MultiTherm OG-1® Tech Data
MultiTherm OG-1® Tech Data
MULTITHERM OG-1®
Open Systems High Flash Point
HEAT TRANSFER FLUID MultiTherm OG-1® is designed for use in MultiTherm OG-1® offers the benefit of
MultiTherm® offers the next generation of liquid-phase heat transfer fluid systems, having a high flash point of 455°F / 235°C.
heat transfer fluid for open-loop heat which are “open” to the atmosphere or It also offers the extra benefit of having a
transfer fluid systems. there is a possibility that the heat transfer higher Fire Point then most other heat
Purpose fluid in the expansion tank will come in transfer fluids. MultiTherm OG-1® has a
MultiTherm OG-1® is a hydrocracked contact with air. To reduce the oxidation Fire Point of 520°F / 271°C.
base oil combined with the latest process in an open-loop system,
MultiTherm OG-1® is enhanced with Benefits of MultiTherm OG-1®
proprietary oxidation inhibitor/stabilizer. ■ System heat transfer characteristics
MultiTherm OG-1® was designed to meet special oxidation inhibitors to prevent this
the rising and demanding requirements of oxidative degradation and deposits. last longer due to improved
liquid phase open-loop heat transfer fluid oxidation resistance
MultiTherm OG-1® heat transfer fluid is
system applications. ■ Excellent Thermal Conductivity
designed for a maximum film temperature
of 600°F / 316°C and a maximum system at high temperatures
Oxidation ■ Thermal Stability from improved
bulk temperature of 550°F / 290°C.
The most common form of contamination oxidation resistance reduces efficiency
is oxidation of the heat transfer fluid. Low Vapor Pressure robbing components such as coke
Excessive oxidation can create solids and MultiTherm OG-1® heat transfer fluid has a
high viscosity compounds that impair deposits and particulate build-up
very low vapor pressure. This is important ■ Longer oil life means less
system effectiveness. Oxidation and because fluid boil-off is an issue in
fluid boil-off are major problems when open-loop systems. The rate of boil-off of maintenance, process downtime,
using organic heat transfer fluids in an a heat transfer fluid is dependent on the less oil disposal, and reduced
open-loop systems. Oxidation produces fluid vapor pressure. The higher the vapor environmental waste
organic acids, which can polymerize and pressure, the greater the rate of fluid
create deposits. boil-off.
3223 Phoenixville Pike, Malvern, PA 19355 Toll-Free: 800-225-7440 • Direct: 610-408-8361 • Fax: 610-408-8365
PO Box 579, Devault, PA 19432 Web: www.multitherm.com • Email: [email protected]
OG-1.qxd 7/12/04 12:24 PM Page 2
MultiTherm OG-1®
PHYSICAL PROPERTIES
Specific Thermal Vapor
Temperature Density Viscosity
Heat Conductivity Pressure
°F °C Sp Gr lb/gal lb/ft3 cSt cP lb/ft-hr Btu/(lb-°F) Btu/(h-ft-°F) mm Hg psia
Warranty: MultiTherm® warrants that MultiTherm OG-1® conforms to the data set forth in this brochure. We present this information in good faith, but because we
cannot control or anticipate the many different conditions under which our information and product may be used, no other warranty, expressed or implied, is given.
3223 Phoenixville Pike, Malvern, PA 19355 Toll-Free: 800-225-7440 • Direct: 610-408-8361 • Fax: 610-408-8365
PO Box 579, Devault, PA 19432 Web: www.multitherm.com • Email: [email protected]
OG-1 7/04