General
These operating instructions are intended to aid in the proper connection of Encoders and/or Resolvers that are used with the
Movidrive® drive inverter. SEW has several pre-fabricated cables to make connections to Movidrive® easier.
9E00 0428 - 330’ Encoder/Resolver Cable with (1) angled male connector.
9E00 0410 - 100’ Encoder/Resolver Cable with (1) angled male connector
9E00 0412 - 50’ Encoder/Resolver Cable with (1) angled male connector
9E00 0414 - 25’ Encoder/Resolver Cable with (1) angled male connector
9E00 0415 - 6’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Used to connect Movidrive® to DWI11A.
9E00 0416 - 6’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Can be used to connect Movidrive® Master-Slave synchronous connection with
DRS11A.
9E00 0418 - 3’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Can be used to connect Movidrive® Master-Slave synchronous connection with DRS11A.
9E00 0419 - 1.5’ Encoder/Resolver Cable with (1) angled male and (1) angled female connector.
Can be used to connect Movidrive® Master-Slave synchronous connection with DRS11A.
Other related reference material that may be useful for connection, commissioning and project planning are:
SEW Encoder Systems Manual
Movidrive® System Manual
Movidrive® Synchronous Operation Type DRS11A Manual
Figure 1
It is also possible to connect TTL encoders with 24 VDC encoder supply (ES1R, ES2R, EV1R) directly to Movidrive®. Install the TTL
encoders in exactly the same way as the high-resolution sin/cos encoders.
Use the “5 V encoder supply type DW11A” Movidrive® option (part number 822 759 4) if you have to connect an encoder with a
5 VDC encoder supply (ES1T, ES2T or EV1T) to Movidrive®. Connect the encoder as follows:
X1: MOVIDRIVE
1
9 GRN/WHT 6
3 C (K0) 3
8 WHT/GRN 8
C (K0)
6
1 9 UB BRN/WHT 9 9
5
5 WHT/BRN 5
4 GRY/WHT 4
N.C.
X2: Encoder
B(K2) WHT/ORG 7
C (K0) GRN/WHT 3 6
UB ^ K1 K2 K0 K1 K2 K0 1
WHT/GRN 8
UB ^ A B C ABC C (K0)
UB BRN/WHT 9
WHT/BRN 5
GRY/WHT 4*
Figure 2
* Make the sensor connection at the encoder (terminal UB). Do not jumper on the DWI 11A.
Figure 3
For further information, please contact your local SEW-Eurodrive Sales Representative.