Details of Joint Groove For Transverse Joints: Detail Detail
Details of Joint Groove For Transverse Joints: Detail Detail
5 ±1
sealant
' .. •
,.
'. Bond breaker tape
1.------ Leave Initial
saw cut as void ,. Leave as void
J 3mm approx.
(see Note 1)
DETAIL A DETAIL B
(Contraction Joint for reinforced slabs) (Contraction Joint for unrein forced slobs)
Width Depth
Joint spacing W D
(m) (mm) (mm)
Joint spacing ~ 10 10
5 ± 1 mrrl-~
5 ± 1 mm
j LlOmm
DETAIL c DETAIL D
(Expansion Joint> (Isolation Joint)
Notes:
1. Initial saw cut sholl be omitted when
slabs are not cast through the joint. A General Revision June 04
2. The depth of the joint sealant and bond
Former Drg. No. H1004A with general
breaker tape shall be in accordance with June 94
revision
the manufacturer's recommendations.
REF. REVISION SIGNATUR DATE
HIGHWA YS DEPARTMENT
DETAILS OF
REFERENCE DRAWING No. CAD
JOINT GROOVE FOR
TRANSVERSE JOINTS SCALE
DIAGRAMMATIC
H l109A