100% found this document useful (1 vote)
241 views2 pages

S2 - Floor / Roof: Design of Two - Way Slab With Provision For Torsion at Corners

This document provides details on the design of a two-way slab with torsional reinforcement at the corners. Key details include: - The slab has short and long spans of 4200mm and 5000mm respectively. - Loads include self-weight, finishes, partitions, and services totaling 7.35 kN/m^2 for dead load and 2.0 kN/m^2 for live load. - Reinforcement is calculated for short and long spans with T10 bars at 125mm and 200mm spacings respectively to satisfy bending and torsion. - Deflection and permissible span-to-depth ratios are checked and found to be within allowable limits.

Uploaded by

Muhammed Sabah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
241 views2 pages

S2 - Floor / Roof: Design of Two - Way Slab With Provision For Torsion at Corners

This document provides details on the design of a two-way slab with torsional reinforcement at the corners. Key details include: - The slab has short and long spans of 4200mm and 5000mm respectively. - Loads include self-weight, finishes, partitions, and services totaling 7.35 kN/m^2 for dead load and 2.0 kN/m^2 for live load. - Reinforcement is calculated for short and long spans with T10 bars at 125mm and 200mm spacings respectively to satisfy bending and torsion. - Deflection and permissible span-to-depth ratios are checked and found to be within allowable limits.

Uploaded by

Muhammed Sabah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Project: Page - 1 of 2

Design of two -way slab with provision for torsion at corners :


As per BS 8110 : Part I :1997

Ref : Section 3.5.3 of BS 8110 : Part I : 1997

Slab Designation : S2 - Floor / Roof


Quick Check : OK for Deflection
Span :
Short span, Lx: 4200 mm Short steel - T10 @ 125
Long span , Ly: 5000 mm
Long steel - T10 @ 200
Loads :

2
Self wt. of slab : 3.75 kN/m - Assumed Slab thickness, D = 150 mm
2 3
Floor/roof finishes : 3.20 kN/m (Unit wt. of Conc. = 25 kN/m )
2
Partition walls : 0.00 kN/m
2
Other Services : 0.40 kN/m

2
Total Dead load (DL): 7.35 kN/m

2
Total Live load (LL): 2.00 kN/m

2
Ult. Load (1.4DL+1.6LL): 13.49 kN/m

Slab Analysis :

Ly/Lx = 1.19
- refer Table - 3.14, page - 31
Type of panel : 9 - Four Edges Discontinuous

Short span coeff, Bsx : Corresponding BM :


for negative BM : 0.000 at support = 0.00 kN-m/m (for short - top steel)
for positive span BM : 0.073 at mid span = 17.41 kN-m/m (for short - bottom steel)

Long Span coeff, Bsy : Corresponding BM :


for negative BM : 0.000 at support = 0.00 kN-m/m (for long - top steel)
for positive span BM : 0.056 at mid span = 13.33 kN-m/m (for long - bottom steel)

Page 1 S2
Project : 0.000 Page - 2 of 2

Slab No : S2 - Floor / Roof


Reinforcement Calculation :

Overall depth D : 150 mm Cover : 25 mm


2
Effect.depth d : 120 mm Bar size (short) : 10 mm; (area of one bar = 79 mm )
2
Bar size (long) : 10 mm; (area of one bar = 79 mm )
Calculation of reinforcements:
BM b d fy fck Mu pt req. Ast,reqd. Min.Ast Ast provided Ast,provd.
bd2 % mm
2
mm2 dia @ spac mm
2

Short steel :
bottom: 17.405 1000 120 460 35 1.21 0.288 346 195 10 @ 125 628
top: 0.000 1000 120 460 35 0.00 0.000 0 195 10 @ 125 628

Long steel :
bottom: 13.326 1000 110 460 35 1.10 0.262 288 195 10 @ 200 393
top: 0.000 1000 110 460 35 0.00 0.000 0 195 10 @ 200 393
Refer section - 3.4.4.4 (page - 20), BS8110.

Deflection Check :

Short span : 4200 mm


b= 1000 mm
d= 120 mm
2
fck = 35 kN/m
2
fy = 460 kN/m
Ult BM = 17.405 kN-m
2
Mu/bd = 1.209

pt reqd. = 0.288 %
2
As,reqd. = 346 mm
2
As,provd. = 628 mm
2
Service stress fs = 169 N/mm ; fs = 2/3 fy (Ast reqd/Ast provd) / bb, where bb = 1.0

2
Modification Factor for Tension MF = 0.55 + (477 - fs)/(120 x [0.9 + Mu/bd ]) - Limited to 2.0
Reinf., MF : 1.77 - Refer Table-3.10

Permissible L/d ratio : Basic L/d x Modification for Tension steel

Perm. L/d = 20 X 1.77

Perm. L/d = 35.36

Actual L/d ratio = 35.00 - SAFE

Page 2 S2