Phasor Measurement Unit
Phasor Measurement Unit
or Synchrophasors
Dinesh Kajjam
Karthik Reddy Mekala
Contents
´ Motivation
´ SCADA (Supervisory Control and Data Acquisition)
´ Phasor
´ Phasor Measurement Unit
´ Architecture
´ Working
´ Real Time Dynamics Monitoring System
´ Applications
´ Challenges
´ Research
Motivation:
´ Need for more electricity
´ Integration and management of renewable energy
´ Optimal use of ageing assets
´ Ensure reliability of supply
´ Energy efficiency and security
´ Dynamic operation of power system
Power System Operational Paradigm
´ Sense
´ Communicate
´ Compute
´ Visualize
´ Control
´ Basically a solid-state relay or digital fault recorder with GPS clock.
´ The resultant time tagged phasors can be transmitted to a local or remote
receiver at rates up to 60 samples per second.
´ Continuously measures voltages and current phasors and other key parameters
and transmits time stamped messages.
Phasor Measurement Unit - Connections
´ Aligns information by time the incoming PMU messages from multiple
measuring devices and sends out the aggregated synchronized data set as
a single data stream.
Communication:
´ Links multiple PMUs to a PDC (or PDCs to other PDCs) for real time data
transfer.
´ The SOC time-tag counts the number of seconds that have occurred since
inception of PMU, With 3-bytes for the Fraction of Second, one second can
be broken down into 16,777,216 counts or about 59.6 nsec/count and the
Time Quality byte contains information about the status and relative
accuracy of the source clock
Phasor Measurement Unit – Performance
criteria
´ Accuracy for the Synchrophasor is measured by a value termed the “Total
Vector Error” or TVE.
´ TVE is defined as the square root of the difference squared between the
real and imaginary parts of the theoretical actual phasor and the
estimated phasor to the ratio of magnitude of the theoretical phasor and
presented as a percentage.
´ Phasor Measurement Unit (PMU) that must maintain less than a 1% TVE
under conditions of ±5 Hz of off-nominal frequency, 10% Total Harmonic
Distortion, and 10% out-of-band influence signal distortion.
Phasor Measurement Unit – Performance
criteria
Phasor Measurement Unit - Measurements
´ Phasor measurement data with GPS signal can provide synchronized
voltage and current phasor measurements across a wide region
´ By measuring the phase directly, the power transfer between buses can be
computed directly
´ High sampling rate (30 samples per second) Extended visibility: beyond
one’s own operating region
´ Visualization of PMU data – Difficult to visualize and manage large amounts
of data.