MOVIDRIVE ® Addendum to:

US Encoder/Resolver Cables Installation Instructions

General
These operating instructions are intended to aid in the proper connection of Encoders and/or Resolvers that are used with the
Movidrive® drive inverter. SEW has several pre-fabricated cables to make connections to Movidrive® easier.

9E00 0428 - 330’ Encoder/Resolver Cable with (1) angled male connector.
9E00 0410 - 100’ Encoder/Resolver Cable with (1) angled male connector
9E00 0412 - 50’ Encoder/Resolver Cable with (1) angled male connector
9E00 0414 - 25’ Encoder/Resolver Cable with (1) angled male connector
9E00 0415 - 6’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Used to connect Movidrive® to DWI11A.
9E00 0416 - 6’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Can be used to connect Movidrive® Master-Slave synchronous connection with
DRS11A.
9E00 0418 - 3’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Can be used to connect Movidrive® Master-Slave synchronous connection with DRS11A.
9E00 0419 - 1.5’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Can be used to connect Movidrive® Master-Slave synchronous connection with DRS11A.

Other related reference material that may be useful for connection, commissioning and project planning are:
SEW Encoder Systems Manual
Movidrive® System Manual
Movidrive® Synchronous Operation Type DRS11A Manual

Encoder Connection to MDV Movidrive® Drive Inverter


SEW recommends the high-resolution sin/cos encoder ES1S, ES2S or EV1S for operation with the Movidrive® drive inverter.
Connect the encoder as follows:

ES1S / ES2S / EV1S max. 100 m (330 ft)


X15:
ES1R / ES2R / EV1R A (K1) BLU/WHT 1
WHT/BLU 6
A (K1)
B (K2) ORG/WHT 2 5
WHT/ORG 7 9
B(K2)
C (K0) GRN/WHT 3
WHT/GRN 8 6
UB ^ K1 K2 K0 K1 K2 K0 C (K0) 1
UB ^ A B C ABC UB BRN/WHT 9
WHT/BRN 5
GRY/WHT 4

Figure 1

It is also possible to connect TTL encoders with 24 VDC encoder supply (ES1R, ES2R, EV1R) directly to Movidrive®. Install the TTL
encoders in exactly the same way as the high-resolution sin/cos encoders.

SOUTHEAST MANUFACTURING MIDWEST ASSEMBLY CENTER WEST COAST ASSEMBLY CENTER


& ASSEMBLY CENTER 2001 West Main Street, Troy, OH 45373 30599 San Antonio Road, Hayward, CA 94544
1295 Old Spartanburg Hwy, Lyman, SC 29365 (937) 335-0036 Fax: (937) 222-4104 (510) 487-3560 Fax: (510) 487-6381
(864) 439-7537 Fax: (864) 439-7830

SOUTHWEST ASSEMBLY CENTER EAST COAST ASSEMBLY CENTER


3950 Platinum Way, Dallas, TX 75237 200 High Hill Road, Bridgeport, NJ 08014
(214) 330-4824 Fax: (214) 330-4724 (856) 467-2277 Fax: (856) 330-4724
IMPORTANT:
If you are using an HTL encoder ES1C, ES2C or EV1C, you must not connect the negated channels K1’ (A’), K2’ (B’) and K0’
(C’) to Movidrive®! All other connections are per Figure 1.

Use the “5 V encoder supply type DW11A” Movidrive® option (part number 822 759 4) if you have to connect an encoder with a
5 VDC encoder supply (ES1T, ES2T or EV1T) to Movidrive®. Connect the encoder as follows:

max. 5 m (16.5 ft)


BLU/WHT
DWI11A
X15: 1 A (K1) 1
6 WHT/BLU 6
A (K1)
2 B (K2) ORG/WHT 2
7 WHT/ORG 7
5 B(K2)

X1: MOVIDRIVE
1
9 GRN/WHT 6
3 C (K0) 3
8 WHT/GRN 8
C (K0)
6
1 9 UB BRN/WHT 9 9
5
5 WHT/BRN 5
4 GRY/WHT 4
N.C.

max. 100 m (330 ft)


ES1T / ES2T / EV1T
A (K1) BLU/WHT 1
WHT/BLU 6
A (K1) 5
ORG/WHT 9
B (K2) 2

X2: Encoder
B(K2) WHT/ORG 7
C (K0) GRN/WHT 3 6
UB ^ K1 K2 K0 K1 K2 K0 1
WHT/GRN 8
UB ^ A B C ABC C (K0)
UB BRN/WHT 9
WHT/BRN 5
GRY/WHT 4*

Figure 2

* Make the sensor connection at the encoder (terminal UB). Do not jumper on the DWI 11A.

Connection to MDS Movidrive® Drive Inverter


Connect the resolver as follows:
DFY max. 100 m (330 ft)
X15:
GRN/WHT
1 Ref.+ 3
WHT/GRN
2 Ref.- 8
ORG/WHT
3 cos+ 2 5
WHT/ORG 9
4 cos- 7
BLU/WHT
5 sin+ 1
WHT/BLU
6 sin- 6 6
1
BRN/WHT
7 N.C. 9
WHT/BRN
8 N.C. 5
GRY/WHT
9 TF/TH 4
10 TF/TH

Figure 3

For further information, please contact your local SEW-Eurodrive Sales Representative.

Printed in USA 2 01/14/03