0% found this document useful (0 votes)
447 views4 pages

Winload Calculation NSCP

This document calculates wind loads for a main wind force resisting system (MWFRS) based on the National Structural Code of the Philippines 2015 and ASCE7-05. It provides wind load parameters such as type of structure, exposure, velocity, and directionality factor. It then calculates wind pressures for the windward wall, leeward wall, and sidewalls based on height and pressure coefficients. Windward roof pressure is also calculated based on roof height and pressure coefficient.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
447 views4 pages

Winload Calculation NSCP

This document calculates wind loads for a main wind force resisting system (MWFRS) based on the National Structural Code of the Philippines 2015 and ASCE7-05. It provides wind load parameters such as type of structure, exposure, velocity, and directionality factor. It then calculates wind pressures for the windward wall, leeward wall, and sidewalls based on height and pressure coefficients. Windward roof pressure is also calculated based on roof height and pressure coefficient.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Calculation on the Wind Load for MWFRS

based on NSCP 2015 and ASCE7-05


Wind Load Parameters
Type : Enclosed
Exposure = B B= 46 m
V= 200 kph L1= 23 m
I= 0.87 L2= 23 m
Kd = 0.85 h= 7.6 m
Kzt = 1.00 θ= 10 ᵒ

qz= 1.42 Kz
h' = 4.06 m
hT= 9.63 m
Kz = 0.711

qh = 1.01 kPa
G= 0.85
Gcpi= 0.18 or -0.18
P = 0.85 q Cp ± 0.182

Windward Wall Cp = 0.8


h (m) Kz qz P1 (kPa) P2 (kPa)
4.6 0.576 0.82 0.3758 0.74
6.1 0.624 0.89 0.4234 0.79
7.6 0.665 0.94 0.4574 0.82
9.63 0.711 1.01 0.505 0.87

Leeward Wall (pressure is assumed constant with height "h")


L/B = 1 Cp = -0.5
P1 = -0.61 kPa P2 = -0.25 kPa

Sidewalls (pressure is assumed constant with height "h")


Cp = -0.7
P1 = -0.78 kPa P2 = -0.42 kPa

Windward Roof
h/L = 0.21 Cp =
Calculation on the Wind Load for MWFRS
based on NSCP 2015 and ASCE7-05
Calculation on the Wind Load for MWFRS
based on NSCP 2015 and ASCE7-05

21
0.
0.42 0.46

-0.61
0.3758

Windload Case A
Calculation on the Wind Load for MWFRS
based on NSCP 2015 and ASCE7-05