This document provides specifications for a temperature indicator with alarm outputs. It includes details about input types and ranges, output types including current, voltage, and alarm relays, mounting, terminal connections, communication protocols, and environmental specifications. The front panel has buttons for navigation, incrementing, decrementing, and acknowledgement. The display is 5 digits and 0.56 inches for the process value and parameter names. Accuracy is 0.1% of full span plus 1 count for thermocouple, RTD, and linear inputs.

Uploaded by

Puneet Bachal
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
451 views

409 M Quick User Guide

This document provides specifications for a temperature indicator with alarm outputs. It includes details about input types and ranges, output types including current, voltage, and alarm relays, mounting, terminal connections, communication protocols, and environmental specifications. The front panel has buttons for navigation, incrementing, decrementing, and acknowledgement. The display is 5 digits and 0.56 inches for the process value and parameter names. Accuracy is 0.1% of full span plus 1 count for thermocouple, RTD, and linear inputs.

Uploaded by

Puneet Bachal
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Quick User Guide Output Types MOUNTING DETAILS data loss or permanent damage to the instrument.

Use of
409 Retransmission Output snubber circuits across loads as shown above, is
Output Signal recommended.
DC Current 4-20mA/ 0-20mA FRONT PANEL DESCRIPTION
DC Voltage 0 to 10 V , 0 to 5V , 1 to 5V
Symbol Function
Load resistance
For Current o/p <500Ω It is used to come out from the main or sub
For Voltage o/p >2KΩ menu.
Output accuracy ±0.25% of FS
It is used to select the desired parameter in
Alarm Output various operating Mode. After setting the data
Relays 2 Nos. to proper value, by increment or decrement
Type Single Change over (C, NO, NC) key, it is used to enter the value of the
Temperature Indicator With Alarm selected parameter in memory.
Rating 5A @ 230VAC / 30VDC
SPECIFICATIONS It is used as an acknowledgement key for
Latching of alarm in Run mode.
Loop Power Supply
Input Input
Range Range Supply Voltage 24VDC (±10%) @26mA It is used to increment the parameter for
type type
selection. Value of Parameter can be
E -200.0 to 1000.0 ºC 0-2 V TERMINAL CONNECTION
Communication Details incremented by pressing this key. If the key is
J -200.0 to 1200.0ºC 0.4 – 2V Communication pressed continuously for more than 10 counts
K -200.0 to 1350.0ºC ± 10V Interface RS485 (2 Wire) change, the rate of increment will be made
T -200.0 to 400.0ºC 0-10 V faster. This facility is to allow faster data
Protocol Modbus-RTU
change for higher values.
B 450.0 to 1800.0ºC -10-20mV -19999 to 99999 Baud rate 4800,9600, 19200, 38400 bps
R 0.0 to 1750.0ºC ± 75 mV It is used to decrement the parameter for
Physical selection. Value of parameter can be
S 0.0 to 1750.0°C 0-75 mV
Dimension (H x W x D) mm 48 x 96 x 112 decremented by pressing this key. If the key is
Pt 100 -199.9 to 850.0 C O
0-400Ω
Front Bezel (H x W)mm 48 x 96 pressed continuously for more than 10 counts
4-20 mA 0-6000Ω change, the rate of decrement will be made
Panel Cutout mm 92x 46
0-20 mA -19999 to 99999 Depth Behind Panel mm 100 faster. This facility is to allow faster data
PV Write
0-5 V -19999 to 19999 Weight Approx. 260g. change for higher values. User presses during
Facility
1-5 V Enclosure Material ABS Plastic RUN mode for Thermocouple input it shows
*Use external 250ohms, 0.1% for current Input Enclosure Protection IP 20 ambient value.
Table 1.1 Terminal Cable Size 2.5mm2 LOAD CONNECTION
5 digit 0.56 inch RED Display.
Inputs Display process value. Display parameter
Accuracy Environmental Conditions PV
name when user set parameter. Display error
T/C,RTD & Linear + (0.1% of Full Span ± 1 count) TEMPCO message when an error occurs.
Input to PV Display < 100ppm
Resolution ADC: 17 bits,Display :0.1°C/1Count When alarm occurs respective alarm lamp will
Display to RX < 100ppm AL1
Sampling Rate 4 Samples/Sec on.
Humidity 20% to 95% RH
CJC Error ±2.0 °C
(Non-Condensing) When alarm occurs respective alarm lamp will
Sensor Burnout 0.5uA (Approx.) AL2
Ambient temperature 0 to 55°C on.
current
Storage Temperature 0 to 80°C Electrical precautions during use Tx ON when device is transmitting Data (RS-485).
RTD excitation 0.8mA (Approx.) Electrical noise generated by switching of inductive loads
current Power Supply can create momentary disruption, erratic display, latch up, Rx ON when device is receiving Data (RS-485).
Repeatability 0.05% of FS Standard 85-265VAC/ 100-300VDC
Response time < 1000ms Optional 18-36VDC ORDERING CODE
Power consumption <10 VA
Allowable wiring Maximum 15 ohms/wire (Conductor
resistance for resistance between three wires DIGITAL COMMUNIC- RETRANSMIS-
Isolation (Withstanding voltage) MODEL INPUT POWER SUPPLY
RTD should be equal) INPUT* ATION SION O/P
 Between primary terminals* and secondary terminals**:
NMRR > 40 dB 409 1 E F 0-5V N None 85-265VAC/ N NONE N None
At least 1500 V AC for 1 minute U1
CMRR >100 dB  Between primary terminals* and grounding terminal: 2 J G 0-10V Y Yes 100-300VDC Y RS485 C 4-20mA
Input Impedance 1MΩ(Approx.) for TC,RTD,0-2V, At least 1500 V AC for 1 minute 3 K H 0-2 V U2 18-36VDC D 0-20mA
0.4-2V,0-75mV, ±75mV,0-400Ω  Between grounding terminal and secondary terminals**: 4 T I 0.4 – 2V E 1-5V
220 kΩ for 0-10V, ±10V
At least 1500 V AC for 1 minute 5 B R ±75mV F 0-5V
440 kΩ for 0-5V, 1-5V, 0-6000 Ω
 Between secondary terminals**:
250Ω for 0-20mA,4-20mA 6 R U 0-75mV G 0-10V
At least 500 V AC for 1 minute
Max Voltage 20VDC 7 S V 0-400Ω
* Primary terminals indicate power terminals and relay * If Digital input is Yes, Retransmission o/p is not possible.
Display & Keys output terminals. 9 PT-100 W 0-6000Ω
PV Display 5-Digit, 7-Segment, 0.56” High, Red ** Secondary terminals indicate analog I/O signal and C 4-20 mA M Serial RS 485# # When Serial input type is selected, RS485 o/p needs to be selected.
Status Individual RED Led for Alarm & Communication O/P.
D 0-20mA S Special
Indication Communication Status Insulation resistance: 20MΩ or more at 500 V DC
E 1-5V
Keys Menu, Enter, Increase, Decrease between power terminals and grounding terminal.

Doc.Ref. No. m59A/QG/101 Issue No.:00 Page 1 of 2


SAFETY/WARNING PRECAUSTIONS RETRN Retransmi- Retransmission menu (CHANG) 0 to 9999 Depending up on condition set i.e. Latch Yes/No,
-
To ensure that the device can be operated safely and all (RETRN) ssion RETV/RETMA/RCAL *Parameter is only Shows if Input Type is Linear Acknowledge Yes/No or Trip refer table 1.1,1.2,1.3,1.4 in
functions can be used, please read these instructions Retransmi-
$
Parameter is only Shows if Input Type is TC Annexure-I.
RET V Set Voltage o/p #
Parameter is only Shows if Input Type is Serial
carefully. ssion 0-10V LL Logic
(RET V) 0-10V/0-5v/1-5V When 24V Signal applied momentarily at the DI terminal
Installation and Start-up must be carried out by qualified Voltage LL-low, Very low AL1-very low, AL2-low.
personnel only. Retransmi- (or Power OFF) then it will clear both values and same
RETMA Set Current o/p SP2>SP1
The relevant county-specific regulations must also be ssion 0-20 value will be stored in PV HI and in PV LO. Input is OPEN
(RETMA) 0-20/4-20 If PV<SP1 then => Relay 1-ON, Relay 2-ON
observed. Current then message OVER will be in PV HI and UNDER will be in
Relay 1-ON till PV>SP1+HYS1 after that Relay 1-OFF.
Before start-up it is particularly important to ensure: Retransmi- Retransmission PV LO. Note that during power on wait until all functionality
R CAL Relay 2-ON till PV>SP2+HYS2 after that Relay 2-OFF.
 Terminal wiring: check that all cables are correctly ssion Calibration Menu - initialized otherwise PV HI/LO values will be wrong.
(R CAL)
connected according to the connection diagram Calibration RTN Z/ RTN S ALARM OPERATION
 All wiring must confirm to appropriate standards of good 0.000 Alarm type
practice and local codes and regulations. Wiring must be RTN Z Retransmi- Calibration Zero for HH-Very high, high. AL1- Very high, AL2- high
(RET is
suitable for voltage, current and temperature rating of the (RTN Z) ssion Zero Retransmission o/p HL-high, low AL1-low, AL2-high.
0-10V)
system. LL-low, Very low AL1-very low, AL2-low.
10.000
 Unused control terminals should not be used as jumper RTN S Retransmi- Calibration Span for This setting is common for all groups.
(RET is
points as they may be internally connected, which may (RTN S) ssion Span Retransmission o/p Status of ALARM/TRIP
0-10V)
cause damage to the unit. It will toggle between ALARM and TRIP depending up on
Alarm Menu ATYPE selection in menu. ALARM mode is further subdivided into
PARAMETER SETTING ALARM Alarm /SELCT/LATCH/HYST/S Alarm with Latch and Alarm without Latch. Depending upon condition set i.e. Latch Yes/No,
-
Following parameters can view or change during run time. (ALARM) Parameter ENSR/SETp1/SETP2/RL TRIP is useful when the relay is used for tripping the plant Acknowledge Yes/No or Trip refer table 1.1,1.2,1.3,1.4 in
DLY/CTRlY or device and it is not to be started once again. Open Annexure-I.
 For Thermocouple input type, Press key to show ATYPE Set Alarm Type Open sensor UP scale/DOWN scale
Alarm Type LL condition is treated as normal condition in TRIP type.
ambient temperature (ATYPE) hh/hL/LL This is used to define the state of the alarms in OPEN
SELCT Select Select Alarm No Latching of ALARM
 Press and keys simultaneously will ask to enter Al1 sensor condition. It can be configured as UP Scale or
(SELCT) Alarm no. AL1/AL2 This is used for latching of discrete LEDs and relay status
password. On entering correct password, It will show OK DOWN Scale by keys. This condition works if and only if
when alarm limit is crossed. This option will keep discrete
AL1 Alarm 1 Set Logic for Alarm1 OPEN sensor condition occurs. Suppose ,UP scale has been
after that press key unit will show parameters. ALM LEDs/Relay latched even after channel has come to normal
(AL1) type ALM/TRIP selected and “HH” logic is there then during OPEN sensor
status until ENTER (ACK) key is pressed. This option can be
 Following parameters can be viewed using or Key. AL2 Alarm 2 Set Logic for Alarm2 condition Relay 1 & 2 will be ON and Lamp will be FLASH
ALM changed to YES or NO for enabling or disabling
(AL2) type ALM/TRIP as shown in table 1.1,1.2,1.3,1.4 in Annexure-I. if DOWN
Its value can be viewed using key and it can be respectively. When configurations of Alarms are of TRIP
LATCH Latch Select Latch logic is selected then relays and Lamp will be OFF.
no type, these parameters will be skipped from display.
changed using or Keys. (LATCH) Option YES/No HH Logic
HYST Hysteresis Value for HH Logic
Default Hysteresis 0. 1 HH- Very high, high. AL1- Very high, AL2- high.
Display Name Description (HYST) Relay-1 0.0 to 25.5 HH- Very high, high. AL1- Very high, AL2- high
Value In this logic if “UP Scale” condition has been selected than
Set PV input type Set Alarm o/p and in OPEN sensor condition ALARM 1 and ALARM 2 will be in
tC e/tC j/tC K/ tC SENSR Open Retransmission state the ABNORMAL condition and will work according to the
UP
t/tC b/tC r/ tC (SENSR) sensor when i/p Open following table 1.1,1.2,1.3,1.4 in Annexure-I. If “DOWN
INPUT INPUT s/pt100 /0-4K/ 0- Condition DoWN/UP Scale” Condition has been selected for this logic than in
1-5V SETP1 Range Depending on
(INput) Type 6K/1-10v /0-10V /0-5v Set Point-1 10.0 OPEN sensor condition ALARM 1 and ALARM 2 will be in the
/1-5V / 0-2v /.4-2V /- (SETP1) Input Type NORMAL State of operation.
10-20v/ 1-75/0-75 / SETP2 Range Depending on
Set point 2 10.0 HL Logic
SERL / 4-20 / 0-20 (SETP2) Input Type
HL-high, low AL1-low, AL2-high.
Set position of Decimal RLDLY Relay Relay Delay
*DP Decimal 0 In this logic if “UP Scale” condition has been selected than
Point on Display. .0 (RLDLY) Delay 0 to 9999
(dp) Point SP2>SP1 in OPEN sensor condition ALARM 2 will be in the
0/.0/.00/.000/.0000 CTRLY Control Set Control Relay If PV>SP1 but, less then SP2 => Relay1- ON, Relay2-OFF. ABNORMAL condition and ALARM 1 will be in the NORMAL
off
Can be set to any (CTRLY) Relay on/off condition will work according to the following table
If PV<SP1-Hyst1 => Relay1-OFF, Relay2-OFF.
ZERO value within the Input - COMUN Communic- Select Communication PV>SP2 => Relay1 and Relay2 both are ON. 1.1,1.2,1.3,1.4 in Annexure-I. If “DOWN Scale” Condition
Zero -
(zero) Range & less the SPAN 1999.9 (CoMUN) ation Menu Parameter SR-No/BAUD If PV<SP2-Hyst2 but, >SP1 => Relay1-ON, Relay2-OFF. has been selected for this logic than in OPEN sensor
Value. Unit ID for Depending up on condition set i.e. Latch Yes/No, condition ALARM 1 will be in the ABNORMAL condition and
SR-NO
Can be set to any Serial No Communication 1 Acknowledge Yes/No or Trip refer table 1.1,1.2,1.3,1.4 in ALARM 2 will be in the NORMAL condition and will work
(SR-No)
SPAN value within the Input 1 to 247 Annexure-I. according to table 1.1,1.2,1.3,1.4 in Annexure-I.
Span 9999.9
(span) Range & greater the Set Baud Rate
BAUD HL Logic LL Logic
ZERO Value. Baud Rate 4800/9600/19200/ 9600
(BAUD) HL-high, low AL1-low, AL2-high. LL-low, Very low AL1-very low, AL2-low.
Can be set to any 38400
1. 000 DI IP Digital Digital Input SP2>SP1 In this logic if “UP Scale” condition has been selected than
*INLO Input Low value within the Input -
(1- (DI IP) PV hi /PV Lo If PV>SP2 then Relay2-ON. in OPEN sensor condition ALARM 1 and ALARM 2 will be in
(inlo) Value Range & less the SPAN Input
5V) the NORMAL condition and will work according to the
Value. PVHI PV high Save Maximum Value
- following table 1.1,1.2,1.3,1.4 in Annexure-I. If “DOWN
Can be set to any (PV hi) Value of PV
5. 000 Scale” Condition has been selected for this logic than in
*INHI Input High value within the Input PVLO PV Low Save Minimum Value
(1- - OPEN sensor condition ALARM 1 and ALARM 2 will be in the
(inhi) Value Range & greater the (PV Lo) Value of PV
5V) ABNORMAL State of operation
ZERO Value. #TOUT PV Time Out
Time Out 1
CALIB Calibration Calibration Menu (ToUT) 1 to 32 For operation manual please visit www.masibus.com
-
(CALIB) Input CALS/CALZ/CALA *SQRT Square Square root of PV Specifications are subject to change without notice due to
no
*CALZ Calibration Calibration Zero for PV (SQRT) Root YES/No continuous improvements.
-
(CALZ) Zero Input FILT Digital Filter Value Masibus Automation And Instrumentation Pvt. Ltd.
Filter -
CALS Calibration Calibration Span for PV (FILT) 0 to 60 B-30, GIDC Electronics Estate, Sector-25, Gandhinagar-
-
(CALS) Span Input BRIHT Adjust Brightness 382044, Gujarat, India.
Brightness 100 If PV<SP2-Hyst2 => Relay2-OFF.
$CALA Calibration (BRIHT) 1 to 100 Tel:+91 79 23287275-79 Fax: +91 79 23287281
Ambient Adjustment PV<SP1 => Relay1 ON.
(CALA) Ambient - CHANG Password Set device Password 0 Web:www.masibus.com Email:[email protected]
If PV>SP1+Hyst1 then. Relay 1-OFF.
Doc.Ref. No. m59A/QG/101 Issue No.:00 Page 2 of 2

You might also like