Computation For Air Receiver Tank

The document outlines a calculation to determine the maximum allowable working pressure (MAWP) of a pressure vessel using the thickness, material tensile strength, weld efficiency, inside radius, and a safety factor. It performs the calculation and finds the MAWP is 111 psi, which is above the required safety valve pressure of 100 psi and allows for automatic compressor control between 90-100 psi.

Uploaded by

Jysar Reubal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
195 views

Computation For Air Receiver Tank

The document outlines a calculation to determine the maximum allowable working pressure (MAWP) of a pressure vessel using the thickness, material tensile strength, weld efficiency, inside radius, and a safety factor. It performs the calculation and finds the MAWP is 111 psi, which is above the required safety valve pressure of 100 psi and allows for automatic compressor control between 90-100 psi.

Uploaded by

Jysar Reubal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

t = 0.

315”
𝑇𝑠 𝑥 𝑡 𝑥 𝐸
M.A.W.P. =
𝑅 𝑥 𝐹𝑠

Ts = 59,000 PSI for ASTM A-36 from Manufacturers data

E = 40% from PSME Code 2008 for single lag weld

R= inside radius (30”)from manufacturers data

AWP = Maximum allowable working pressure,150 PSI from manufacturers data

Fs = Factor of Safety, 5, based on PSME Code

ASME allows Factor of Safety of 4

t = 0.315”
𝑇𝑠 𝑥 𝑡 𝑥 𝐸
A.W.P. =
𝑅 𝑥 𝐹𝑠
59,000 𝑃𝑆𝐼 𝑥 0.315 𝑖𝑛 𝑥 0.9
A.W.P. =
30 𝑖𝑛 𝑥 4

A.W.P. = 111 PSI

1. The pressure vessel must be equipped with safety valve of


100 psi.
2. The pressure vessel must be equipped with a pressure
control to automatically start the compressor at 90 psi and
switch of at less than 100 psi.