMDC and
Applications: General purpose industrial use with permanent magnet or
Shunt Wound Motors
200 & 575 Volt

shunt wound DC motors.


Motors

Features: SCR controls have a free-wheeling diode and feature adjustable


accel, decel, current limit, IR comp, min. and max speed pots to match
applications. The anti-demag feature protects PM motors and helps protect
the SCR power bridge against direct shorts. The controls have US and
Canadian UL component recognition.
IEC Frame
Motors

A Plug-in Horsepower Resistor® and armature fuse must be ordered and


installed in BC138, BC139, BC140, BC140-FBR, BC141 and BC142.
BC140 ENCLOSED (NEMA 1)

Ap’x
Hp Catalog List Mult. Input
Shpg.
Range Number Price Sym. Voltage
Wgt. Lbs.
50 Hertz

1/100-1/3 BC138 194 E9 1 115


Motors

1/50-3/4 BC139 194 E9 1 230


1/100-2 (a) BC140 329 E9 3 115/230
1/100-2 (a) BC140-FBR 455 E9 3 115/230
NOTE: (a) 1 Hp at 115V and 2 Hp at 230V requires BC143 heatsink kit. See page 290 for features. FBR=Forward/Brake/Reverse.
Motors & Controls
Inverter/Vector

DC Control Accessories
Ap’x.
Catalog List Mult.
Description Shpg.
Number Price Sym.
Wgt.
and Controls
DC Motors

BC24-LF Ac Line Filter for use with CE Applications 66 E9 1


BC143 External Heatsink Kit (BC140, BC140-FBR, BC141, BC142, BC204) 63 E9 2
BC144 Forward-Brake-Reverse Switch Kit for BC140 110 E9 1
BC145 Signal Isolator Board 187 E9 1
BC146 Current Sensing Relay/Overload Protector 121 E9 1
BC147 Barrier Terminal Board (BC141 and BC142) 26 E9 1
Dynamic Brakes

BC148 Replacement Potentiometer Kit (5K ohm) 11 E9 1


Soft Start &

BC149 Knob and Dial Kit 12 E9 1


BC152 Barrier Terminal Board With Signal Isolator (BC141 and BC142) 172 E9 1
BC218 DIN-rail mounting kit for BC141, BC142 or BC204 31 E9 1
NOTE: BC24-LF is an AC line filter required for applications where CE is required if the control is not filtered elsewhere in the application. This filter may be used on most
115 or 230 VAC, single phase applications where CE is required.
­286
DC Motors & Controls

HVAC Motors
Chassis Mount DC 1/100 thru 1.5 Hp 115 VAC Single Phase 50/60 Hz.
Controls 1/50 thru 5 Hp 230 VAC Single Phase 50/60 Hz.

Applications: General purpose industrial use with permanent magnet or


shunt wound DC motors.

Farm Duty
Motors
Features: Chassis-mount SCR controls have a free-wheeling diode and
feature adjustable accel, decel, current limit, IR comp, min and max speed
pots to match applications. The anti-demag feature protects PM motors and
helps protect the SCR power bride against direct shorts. The controls have

Definite Purpose
BC141 / BC142 US and Canadian UL component recognition.

Motors
Ap’x.
Hp Catalog Description List Mult. Input
Shpg.
Range Number Input Voltage / Max. Hp Price Sym. Voltage
Wgt.
1/100-1 1/2 (a) BC141 Standard Model, single voltage 180 E9 1 115
BC141 with BC152 Signal Isolator and

Brake Motors
1/100-1 1/2 BC141-SIH 425 E9 2 115
BC143 Heatsink factory installed
1/100-3 (a) BC142 Standard Model, single voltage 180 E9 2 230
BC142 with BC152 Signal Isolator and
1/100 - 3 BC142-SIH 445 E9 2 115/230
BC143 Heatsink factory installed
1/100-1 1/2 (a)
BC142-5 Dual voltage, without fuse holders 180 E9 1 115/230
1/50-3

200 & 575 Volt


1/100 - 1 1/2 (a)
BC142-6 Standard Model, dual voltage 198 E9 1 115/230
1/50 - 3

Motors
1/100 - 1 1/2 BC142-6 with BC152 signal isolator board and
BC142-6-SIH 445 E9 1 115/230
1/50 - 3 BC143 heatsink factory installed
5 BC155 120V - 1 Hp, 230V - 2 Hp 588 E9 5 230
NOTE: Above controls include 5k speed potentiometer.
(a) 1-1.5 Hp at 115 Volts and 2-3 Hp at 230 Volts, requires BC143 Heatsink kit.
BC155 Includes integral heatsink. Please refer to page 291 for features.

IEC Frame
Motors
Plug-in Horsepower A Plug-in Horsepower Resistor® and armature fuse must be ordered and
Resistor and installed in BC138, BC139, BC140, BC140-FBR, BC141 and BC142.
Fuse Kit These should be selected based on the motor’s rated current. The price of
the Hp resistor and fuse is included in the BC138, BC139, BC140,

50 Hertz
Motors
BC140-FBR, BC141 and BC142 list price.
See selection below for catalog number.
Spare resistor kits are available for $9.00 list, E9 multiplier.

Motors & Controls


Inverter/Vector
Motor Hp Plug-In Hp
Catalog Ap’x DC DC Fuse Rating
Armature Voltage Resistor Resistance
Number Current (Amps) For Armature
90-130V 180V Value (Ohms)
1/100 1/50 1.0 BR1000 0.20 0.5
1/50 1/25 0.51 BR0510 0.30 0.5
and Controls
DC Motors

1/30 1/15 0.35 BR0350 0.33 0.5


1/20 1/10 0.25 BR0250 0.5 0.75
1/15 1/8 0.25 BR0251 0.8 1.0
1/12 1/6 0.18 BR0180 0.85 1.25
1/8 1/4 0.1 BR0100 1.3 2.0
1/6 1/3 0.1 BR0101 2.0 2.5
Dynamic Brakes

1/4 1/2 0.05 BR0050 2.5 4.0


Soft Start &

1/3 3/4 0.035 BR0035 3.3 5.0


1/2 1 0.025 BR0025 5.0 8.0
3/4 1 1/2 0.015 BR0015SP 7.5 12.0
1 (a) 2 (a) 0.01 BR0010SP 10 15.0
1 1/2 (a) 3 (a) 0.006 BR0006 15 25.0 (b)
NOTE: (a) External Heatsink required. (b) Also used with AC Line Fuse. For AC line fuse rating see manual. ­287
DC Motors & Controls
HVAC Motors

NEMA 4X DC 1/4 thru 2 Hp 115/230 VAC Single Phase 50/60 Hz.


Control 3 Hp 230 VAC Single Phase 50/60 Hz.
and Accessories Applications: Constant torque, new or replacement.
Farm Duty
Motors

Features: BC154, BCWD140 and BC160 are non-regen controls with reversal
by means of switching the armature leads (BCWD140 has a forward/brake/
reverse switch mounted). BC254 is a line regenerative SCR control that can
drive the motor to a timed stop. BC354 is a PWM control that provides low-
ripple DC power to the motor allowing more Hp when used with a 140 or 280
Definite Purpose

VDC motor. All offer a choice of armature or tachometer feedback and a speed
Motors

or torque mode. No Hp resistors are needed for these controls, current is jumper
selectable. BC154, BC160, BC254 and BC354 are painted black and come with
a start-stop switch. BCWD140 comes with white epoxy paint and also forward/
brake/reverse and run-jog switches. See pages 290-291 for features.
Brake Motors

Ap’x.
Hp Catalog Description List Mult. Input
Shpg.
Range Number Input Voltage / Max. Hp Price Sym. Voltage
Wgt.
NEMA 4X SCR (black)
BC154 Standard model - 120V - 1 Hp, 230V - 2 Hp 416 E9 5 115/230
BC154-P BC154 with POWER SWITCH instead of START/STOP SW. 416 E9 5 115/230
1/4-2 BC154-R BC154 with BC156 - FBR Switch factory installed 550 E9 5 115/230
200 & 575 Volt

BC154 with BC145 Signal Isolator Board and BC158


BC154-SI 670 E9 5 115/230
Motors

Auto/Man Switch kit factory installed


3 BC160 230V - 3 Hp 479 E9 3 230
NEMA 4X Washdown Duty SCR (white)
1/4-2 BCWD140 120V - 1 Hp, 230V - 2 Hp 557 E9 6 115/230
NEMA 4X Washdown Duty Line Regen SCR (black)
1/8-2 BC254 120V - 1 Hp, 230V - 2 Hp (a) 599 E9 5 115/230
IEC Frame
Motors

BC254-FBR BC254 with BC253 FWD-BRAKE-REV switch factory installed 622 E9 5 115/230
NEMA 4X Washdown Duty PWM DC (black) (b)
1/4-2 BC354 120V - 1 Hp, 230V - 2 Hp 645 E9 5 115/230
NOTE: (a) See page 289 for BC254 accessories.
(b) Output current is 7.5 amps; Output voltage is 140VDC for 115VAC input - 280VDC for 230VAC input. Motors designed for these voltages will give the best performance.
50 Hertz
Motors
Motors & Controls
Inverter/Vector

DC SCR NEMA 4X DC Control Accessories


Ap’x.
Catalog List Mult.
Description Shpg.
Number Price Sym.
Wgt.
BC153 Electronic Forward-Dynamic Brake-Reverse Kit for BC154, BC354 198 E9 1
BC156 Mechanical Forward-Dynamic Brake-Reverse Switch for BC154, BC354 128 E9 1
BC157
and Controls

Run/Jog switch for BC154 & BC160, BC354 23 E9 1


DC Motors

BC158 Auto/Manual Installation Kit for BC145 signal isolator for BC154, BC160, BC354 53 E9 1
BC159 AC Line Switch Kit for BC154, BCWD140, BC254, BC354 28 E9 1
BC145 Signal Isolator Board 187 E9 1
NOTE: BC159 AC Line Switch Kit is factory installed on BC154, BCWD140, BC354. Listed here as replacement or spare parts.
Dynamic Brakes
Soft Start &

­288
DC Motors & Controls

HVAC Motors
Line Regenerative 1/4 thru 3 Hp 115/230 VAC Single Phase 50/60 Hz.
DC Controls and 5 Hp 230 VAC Single Phase 50/60 Hz.
Accessories Applications: Frequent start/stop/reverse applications or where controlled
braking is required.

Farm Duty
Motors
Features: Single phase line regenerative open chassis control to operate
permanent magnet or wound field DC motors. These line regen controls are
ideal for applications with overhauling loads. In torque mode, it can be used
for tensioning applications. Several accessory boards are available to further

Definite Purpose
customize the control. Includes 5k speed potentiometer. Jumper selectable

Motors
current settings.

Ap’x.
Hp Catalog Description List Mult. Input
Shpg.
Range Number Input Voltage / Max. Hp Price Sym. Voltage
Wgt.

Brake Motors
Line Regen SCR
BC204 120V 1 Hp, 230V 2 Hp, Standard Model 336 E9 3
1/8-2 (a) BC204 with BC215 Bi-polar Signal Isolator 115/230
BC204-BPSI 434 E9 3
factory installed
1/4-2 BC200 120V 1 Hp, 230V 2 Hp 628 E9 4 115/230
1/4-3 BC201 120V 1-1/2 Hp, 230V 3 Hp 746 E9 1 115/230
5 BC203 230V 5Hp 939 E9 10 230

200 & 575 Volt


NEMA 4X Washdown Duty Line Regen SCR

Motors
BC254 120V - 1Hp, 230V - 2Hp Standard Model 599 E9 5 115/230
BC254 with Power On/Off switch instead of Start/
1/8-2
BC254-FBR Stop switch, and BC253. Forward-Brake-Reverse 622 E9 5 115/230
switch factory installed
NOTE: (a) 1 Hp at 115 volts and 2 Hp at 230 volts requires BC143 heatsink kit.

IEC Frame
Motors
Line Regenerative DC Control Accessories
Ap’x.
Catalog List Mult.
Description Shpg.

50 Hertz
Motors
Number Price Sym.
Wgt.
Accessories for BC200, BC201 and BC203
BC212 Bipolar signal isolator board 192 E9 1
Accessories for BC204
BC143 External Heatsink Kit 63 E9 2

Motors & Controls


BC215

Inverter/Vector
Bipolar signal isolator board 89 E9 3
BC216 Multispeed board for BC204 68 E9 1
BC218 DIN rail mounting kit 31 E9 1
Accessories for BC254
BC245 Bipolar signal isolator for BC254 189 E9 1
BC253 Forward-Stop-Brake-Reverse Switch for BC254 23 E9 1
BC258 Auto-manual Switch for BC254 53 E9 1
BC259 AC Line Switch for BC254 23 E9 5
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­289
DC Motors & Controls
HVAC Motors

NEMA Enclosed DC Control Specifications


Catalog Number
Features BC140 or
BC138 BC139 BC154 BC160 BCWD140
BC140-FBR
Farm Duty

Enclosure NEMA 1 NEMA 1 NEMA 1 NEMA 4X NEMA 4X NEMA 4X


Motors

Washdown
Control Type NEMA K NEMA K NEMA K NEMA K NEMA K NEMA K
AC Line Input 115 230 115 230 115 230 230 115 230
DC Armature Voltage Nominal 90 180 90 180 90 180 180 90 180
Shunt Field Power Supply
Definite Purpose

Voltage - DC 50/100 100/200 50/100 100/200 50/100 100/200 100/200 50/100 100/200
Rated Horsepower Range 1/100 - 1/3 1/50-3/4 1/100-1 1/50-2 1/50-1 1/25-2 3 1/50-1 1/25-2
Motors

External Heat Sink Not Not Not


(BC143) Required No No 1 Hp 2Hp Required Required Required
Speed Range (Motor May Be
20: 1 Constant Torque) 50:1 50:1 50:1 50:1 50:1 50:1
Adjustable Acceleration Time Yes Yes Yes Yes Yes Yes
Brake Motors

Adjustable Deceleration Time Yes Yes Yes Yes Yes Yes


Minimum Speed Adjustable Yes Yes Yes Yes Yes Yes
Maximum Speed Adjustable Yes Yes Yes Yes Yes Yes
Current Limit Adjustable Yes Yes Yes Yes Yes Yes
Adjustable Current Limit and Timed or Timed or Timed or
Trip Out Type No No No Non-Timed Non-Timed Non-Timed
200 & 575 Volt

Control Of Speed or Torque Speed Speed Speed Speed or Speed or Speed or


Motors

Torque Torque Torque


IR Compensation Adjustable Yes Yes Yes Yes Yes Yes
Tachometer Feedback Input No No No Yes Yes Yes
Plug-In Horsepower Resistor ® Required Required Required N/A N/A N/A
UL & cUL Listing, CE Yes Yes Yes Yes Yes Yes
AC Line Fuse Included Included Included External External External
DC Armature Fuse Included Included Included Not Supplied Not Supplied
IEC Frame
Motors

with with with with with


Hp Resistor Hp Resistor Hp Resistor Control External Control
Options
AC Line Switch Standard Standard Standard Opt - BC159 No Standard
Forward/Brake/Reverse Switch
Mechanical No No Opt-BC144 Opt-BC156 No Standard
50 Hertz
Motors

Electronic No No No Opt-BC153 No Opt-BC153


Run/Jog Switch No No No Opt-BC157 Opt-BC157 Standard
Input Signal Internal Internal External
Following Mode Capability Mount Mount Mount
Opt-BC145
Current (1-5, 4-20, 20-50mA) No No Opt-BC145 Opt-BC145 Opt-BC145
Opt-BC145
Motors & Controls

Voltage (0-25,0-120, VDC) Standard Standard Standard


Inverter/Vector

(0-5,0-10 VDC) (0-5,0-10 VDC) (0-5,0-10 VDC)


Electrical Connection To Control Standard Standard Standard Standard Standard Standard
Barrier Terminal Block
Current Sensing Relay/Overload No No Opt - BC146 Standard Standard Standard
Protector
AC Line Filter for CE Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­290
DC Motors & Controls

HVAC Motors
Chassis Mount DC Control Specifications
Catalog Number
Features
BC141 BC142 BC142-6 BC155 BC204 BC200 BC201 BC203
Enclosure Chassis Chassis Chassis Chassis Chassis Chassis Chassis Chassis
Control Type NEMA K NEMA K NEMA K NEMA K Regenerative Regenerative Regenerative Regenerative

Farm Duty
Motors
AC Line Input 115 230 115 230 230 115 230 115 230 115 230 230
DC Armature Voltage Nominal 90 180 90 180 180 90 180 90 180 90 180 180
Shunt Field Power Supply 50/100 50/100 50/100 50/100
100/200
Voltage - DC 50/100 100/200 100/200 100/200 100/200 100/200 100/200
Rated Horsepower Range 1/100-1.5 1/50-3 1/100-1 1/2 5 1/8-1 1/4-1 1/4-1-1/2
5

Definite Purpose
1/50-3 1/4-2 1/2-2 1/2-3
External Heat Sink 1/2 Hp-Up Not 90V-1Hp Not Not Not

Motors
(BC143) Required 1 Hp-Up 2 Hp-Up 1 Hp-Up Required 180V-2Hp Required Required Required
Speed Range (Motor may
50:1
be 20:1Constant Torque) 50:1 50:1 50:1 50:1 50:1 50:1 50:1
Adjustable Acceleration Yes Yes Yes Yes Yes Yes Yes Yes
Fwd & Rev Fwd & Rev Fwd & Rev Fwd & Rev

Brake Motors
Adjustable Deceleration Yes Yes Yes Yes Regen Regen Regen Regen
Min.. Speed Adjustable Yes Yes Yes Yes No No No No
Max. Speed Adjustable Yes Yes Yes Yes Yes Yes Yes Yes
Adjustable Current Non Non Non Non Non
Timed
Limit and Tripout Type Timed Timed Timed Timed Timed Timed Timed
Control of Speed or Speed Speed Speed Speed Speed or Speed or Speed or
Speed
Torque Torque Torque Torque Torque

200 & 575 Volt


IR Compensation Adjustment Yes Yes Yes Yes Yes Yes Yes Yes

Motors
Tachometer Feedback Input Yes Yes Yes Yes Yes Yes Yes Yes
Plug-in Horsepower Resistor® Required Required Required N/A N/A N/A N/A N/A
UL & cUL Listing, CE Yes Yes Yes Yes Yes Yes Yes Yes
AC Line Fuse Included Included Included External External Included Included External
Included Included Included Included Included Included
with Hp with Hp with Hp with Hp with Hp with Hp External

IEC Frame
Motors
DC Armature Fuse Resistor Resistor Resistor Resistor External Resistor Resistor
Options
Input Signal
Following Mode Capability No No
Current (1-5,4-20,20-50 mA) Opt-BC145 Opt-BC145 Opt-BC145 Opt-BC145 Std No No Std 0-±10VDC
Voltage (0-25, 0-120, VDC) Opt-BC145 Opt-BC145 Opt-BC145 Std 0-10 VDC Opt BC215 Std 0-±10 VDC Std 0-±10 VDC Opt-BC212

50 Hertz
Motors
0-25, 0-120, VDC) No No No No with BC214 Opt-BC212 Opt-BC212
Electrical Connection
To Control No
Push-On Quick Connects Standard Standard Standard No Standard No No Standard
Barrier Terminal Block Opt-BC147 Opt-BC147 Opt-BC147 Standard N/A Standard Standard

Motors & Controls


Current Sensing Relay/

Inverter/Vector
Standard
Overload Protector Opt-BC146 Opt-BC146 Opt-BC146 Opt-BC146 N/A Standard Standard
Regenerative Opt Opt Opt
Accel / Decel Board No No No No No
AC Line Filter for CE Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF Opt-BC24-LF and Controls
DC Motors
Dynamic Brakes
Soft Start &

­291
DC Motors & Controls
HVAC Motors

DC2 DC Drives for 1/4-2 Hp 115/230 VAC 1 Phase 50/60 Hz.


1/4 thru 2 Hp PMDC
Applications: General purpose industrial use with Permanent Magnet or Shunt
and Shunt Wound Wound DC Motors.
Motors
Farm Duty
Motors

Features: General purpose industrial use. Available in open chassis, plate style,
NEMA 12 or NEMA 4/4X. Operates from either local or remote operator controls for
added mounting flexibility, (Note: reversing drives are local control only). All models
have a single, surface mount design, printed circuit board. Jumper reconnection
for Line voltage, Horsepower, Feedback, “S” curve, and Zero speed. Adjustments
Definite Purpose

for Min and Max speed, Current Limit, IR drop Compensation, and Accel/Decel
Motors

rate. 20:1 constant torque speed range, 30:1 constant torque speed range with
tachometer feedback.
Brake Motors

1/4 - 1Hp @ 115 VAC 90 VDC Armature, 50 VDC Field (a)


1/2 - 2Hp @ 230 VAC 180 VDC Armature, 100 VDC Field (a)

Regulator Type Catalog Number List Price Mult. Sym. BC Series Alternate (b)(e)
Open Chassis, DC2 Series 40
200 & 575 Volt

Basic Regulator DC2-40U 357 VS3DC BC140 + BC143


Motors

Basic Regulator with Instrument Interface (b) DC2-42U 438 VS3DC BC140 + BC143 + BC145
Torque Regulator DC2-43U 400 VS3DC
Plate Controller, DC2 Series 50 (c)
Basic Regulator DC2-50U 297 VS3DC BC142-6 + BC143
Basic Regulator with Instrument Interface (b) DC2-52U 324 VS3DC BC142-6 + BC143 + BC152
IEC Frame

Torque Regulator with Instrument Interface (b) DC2-54U 324 VS3DC


Motors

NEMA 12 Enclosure with Operator Control, DC2 Series 70


Basic Regulator DC2-70U 405 VS3DC BC154
Basic Regulator with Reversing DC2-71U (d) 524 VS3DC BC154 + BC156 or order as BC154-R (f)
with BC156-FBR Switch factory installed
Basic Regulator with Instrument Interface (b) DC2-72U 550 VS3DC BC154 + BC145 + BC158 or order as BC154-SI (f)
with BC145, Signal Isolator Board, and BC158,
50 Hertz

Auto/Man Switch factory installed


Motors

Torque Regulator with Instrument Interface (b) DC2-74U 562 VS3DC BC154 + BC145 + BC158
Easy Clean NEMA 4/4X/12 Enclosure, DC2 Series 80 Without Operator Control
Basic Regulator with Run/Jog DC2-80U 405 VS3DC
Basic Regulator with Instrument Interface (b) DC2-82U 497 VS3DC
Motors & Controls

Easy Clean NEMA 4/4X/12 Enclosure, DC2 Series 90 With Operator Control
Inverter/Vector

Basic Regulator DC2-90U 427 VS3DC BC154


Basic Regulator with Run/Jog DC2-99U 486 VS3DC BC154 + BC157
Basic Regulator with Reversing DC2-91U (d) 551 VS3DC BC154 + BC156 or order as BC154-R (f)
with BC156-FBR, Switch factory installed
Basic Regulator with Instrument Interface (b) DC2-92U 551 VS3DC BC154 + BC145 + BC158 or order as BC154-SI (f)
with BC145, Signal Isolator Board and BC158 Auto/Man
Switch factory installed
and Controls
DC Motors

Basic Regulator with Reversing and Run/Jog DC2-98U (d) 594 VS3DC BC154 + BC156 + BC157
NOTE: Conduit hole plugs are standard on NEMA 12K designs. Conduit hubs are standard on NEMA 4/12 designs only.
Conduit hubs for either design can be ordered through Renewal Parts by referencing Reliance Part Number 608826-2A.
(a) Jumper selection for 115VAC / 90 VDC or 230 VAC / 180 VDC.
(b) Instrument Interface units also provide auxiliary control relay contact rated 0.6 Amps @ 125 VAC for customer use. Aux. relay not available on BC Series Signal Isolation
Option Boards.
Dynamic Brakes

(c) DC2 Series 50 Drive must be mounted to a metal surface 18” by 18” to meet 1hp @115 VAC and 2HP @ 230 VAC or an optional heat sink (HS1-50) can be purchased.
Soft Start &

(d) Switch reversing DC2 models include as standard an installed line fuse.
(e) Review dimensions and applications I/O functionality for complete compatibility. Contact your local district office for assistance.
(f) Catalog number indicates option kits factory installed for functional equivalent drive.
A transformer is mandatory for tachometer feedback operation using the Type RE-020 20.8 VDC/1000 RPM tachometer (Model Number R20E8000). The Type RE-007
(Model Number R07E1210) fully-isolated 7 VDC/1000 tachometer does not require an isolation transformer. Consult Instruction Manual D2-3231 for other recommended and
mandatory use of isolation transformers.

­292
DC Motors & Controls

HVAC Motors
DC2 Accessories
Catalog Number Description List Price Mult. Sym.
HS1-50 External Heatsink Kit for DC2-50 Series 108 VS3DC

Farm Duty
Motors
Customer Installed Fuse Kits

Definite Purpose
The DC2 Drives are not supplied with line fuses. If needed, order the model number Fuse Kit below to match the DC2

Motors
drive selected.
Drive Style DC2-Series Catalog Number List Price Mult. Sym.
Open Chassis 40 F1DC2000 52 VS3DC
Plate Chassis 50 F2DC2000 108 VS3DC

Brake Motors
NEMA 12K 70 F2DC2000 108 VS3DC
NEMA 4/12 80, 90 F2DC2000 108 VS3DC

200 & 575 Volt


Mounting Dimensions

Motors
Outside Mounting
Drive Style Height Width Depth Height Width
Inches (mm) Inches (mm) Inches (mm) Inches (mm) Inches (mm)
Enclosed
10.125 (260) 5.0 (128) 5.5 (141) 9.625 (247) 5.0 (128)
DC2 Series 70, 80, and 90

IEC Frame
Motors
Open Chassis
7.875 (200) 5.0 (128) 4.875 (125) 7.375 (188) 5.0 (128)
DC2 Series 40
Plate Style, Open Chassis
6.25 (159) 6.0 (152) 2.5 (64) 6.25 (159) 6.0 (152)
DC2 Series 50

50 Hertz
Motors
DC2 Drive Ratings
AC Input Voltage Rated AC DC Armature Rated Armature Available Field Rated Field
Motor HP Input KVA
(Volts AC) Line Amps* Voltage Current (Amps) Voltage Current (Amps)
115 3.1 0.36 90 2.5 50 2

Motors & Controls


1/4

Inverter/Vector
– – – – – – –
115 4.2 0.48 90 3.7 50 2
1/3
– – – – – – –
115 6.2 0.71 90 5 50 2
1/2
230 3.1 0.71 180 2.5 100 2
115 9.4 1 90 7.5 50 2
and Controls
DC Motors

3/4
230 4.7 1 180 3.7 100 2
115 12.5 1.4 90 10 50 2
1**
230 6.2 1.4 180 5 100 2
– – – – – – –
1 1/2
Dynamic Brakes

230 9.4 2.2 180 7.5 100 2


Soft Start &

– – – – – – –
2**
230 12.5 2.9 180 10 100 2
NOTE: * Includes motor field current
** DC2 Series 50 designs must be mounted to a metal plate heatsink, 18" x 18", to meet 1 Hp @ 115 VAC and 2 Hp at 230 VAC,
or an optional heat sink (HS1-50) may be purchased.
­293
DC Motors & Controls
HVAC Motors

DC3 DC Drives 115/230 VAC 1 Phase 50/60 Hz.


Fractional to 2HP
Applications: General purpose industrial use with Permanent Magnet or Shunt
for Non-Regen and Wound DC Motors.
Regen Applications
Farm Duty
Motors

Features: DC3 drives are available in plate style, NEMA 1 or NEMA 4X/12.
Non-Regen and Regen types available to fill many applications. Every DC3
product carries UL, cUL, and CE certification labels. Plate drives are designed for
mounting and integration into cabinets/enclosures. Plate models also include a
10K ohm speed pot for customer use.
Definite Purpose
Motors

Standard Specifications:
• AC line voltage variation – ±10% of selected input.
• AC line input frequency variation – 48 to 62 Hz.
• Output voltage – 0 to 90 VDC @ 115 VAC input, and 0 to 180 VDC @ 230 VAC
input.
Brake Motors

• Overload Capacity – 150% for 1 minute.


• Ambient temperature – -10°C to 55°C plate style. -10°C to 45°C enclosed.
• Elevation – 1000 meters without derating. (Derate 1% for every 90 meters
above 1000 m)

DC3N Non-Regenerative DC Drives


200 & 575 Volt

1/8 - 1Hp @ 115 VAC, 1-Ph, 50/60 Hz, 90 VDC Armature


Motors

1/4 - 2Hp @ 230 VAC, 1-Ph, 50/60 Hz, 180 VDC Armature
“Non-Isolated” Controller Selection – DC3N Chassis Model – 115/230 VAC, 1 Phase, 50/60 Hz
Hp – Rating
For the Operation of Permanent Magnet DC Motors Only
Catalog Number
115 VAC 230 VAC Chassis Rated AC Input DC Armature Rated Armature List Mult. BC Series
IEC Frame

Input Input Type Line (Amps) KVA Voltage Current (Amps) Price Sym. Alternate (a)
Motors

1/8 to 1/2 — Plate 4.5 to 7.8 0.5 to 0.9 90 2.7 to 5.0


1/2 to 1.0 — Plate 7.8 to 13 0.9 to 1.5 90 5.0 to 10*
DC3N-12D-00-010-AN 160 VS3DC BC142-5 (b)
— 1/2 to 1.0 Plate 2.6 to 7.0 0.6 to 1.6 180 1.4 to 5.0
— 1.0 to 2.0 Plate 7.0 to 12 1.6 to 2.8 180 5.0 to 9.2 *
NOTE: * Requires addition of Heatsink Kit Option: DC3N-HS-00 List Price: $98.00.
External isolated reference source, 90 VDC Armature: 0-1.4 VDC reference and 180 VDC: 0-2.8 VDC reference.
50 Hertz
Motors

Instruction manual D2-3451


(a) Review dimensions and application I/O functionality for complete compatibility. Contact your local district office for assistance.
(b) BC143 Heatsink option required for 1 Hp @ 115 VAC or 2 Hp @ 230 VAC rating.
Motors & Controls
Inverter/Vector

DC3N Plate Style Overall Dimensions


Height Width Length
Inches (mm) Inches (mm) Inches (mm)
1.60 (41) 4.30 (109) 3.58 (91)
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­294
DC Motors & Controls

HVAC Motors
DC3N Non-Regenerative DC Drives

Farm Duty
Motors
Definite Purpose
Motors
1/8 - 1Hp @ 115 VAC, 1-Ph, 50/60 Hz, 90 VDC Armature
1/4 - 2Hp @ 230 VAC, 1-Ph, 50/60 Hz, 180 VDC Armature
“Non-Isolated” Controller Selection – DC3N Enclosed Models – 115/230 VAC, 1 Phase, 50/60 Hz
Hp Rating
For the Operation of Permanent Magnet DC Motors Only

Brake Motors
Catalog Number
115 VAC 230 VAC Enclosure Rated AC Input DC Armature Rated Armature List Mult. BC Series
Input Input Type Line (Amps) KVA Voltage Current (Amps) Price Sym. Alternate (a)
1/8 to 1/2 — NEMA 1 4.5 to 7.8 0.5 to 0.9 90 2.7 to 5.0
1/2 to 1.0 — NEMA 1 7.8 to 13 0.9 to 1.5 90 5.0 to 10 **
DC3N-12D-01-010-AN 250 BC140 + BC143 (b)
— 1/2 to 1.0 NEMA 1 2.6 to 7.0 0.6 to 1.6 180 1.4 to 5.0
— 1.0 to 2.0 NEMA 1 7.0 to 12 1.6 to 2.8 180 5.0 to 9.2 **

200 & 575 Volt


1/8 to 1/2 — NEMA 4X/12 4.5 to 7.8 0.5 to 0.9 90 2.7 to 5.0 VS3DC

Motors
BC154 or order
1/2 to 1.0 — NEMA 4X/12 7.8 to 13 0.9 to 1.5 90 5.0 to 10 as BC 154-P (c)
with Power
— 1/2 to 1.0 DC3N-12D-4X-010-AN NEMA 4X/12 2.6 to 7.0 0.6 to 1.6 180 1.4 to 5.0 360
On/Off switch factory
installed in place of
— 1.0 to 2.0 NEMA 4X/12 7.0 to 12 1.6 to 2.8 180 5.0 to 9.2
Start/Stop switch
NOTE: ** Requires addition of Heatsink Kit Option: DC3N-HS-01 List Price: $124.00

IEC Frame
Motors
External isolated reference source, 90 VDC Armature: 0-1.4 VDC reference and 180 VDC: 0-2.8 VDC reference
Instruction manual D2-3451
(a) Review dimensions and application I/O functionality for complete compatibility. Contact your local district office for assistance.
(b) BC143 Heatsink option required for 1 Hp @ 115 VAC or 2 Hp @ 230 VAC rating.
(c) Catalog number indicates option kits factory installed for functional equivalence.

50 Hertz
Motors
DC3N Non-isolated Enclosed Style Overall Dimensions
Overall

Motors & Controls


Inverter/Vector
Enclosure Style Height Width Depth
Inches (mm) Inches (mm) Inches (mm)
NEMA 1 8.00 (203) 6.00 (152) 3.46 (88)
NEMA 4X/12 8.20 (208) 6.90 (175) 4.50 (114)
Height Width Length
Heatsink
Inches (mm) Inches (mm) Inches (mm)
and Controls

DC3N-HS-00 1.0 (25) 4.40 (112) 6.90 (175)


DC Motors

DC3N-HS-01 1.0 (25) 7.78 (198) 6.90 (175)


Dynamic Brakes
Soft Start &

­295
DC Motors & Controls
HVAC Motors

DC3N Non-Regenerative DC Drives


Farm Duty
Motors
Definite Purpose
Motors

1/8 - 1Hp @ 115 VAC, 1-Ph, 50/60 Hz, 90 VDC Armature


1/4 - 2Hp @ 230 VAC, 1-Ph, 50/60 Hz, 180 VDC Armature
Brake Motors

“Isolated” Controller selection - DC3N Chassis and Enclosed- 115/230 VAC, 1 Phase, 50/60 Hz
Hp Rating
For the Operation of Permanent Magnet and Shunt wound DC Motors
Catalog Number
115 VAC 230 VAC Enclosure Rated AC DC Armature Rated Armature Motor Field List Mult. BC Series
Input Input Type Line (Amps) Voltage Current (Amps) Voltage Price Sym. Alternate (a)
1/4 to 1 — Plate 4.5 to 13 90 2.7 to 10 50/100 BC142 + BC152 + BC143 (b) or
200 & 575 Volt

order as BC141-SIH (c), (115VAC


Motors

input) or BC142-SIH (c), (230VAC


DC3N-12D-00-010-AI 356
— 1/2 to 2 Plate 3.7 to 12 180 2.5 to 9.2 100/200 input) with BC152, Signal Isolator
with Barrier Terminal Board and
VS3DC BC143 Heatsink factory installed
1/4 to 1 — NEMA 4X/12 4.5 to 13 90 2.7 to 10 50/100 BC154 + BC145 + BC158 or order
as BC154-SI (c) with BC145 Signal
DC3N-12D-4X-010-AI 529
— 1/2 to 2 NEMA 4X/12 3.7 to 12 180 2.5 to 9.2 100/200 Isolator Board and BC158 Auto/
IEC Frame
Motors

Man switch factory installed


NOTE: Instruction manual D2-3452
(a) Review dimensions and application I/O functionality for complete compatibility. Contact your local district office for assistance.
(b) BC143 Heatsink option required for 1 Hp @ 115 VAC or 2 Hp @ 230 VAC rating.
(c) Catalog number indicates option kits factory installed for functional equivalence.
50 Hertz
Motors

DC3N “isolated” Plate and Enclosed Style Overall Dimensions


Overall
Enclosure Style Height Width Depth
Inches (mm) Inches (mm) Inches (mm)
Motors & Controls
Inverter/Vector

Plate 4.46 (113) 6.90 (175.26) 1.80 (46)


NEMA 4X/12 10.2 (260) 6.90 (175.26) 5.51 (140)
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­296
DC Motors & Controls

HVAC Motors
DC3R Regenerative DC Drives

Farm Duty
Motors
Definite Purpose
Motors
1/4 - 1Hp @ 115 VAC, 1-Ph, 50/60 Hz, 90 VDC Armature
1/2 - 2Hp @ 230 VAC, 1-Ph, 50/60 Hz, 180 VDC Armature
“Non-Isolated” Controller selection - DC3R Chassis model - 115/230 VAC, 1 Phase, 50/60 Hz
Hp Rating
For the Operation of Permanent Magnet and Shunt wound DC Motors

Brake Motors
Catalog Number
115 VAC 230 VAC Chassis Rated AC DC Armature Rated Armature Motor Field List Mult. BC Series
Input Input Type Line (Amps) Voltage Current (Amps) Voltage Price Sym. Alternate (a)
1/4 to 1/2 — Plate 4.2 to 7.5 90 2.7 to 5.0 50/100
1/2 to 1.0 — Plate 7.5 to 12.1 90 5.0 to 10 *** 50/100
DC3R-12D-00-010-AN 398 VS3DC BC204 (b)
— 1/2 to 1.0 Plate 3.8 to 6.7 180 2.5 to 5.0 100/200
— 1.0 to 2.0 Plate 6.7 to 11.7 180 5.0 to 9.2*** 100/200

200 & 575 Volt


Hp Rating Catalog Number “Isolated” Controller selection - DC3R Chassis model - 115/230 VAC, 1 Phase, 50/60 Hz

Motors
1/4 to 1/2 — Plate 4.2 to 7.5 90 2.7 to 5.0 50/100
BC204 + BC215 + BC143 (b)
1/2 to 1.0 — Plate 7.5 to 12.1 90 5.0 to 10*** 50/100 or order as BC204-BPSI (c)
DC3R-12D-00-010-AI 521 VS3DC
— 1/2 to 1.0 Plate 3.8 to 6.7 180 2.5 to 5.0 100/200 with BC215 Bi-polar Signal
Isolator
— 1.0 to 2.0 Plate 6.7 to 11.7 180 5.0 to 9.2*** 100/200
NOTE: ***Requires addition of Heatsink Kit Option DC3R-HS-00. List Price, $149.00

IEC Frame
Motors
Drive instruction manual D2-3453
DC3R Isolation Board Option instruction manual D2-3454
(a) Review dimensions and application I/O functionality for complete compatibility. Contact your local district office for assistance.
(b) BC143 Heatsink option required for 1 Hp @ 115 VAC or 2 Hp VAC rating.
(c) Catalog number indicates option kits factory installed for functional equivalence.

50 Hertz
Motors
DC3R “Non-isolated” and “isolated” Plate Style Overall Dimensions
Height Width Length
Style
Inches (mm) Inches (mm) Inches (mm)

Motors & Controls


Non-isolated 1.86 (47) 4.75 (120) 8.90 (226)

Inverter/Vector
Isolated 3.12 (78) 4.75 (120) 8.90 (226)
Heatsink
DC3R-HS-00 1.0 (25) 6.9 (175) 9.78 (248)
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­297
DC Motors & Controls
HVAC Motors

DC3R Regenerative DC Drives


Farm Duty
Motors
Definite Purpose

1/4 - 1Hp @ 115 VAC, 1-Ph, 50/60 Hz, 90 VDC Armature


Motors

1/2 - 2Hp @ 230 VAC, 1-Ph, 50/60 Hz, 180 VDC Armature
“Non-Isolated” Controller selection - DC3R Enclosed - 115/230 VAC, 1 Phase, 50/60 Hz
Hp Rating
For the Operation of Permanent Magnet and Shunt wound DC Motors
Catalog Number
115 VAC 230 VAC Enclosure Rated AC DC Armature Rated Armature Motor Field List Mult. BC Series
Input Input Type Line (Amps) Voltage Current (Amps) Voltage Price Sym. Alternate (a)
Brake Motors

1/4 to 1.0 — NEMA 4X/12 4.2 to 12.1 90 2.7 to 10 50/100 BC254 + BC253 or order
as BC254-FBR (b) with
DC3R-12D-4X-010-AN 675 VS3DC
— 1/2 to 2.0 NEMA 4X/12 3.8 TO 11.7 180 2.5 TO 9.2 100/200 BC253 FWD-STOP-REV
switch factory installed
NOTES: Instruction manual D2-3453
(a) Review dimensions and application I/O functionality for complete compatibility. Contact your local district office for assistance.
(b) Catalog number indicates option kits factory installed for functional equivalence.
200 & 575 Volt
Motors

DC3R Enclosed Style NEMA 4X/12 Overall Dimensions


Height Width Depth
Inches (mm) Inches (mm) Inches (mm)
10.2 (260) 6.90 (175.26) 5.51 (140)
IEC Frame

DC3R Regenerative DC Drives


Motors
50 Hertz
Motors
Motors & Controls

1/4 - 1Hp @ 115 VAC, 1-Ph, 50/60 Hz, 90 VDC Armature


Inverter/Vector

1/2 - 2Hp @ 230 VAC, 1-Ph, 50/60 Hz, 180 VDC Armature
“Non-Isolated” Controller selection - DC3R Chassis model - 115/230 VAC, 1 Phase, 50/60 Hz
Hp Rating
For the Operation of Permanent Magnet and Shunt wound DC Motors
Catalog Number
115 VAC 230 VAC Enclosure Rated AC DC Armature Rated Armature Motor Field List Mult.
Input Input Type Line (Amps) Voltage Current (Amps) Voltage Price Sym.
and Controls

1/4 to 1/2 — NEMA 4X/12 4.2 to 7.5 90 2.7 to 5.0 50/100


DC Motors

1/2 to 1.0 — NEMA 4X/12 7.5 to 12.1 90 5.0 to 10 50/100


DC3R-12D-4X-010-DN 855 VS3DC
— 1/2 to 1.0 NEMA 4X/12 3.8 to 6.7 180 2.5 to 5.0 100/200
— 1.0 to 2.0 NEMA 4X/12 6.7 to 11.7 180 5.0 to 9.2 100/200
NOTES: Instruction manual D2-3455
Dynamic Brakes
Soft Start &

DC3RD Enclosed Style NEMA 4X/12 Overall Dimensions


Height Width Depth
Inches (mm) Inches (mm) Inches (mm)
10.2 (260) 6.90 (175) 5.50 (140)
­298
DC Motors & Controls

HVAC Motors
Series 19H Digital 5 thru 75Hp 180-264 VAC - 50/60 Hz
DC Controls 5 thru 300 Hp 340-528 VAC - 50/60 Hz

Applications: Constant torque applications. New installations, replacements


and original equipment manufacturers (OEM).

Farm Duty
Motors
Features: Chassis mounting, built-in armature or encoder feedback, high
peak currents.

Definite Purpose
Motors
Design Specifications Operator Keypad Environmental and Protective Features
• Three phase, full wave SCR • Digital Speed Control Operating Conditions • Control Input over and under voltage
armature control • Forward/Reverse Command • Input Frequency - 50 or 60 Hz ± 5% • Encoder, tach or resolver loss
• High peak overload, 250-300% • Motor RUN and JOG • Service factor - 1.0 • Torque proving
(depending on rating) • Local/Remote Key • Duty - continuous • Selectable manual or automatic
• Selectable operating modes: Keypad; • Stop Command (coast or external • Humidity - 90% max RH restart at power loss

Brake Motors
Standard Run,15 Speed, Bipolar speed/ DB to stop) non-condensing • Digital display for fault conditions
torque; Serial; Process follower mode. • 32 Character alpha-numeric display • Altitude - 3300 feet max
• Analog meter outputs • Remote mount to 100 feet without derate Motor Feedback
• Buffered encoder output from control • 1024 PPR standard (with quadrature)
• 9 isolated inputs • NEMA 4X enclosure on keypad • Power output: +5VDC, 300 mA max
• Chassis mounting • Max frequency: 1 MHz
• Optional feedback: tachometer or
resolver through expansion board

200 & 575 Volt


Output

Motors
Voltage DC - 0-1.3 times VAC input
Ratings
Input Frequency 50 or 60 Hz ± 5%
Ratings Voltage 200-240 VAC ± 10%; 380-480 VAC ± 10%
Phase Three phase
Control Impedance 5% maximum
Spec. Control Method Full wave-uni-directional DC control, NEMA type C

IEC Frame
Speed Setting 0-5VDC, 0-10VDC, 4-20 mA, digital via keypad, optional RS232/422/485

Motors
Accel/Decel 0-3600 seconds (decel-coast or controlled by external DB resistors) - no S-curve decel
Minimum Speed 0-maximum speed
Maximum Speed 0-5000 RPM
Motor Matching Automatic tuning to motor with manual override
Field Power Type Voltage limited, current regulated full wave single phase
Supply Voltage 0 to 10-85% of AC line Input in DC volts

50 Hertz
Motors
Current 0.1-15 Amps maximum-standard, 0.1-40 amps maximum-optional
Field Economy Level OFF, 25-100%
Field Forcing Level 100-125% (hoist modes only)
Motor Feedback Type Armature or incremental encoder coupled to motor shaft
Feedback Pulses/Rev 60-65535 selectable, 1024 standard

Motors & Controls


Voltage Output 2 channel in quadrature, 5VDC differential

Inverter/Vector
Marker Pulse Required for position orientation
Power Input 5VDC, 300 mA maximum
Maximum Frequency 1 MHz
Optional Feedback Tachometer or resolver via expansion board
Protective Control Trip Missing control power, over current armature over voltage, motor overspeed over temperature
Functions (motor & control), field loss, encoder tach or resolver loss, phase loss, motor overload and overcurrent
Fusing Standard input line, armature and field power supply fuses
and Controls
DC Motors

External Output LED indicator for trip conditions, 4 assignable logic outputs - 30VDC Max, 2 assignable analog
outputs 0-5VDC
LCD Display Running Motor RPM, output current, voltage (selectable)
Setting Parameter values for setup and review
Trip Separate message for each trip, last 31 trips retained in memory
Ambient Temperature 0-40°C for UL listing
Dynamic Brakes

Conditions Cooling Forced air included when required


Soft Start &

NOTE: Use of DC tach for feedback requires DC Tachometer Interface Board, catalog number EXB006A01. Other expansion boards are available, see pages 253-254.

­299
DC Motors & Controls
HVAC Motors

Series 19H Digital DC Controls continued…


Armature Output Current Chassis
Hp Input Volt Catalog Number List Price Mult. Sym.
Amps Cont Amps Peak Size
230 Volt Input - 240 VDC Output
Farm Duty

5 230 20 40 BC19H205-CO 5,005 E1 A


Motors

10 230 40 80 BC19H210-CO 5,005 E1 A


15 230 60 120 BC19H215-CO 5,378 E1 A
20 230 75 150 BC19H220-CO 5,814 E1 B
25 230 100 200 BC19H225-CO 6,124 E1 B
40 230 140 280 BC19H240-CO 7,853 E1 C
Definite Purpose

50 230 180 360 BC19H250-CO 8,444 E1 C


Motors

60 230 210 420 BC19H260-CO 9,330 E1 C


75 230 270 540 BC19H275-CO 10,117 E1 C
460 Volt Input - 500 VDC Output
10 460 20 40 BC19H410-CO 5,097 E1 A
20 460 40 80 BC19H420-CO 5,097 E1 A
30 460 60 120 BC19H430-CO 5,503 E1 A
Brake Motors

40 460 75 150 BC19H440-CO 5,950 E1 B


50 460 100 200 BC19H450-CO 6,262 E1 B
75 460 140 280 BC19H475-CO 8,257 E1 C
100 460 180 360 BC19H4100-CO 8,818 E1 C
125 460 210 419 BC19H4125-CO 9,701 E1 C
150 460 270 540 BC19H4150-CO 10,502 E1 C
200 460 350 875 BC19H4200-CO 12,876 E1 D
200 & 575 Volt

300 460 500 1000 BC19H4300-CO 17,256 E1 D


Motors

OPTIONS: See pages 253-254 for optional Expansion Boards including Tachometer Feedback, RS-232, RS-422, RS-485, Resolver, Interface, etc.
40 Amp field power supply. FPS40BC1920
IEC Frame
Motors
50 Hertz

Dimensions in/(mm)
Motors

Outside Mounting Ap'x


Size Hp
Height Width Depth Height Width Shpg. Wgt.
A ALL 20.60/(523.2) 11.00/(279.4) 9.87/(250.7) 18.00/(457.2) 10.25/(260.4) 39
B 230V ALL 25.70/(652.8) 11.00/(279.4) 9.84/(249.9) 23.87/(606.3) 10.25/(260.4) 67
Motors & Controls
Inverter/Vector

B 460V ALL 26.75/(679.5) 11.00/(279.4) 9.84/(249.9) 24.94/(633.5) 10.25/(260.4) 69


C 230V 40-60 26.50/(673.1) 11.75/(298.5) 10.63/(270.0) 23.90/(607.0) 10.25/(260.4) 80
C 460V 75-100 27.25/(692.2) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 84
C 230V 75 33.00/(838.2) 11.75/(298.5) 10.63/(270.0) 23.90/(607.6) 10.25/(260.4) 94
C 460V 125-200 33.75/(857.3) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 97
D ALL 43.80/(1112.5) 16.87/(428.5) 12.43/(315.7) 39.25/(997.0) 13.75/(349.3) 272
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­300
DC Motors & Controls

HVAC Motors
Series 20H Line 5 thru 75Hp 180-264 VAC - 50/60 Hz
Regenerative Digital 5 thru 300 Hp 340-528 VAC - 50/60 Hz
DC Controls Applications: Constant torque applications. New installations, replacements
and original equipment manufacturers (OEM).

Farm Duty
Motors
Features: Chassis mounting, built-in armature or encoder feedback. High
peak current.

Definite Purpose
Motors
Design Specifications Operator Keypad Environmental and Protective Features
• Three phase, full wave, four quadrant • Digital Speed Control Operating Conditions • Torque proving
SCR armature control. • Forward/Reverse Command • Input frequency - 50 or 60Hz ±5% • Selectable manual or automatic
• Peak overload capacity of 250-300% • Motor RUN and JOG • Service factor - 1.0 restart at power loss
(depending on rating) • Local/Remote Key • Duty - continuous • Digital display for fault conditions
• Selectable operating modes: Keypad, • Stop Command • Humidity - 90% max RH

Brake Motors
Standard Run, 15 Speed, Bipolar • 32 Character alpha-numeric non-condensing Motor Feedback
speed/torque, Serial, Bipolar Hoist, display • Altitude - 3300 feet max • Power output: +5VDC, 300 mA max
7 Speed Hoist, process follower • Remote mount to 100 feet from without derate • Positioning: Buffered encoder pulse
• Motor shaft orient to encoder marker control train output for position loop control
or external switch closure (encoder • NEMA 4X enclosure on keypad • Optional feedback: tachometer or
feedback) resolver through expansion board
• 15 preset speeds (7 in Hoist Mode.)

Output

200 & 575 Volt


Voltage DC 0-1.13 times VAC input
Ratings

Motors
Input Frequency 50 or 60 Hz ± 5%
Ratings Voltage 200-240 VAC ± 10%; 380-480 VAC ± 10%
Phase Three phase
Control Impedance 5% maximum
Spec. Control Method Full wave-bi-directional regenerative DC control, NEMA type C
Speed Setting ±5VDC, 0-5VDC, ±10VDC, 0-10VDC, 4-20 mA, digital via keypad, optional RS232/422/485

IEC Frame
Motors
Accel/Decel 0-3600 seconds or s-curve
Minimum Speed 0-maximum speed
Maximum Speed 0-5000 RPM
Motor Matching Automatic tuning to motor with manual override
Field Power Type Voltage limited, current regulated full wave single phase
Supply Voltage 0 to 10-85% of AC line Input in DC volts
Current 0.1-15 Amps maximum-standard, 0.1-40 amps maximum-optional

50 Hertz
Motors
Field Economy Level OFF, 25-100%
Field Forcing Level 100-125% (hoist modes only)
Motor Feedback Type Armature or incremental encoder coupled to motor shaft
Feedback Pulses/Rev 60-65535 selectable, 1024 standard
Voltage Output 2 channel in quadrature, 5VDC differential

Motors & Controls


Marker Pulse Required for position orientation

Inverter/Vector
Power Input 5VDC, 300 mA maximum
Maximum Frequency 1 MHz
Positioning Optional buffered encoder pulse train output for position loop controller
Optional Feedback Tachometer or resolver via expansion board
Protective Control Trip Missing control power, over current armature over voltage, motor overspeed over temperature
Functions (motor & control), field loss, encoder tach or resolver loss, phase loss, motor overload and overcurrent
Fusing Standard input line, armature and field power supply fuses
and Controls
DC Motors

External Output LED indicator for trip conditions, 4 assignable logic outputs - 30VDC Max, 2 assignable analog
outputs 0-5VDC
LCD Display Running Motor RPM, output current, voltage (selectable)
Setting Parameter values for setup and review
Trip Separate message for each trip, last 31 trips retained in memory
Ambient Temperature 0-40°C for UL listing
Dynamic Brakes
Soft Start &

Conditions Cooling Forced air included when required


NOTE: Use of DC tach for feedback requires DC Tachometer Interface Board, catalog number EXB006A01. Other expansion boards are available, see pages 253-254.

­301
DC Motors & Controls
HVAC Motors

Series 20H Line Regenerative Digital DC Controls


Armature Output Current Chassis
Hp Input Volt Catalog Number List Price Mult. Sym.
Amps Cont Amps Peak Size
230 Volt Input - 240 VDC Output
Farm Duty

5 230 20 60 BC20H205-CL 5,832 E1 A


Motors

10 230 40 120 BC20H210-CL 5,832 E1 A


15 230 60 150 BC20H215-CL 5,832 E1 A
20 230 75 190 BC20H220-CL 6,112 E1 B
25 230 100 250 BC20H225-CL 6,883 E1 B
40 230 140 420 BC20H240-CL 8,928 E1 C
Definite Purpose

50 230 180 480 BC20H250-CL 9,660 E1 C


Motors

60 230 210 540 BC20H260-CL 10,215 E1 C


75 230 270 680 BC20H275-CL 12,531 E1 C
460 Volt Input - 500 VDC Output
5, 7.5, 10 460 20 60 BC20H410-CL 6,137 E1 A
15, 20 460 40 120 BC20H420-CL 6,137 E1 A
25, 30 460 60 150 BC20H430-CL 6,335 E1 A
Brake Motors

40 460 75 190 BC20H440-CL 6,615 E1 B


50 460 100 250 BC20H450-CL 7,336 E1 B
60, 75 460 140 420 BC20H475-CL 10,150 E1 C
100 460 180 480 BC20H4100-CL 10,953 E1 C
125 460 210 530 BC20H4125-CL 12,214 E1 C
150 460 270 680 BC20H4150-CL 13,359 E1 C
200 460 350 875 BC20H4200-CL 16,061 E1 D
200 & 575 Volt

250 460 420 1050 BC20H4250-CL 20,114 E1 D


Motors

300 460 510 1250 BC20H4300-CL 22,034 E1 D


OPTIONS: See pages 253-254 for optional expansion Boards including Tachometer Feedback, RS-232, RS-422, RS-485, Resolver, Interface, etc.
40 Amp field power supply. FPS40BC1920
IEC Frame
Motors

Dimensions in/(mm)
Outside Mounting Ap’x
Size
50 Hertz
Motors

Hp Height Width Depth Height Width Shpg. Wgt.


A ALL 20.60/(523.2) 11.00/(279.4) 9.87/(250.7) 18.00/(457.2) 10.25/(260.4) 39
B 230V ALL 25.70/(652.8) 11.00/(279.4) 9.84/(249.9) 23.87/(606.3) 10.25/(260.4) 67
B 460V ALL 26.75/(679.5) 11.00/(279.4) 9.84/(249.9) 24.94/(633.5) 10.25/(260.4) 69
C 230V 40-60 26.50/(673.1) 11.75/(298.5) 10.63/(270.0) 23.90/(607.0) 10.25/(260.4) 80
Motors & Controls

C 460V 75-100 27.25/(692.2) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 84


Inverter/Vector

C 230V 75 33.00/(838.2) 11.75/(298.5) 10.63/(270.0) 23.90/(607.6) 10.25/(260.4) 94


C 460V 125-200 33.75/(857.3) 11.75/(298.5) 10.63/(270.0) 24.65/(626.1) 10.25/(260.4) 97
D ALL 43.80/(1112.5) 16.87/(428.5) 12.43/(315.7) 39.25/(997.0) 13.75/(349.3) 272
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­302
DC Motors & Controls

HVAC Motors
FlexPak 3000
Digital DC Drives Applications: Three-phase DC drive for regenerative and non-regenerative
industrial applications from 1-1/2 to 600 Hp

Features: Flexible design allows for adaptability and use in many demanding

Farm Duty
Motors
applications. The Operator Interface Module has a keypad panel and easy
to read graphics LCD display. Simple to set up and use with a step by step
“Quick Start” program. Operating status and diagnostic information as well as
help text aids in set up and operation. The drive may be operated from the
OIM or from a remotely mounted control station.

Definite Purpose
Motors
230 VAC, 50/60 Hz, Non-Regenerative; 1-1/2 Hp-30 Hp
230 VAC drives use equivalent rated 460 VAC drives listed below with required
916FK0100 460 VAC/230 VAC conversion kits
240 VDC Armature; 150 VDC Field

Brake Motors
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
1-1/2 10 7 10 3FN4042 VS50D 3,870
2 11 9 10 5FN4042 VS50D 3,870

200 & 575 Volt


3 13 12 10 7FN4042 VS50D 3,870

Motors
5 19 20 10 10FN4042 VS50D 3,885
7-1/2 26 29 10 15FN4042 VS50D 4,040
10 33 38 10 20FN4042 VS50D 4,070
15 48 55 10 30FN4042 VS50D 4,385
20 63 73 15 40FN4042 VS50D 5,201

IEC Frame
Motors
25 80 93 15 50FN4042 VS50D 5,025
30 94 110 15 60FN4042 VS50D 5,090

230 VAC, 50/60 Hz, Regenerative; 1-1/2 Hp-30 Hp


230 VAC drives use equivalent rated 460 VAC drives listed below with required
916FK0100 460 VAC/230 VAC conversion kits

50 Hertz
Motors
240 VDC Armature; 150 VDC Field
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current

Motors & Controls


Inverter/Vector
1-1/2 10 7 10 3FR4042 VS50D 4,380
2 11 9 10 5FR4042 VS50D 4,380
3 13 12 10 7FR4042 VS50D 4,380
5 19 20 10 10FR4042 VS50D 4,395
7-1/2 26 29 10 15FR4042 VS50D 4,550
10 33 38 10 20FR4042 VS50D 4,580
and Controls
DC Motors

15 48 55 10 30FR4042 VS50D 4,895


20 63 73 15 40FR4042 VS50D 5,425
25 80 93 15 50FR4042 VS50D 5,635
30 94 110 15 60FR4042 VS50D 5,700
Dynamic Brakes
Soft Start &

Dimensions

Width Height Depth Weight


Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
All 230 VAC, (460 VAC Converted), cata-
10.65 (270.5) 18.79 (477.3) 12.23 (310.6) 58 (26.4)
log numbers, 1-1/2 through 30 Hp ­303
DC Motors & Controls
HVAC Motors

FlexPak 3000 Digital DC Drives


Farm Duty
Motors
Definite Purpose
Motors

230 VAC, 50/60 Hz, Non-Regenerative; 40 Hp-75 Hp


230 VAC drives listed below use equivalent rated 460 VAC drives with required
916FK0200 460 VAC/230 VAC conversion kits.
240 VDC Armature; 150 VDC Field
Brake Motors

Full Load Rated


Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
40 125 146 15 75FN4042 VS50D 6,120
50 154 180 15 100FN4042 VS50D 6,835
200 & 575 Volt

60 186 218 15 125FN4042 VS50D 7,140


Motors

75 226 265 15 150FN4042 VS50D 7,750

230 VAC, 50/60 Hz, Regenerative; 40 Hp-75 Hp


230 VAC drives listed below use equivalent rated 460 VAC drives with required
IEC Frame
Motors

916FK0200 460 VAC/230 VAC conversion kits.


240 VDC Armature; 150 VDC Field
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
40 125 146 15 75FR4042 VS50D 6,935
50 Hertz
Motors

50 154 180 15 100FR4042 VS50D 7,650


60 186 218 15 125FR4042 VS50D 7,955
75 226 265 15 150FR4042 VS50D 8,570
Motors & Controls
Inverter/Vector

Dimensions
Width Height Depth Weight
Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
and Controls
DC Motors

All 230 VAC catalog numbers,


18.11 (460) 490 (19.29) 13.46 (341.9) 122 (55)
40 through 75 Hp
Dynamic Brakes
Soft Start &

­304
DC Motors & Controls

HVAC Motors
FlexPak 3000 Digital DC Drives

Farm Duty
Motors
Definite Purpose
230 VAC, 50/60 Hz, Non-Regenerative; 100 Hp-150 Hp

Motors
230 VAC catalog numbers do not exist for these Hp ratings. Use a 460 VAC drive at 2X
Hp rating and reconnect control power transformer for 230VAC operation at startup.
240 VDC Armature; 150 VDC Field
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List

Brake Motors
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
100 307 360 15 200FN4042 VS50D 12,035
125 370 434 15 250FN4042 VS50D 12,545
150 443 521 15 300FN4042 VS50D 12,545

200 & 575 Volt


Motors
230 VAC, 50/60 Hz, Regenerative; 100 Hp-150 Hp
230 VAC catalog numbers do not exist for these Hp ratings. Use a 460 VAC drive at 2X
Hp rating and reconnect control power transformer for 230VAC operation at startup.
240 VDC Armature; 150 VDC Field

IEC Frame
Motors
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
100 307 360 15 200FB4042 VS50D 19,100
125 370 434 15 250FB4042 VS50D 19,360

50 Hertz
Motors
150 443 521 15 300FB4042 VS50D 20,300

Motors & Controls


Dimensions Shown for 460VAC Models

Inverter/Vector
Width Height Depth Weight
Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
All 230 VAC drives,
100 through 150 Hp,
23.6 (599) 33.5 (850) 16.7 (424.7) 220.5 (100.0)
(All 460 VAC catalog numbers,
200 through 300 Hp)
and Controls
DC Motors

NOTE: Option kits may add additional mounting depth. Please allow adequate clearance when option kits are mounted on the drive package.
Dynamic Brakes
Soft Start &

­305
DC Motors & Controls
HVAC Motors

FlexPak 3000 Digital DC Drives


Farm Duty
Motors
Definite Purpose
Motors

460 VAC, 50/60 Hz, Non-Regenerative; 3 Hp-60 Hp


500 VDC Armature; 300 VDC Field
Full Load Rated
Brake Motors

Full Load RMS Rated Field Catalog Mult. List


Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
3 10 6 10 3FN4042 VS50D 3,870
5 12 10 10 5FN4042 VS50D 3,870
7.5 15 14 10 75FN4042 VS50D 6,120
10 18 19 10 10FN4042 VS50D 3,885
200 & 575 Volt
Motors

15 24 27 10 15FN4042 VS50D 4,040


20 31 35 10 20FN4042 VS50D 4,070
25 39 45 10 25FN4042 VS50D 4,335
30 45 52 10 30FN4042 VS50D 4,385
40 63 73 15 40FN4042 VS50D 5,201
IEC Frame

50 74 86 15 50FN4042 VS50D 5,025


Motors

60 86 100 15 60FN4042 VS50D 5,090

460 VAC, 50/60 Hz, Regenerative; 3 Hp-60 Hp


500 VDC Armature; 300 VDC Field
Full Load Rated
50 Hertz
Motors

Full Load RMS Rated Field Catalog Mult. List


Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
3 10 6 10 3FR4042 VS50D 4,380
5 12 10 10 50FR4042 VS50D 5,635
Motors & Controls

7.5 15 14 10 7FR4042 VS50D 4,380


Inverter/Vector

10 18 19 10 10FR4042 VS50D 4,395


15 24 27 10 15FR4042 VS50D 4,550
20 31 35 10 20FR4042 VS50D 4,580
25 39 45 10 25FR4042 VS50D 4,845
30 45 52 10 30FR4042 VS50D 4,895
and Controls
DC Motors

40 63 73 15 40FR4042 VS50D 5,425


50 74 86 15 50FR4042 VS50D 5,635
60 86 100 15 60FR4042 VS50D 5,700

Dimensions
Dynamic Brakes
Soft Start &

Width Height Depth Weight


Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
All 460 VAC catalog numbers,
10.65 (270.5) 18.79 (477.3) 12.23 (310.6) 58 (26.4)
3 through 60 Hp

­306
DC Motors & Controls

HVAC Motors
FlexPak 3000 Digital DC Drives

Farm Duty
Motors
Definite Purpose
460 VAC, 50/60 Hz, Non-regenerative; 75 Hp-150 Hp

Motors
500 VDC Armature; 300 VDC Field
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current

Brake Motors
75 110 129 15 75FN4042 VS50D 6,120
100 143 167 15 100FN4042 VS50D 6,835
125 177 207 15 125FN4042 VS50D 7,140
150 213 250 15 150FN4042 VS50D 7,750

200 & 575 Volt


Motors
460 VAC, 50/60 Hz, Regenerative; 75 Hp-150 Hp
500 VDC Armature; 300 VDC Field
Full Load Rated

IEC Frame
Full Load RMS Rated Field Catalog Mult. List

Motors
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Current
75 110 129 15 75FR4042 VS50D 6,935
100 143 167 15 100FR4042 VS50D 7,650
125 177 207 15 125FR4042 VS50D 7,955
150 213 250 15 150FR4042 VS50D 8,570

50 Hertz
Motors
Motors & Controls
Inverter/Vector
Dimensions
Width Height Depth Weight
Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
All 460 VAC catalog numbers,
18.11 (460) 19.29 (490) 13.46 (341.9) 122 (55)
75 through 150 Hp
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­307
DC Motors & Controls
HVAC Motors

FlexPak 3000 Digital DC Drives


Farm Duty
Motors
Definite Purpose
Motors

460 VAC, 50/60 Hz, Non-Regenerative; 200 Hp-300 Hp


500 VDC Armature; 300 VDC Field
Full Load Rated
Full Load RMS Rated Field Catalog Mult. List
Hp Rating DC Armature
AC Line Current Current Number Sym. Price
Brake Motors

Current
200 281 330 15 200FN4042 VS50D 12,035
250 351 412 15 250FN4042 VS50D 12,545
300 421 495 15 300FN4042 VS50D 12,545
200 & 575 Volt
Motors

460 VAC, 50/60 Hz, Regenerative; 75 Hp-150 Hp


500 VDC Armature; 300 VDC Field
Full Load Rated
IEC Frame

Full Load RMS Rated Field Catalog Mult. List


Hp Rating DC Armature
Motors

AC Line Current Current Number Sym. Price


Current
200 281 330 15 200FB4042 VS50D 19,100
250 351 412 15 250FB4042 VS50D 19,360
300 421 495 15 300FB4042 VS50D 20,300
50 Hertz
Motors
Motors & Controls
Inverter/Vector

Dimensions
Width Height Depth Weight
Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
All 460 VAC catalog numbers,
23.6 (599) 33.5 (850) 16.7 (424.7) 220.5 (100)
200 through 300 Hp
and Controls
DC Motors

NOTE: Option kits may add additional mounting depth. Please allow adequate clearance when option kits are mounted on the drive package.
Dynamic Brakes
Soft Start &

­308
DC Motors & Controls

HVAC Motors
FlexPak 3000 Digital DC Drives

Farm Duty
Motors
Definite Purpose
460 VAC, 50/60 Hz, Non-Regenerative; 400 Hp-600 Hp

Motors
500 VDC Armature; 300 VDC Field
Full Load Rated
Full Load RMS Rated Field Drive Mult. List
Hp Rating DC Armature
AC Line Current Current Catalog Number Sym. Price
Current

Brake Motors
400 567 667 15 400FN4041 VS50D 19,025
500 680 800 15 500FN4041 VS50D 19,280
600 816 960 15 600FN4041 VS50D 19,890

200 & 575 Volt


460 VAC, 50/60 Hz, Regenerative; 400 Hp-600 Hp

Motors
500 VDC Armature; 300 VDC Field
Full Load Rated
Full Load RMS Rated Field Drive Mult. List
Hp Rating DC Armature
AC Line Current Current Catalog Number (a) Sym. Price
Current
400 567 640 15 400FR4041 VS50D 30,090

IEC Frame
Motors
500 680 800 15 500FR4041 VS50D 30,600
600 816 960 15 600FR4041 VS50D 31,110
NOTE: (a) An inverting fault circuit breaker, Model Number 906FK3101 must be specified with 400-600 Hp regenerative drives and is included in Drive price.
Refer to OPTIONS section for description.

50 Hertz
Motors
Dimensions
Width Height Depth Weight
Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)

Motors & Controls


All 460 VAC catalog numbers,

Inverter/Vector
26.68 (677.7) 42.25 (1149.2) 18.82 (478.1) 450 (204.5)
400 through 600 Hp
NOTE: Option kits may add additional mounting depth. Please allow adequate clearance when option kits are mounted on the drive package.

and Controls
DC Motors
Dynamic Brakes
Soft Start &

­309
DC Motors & Controls
HVAC Motors

FlexPak 3000 Digital DC Drives


Farm Duty
Motors
Definite Purpose
Motors

Special AC Line Voltage Drives (b)

For 380 VAC or 415 VAC input, select the required armature amps to price the drive.
Hp and kW ratings are estimated and should only be used as an approximation.
Brake Motors

Special 380/415 VAC Non-Regenerative FlexPak 3000(b)


380 VAC 415 VAC 460 VAC
400 VDC Armature 460 VDC Armature 500 VDC Armature DC DC
Catalog Mult. List
250 VDC Field (a) 270 VDC Field(a) 300 VDC Field(a) AC Amps Armature Field
Number Sym. Price
Amps Amps
Hp kW Hp kW Hp kW
2.4 1.8 2.8 2.1 3 2.2 10 7 10 7FN3042 VS50D 4,380
200 & 575 Volt

12 9 13.8 10.3 15 11.2 26 29 10 29FN3042 VS50D 4,550


Motors

24 17.9 27.6 20.6 30 22.4 48 55 10 55FN3042 VS50D 4,895


48 35.8 55.2 41.2 60 44.7 94 110 15 110FN3042 VS50D 5,600
120 89.5 138 102.9 150 111.9 226 265 15 265FN3042 VS50D 8,160
Special 380/415 VAC Regenerative FlexPak 3000(b)
2.4 1.8 2.8 2.1 3 2.2 10 7 10 7FR3042 VS50D 4,890
IEC Frame
Motors

12 9 13.8 10.3 15 11.2 26 29 10 29FR3042 VS50D 5,060


24 17.9 27.6 20.6 30 22.4 48 55 10 55FR3042 VS50D 5,405
48 35.8 55.2 41.2 60 44.7 94 110 15 110FR3042 VS50D 6,210
120 89.5 138 102.9 150 111.9 226 265 15 265FR3042 VS50D 9,080
(a) Hp and KW ratings are estimated.
50 Hertz

(b) Requires use of nonstandard voltage DC motors. Contact Baldor-Reliance sales office for motor pricing assistance.
Motors

Dimensions
Motors & Controls
Inverter/Vector

Height Width Depth Weight


Catalog Number
Inches (mm) Inches (mm) Inches (mm) lbs (kg)
7 to 110A
18.79 (477.3) 10.65 (270.5) 12.23 (310.6) 58 lb (26.4)
Rated Output
265A
19.29 (490.0) 18.11 (460.0) 13.46 (341.9) 122 (55)
Rated Output
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­310
DC Motors & Controls

HVAC Motors
FlexPak 3000 Power Module Style Drives

Farm Duty
Motors
Three-Phase DC Power Module Drive for Regenerative and Non-Regenerative
Applications from 5 to 400 Hp

Definite Purpose
FlexPak 3000 Power Module drives can support 200-460 VAC line input voltages. The customer must select and provide

Motors
the appropriate fusing, control transformer, and contactor for the desired line input voltage. Keypad Operator Interface
Module (OIM) must be ordered separately.
Non-Regenerative Power Module
Hp Nom. Unit Type Mult. List
Catalog Number
at 460 VAC (a) Current Rating (b)(d) Current Rating (c)(d) Sym. Price

Brake Motors
10 20 25 20FN8742 VS50D 3,570
29 50 60 50FN8742 VS50D 3,685
75 125 150 125FN8742 VS50D 4,115
125 208 250 200FN8742 VS50D 4,895
200 375 450 375FN8742 VS50D 7,140

200 & 575 Volt


400 667 800 650FN8742 VS50D 9,280

Motors
Regenerative Power Module
10 20 25 20FR8742 VS50D 3,925
29 50 60 50FR8742 VS50D 4,080
75 125 150 125FR8742 VS50D 4,750

IEC Frame
125 208 250 200FR8742 VS50D 5,825

Motors
200 375 450 375FR8742 VS50D 8,260
400 667 800 650FR8742 VS50D 11,525
(a) Hp based on 40°C ambient & 460 VAC line input voltage at nominal rating. Derate at 1.5% per °C above 40°C
(b) Nominal current rating is 100% continuous operation with 50% overload capability.
(c) Unit-type current rating based on maximum continuous operation without overload.
(d) Field current regulator rating: 4A (25-60A Ratings), 10A (150-450A Ratings), 12A (800A Rating). Rating is based on unit-type amp rating.

50 Hertz
Motors
Note: All ratings are based on 40°C Ambient

Power Module Style Drive Options


Mult.
Description Catalog Number List Price

Motors & Controls


Sym.

Inverter/Vector
Keypad Operator Interface Module (OIM) 317C160D VS50D 600
Configuration Software (CS3000) 2CS3000 E8 418

Power Module Dimensions


Hp Unit Type Width Height Depth Weight
and Controls

Nom. Current (b)


DC Motors

at 460 VAC Rating (a) Current Rating (c) Inches (mm) Inches (mm) Inches (mm) lbs (kg)
10 20 25 10.6 (269) 15.8 (400) 11.3 (287) 22 (10)
29 50 60 10.6 (269) 15.8 (400) 11.3 (287) 22 (10)
75 125 150 10.6 (269) 16.9 (428) 11.3 (287) 31 (14)
125 208 250 10.6 (270) 21.7 (550) 13.3 (337) 88 (40)
Dynamic Brakes
Soft Start &

200 375 450 10.6 (270) 21.7 (550) 13.3 (337) 88 (40)
400 667 800 12.1 (306) 26.0 (660) 17.2 (436) 183 (83)
(a) Hp based on 40°C Ambient & 460 VAC line input voltage at Nominal Rating. Derate at 1.5% per °C above 40°C.
(b) Nominal Current Rating is 100% continuous operation with 50% overload capability.
(c) Unit Type Current Rating based on maximum continuous operation without overload.

­311
DC Motors & Controls
HVAC Motors

FlexPak 3000 Drive Options


AC Line Disconnects for Chassis or NEMA 1 Enclosed Drives
Select and price disconnect per the table below. This kit cannot be mounted on the FlexPak 3000 Power Module drives.
Farm Duty

AC Line Disconnects Selection


Motors

Incoming Line Voltage Disconnect for Chassis Drives Disconnect for NEMA 1 Conversion Kit Mounting (a)
Mult. List Mult. List
230 VAC 460 VAC Catalog Number Catalog Number
Sym. Price Sym. Price
1-1/2 - 25 3-50 901FK0101 VS50D 555 902FK0101 VS50D 400
Definite Purpose

30 60 901FK0201 VS50D 660 901FK0201 VS50D 660


Motors

40-60 75-125 901FK1102 VS50D 1,350 901FK1112 VS50D 1,425


75 150 901FK1202 VS50D 2,100 901FK1212 VS50D 2,175
100 200 901FK2101 VS50D 2,500 — — —
125-150 250-300 901FK2201 VS50D 4,075 — — —
Brake Motors

— 400 901FK2401 VS50D 5,070 — — —


— 500 901FK2401 VS50D 5,070 — — —
— 600 901FK2501 VS50D 7,625 — — —
(a) Enclosure not included in price.
200 & 575 Volt

Blower Motor Starter


Motors

This option provides a fused AC starter with adjustable overload and interlocking for control of the three-phase blower
motor used to cool the DC motor. This kit cannot be mounted on FlexPak 3000 Power Module drives.
Blower 3-Phase Current Amps Single Starter Catalog Number
.4-.63 902FK0101
.63-1.0 902FK0201
IEC Frame
Motors

1.0-1.4 902FK0301
1.4-1.8 902FK0401
1.7-2.4 902FK0501
2.2-3.1 902FK0601
2.8-4.0 902FK0701
50 Hertz
Motors

3.5-5.0 902FK0801
4.5-6.5 902FK0901
6.0-8.5 902FK0111
7.5-11.0 902FK0121
Motors & Controls
Inverter/Vector

Description List Price Mult. Sym.


Kit 400 VS50D
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­312
DC Motors & Controls

HVAC Motors
FlexPak 3000 Drive Options
115V Control Interface
This option consists of a printed circuit board which converts customer-supplied 115 VAC signals to 24 VDC for operating
a FlexPak 3000. This card mounts separately on the chassis drives or can be mounted in drives with optional NEMA 1

Farm Duty
conversion kits.

Motors
INPUTS AND OUTPUTS
• Run • Stop
• Jog • Fwd/Rev

Definite Purpose
• Auto/Man • Coast/Stop

Motors
• Customer Interlock • Fault reset
• Brush wear • Motor thermostat

Kit Catalog Number Mult. Sym List Price

Brake Motors
917FK0101 VS50D 500

Conversion Kit 460 VAC to 230 VAC


This kit contains control transformer fuses that allows the user to convert a 460 VAC FlexPak 3000 to a 230 VAC drive at

200 & 575 Volt


one-half the 460 VAC horsepower rating. This kit cannot be used with FlexPak 3000 Power Module drives.

Motors

A fuse kit is not required to convert 200-600 Hp 460 VAC FlexPak 3000 drives to 230 VAC.
The Control Circuit Transformer must be re-connected for 230 VAC.
Contact a Baldor representative for assistance.
Mult. List Price List Price
Catalog Number This fuse kit will convert
Sym. Ordered with Drive Ordered Separately

IEC Frame
Motors
916FK0100 FlexPak 3000, 3-60 Hp @ 460 VAC to 1-1/2 - 30 Hp @ 230 VAC VS50D N/C 50
916FK0200 FlexPak 3000, 75-150 Hp @ 460 VAC to 40-75 Hp at 230 VAC VS50D N/C 50

50 Hertz
Motors
Motors & Controls
Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­313
DC Motors & Controls
HVAC Motors

FlexPak 3000 Drive Options


Dynamic Braking (DB)
240 VDC Dynamic Braking Loose Parts Kit (c)
Hp Rating Catalog Number Mult. Sym. Kit List (a)
Farm Duty
Motors

1-1/2 912FK0010 VS50D 850


2 912FK0020 VS50D 850
3 912FK0030 VS50D 850
5 912FK0050 VS50D 850
912FK0070
Definite Purpose

7-1/2 VS50D 885


10 912FK0100 VS50D 940
Motors

15 912FK0150 VS50D 940


20 912FK0200 VS50D 1,220
25 912FK0250 VS50D 1,220
30 912FK0300 VS50D 1,250
Brake Motors

40 912FK0400 VS50D 1,500


50 912FK0500 VS50D 1,800
60 912FK0500 VS50D 1,800
75 912FK0750 VS50D 2,050
500 VDC Dynamic Braking Loose Parts Kit (c)
200 & 575 Volt

3 913FK0030 VS50D 880


Motors

5 913FK0050 VS50D 880


7-1/2 913FK0070 VS50D 880
10 913FK0100 VS50D 1,135
15 913FK0150 VS50D 1,135
20 913FK0200 VS50D 1,210
IEC Frame
Motors

25 913FK0200 VS50D 1,210


30 913FK0300 VS50D 1,240
40 913FK0400 VS50D 1,240
50 913FK0500 VS50D 1,325
60 913FK0500 VS50D 1,325
913FK0750
50 Hertz

75 VS50D 1,850
Motors

100 913FK1000 VS50D 2,000


125 913FK1000 VS50D 2,200
150 913FK1500 VS50D 2,640
200 913FK2000 VS50D 4,900
Motors & Controls
Inverter/Vector

250 913FK2500 VS50D 5,000


300 913FK3000 VS50D 5,000
400 913FK4000 VS50D 2,800 (b)
500 913FK5000 VS50D 3,000 (b)
600 913FK6000 VS50D 3,200 (b)
and Controls

(a) Includes D/B contactor and D/B resistors. Customer must supply fuses and 115 VAC power for contactor.
DC Motors

(b) Kit consists of resistors and enclosure only. Drive has DB pole on contactor as standard.
(c) This kit cannot be used with FlexPak 3000 Power Module drives. Contact your local Baldor•Reliance sales office for assistance.
Dynamic Brakes
Soft Start &

­314
DC Motors & Controls

HVAC Motors
FlexPak 3000 Drive Options
Enhanced Field Supply
This FlexPak 3000 Field Supply option provides the following additional features:
• Electronic Field trim

Farm Duty
• Field economy

Motors
• Capability to provide 240 VDC field supply with 230 VAC input

AC Line Input DC Field Voltage Output

Definite Purpose
103 to 207 DC
230 VAC
207 to 259 DC

Motors
207 to 414 DC
460 VAC
414 to 575 DC

This modification replaces the standard field supply or field current regulator.

Brake Motors
Motor field weakening is not possible with this kit.
Catalog Mult. Kit
230 VAC Hp 460 VAC Hp DC Amps
Number Sym. List Price
1-1/2 - 15 3 - 30 10 923FK0101 VS50D 500
20 - 300 40 - 600 20 923FK0201 VS50D 650

200 & 575 Volt


Motors
Field Current Regulator
The field current regulator kit replaces the standard field voltage supply with a current regulated supply. It provides field
economy and constant horsepower above, base speed operation. It can be used in drive version 3.0 and later.

IEC Frame
Approx. Hp (a) Field Current
Mult.

Motors
Motor Hot Field Amps Regulator Catalog Kit List (b)
230 VAC Hp 460 VAC Hp Sym.
Number (b)(c)
1-1/2 - 10 3 - 20 4 911FK0041 VS50D 280
1-1/2 - 15 3 - 30 10 911FK0101 VS50D 300
20-60 40-125 15 911FK0151 VS50D 320

50 Hertz
75-300 150-600 15 — — Std.

Motors
(a) For estimating only. Field current regulator should be sized according to motor hot field amps.
(b) Requires V3.0 or later FlexPak 3000. (Second to last digit of drive M/N must be a “3” or larger.)
This kit is standard on all FlexPak 3000 drives 75 Hp @ 230 VAC/150 Hp @ 460 VAC and larger and on FlexPak 3000 Power Module drives.
(c) A field current regulator kit cannot be used when using an Enhanced Field Supply kit.

Motors & Controls


Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­315
DC Motors & Controls
HVAC Motors

FlexPak 3000 Drive Options


I/O Expansion Card
The I/O expansion card mounts in the FlexPak 3000 chassis and gives the FlexPak 3000 additional analog, frequency
and digital I/O capability. Some additional features with this card are:
Farm Duty

• Dancer follower functions


Motors

• Outer Control Loop (OCL) applications


• External motor operated pot (MOP) function
• (3) preset speeds
• (2) user configurable analog outputs
Definite Purpose

• (1) user configurable frequency output


Motors

• (1) user configurable frequency input


• (2) timed threshold level detectors
Available I/O
5 Digital Inputs (24 VDC, isolated)
Brake Motors

(2) inputs for preset speed selection


(2) inputs for MOP increment and decrement
(1) input for OCL enable

2 Level Detectors (30 VDC or 250 VAC)


200 & 575 Volt

• Selectable normally open or normally closed


Motors

• Detected when signals exceed an adjustable threshold


• Timed delay output from 0 to 300 seconds

2 Analog Inputs (Isolated)


• Input 1: ±10 VDC, 4-20 mA, 10-50 mA
• Input 2: 0-10 VDC (or ±10 VDC)
IEC Frame
Motors

• Voltage scalable from 4.4 V to 10.0 V


• Steerable to OCL reference and feedback, speed reference trim, positive current limit (negative also if regenerative)
and inertia compensation

2 Analog Outputs (unfiltered)


• Output 1: ±10 VDC (@ 4mA maximum)
50 Hertz
Motors

• Output 2: ±10 VDC (@ 4mA maximum)


• User configurable

1 Frequency Input
Motors & Controls

• Differential 5 to 15 V square wave (single direction)


Inverter/Vector

• Scalable from 2 to 250 kHz


• User configurable

1 Frequency Output
• Differential 5 to 15 V square wave (single direction)
• Scalable from 2 to 250 kHz
and Controls
DC Motors

• User configurable

Outer Control Loop (OCL)
• Dancer follower (Type I position loop)
• Dancer position regulator (Type II position loop)
• See I/M D2-3301 for more detailed information of the
Dynamic Brakes
Soft Start &

• I/O expansion card.


Kit Model Number Mult. Sym. List Price
914FK0101 VS50D 660

(1) Requires V3.0 or later FlexPak 3000. (Second last digit of controller M/N must be “3” or higher.)
­316
DC Motors & Controls

HVAC Motors
FlexPak 3000 Drive Options
Network Communications
AutoMax Network Communication Card
The AutoMax Network Communication card mounts in a FlexPak 3000 drive allowing it to communicate with an AutoMax

Farm Duty
network. The drive can be controlled, tuned, and monitored by way of the high speed (875 Kbaud) AutoMax network link.

Motors
Up to 55 FlexPak 3000 drives can be connected to a single network using the basic configuration or up to 13 using the
full configuration.
Kit Catalog Number Mult. Sym. List Price (a)

Definite Purpose
915FK0101 VS50D 441

Motors
ControlNet™ Communication Card
The ControlNet Communication card mounts in a FlexPak 3000 drive, allowing it to communicate over the open network
ControlNet. ControlNet is a highly deterministic and repeatable control layer network. It provides real-time high speed

Brake Motors
transport of time critical I/O data and messaging data, all on one link. ControlNet is ideal for complex control systems that
require synchronized and coordinated real-time performance.

Kit Catalog Number Mult. Sym. List Price (a)(b)


915FK2101 VS50D 735

200 & 575 Volt


DeviceNet™ Communication Card

Motors
The DeviceNet Communication card mounts in a FlexPak 3000 drive, allowing it to communicate over the open network
DeviceNet. The card provides the ability to modify parameters plus operate and monitor the FlexPak 3000. Horner
Electric Co. manufactures this card. More information is obtainable from I/M HE-FP3.

Kit Catalog Number Mult. Sym. List Price (a)(c)

IEC Frame
Motors
915FK1100 VS50D 615

Interbus-S™ Communication Card


The Interbus-S Communication card mounts in the FlexPak 3000 drive, allowing it to communicate with an Interbus-S
network. The card allows the FlexPak 3000 drive to be controlled and monitored over the network.

50 Hertz
Motors
Kit Catalog Number Mult. Sym. List Price (a)(c)

Motors & Controls


915FK3101 VS50D 735

Inverter/Vector
Note that this card also requires a remote to local bus connector, such as the Phoenix Model IBS24BK/LC

Profibus™ Communication Card


and Controls

The Profibus Communication card allows the FlexPak 3000 to communicate over the Profibus network. This card allows
DC Motors

the FlexPak 3000 to be controlled and monitored over the network.

Kit Catalog Number Mult. Sym. List Price (a)(b)


915FK4101 VS50D 735
Dynamic Brakes

(a) Only one network card can be installed in the drive at one time
Soft Start &

(b) Must use V4.2 or higher firmware


(c) Must use V3.12 or higher firmware

­317
DC Motors & Controls
HVAC Motors

FlexPak 3000 Drive Options


Inverting Fault Circuit Breaker
This modification replaces the standard inverting fault fuse. The inverting fault circuit breaker is recommended when
applying regenerative FlexPak 3000 drives to high inertia loads (where the reflected load (WR2) to the motor is equal to or
Farm Duty

greater than the motor’s). It also is used on applications where the drive is frequently in a low power regenerative mode,
Motors

such as on un-winders and pay-offs. The inverting fault breaker must be mounted separately from the drive, unless the
drive is mounted in a cabinet.
HP Rating HP Rating Kit Mult. Kit
240 VDC 500 VDC Catalog Number Sym. List Price
Definite Purpose

1-1/2 - 2 3-5 906FK0101 VS50D 775


Motors

3-5 7.5-10 906FK0201 VS50D 775


7-1/2 - 10 15-20 906FK0301 VS50D 775
15-20 25-40 906FK0401 VS50D 900
25-30 50-60 906FK0501 VS50D 950
40-60 75-125 906FK1101 VS50D 1,600
Brake Motors

75 150 906FK1201 VS50D 2,350


100-150 200-300 Standard on FB model drives.
— 400-600 906FK3101 VS50D 775 (a)
(a) Included in drive price and must be specified with regenerative 400-600 Hp drives.
200 & 575 Volt

Line Filter Kit


Motors

The Line Filter kit is used on 400-600 Hp FlexPak 3000 drives when the primary of the drive’s source transformer is
greater than 2300 VRMS. The kit helps attenuate high voltage spikes that capacitively couple from the transformer
primary to secondary.

Hp Kit Catalog Number Mult. Sym. List Price


IEC Frame
Motors

400-600 918FK0601 VS50D 750

Operator Interface Module (OIM) Remote Mounting Kit


The kit includes a cable, bezel and blank OIM replacement panel for mounting to the drive chassis in applications where
it is desirable to locate the OIM away from the drive or in a cabinet door. The OIM can be then mounted up to 5 meters
50 Hertz
Motors

from the drive.

Kit Catalog Number Mult. Sym. List Price


905FK0101 VS50D 150
Motors & Controls
Inverter/Vector

V4.3 Regulator Upgrade (b)

This kit includes a V4.3 regulator board, grounding harness, CS3000 software and V4.3 software manual. This kit can be
used to upgrade V3.0(2) or higher FlexPak 3000 drives.

Kit Catalog Number Mult. Sym. List Price


and Controls
DC Motors

920FK0042 VS50D 775

Operator Interface Module (OIM) Drive-Mounted Kit (c)

This kit includes an OIM and all necessary connection hardware. This option is available for FlexPak 3000 Power Module
Dynamic Brakes

drives (standard on FlexPak 3000 drives).


Soft Start &

Kit Catalog Number Mult. Sym. List Price


317C160D VS50D 600

(b) Upgrading from a Version 2 FlexPak3000 Drive to Version 4 requires that both the regulator board and OIM kit be upgraded.
­318 (c) Second last digit of controller M/N must be “3” or higher.
DC Motors & Controls

HVAC Motors
FlexPak 3000 Drive Options
NEMA 1 Conversion Kit
This modification allows conversion of standard chassis to NEMA 1 enclosure. This kit cannot be used with FlexPak
3000 Power Module drives.

Farm Duty
Motors
HP Rating HP Rating Kit Mult. Kit
230 VAC 460 VAC Catalog Number Sym. List Price
1-1/2 - 30 3-60 904FK0101 VS50D 900
40-75 75-150 904FK0201 VS50D 1,100
100-150 200-300 N/A N/A N/A

Definite Purpose
— 400-600 N/A N/A N/A

Motors
Dimensions
Hp Rating Hp Rating Width Height Attached Depth
230VAC 460VAC Inches (mm) Inches (mm) Inches (mm)

Brake Motors
1-1/2 - 30 3-60 11.1 (281.2) 30. 6 (777.4) 12.15 (308.57)
40-75 75-150 18.9 (480) 37.8 (959.6) 13.1 (332.8)

18.9
(480.0)

200 & 575 Volt


Motors
11.1
(281.2)
8.5
(215.0)

37.9

IEC Frame
Motors
(959.6)

30.6
(777.4)

50 Hertz
Motors
24.4
(620.0) 28.2
(715.9)

Motors & Controls


Inverter/Vector
and Controls
DC Motors

3.3
(84.1)
Dynamic Brakes
Soft Start &

0.8 (20.0)
14.6
(370.0)

­319
DC Motors & Controls
HVAC Motors

FlexPak 3000 Drive Options


Software Programming and RS-232 Cables
CS3000 Software, Control and Configuration
This is a Microsoft Windows® based software package which allows drive Control & Configuration. The user is allowed to
Farm Duty

create, store, upload, download, monitor, control and/or compare parameter values in a user-friendly environment.
Motors

Compare; when performed either locally or over a remote modem allows quick qualification of any changed
parameters. Differences are displayed on the PC and may be printed.
• Edit; allows programming via PC.
Definite Purpose

• Download; allows one step programming of multiple parameters from drive memory.
• Upload; allows identification of existing drive parameters from drive memory.
Motors

• Drive control;
– Monitors 6 display values
– Speed reference (scalable)
– Motor speed
– Armature volts
Brake Motors

– Motor current
– Percent load
– Configurable displays are;
– Speed reference
– Control source
– Auto/Manual mode
200 & 575 Volt

– Fwd/Rev direction
Motors

– Operational keys displayed;


– Run, Jog, Stop, Reset
• Fault/Alarm Log; allows fault and alarm history for diagnosis of operation.
• PC Scope feature; allows monitoring and trace of two drive parameters for diagnostics and tuning of the drive.
Captured data can also be saved as an ASCII text file or can be compared to previous traces. (a)
IEC Frame
Motors

Provided on a 3.5” diskette with manual. (b) Note that this software is also compatible with GV3000 AC drives.

Reference Manual Number: D2-3348


Catalog Number Mult. Sym. List Price
2CS3000 (c) E8 418
50 Hertz
Motors

CS3000 Computer Cable


The 9-pin connector connects to the PC and the 25-pin connector connects to the FlexPak 3000 drive.
Motors & Controls
Inverter/Vector

Model Number * 2CA3001

(a) Requires V4.0 or later


(b) If a 3.5" disc drive is not available, contact your local Baldor•Reliance District Office for software package compatible with your PC storage.
(c) Requires Microsoft Windows 2000® or earlier version.
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­320
DC Motors & Controls

HVAC Motors
FlexPak 3000 Drive Options
Tachometer/Encoder (Speed Feedback)
Advantages of Closed-Loop Speed Regulation
For improved speed regulation, add a motor-mounted tachometer. For the best regulation, use an encoder (pulse

Farm Duty
tachometer) kit. Use the chart below to select speed feedback kits.

Motors
Speed Speed
Speed Maximum Type Feedback Kit Mult. Feedback Kit Less
Regulation Non-Regen. Regen.
Feedback Input Tachometer Catalog Sym. Tachometer/
Number Encoder List

Definite Purpose
Armature Voltage - - 2% √ √ - -

Motors
AC Tachometer 250 VAC RE 045 1% √ 907FK0301(b) VS50D 300
DC Tachometer (f) 250 VDC 5PY 1% √ √ Std. VS50D Std.
Encoder (Pulse) 73KHz (a) RD-120-1 (c) (e) 0.01% √ 907FK0101 VS50D 300
Encoder (Pulse) 73KHz (a) RD-120-2 V 0.01% √ 907FK0101 VS50D 300

Brake Motors
Encoder (Pulse) 73KHz (a) H56 (c) 0.01% √ √ 907FK0101 VS50D 300
Encoder (Pulse) 73KHz (a) RL-1024 (d) 0.01% √ √ 907FK0101 VS50D 300
(a) PPR x RPM = KHz
60,000
(b) Kit is intended for use with existing motors that have RE045 tachometers. For new motor and tachometer applications, select another tachometer and appropriate
feedback kit. AC tachometers are not suitable for Regenerative reversing drive applications.

200 & 575 Volt


(c) 120 PPR
(d) 1024 PPR

Motors
(e) Not suitable for use in TENV frames DC180, DC210, or C180.
(f) Requires minimum 18VDC/1000 tachometer.

IEC Frame
Motors
50 Hertz
Motors
Motors & Controls
Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­321
DC Motors & Controls
HVAC Motors

Digital Speed Baldor’s microprocessor-based digital speed potentiometer with LED display
of set speed may be used to replace the conventional 3-wire analog speed
Potentiometer with pot for most AC and DC drives. Desired set speed may be entered into the
Display large 1/2” LED display by pressing the “up” and “down” pushbuttons: one
digit at a time or in a fast sweep. Display shows 0.1% increments of full motor
Farm Duty

speed (0-100%).
Motors
Definite Purpose
Motors

Specifications
Temperature -10°C to +45°C
AC input voltage 85-264 VAC
Input frequency 50/60 Hz
Supply voltage applied across output 5 VDC to 15 VDC
Brake Motors

Speed regulation Same as driven unit


Input impedance to DSP4 will drive 500 ohm to 100 K ohm
Output Isolated 3-wire pseudo-pot (normal or inverted output)
Display settings 0-100% of set speed range in 0.1% increments (resolution of 1000)
Non-volatile memory Retains last set point upon loss of AC power (user selectable via dip switch settings)
200 & 575 Volt

Catalog List Mult. Ap’x. Shpg. Input


Description
Motors

Number Price Sym. Wgt. Voltage


DSP4-6 Digital Speed Potentiometer with Display 509 E9 2 120/240 VAC 50/60 hz

Field Programmable
IEC Frame
Motors

Digital Tachometer for Baldor offers an economical micro-processor-based digital tachometer


Rate and Time with capable of measuring motor speeds as low as 1 rpm that is field
Display programmable for desired user specified units: RPM, FPM and GPM. Process
time or other engineering units requires an input signal unit with 1 to 30,000
PPR such as the HPU and RK60 devices. For use with digital tachometers.
50 Hertz
Motors
Motors & Controls
Inverter/Vector

Specifications
Temperature -10°C to +45°C
AC input voltage 85-264 VAC
Input frequency 50/60 Hz
Input pulse rate 1 to 30,000 input pulses per minute
and Controls

Resolution from 0.01 RPM


DC Motors

Accuracy ±0.04% display update every pulse or 0.5 seconds, whichever is longer
Isolated high/low alarm output 5 amp 240 VAC max.
Transducer signal input 0-5 to 0-24 VDC square wave (hall-effect, photoelectric, magnetic or any
TTL NPN open collector device.)
Dynamic Brakes

Catalog List Mult. Ap’x. Shpg. Input


Soft Start &

Description
Number Price Sym. Wgt. Voltage
DTM8000-6 Digital Tachometer for Rate & Time with Display 578 E9 1 120/240 VAC 50/60 hz

­322
DC Motors & Controls

HVAC Motors
Hall Effect Pickup HPU10 Provides square wave pulse feedback. HPU mounts to a stub shaft
opposite the pulley end of the motor and provides 10 pulses per
revolution. May be installed through Baldor’s Mod-Express

Features: HPU10 Series pick-up mounts directly on shaft being

Farm Duty
monitored using a single 10-32 screw (motor shaft requires modification

Motors
and/or an adapter). Use with BC450/BC440 DC controls and DTM8000
digital tachometer.

Specifications

Definite Purpose
Temperature -10°C to +45°C

Motors
Supply Voltage +4.5 to +24 VDC
Maximum Speed 5000 RPM
Output Cable 6 foot rubber-jacketed, 3 wire 18 AWG conductors
Red Wire: +VDC supply input
Black Wire: Common
White Wire: Signal

Brake Motors
Output Signal 10 pulses per revolution NPN output signal with built-in pull-up resistor.
Square wave output, signal voltage equals supply voltage. +5 VDC to +24 VDC supply voltage. Current sink: 5 mA maximum
Bearings Stainless steel ball bearing
Enclosure Compact housing molded of “Santoprene” plastic rubber

200 & 575 Volt


Hall Effect Pickup RK60 Provides square wave pulse feedback. The RK models are ring kits that

Motors
mount to the 56C and 145TC face of the motor. May be installed through
Baldor’s Mod-Express

Features: RK60 Series hall effect pick-up consists of a motor mounted


C-face ring, sensor, mounting bolts, and magnet disc. Use with BC450/

IEC Frame
BC440 DC controls and DTM8000 digital tachometer.

Motors
Specifications
Temperature -40°C to +125°C
Supply Voltage +4.5 to +24 VDC
Output Connection 3 wires

50 Hertz
Motors
Red Wire: +VDC supply input
Black Wire: Common
Blue Wire: Signal
Output Signal 60 pulses per revolution NPN output signal (may require external pull-up resistor).
Square wave output, signal voltage equals supply voltage. +5 VDC to +24 VDC supply voltage. Current sink: 20 mA

Motors & Controls


Inverter/Vector
Sensing Disk Molded magnet sensing disc, impervious to dust, dirt, and oil
Mounting C-face mounting ring has double C-face and is 0.750” thick.
(Please note that usable shaft length will be reduced by 0.750". Check application for suitability).

TK3300-HPU TK3400-HPU
Mounting Kit Mounting Kit
and Controls
DC Motors

for TENV/33P for TEFC/34P


DC Motors DC Motors
Catalog List Mult. Ap’x. Shpg.
Dynamic Brakes

Description
Number Price Sym. Wgt.
Soft Start &

HPU10 10 PPR Hall-Effect Pickup 192 E9 2


RK60-56 60 PPR Hall-Effect Pickup with 56C Ring Kit 632 E9 2
RK60-145 60 PPR Hall-Effect Pickup with 143-145TC Ring Kit 632 E9 2
TK3300-HPU HPU10 Mounting Kit for TENV/33P DC Motors (does not include pickup) 95 A8 1
TK3400-HPU HPU10 Mounting Kit for TEFC/34P DC Motors (does not include pickup) 110 A8 1
­323
DC Motors & Controls
HVAC Motors

Digital DC Controls 1/20 thru 1 Hp 115 VAC Single Phase 50/60 Hz


1/8 thru 2 Hp 230 VAC Single Phase 50/60 Hz

Applications: General purpose industrial use with permanent


magnet motors.
Farm Duty
Motors

Features: Compact programmable DC speed control with digital


closed loop feedback and LED display. Front-panel programming
allows customizing the control function and can display the set speed
in RPM, FPM, GPM, process time or any other engineering units.
Definite Purpose

Programmable parameters include minimum and maximum speed,


Motors

decimal points, operating mode (leader or follower), and Run/Jog


functions. Industry standard cutout dimensions of 1/8 DIN and 1/4 DIN
provide easy panel installation and NEMA 4X faceplate with supplied
gasket. Use with hall effect pickup shown on page 323.
Brake Motors

Specifications
Temperature -10 Deg C to +45 Deg C
AC input voltage Universal power supply rated at 85 to 265 VAC
200 & 575 Volt

Input frequency 50/60 Hz


Motors

Overload capacity 200% for 1 minute


Motor Feedback Input 0-24 Volt Square Wave Digital Tachometer
On-board power supply 5 VDC, 50mA (for external feedback sensor)
Pulse input capacity 50,000 PPM (500,000 with divider function on)
IEC Frame

Hp Catalog List Mult. Ap’x. Input


Description
Motors

Range Number Price Sym. Shpg. Wgt. Voltage


1/20-1/2 Digital Closed Loop DC Speed Control, 115 VAC 50/60 Hz
BC440-6 816 E9 2
1/8-1 1/8 DIN Panel Mount 230 VAC 50/60 Hz
1/8-1 Digital Closed Loop DC Speed Control, 115 VAC 50/60 Hz
BC450-6 1,111 E9 2
1/4-2 1/4 DIN Panel Mount 230 VAC 50/60 Hz
50 Hertz
Motors
Motors & Controls
Inverter/Vector
and Controls
DC Motors
Dynamic Brakes
Soft Start &

­324