Branch Leaflet KMC
Branch Leaflet KMC
Unit features......................................................................................................................................................................................... 1
Computerized control........................................................................................................................................................................... 3
Electrical data....................................................................................................................................................................................... 6
Dimension drawing............................................................................................................................................................................... 7
Electric installation............................................................................................................................................................................... 8
Product installation............................................................................................................................................................................... 9
KMC Series
Nomenclature
KMC-600LR
KMC-600LR
600RT adopts HFC134a 380V voltage water-cooled centrifugal chiller with total heat recovery.
Unit Features
Two-stage centrifugal compressor
According to the three-dimensional flow theory and the efficiency of HFC134a
under full load and part load condition to optimize the two-stage centrifugal
compressors. It can obtain the excellent operation performance, and also reduce
the unit operation surge point effectively.
Backward sealed impeller: perfect fluid dynamics model, precisely cast by
aluminum alloy.
Rigid ball bearing: realizes the demand on frequent start-stop.
Semi-hermetic motor: cooled by liquid refrigerant, drop the motor’s running
Two-stage centrifugal compressor
temperature, increase the efficiency and prolong service life.
The Von Mises stress analysis result The Von Mises stress analysis The cutaway view of the two-stage
when the second-stage impeller is in results when the secondary centrifugal compressor
running (side looking) impeller is in running(section)
2
Water-cooled Centrifugal Chiller
Compressor suction end
Evaporator
Evaporator is modified to enhance the heat transfer effect, improve system
evaporation temperature, increase unit cooling capacity and improve the efficiency
Liquid refrigerant
of the unit operation. Special technology of spray type internal structure design and
reasonable evaporation space can reduce evaporation resistance. Refrigerant liquid
can complete recycle without additional power by using the refrigerant flow control
circulating pump. The tube cluster in evaporator can fully infiltrated and improve
the heat transfer performance effectively even units are running without precisely
adjusting.
Jet pump
Compressor exhaustend
Condenser
The condenser is modified to make unit’s condensing temperature lower than the
general units and improve the unit efficiency through adopting the shell-and-tube
heat exchanger, and the strengthen pipe with low thread on the internal and external
surface, as well as the unique internal structure.
Economizer
3
KMC Series
Computerized Control
Microcomputer controller
Climaveneta centrifugal chiller is equipped with advanced
microcomputer controller and adopting the double CPU core
components to ensure the safe and stable operation of the unit.
Man-machine interface
Touch screen have its own storage space and a higher reaction rate so that user
can control the unit’s complete operation in a real time. User can make a choice
between Chinese and English language through intuitional operation interface,
just clicking on the picture to operate and set units.
4
Water-cooled Centrifugal Chiller
Cooling capacity kW 1759 1934 2109 2285 2462 2813 3165 3516 3868 4220 4571 4923
Power input kW 302 332 363 392 419 483 544 604 666 725 784 845
kW/kW 5.82 5.82 5.82 5.82 5.87 5.82 5.82 5.83 5.8 5.82 5.83 5.83
Full load performance
kW/RT 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.61 0.60 0.60 0.60
Evaporator
Water flow 3
m /h 303 333 363 393 423 484 544 605 665 726 786 847
Inlet/outlet pipe DN 200 200 250 250 250 250 300 300 300 300 300 300
Condenser
Water flow m3/h 354 390 425 461 495 567 638 709 780 851 921 982
Inlet/outlet pipe DN 200 200 250 250 250 250 300 300 300 300 300 300
Dimension
A(Length) mm 3920 3920 4120 4120 4120 4570 4570 4570 4780 4780 4780 4780
B(Width) mm 2320 2320 2380 2380 2380 2550 2550 2550 2800 2800 2800 2800
C(Height) mm 2450 2450 2500 2500 2500 2900 2900 2900 2950 2950 2950 2950
Installation dimension
D mm 2944 2944 3114 3111 3111 3381 3381 3384 3384 3384 3384 3384
E mm 1800 1800 1800 1800 1800 2000 2000 2000 2300 2300 2300 2300
Hauled weight kg 9100 9600 10100 10600 11200 11800 12500 13200 14500 15500 16500 18000
Operating weight kg 10050 10550 11100 11700 12350 13100 14000 14800 16350 17500 18600 20000
HFC134a Charge kg 450 495 540 585 630 720 810 900 990 1080 1170 1260
Note:
1. Cooling mode: evaporator inlet/outlet water temp. 12/7℃; Condenser inlet/outlet water temperature 32/37℃
2. The standard water side pressure of evaporator and condenser is 1.0MPa, 2.0Mpa as optional.
3. Soft starter as optional, please consult local CLIMAVENETA office.
4. 6kV/6.6kV/10kV High voltage unit as optional, please consult local CLIMAVENETA office.
5
KMC Series
Electrical Data
Low-voltage -380V (Y-delta start)
Unit model F.L.I(kW) F.L.A(A) S.A(A)
Note:
Starting current is star locked-rotor current of direct start condition
F.L.I Full load power input at max admissible condition
F.L.A Full load current at max admissible condition
S.A starting current
6
Water-cooled Centrifugal Chiller
Dimension Drawing
Compressor
Economizer
Evaporator Condenser
Note:
1. The wiring of unit starter is top in top out.
2. Waterproof when wire the starter.
3. If other inlet/outlet wiring way is needed, please consult local CLIMAVENETA office.
7
KMC Series
Electric Installation
Note:
Water pump control cabinet is provided by customers.
Power line and control line need to be controlled separately and can not be set in the same slot.
Customer should supply all the line above.
8
Water-cooled Centrifugal Chiller
Note:
Water pump control cabinet is provided by customers.
Power line and control line need to be controlled separately and not allowed set in the same slot.
Customer should provide all the line above.
9
KMC Series
Product Installation
10
Climaveneta Italy:
36061 BASSANO DEL GRAPPA (VICENZA) ITALIA - VIA SARSON 57/c
TEL. +39 / 0424 509 500 (r.a.) - TELEFAX +39 / 0424 509 509
E-mail:[email protected] http://www.climaveneta.com
Climaveneta China:
No,88 Baiyun Road Xinghuo Developing Zone ,Shanghai,China Post Code:201419
TEL: +86-21-57505566 FAX: +86-21-57505797
E-mail:[email protected] http://www.climaveneta.com.cn
Climaveneta Hongkong:
Room 2003,CCT Telecom Building, 11 Wo Shing Street,Fotan,Shatin,N.T.,Hongkong
TEL: +852-26871755 FAX: +85-2-26873078
E-mail:[email protected] http://www.climaveneta.com
Climaveneta Vietnam:
6th Floor, Room 6.6B, Etown2, 364 Cong Hoa Street, Ward 13, Tan Binh District, Hochiminh City
TEL: +848 6262 9966 FAX: +848 6262 9977
E-mail: [email protected] http:// www.climaveneta.com
All specification and data are subject to change without notice B214 CCU/01-03-2015 EN-SH