Qprog
Qprog
5
CHAPTER 2...............................................................................................................................................6
GETTING STARTED................................................................................................................................ 6
Create New Program............................................................................................................................6
Start with Program on Disk..................................................................................................................6
Start with Program in Register.............................................................................................................6
CHAPTER 3...............................................................................................................................................7
PROGRAM............................................................................................................................................. 7
Load from Register................................................................................................................................7
Send to Register....................................................................................................................................7
Load from Disk......................................................................................................................................8
New........................................................................................................................................................8
Copy......................................................................................................................................................8
Delete....................................................................................................................................................9
Close......................................................................................................................................................9
History...................................................................................................................................................9
Exit........................................................................................................................................................9
CHAPTER 4.............................................................................................................................................10
CONFIGURATION................................................................................................................................. 10
Customer ID........................................................................................................................................10
Model..................................................................................................................................................10
General Options..................................................................................................................................11
Load Configuration.............................................................................................................................13
Save as Default....................................................................................................................................13
Create ROM Config............................................................................................................................14
Report Construction............................................................................................................................14
Total Sales File...................................................................................................................................16
Group File...........................................................................................................................................16
Department File..................................................................................................................................16
PLU File..............................................................................................................................................17
Tax File...............................................................................................................................................19
Clerk File............................................................................................................................................20
Salesperson File..................................................................................................................................21
Tender File..........................................................................................................................................21
Drawer File.........................................................................................................................................22
P.O. and R.A. File...............................................................................................................................22
Discount File.......................................................................................................................................22
Correction File....................................................................................................................................23
Foreign Currency File........................................................................................................................23
User Report File..................................................................................................................................24
Balance Functions File.......................................................................................................................24
Table Total File...................................................................................................................................24
Room Total File..................................................................................................................................26
Account Total File...............................................................................................................................27
Balance Item Blocks File....................................................................................................................29
Modifier File.......................................................................................................................................29
Electronic Journal File.......................................................................................................................29
Endorsement Messages File................................................................................................................31
Keyboard Levels File..........................................................................................................................31
Macro File...........................................................................................................................................32
QProg Rel 1.69 - 1-
Printed on 7-12-21
Menu File............................................................................................................................................32
Price Level File...................................................................................................................................33
Transaction Type File (not active yet)................................................................................................33
Special Itemizer File...........................................................................................................................34
Window Look Up File.........................................................................................................................34
Condiment Table File..........................................................................................................................34
Action Table File.................................................................................................................................35
Invoice File.........................................................................................................................................35
Clerk Interrupt File.............................................................................................................................36
German ELV File................................................................................................................................36
Levels Extra Keyboard File................................................................................................................36
CHAPTER 5.............................................................................................................................................38
FILES................................................................................................................................................... 38
General Info on Files..........................................................................................................................38
Print Options.......................................................................................................................................39
Entry Limitation..................................................................................................................................40
Total Sales File...................................................................................................................................40
Group File...........................................................................................................................................40
Department File..................................................................................................................................41
PLU File..............................................................................................................................................43
Tax File...............................................................................................................................................46
Clerk File............................................................................................................................................47
Salesperson File..................................................................................................................................48
Tender File..........................................................................................................................................49
Drawer File.........................................................................................................................................50
P.O. and R.A. File...............................................................................................................................51
Discount File.......................................................................................................................................52
Correction File....................................................................................................................................53
Foreign Currency File........................................................................................................................54
User Report File..................................................................................................................................56
Balance Functions File.......................................................................................................................57
Table Total File...................................................................................................................................60
Room Total File..................................................................................................................................61
Account Total File...............................................................................................................................62
Balance Item Block File......................................................................................................................64
Modifier File.......................................................................................................................................64
Electronic Journal File.......................................................................................................................65
Endorsement Messages File................................................................................................................65
Keyboard Level File............................................................................................................................66
Macro File...........................................................................................................................................66
Menu File............................................................................................................................................67
Price Level File...................................................................................................................................68
Transaction Type File (not active yet)................................................................................................69
Special Itemizer File...........................................................................................................................70
Window Look Up File.........................................................................................................................71
Condiment Table File..........................................................................................................................71
Action Table File.................................................................................................................................72
Invoice File.........................................................................................................................................74
Clerk Interrupt File.............................................................................................................................74
CHAPTER 6.............................................................................................................................................75
SYSTEM............................................................................................................................................... 75
System Parameters..............................................................................................................................75
-2- QProg Rel 1.69
System Options....................................................................................................................................91
Day of the Week Zones......................................................................................................................121
Day of the Month Zones....................................................................................................................121
Date to Date Zones...........................................................................................................................122
Receipt Header..................................................................................................................................122
Receipt Trailer..................................................................................................................................122
Graphic Header Logo.......................................................................................................................122
Graphic Bottom Logo........................................................................................................................122
Graphic Screen Logo........................................................................................................................122
Slip Header........................................................................................................................................123
Slip Trailer........................................................................................................................................123
Tare Table.........................................................................................................................................123
Fixed Texts........................................................................................................................................123
CHAPTER 7...........................................................................................................................................125
KEYBOARD........................................................................................................................................ 125
Keytable Screen.................................................................................................................................125
Keyboard Number.............................................................................................................................125
Keyboard Type..................................................................................................................................125
Edit Properties..................................................................................................................................126
Print Keyboard..................................................................................................................................127
Key Info.............................................................................................................................................127
CHAPTER 8...........................................................................................................................................129
REPORTING........................................................................................................................................ 129
Get Report.........................................................................................................................................129
View Report.......................................................................................................................................129
Delete Report....................................................................................................................................130
CHAPTER 9...........................................................................................................................................131
COMMUNICATION.............................................................................................................................. 131
Dial....................................................................................................................................................131
Hang Up............................................................................................................................................131
Backup Register Memory..................................................................................................................131
Restore Register Memory..................................................................................................................131
Settings..............................................................................................................................................132
CHAPTER 10.........................................................................................................................................134
HELP................................................................................................................................................. 134
About.................................................................................................................................................134
Introduction
This manual describes how to program the Quorion cash registers using the programming tool called QProg. This
tool is especially developed by Quorion Data Systems for this purpose. As you will experience using this tool will
save you a lot of time now and also in the future. The current version is 1.69.
Getting Started
This chapter describes how to start using the QProg programming utility. It will describe how to start with a
completely new program, load an existing program from disk or load a program from a cash register.
Program
This chapter describes in detail the options in the Program Menu. Note that some menu options can’t be selected
when there is no application program loaded. When an application program is loaded the name, location and
program size are shown on the bottom line of the main QPROG screen.
Send to Register
When an application program is loaded in the working memory this menu option can be used to sent the complete
application program or only the changes to a register connected to your computer.
All Changes
Whenever a change is made to the application program it is recorded in a file with the program name and
extension QUP. With this option you can sent ALL the changes recorded in this file since the last time the file was
cleared to the register. Because it is required that the application program in the register is the same as the one
loaded in the working memory QPROG will check if they are the same. When they are different an message is
given and the update is not done.
NOTE:
When using scan codes for the articles care should be taken that all article programming is done using
QPROG because the file in the register must be the same as the one in QPROG. When you are not sure
it is better to take the Article Report and clear the file in the register first.
NOTE:
When using scan codes for the articles care should be taken that all article programming is done using
QPROG because the file in the register must be the same as the one in QPROG. When you are not sure
it is better to take the Article Report and clear the file in the register first.
Install Program
With this option you can install an application in a register. QPROG will check if the there is enough memory
installed in the register and then clear the complete memory before it will install the application in the register.
NOTE:
This option will CLEAR the complete memory of the register so all stored information stored is lost!!
New
When you select this menu option the Configuration screen will be shown. In this screen you can set up the
parameters for a new program. QPROG will calculate the memory required using the specified parameters like
number of Groups, Departments, PLU, Tendering Functions, Report Constructions etc.. For more details on the
individual parameters and file constructions please refer to the Help on CONFIGURATION. Once you have set all
the parameters to the desired values or just use the default ones exit the screen by selecting the OK button. You
will be prompted for the name of your new application, the default name is WQAPP.QAP. Note that there is no
need to enter the file extension QAP because QPROG will automatically create all the required files.
Copy
This menu option can be used to make a copy of a previously stored application program. This can be useful
when you already have a library of application programs and want to use an existing application as a base for a
new one. In this way you don’t have to enter all file and configuration data again.
After selection QPROG will show you all the programs stored in the selected directory (program files with
extension QAP) you will be able to select the program you want to copy. After selection QPROG will ask you the
-8- QProg Rel 1.69
name and location of the new program. When confirmed QPROG will copy all the application program files.
Before copying the Article (PLU) file it will ask if it should copy the file or only clear the file.
When copying a program in most cases the article file will be different so in order to avoid deleting all articles
manually you can clear the complete file directly.
Delete
This menu option can be used to delete a complete application or only the file with the program changes.
Application
After selection QPROG will show you all the programs stored in the selected directory (program files with
extension QAP) you will be able to select the program you want to delete. After selection QPROG will delete the
application program and all related files. When you are deleting the program which is currently loaded in the
working memory it will also be removed from the working memory.
Update File
When an application program is loaded in the working memory it is possible to manually delete the file with all the
program changes. This file is used when the menu option PROGRAM-> SEND TO REGISTER-> UPDATES is
selected. Note that after sending the changes to a register you will be asked if you want to delete the update file.
Close
Selecting this option will remove the currently loaded application program from the working memory.
History
QPROG keeps track of the last 4 programs loaded and allows you to select them directly in the PROGRAM
menu.
Exit
Selecting this option will exit QPROG.
Configuration
An application program consists out of a configuration file and data files. In the configuration file is the layout and
size of the data files is specified. This chapter describes in detail the options in the Configuration Menu.
Customer ID
Here you can set a CUSTOMER ID which is used by QPROG to protect the Customer application in the cash
register and in QPROG (QMP Release XX040730 or newer) from unauthorized access.
- When set you can only access the cash register by computer when the correct
CUSTOMER ID is set.
- When an application which has a CUSTOMER ID is loaded from DISK you will be
asked for the CUSTOMER ID.
- When the entered ID is not corrected you are not allowed to open the application.
- When an application is loaded in QPROG the CUSTOMER ID of the application will
be used during communication.
- When NO APPLICATION is loaded QPROG will ask you for the CUSTOMER ID
before every communication command.
- After an application is installed in the register you can only change the Customer ID in the register by
programming mode 98 (lock in P) or by making a hardware reset. It is not possible to CHANGE the ID
using QPROG.
Model
Here you can select the model for which you are creating an application program. It is possible to convert from
QMP3000 to CR1000 but the program will automatically remove all functions which are not supported by the
CR1000 and the changes cannot be undone! Note that there is NO check on the model when installing the
program in the register but when the model doesn’t match the model as specified in the configuration the program
will NOT work.
General Options
In this menu you can activate General Options which require memory.
Time Zones
Specifying the number of Time Zones in the program. The maximum is 48 which makes it possible to divide a day
into 48 zones of half an hour. When you want to divide the day in less Time Zones it is advised to lower the
number of zones to save memory in the Report Database. Time zones are used to report information which is
linked to a specific time zone. When the register starts a transaction it reads the real time clock and selects the
Time Zone for the current time and updates the totals in the report database for this time zone. In this way it is
possible to create special reports which report the sales in specific time zones and then do sales analysis based
on this information.
Prices of 12 Digits
When activated and FLASH ROM 021216 or later is installed in the register the maximum price size can be 12
digits when activated. Standard the register supports prices of 9 digits or when more then 5 price levels are active
8 digits! Note that this feature was especially made for INDONESIA and is NOT required in other countries. When
you don’t need prices of 12 digits it is advised NOT to activate this option because it will INCREASE the
application program size. When the option for Prices of 12 digits is set it will have the following consequences:
- Size of application program will be increased so the prices can be stored. It will have influence on the BALANCE
- Files (totals and items), Clerk Interrupt Buffers and the PLU file.
- The MAXIMUM number of PRICE levels is 15!
- You must not forget to set the Report Totals to 14 Digits or more!
- You cannot combine registers WITH and WITHOUT prices of 12 digits in a network. If you need 12 digit prices
you MUST activate it in all registers in the network and install this FLASH ROM version or newer in ALL registers.
The NRGT can be reset by entering 666666 on the TYPE key with the Central Lock in the P (Program) position.
Note that the NRGT is also reset when a SYSTEM INIT is done or when the application program is INSTALLED
using QPROG.
example1:
User Report 1 -> User Report 1 Period 1 (with shifting in Z)
User Report 21 -> User Report 1 Period 2
User Report 41 -> User Report 1 Period 3
User Report 61 -> User Report 1 Period 4
example2:
User Report 12 -> User Report 12 Period 1 (with shifting in Z)
User Report 32 -> User Report 12 Period 2
User Report 52 -> User Report 12 Period 3
User Report 72 -> User Report 12 Period 4
When a PERIOD 1 User Z-report is taken the register will shift the periods as follows:
1 - Add period3 to period4.
2 - Move period1 to period3.
3 - Clear period1.
Customer Count
Specifying the general maximum size of the report counters used for the customer count for every individual
period.
Quantity
Specifying the general maximum size of the report counters used for the quantity counter for every individual
period.
Amount
Specifying the general maximum size of the report counters used for the amounts for every individual period.
NOTE1:
When foreign currencies are used it might be necessary to increase the amount size incase !!
NOTE2:
When Price of 12 DIGITS are used the amount sizes should be 12 digits or more!
Load Configuration
When you are creating a new application program (MENU option: PROGRAM-> NEW) an extra button will be
shown which enables you to load a configuration file from an application stored on disk. After selection QPROG
will show you all the configuration files stored in the selected directory (program files with extension QAP) and you
can select the configuration you want to load. After selection QPROG will load the selected configuration in the
configuration menu. When you are creating an application from a stored configuration file the difference with
copying is that it will generate default functions and texts instead of copying them from the stored application.
Save as Default
Save the current configuration and text tables as default for creating a new application. Note that there is only
ONE default possible. Another way of creating a new application is by copying an existing application program
and modifying it or be loading a configuration file from an application stored on disk.
Totalizers
One report total for one period consists out of maximum 8 totalizers, which can be activated by marking the
checkbox. The totalizers can be split up into two groups. The totalizers in the first group are customer count,
quantity and amount and are used for both functions and sales totals. The totalizers in group two are return
quantity, discount, surcharge, tax and cost and are only used for sales totals. In addition to these ‘hard’ totalizers
the are also ‘soft’ totalizers which are calculated using the hard totalizers. Some ‘soft’ totalizers are profit and
gross sales.
GROUP 1 TOTALIZERS:
Customer Count:
Counts the number of customers for this total.
Quantity Count:
Counts the quantity for this total, which means for functions the number of times used and for sales totals the
number of items.
Amount:
Counts the ‘net’ amounts for this total.
GROUP 2 TOTALIZERS:
Return Quantity:
Counts the number of returned items and is only affected by a CORRECTION FUNCTION of the type REFUND.
Discount:
Counts the negative discount amounts and is only affected by NEGATIVE DISCOUNT FUNCTIONS.
Surcharge:
Counts the surcharge (positive discount) amounts and is only affected by POSITIVE DISCOUNT FUNCTIONS.
Tax:
Counts the TOTAL TAX amounts.
Cost:
Counts the Total Cost price. Note that you MUST use COSTPRICES when you activate this totalizer.
Periods
It is possible to store a Total for a maximum of 4 periods and it is even possible to change the Totalizer
construction for each period by marking the corresponding checkbox. In this way it is possible to save memory
when only specific Totalizers are interesting for a period. Depending on when the period report is taken it is a
daily, weekly, monthly or yearly report but in general period 1 is used for daily, period 2 for weekly, period 3 for
monthly and period 4 for yearly reports.
Standard
The Standard Pointer is the basic pointer, which means this pointer is always active, and there is only ONE. All
totals which are activated are always updated for the Standard Report. This pointer is used for reports, which
don’t need to be specified by another pointer like clerk, salesperson or Real Time Clock related pointers.
Clerk
It is possible to store sales and/or function totals for each individual clerk. A clerk is selected manually by pushing
a button or inserting a clerk key. This means that the activated totals are only updated for the active clerk so you
can see in the report what a specific clerk has done. When you add for one specific total all individual clerk totals
Salesperson
It is possible to store sales and/or function totals for each individual salesperson. A salesperson is selected
manually by pushing a button or for example swiping a card. This means that the activated totals are only
updated for the active salesperson so you can see in the report what a specific salesperson has done. When you
add for one specific total all individual salespersons totals the result should match the same total in the Standard
Pointer Report. Note that activating a lot of totals will consume a lot of memory because for each salesperson
memory is required. For example when you have 10 salesperson and 50 departments and you store the totals for
2 periods memory is reserved for 10 x 50 x 2 is 1000 totals
Time Zones
It is possible to store sales and/or function totals for each specified time zone. A time zone is selected
automatically at the start of the transaction by reading the Real Time Clock. This means that the activated totals
are only updated for the active time zone so you can see in the report what was done in a specific time zone.
When you add for one specific total all time zone totals the result should match the same total in the Standard
Pointer Report. Note that activating a lot of totals will consume a lot of memory because for each time zone
memory is required. For example when you have 48 time zones and 10 groups and you store the totals for 2
periods memory is reserved for 48 x10 x 2 is 960 totals
Day of Week
It is possible to store sales and/or function totals for each specified day of the week zone. A day of the week zone
is selected automatically at the start of the transaction by reading the Real Time Clock. This means that the
activated totals are only updated for the active day of the week zone so you can see in the report what was done
in a specific day of the week zone. When you add for one specific total all day of the week zone totals the result
should match the same total in the Standard Pointer Report. Note that activating a lot of totals will consume a lot
of memory because for each day of the week zone memory is required. For example when you have 7 day of the
week zones and 10 groups and you store the totals for 2 periods memory is reserved for 7 x10 x 2 is 140 totals
Day of Month
It is possible to store sales and/or function totals for each specified day of the month zone. A day of the month
zone is selected automatically at the start of the transaction by reading the Real Time Clock. This means that the
activated totals are only updated for the active day of the month zone so you can see in the report what was done
in a specific day of the month zone. When you add for one specific total all day of the month zone totals the result
should match the same total in the Standard Pointer Report. Note that activating a lot of totals will consume a lot
of memory because for each day of the month zone memory is required. For example when you have 31 day of
the month zones and 10 groups and you store the totals for 3 periods memory is reserved for 31 x10 x 3 is 930
totals
Date to Date
It is possible to store sales and/or function totals for each specified date zone. A date zone is selected
automatically at the start of the transaction by reading the Real Time Clock. This means that the activated totals
are only updated for the active date zone so you can see in the report what was done in a specific date zone.
When you add for one specific total all date zone totals the result should match the same total in the Standard
Pointer Report. Note that activating a lot of totals will consume a lot of memory because for each date zone
memory is required. For example when you have 12 date zones and 10 groups and you store the totals for 3
periods memory is reserved for 120 x10 x 3 is 360 totals
File Description
The Total Sales file contains only ONE record and is used to store the caption for total sales and report
information which is specified by the report construction.
Caption Size
Specify the maximum size of the Total Sales descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Total Sales file. For more detailed
information please refer to CONFIGURATION->REPORT CONSTRUCTION in the manual or Help File.
Group File
Description and configuration of the Group file.
File Description
The Group file contains a record for each group and is used to store programming information (caption, etc.) and
report information which is specified by the report construction.
Number of Records
The maximum number of records in the Group File is 255. It is possible to set the number of Groups to ZERO,
which will result in an application program without Groups.
Caption Size
Specify the maximum size of the Group descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Group file. For more detailed information
please refer to CONFIGURATION->REPORT CONSTRUCTION in the manual or Help File.
Department File
Description and configuration of the Department file.
File Description
The Department file contains a record for each department and is used to store programming information
(caption, etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the Department File is 999. The application program always requires a
minimum of ONE department!!
Caption Size
Specify the maximum size of the Department descriptor (maximum is 25). When this caption size is ZERO the
caption of the GROUP is used. When the caption size of the group is ZERO the department number is printed.
Report Construction
Here you specify what report information the register should store in the Department file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
PLU File
Description and configuration of the PLU file.
File Description
The PLU file contains a record for each PLU and is used to store programming information (caption, etc.) and
report information which is specified by the report construction.
Number of Records
The maximum number of records in the PLU File is 50000. When PLU are not required you can set the number of
records to ZERO.
Caption 1 Size
Specify the maximum size of the first PLU descriptor(maximum is 25). This caption is always used for the receipt,
display. When this caption size is ZERO the caption of the department is used.
Caption 2 Size
Specify the maximum size of the second PLU descriptor(maximum is 25). When active this caption is used for
printing on the Kitchen Printer.
Code# Size
Specify the maximum size of the PLU code number (maximum is 16). When Random (or scan codes) are not
required specify a size of ZERO.
Price Size
Specify the maximum size of the PLU price (maximum is 4). The size specifies the number of BYTES reserved
for 1 price. The maximum prices depend on the number of BYTES reserved. See Below.
NOTE:
QProg Rel 1.69 - 17-
Printed on 7-12-21
Because of internal processing the maximum price also depends on the number of price levels used.
When using more then 1 and less then 6 price levels the maximum price is 999999999. When the number
of price levels is more then 5 the maximum price is: 99999999.
Price Levels
Specify the number of Price Levels. When prices of 12 digits are used the maximum is 15 else the maximum is
20.
Costprice Size
Specify the maximum size of the PLU cost price (maximum is 4). The size specifies the number of BYTES
reserved for 1 price. The maximum prices depend on the number of BYTES reserved. See also Price Size.
KP Selection
When you are planning to use kitchen printers in your application and you want to select the Kitchen Printer on
PLU level you must mark this option. When not marked the Kitchen Printer Selection is taken from the
department.
Group Selection
When you want to create some special report totals you can activate Group Selection in which the PLU should
report. Note that it will NOT report in the Total Sales!!
Individual Options
When you want to be able to program the Options on each individual PLU you must mark this options. If not
marked the Options are taken from the first department selection.
Tax Selection
When you want to be able to program the Tax Selection on each individual PLU you must mark this options. If not
marked the Tax Selection is taken from the first department selection. Note that the Tax File must be active!!
Entry Limitation
When you want to be able to program the Entry Limitation on each individual PLU you must mark this options. If
not marked the Entry Limitation is taken from the first department selection.
Report Construction
Here you specify what report information the register should store in the PLU file. For more detailed information
please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help File.
Tax File
Description and configuration of the Tax file.
File Description
The Tax file contains a record for each Tax Function and is used to store programming information (caption, rate,
etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the Tax File is 8. When you don’t need Tax calculation you can set the
number of record to ZERO. The tax selection is programmed in other functions and is selected automatically.
Caption Size
Specify the maximum size of the Tax descriptor (maximum is 25). If the caption size is set to ZERO the rate is
always printed.
Report Construction
Here you specify what report information the register should store in the Tax file. For more detailed information
please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help File.
File Description
The Clerk file contains a record for each Clerk and is used to store programming information (caption, rate, etc.)
and report clerk time report information which is specified by Time Report Periods and Payment Rates.
Number of Records
The maximum number of records in the Clerk File is 999. When you don’t need Clerks you can set the number of
records to ZERO.
Caption Size
Specify the maximum size of the Clerk descriptor (maximum is 25).
Secret Code
When you want to use a secret code for clerk selection you can activate the secret code. The secret code is fixed
to 8 hexadecimal digits. Note that when you want to use the DALLAS ibutton as clerk lock the secret code is also
used for identifying the DALLAS ibutton. When the Secret Clerk Code is not active in the application the last
hexadecimal digit of the 12 hex digit Serial Number is used as Clerk Number. In this way the maximum number of
clerks is 16 (0-F) and there are no unique keys!!
SignOn/Off Code
When you want to use SIGN ON/OFF and protect it by a special code you can activate the Sign On/Off code. The
Sign On/Off code is fixed to 8 hexadecimal digits. Clerk Sign ON/OFF information is also stored in Electronic
Journal so it can be extracted from the journal when read by the computer.
SignOn/Off Times
When you want to use Sign On/Off time registration you can specify here how many Sign On/Off times should be
stored. When you want to use Time Reports the minimum is 2 and the maximum is 16 times. The stored times
are printed and cleared when the clerk report is taken.
Salesperson File
Description and configuration of the Salesperson file.
File Description
The Salesperson file contains a record for each Salesperson and is used to store programming information
(caption, rate, etc.).
Caption Size
Specify the maximum size of the Salesperson descriptor (maximum is 25).
Secret Code
When you want to use a secret code for salesperson selection you can activate the secret code. The secret code
is fixed to 8 hexadecimal digits.
Tender File
Description and configuration of the Tender file.
File Description
The Tender file contains a record for each Tendering Function and is used to store programming information
(caption, options, etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the Tender File is 99. It is advised to program at least ONE Tender Function
so a started transaction can be closed.
Caption Size
Specify the maximum size of the Tender descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Tender file. For more detailed information
please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help File.
Drawer File
Description and configuration of the Drawer file.
File Description
The Drawer file contains a record for each Drawer Function and is used to store programming information
(caption, options, etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the Drawer File is 99. If you don’t want to report the drawer contents you can
set the number of records to ZERO.
Caption Size
Specify the maximum size of the Drawer descriptor (maximum is 25).
Cash Declaration
When you want to be able to do a cash declaration report you must activate this option so space is reserved to
store the declared totals.
QProg Rel 1.69 - 21-
Printed on 7-12-21
Report Construction
Here you specify what report information the register should store in the Drawer file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
File Description
The PORA file contains a record for each PORA Function and is used to store programming information (caption,
options, etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the PORA File is 99. If you don’t need Paid Out and Received On Account
functions you can set the number of records to ZERO.
Caption Size
Specify the maximum size of the PORA descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the PORA file. For more detailed information
please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help File.
Discount File
Description and configuration of the Discount file.
File Description
The Discount file contains a record for each Discount Function and is used to store programming information
(caption, options, rate, etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the Discount File is 99. If you don’t need Discount Functions you can set the
number of records to ZERO. In the function itself you can program whether the it is a discount (negative) or a
surcharge (positive) function.
Caption Size
Specify the maximum size of the Discount descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Discount file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
Correction File
Description and configuration of the Correction file.
Number of Records
The maximum number of records in the Correction File is 99. If you don’t need correction functions you can set
the number of records to ZERO. The type of the correction function can be freely assigned.
Caption Size
Specify the maximum size of the Correction descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Correction file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
File Description
The Foreign Currency file contains a record for each Foreign Currency Function and is used to store
programming information (caption, options, rate, etc.) and report information which is specified by the report
construction.
Number of Records
The maximum number of records in the Foreign Currency File is 99. If you don’t need Foreign Currencies you can
set the number of records to ZERO.
Caption Size
Specify the maximum size of the Foreign Currency descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Foreign Currency file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
File Description
The User Report file contains a record for each User Report and is used to store programming information
(caption, options, etc.) and the report links.
Number of Records
The maximum number of records in the User Report File is 99. If you don’t need User Reports you can set the
number of records to ZERO.
Caption Size
Specify the maximum size of the User Report descriptor size (maximum is 25).
File Description
The Balance Functions file contains a record for each Balance Function and is used to store programming
information (caption, options, etc.) and report information which is specified by the report construction.
Number of Records
The maximum number of records in the Balance Function File is 99. If you don’t need Balance Functions you can
set the number of records to ZERO.
Caption Size
Specify the maximum size of the Balance Function descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Balance Function file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
File Description
The Table Total file contains a record for each Table Total and is used to store programming information (caption,
options, etc.) and the table amount in the number of periods as specified.
Number of Records
The maximum number of records in the Table Total File is 10000. If you don’t need Table Totals you can set the
number of records to ZERO.
Text Size
Specify the maximum size of the one Text Line (maximum is 25). You can have more then one text line. See also
Text Lines.
Text Lines
Specify the number of Text Lines you want for each total (maximum is 6).
Amount Size
Specify the maximum size for the Table Totals (maximum is 16 digits).
Periods
Specify the number of periods for the table totals (maximum 4). When a table is closed only period 1 is cleared,
the other periods are only cleared by a report.
Store Discount
It is possible to assign a automatic Discount to a Balance. You must program the discount function# which should
be used the discount (rate or amount depends on function) and the exempt amount. The discount is given and
reported when the balance is paid. When the balance is below the exempt amount the discount is not given.
When Subtotal is pressed the register will display the subtotal including the discount.
Store Time
The time stored is the time of the register on which the balance was opened so when you are using the
BALANCE TIME system with floating balances you must be sure that the time on all register is set the same
when you time out the balance on another register.
Store SalesPerson
When activated you can program a salesperson for each balance. When the salesperson is set to ZERO it is not
selected the active salesperson is used. This fucntion can be used if you need detailed reporting on a balance or
range of balances.
File Description
The Room Total file contains a record for each Room Total and is used to store programming information
(caption, options, etc.) and the room amount in the number of periods as specified.
Text Size
Specify the maximum size of the one Text Line (maximum is 25). You can have more then one text line. See also
Text Lines.
Text Lines
Specify the number of Text Lines you want for each total (maximum is 6).
Amount Size
Specify the maximum size for the Table Totals (maximum is 16 digits).
Periods
Specify the number of periods for the room totals (maximum 4). When a room is closed only period 1 is cleared,
the other periods are only cleared by a report.
Balance Limit
When you want to set a limit on a room you can set the size maximum size of the limit amount (maximum 16
digits).
Store Discount
It is possible to assign a automatic Discount to a Balance. You must program the discount function# which should
be used the discount (rate or amount depends on function) and the exempt amount. The discount is given and
reported when the balance is paid. When the balance is below the exempt amount the discount is not given.
When Subtotal is pressed the register will display the subtotal including the discount.
Store Time
The time stored is the time of the register on which the balance was opened so when you are using the
BALANCE TIME system with floating balances you must be sure that the time on all register is set the same
when you time out the balance on another register.
Store SalesPerson
When activated you can program a salesperson for each balance. When the salesperson is set to ZERO it is not
selected the active salesperson is used. This fucntion can be used if you need detailed reporting on a balance or
range of balances.
File Description
The Account Total file contains a record for each Account Total and is used to store programming information
(caption, options, etc.) and the account amount in the number of periods as specified.
Number of Records
The maximum number of records in the Account Total File is 10000. If you don’t need Account Totals you can set
the number of records to ZERO.
Text Size
Specify the maximum size of the one Text Line (maximum is 25). You can have more then one text line. See also
Text Lines.
Text Lines
Specify the number of Text Lines you want for each total (maximum is 6).
Amount Size
Specify the maximum size for the Table Totals (maximum is 16 digits).
Periods
Specify the number of periods for the Account totals (maximum 4). When a room is closed only period 1 is
cleared, the other periods are only cleared by a report.
Balance Limit
When you want to set a limit on an account you can set the size maximum size of the limit amount (maximum 16
digits).
Store Discount
It is possible to assign a automatic Discount to a Balance. You must program the discount function# which should
be used the discount (rate or amount depends on function) and the exempt amount. The discount is given and
reported when the balance is paid. When the balance is below the exempt amount the discount is not given.
When Subtotal is pressed the register will display the subtotal including the discount.
Store Time
The time stored is the time of the register on which the balance was opened so when you are using the
BALANCE TIME system with floating balances you must be sure that the time on all register is set the same
when you time out the balance on another register.
Store SalesPerson
When activated you can program a salesperson for each balance. When the salesperson is set to ZERO it is not
selected the active salesperson is used. This fucntion can be used if you need detailed reporting on a balance or
range of balances.
File Description
The Balance Item Blocks file is used to store the individual items which are ordered on a balance (Table, Room or
Account). The file contains Item Blocks which can hold 10 different items each. When a balance is opened it gets
one Item Block. When more then 10 items are stored on the balance it will automatically get a new item block.
The assignment of blocks is dynamically so in theory one balance can use ALL the blocks. For example when you
have 10 tables and 20 blocks you can store 20 different items on each table or 200 different items on ONE table.
The moment a balance is paid and closed the occupied block are released.
Number of Records
The maximum number of records in the Balance Item Blocks File is 60000 and each record contains 1 block. If
you don’t need to store individual items on the tables, rooms and account you can set the number of records to
ZERO. Note that in this case it is not possible to print a detailed invoice.
File Description
The Modifier file contains a record for each Modifier Function and is used to store programming information
(caption, options, etc.).
Number of Records
The maximum number of records in the Modifier File is 999. If you don’t need Modifiers you can set the number of
records to ZERO.
Caption Size
Specify the maximum size of the Modifier descriptor (maximum is 25).
File Description
The Electronic Journal file contains a record for each line of information. The data can be stored as ASCII print
data or as binary data. The electronic journal can be printed/reset by User Report 101 or only reset by User
Report 102. From release 050415 it is also possible to take report 104 in X-mode which will only print the tickets
of the active clerk. It is possible to print the journal in 3 ways:
2 – Enter YY on the Multiply key (X) an then 101 on the report key.
Now the last YY tickets are printed.
3 – Enter 0 on the Multiply key (X) and then 101 on the report key.
Now the complete journal is printed. When this is done in Z position the Electronic Journal is cleared.
Number of Records
The maximum number of records in the Electronic Journal is 1000000. If you don’t need the Electronic Journal
you can set the number of records to ZERO.
Data Format
TEXT
The data in the Electronic Journal is stored as ASCII print data which is like a copy of a printed journal. When
stored in this format it can only be used to print or view the electronic journal. The record size depends on the
Text Size specified (17 or 19). In this format all print data can be stored so also reports can be stored.
BINARY
The data in the Electronic Journal is stored as binary data which is like a copy of the transaction buffer. When
stored in this format it can be used to print or view the electronic journal but also to re-call transactions. The
record size is 11 bytes and is fixed. In this format only transactions and special records can be stored.
GENERAL
- Each record uses 11 bytes but note that the minimum size of ONE transaction is 10
records. This depends on the application configuration like number of tax itemizers
etc.
- When set to BINARY the register will only store Transaction Receipts which increase the
receipt number in the Electronic Journal. So reports and programming information
are never stored.
QProg Rel 1.69 - 29-
Printed on 7-12-21
- When SYSTEM OPTION 151 (No Receipt# Increment with balance sales) is SET the
order tickets for balances are not stored only the invoices.
- The Articles in the Binary Journal are stored using their index number so when BARCODES are used deleting
and adding new items should be done after the journal is reset. When items are added or deleted before
the journal is reset it can result in wrong article descriptors when viewing or reprinting the journal. Note
that the prices are always correct because they are stored in the journal so canging item prices is
possible without resetting the journal.
VIEWING OR PRINTING
- Transactions can ony be reviewed when the Central Lock is in REG or MANAGER mode.
- The last transaction can be viewed by pressing the PAGE UP or LINE UP key when not
in viewing mode.
- The first transaction can be viewed by pressing the PAGE DOWN or LINE DOWN key
when not in viewing mode.
- You can view a specific transaction by entering the receipt number on the PAGE UP or
LINE UP key. The register will no look for the entered number.
- When in viewing mode the PAGE UP, PAGE DOWN, LINE UP and LINE DOWN keys
can be used to scroll through the journal.
- When in viewing mode the last two lines show the receipt information like number and
date.
- A copy of the transaction which is being viewed can be printed by pressing the
SUBTOTAL key when you are in MANAGER mode (Manager (Limited) Clerk or
Central Lock).
- When you are printing a copy of a Table Invoice the register will ALWAYS attach the Endorsement message
on the copy. (Required in Germany)
COMPUTER
- When the Electronic Journal is taken by computer the lines are formatted for 40
characters.
- When the computer takes report 103 the data if in a special format which can be easily
processed. (See journal.doc).
- It is NOT possible to sent back the Electronic Journal Report to the register because it is not stored binary.
CANCELLING
- When in MANAGER MODE (Central Lock) or MANAGER CLERK with ONLY Option 1-5
SET it is possible to cancel a transaction.
- The transaction being viewed can be CANCELLED by pressing the EC (Error Correction)
function. The register will issue a copy ticket with negative amounts and cancel the
transaction in the report. In the Journal the transaction will be changed to a TOTAL of
0.00.
- After the transaction is cancelled the register will display “CORRECTION” (Function Text)
and now you can enter a new transaction. When CLEAR is pressed first you can
abort and you need to cancel it again to enter a new transaction.
- Note that you can only enter a DIRECT transaction with the same or less articles.
- The entered transaction is updated in the reports and a ticket is issued.
- When cancelling an INVOICE TRANSACTION the register will UPDATE the INVOICE FILE .
Text Size
Specify the maximum size of one Electronic Journal text line. This only applies when the Data Format is TEXT.
When printing the journal the register can print multiple columns depending on the printer used. The register will
calculate the number columns which it can print on one line.
File Description
The Endorsement Messages file contains a record for each Message. The messages can be used to print special
information on the receipt.
Number of Records
The maximum number of records in the Endorsement Message File is 16. If you don’t need Endorsement
Messages you can set the number of records to ZERO.
Text Size
Specify the maximum size of the one Text Line (maximum is 40). You can have more then one text line. See also
Text Lines.
Text Lines
Specify the number of Text Lines you want for each message (maximum is 99).
File Description
The Keyboard Levels file contains a record for each Keyboard Level. The keyboard levels can be used to select a
different keyboard for lunch, dinner etc. The level can be selected by key or automatically.
Number of Records
The maximum number of records in the Keyboard Level File is 8. If you don’t need Extra Keyboard levels you can
set the number of records to ZERO.
Caption Size
Specify the maximum size of the Keyboard Level descriptor(maximum is 25).
Macro File
Description and configuration of the Macro file.
File Description
The Macro file contains a record for each Macro. A macro is a series of keystrokes which are automatically
processed when the macro is selected. It is programmable whether the macro is stored as key numbers or as
function codes and it is also possible to simulate central lock and clerk lock positions.
Number of Records
The maximum number of records in the Macro File is 99. If you don’t need Macro’s you can set the number of
records to ZERO.
Keystrokes
Specify the maximum number of keystrokes you want to store for one macro (maximum is 99). When in the
options of the macro is specified that functions codes are stored instead of key numbers the maximum of function
codes is keystrokes/2 because a function code is 2 bytes and a key number only 1.
Menu File
Description and configuration of the Menu file.
File Description
The Menu file contains a record for each Menu/Arrangement and is used to store programming information
(caption, options, items, etc.) and report information which is specified by the report construction. A Menu is a
number of items which are automatically registered when the menu is selected. It is also possible to report the
individual menu’s.
Number of Records
The maximum number of records in the Menu File is 99. If you don’t need Menu’s you can set the number of
records to ZERO.
Caption Size
Specify the maximum size of the Menu descriptor (maximum is 25).
Number of Items
Specify the maximum number of items you want to store for one menu (maximum is 12). An item consists out of a
quantity and a function code.
Report Construction
Here you specify what report information the register should store in the Menu file. For more detailed information
please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help File.
File Description
The Price Level file contains a record for each Price Level and is used to store programming information (caption,
options, etc.) and report information which is specified by the report construction. A Price Level can be selected
by a key or automatically. All items (PLU and Department) which are sold in the selected level will be reported.
When the selected Price Level is within the number of Price Levels as specified is the PLU file configuration the
selected price will be used in all other cases the entered price or Price #1 is used and the level can be used for
reporting and/or Tax Shifting.
Number of Records
The maximum number of records in the Price Level File is 99. If you don’t need Price Levels, Tax shifting or
Level reporting you can set the number of records to ZERO.
Caption Size
Specify the maximum size of the Price Level descriptor (maximum is 25).
File Description
The Transaction Type file contains a record for each Transaction Type and is used to store programming
information (caption, options, etc.) and report information which is specified by the report construction. A
transaction type is selected by a key and can be used to report take-away, drive thru and or eat-in.
Number of Records
The maximum number of records in the Transaction Type File is 99. If you don’t need Transaction Types you can
set the number of records to ZERO.
Caption Size
Specify the maximum size of the Transaction Type descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Transaction Type file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
File Description
The Special Itemizer file contains a record for each Special Itemizeri and is used to store programming
information (caption, options, etc.) and report information which is specified by the report construction. A special
itemizer is like a tax itemizer and can be used for special purposes like discounts and commission.
The special itemizer selection is programmed in other functions and is selected automatically.
Number of Records
The maximum number of records in the Special Itemizer File is 8. If you don’t need the Special Itemizers you can
set the number of record to ZERO.
Caption Size
Specify the maximum size of the Special Itemizer descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Special Itemizer file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
File Description
The WLU file contains a record for each Window Look Up screen. A Window Look Up screen contains a number
of functions codes of which the descriptor is shown when the WLU is selected. This function is only useful when a
multi-line display is installed.
Number of Records
The maximum number of records in the WLU File is 99. If you don’t need Window Look Up’s you can set the
number of records to ZERO.
Caption Size
Specify the maximum size of the WLU descriptor (maximum is 25).
Number of Items
Specify the maximum number of function codes you want to store for one WLU (maximum is 99).
File Description
The Condiment Table file contains a record for each Condiment Table. A Condiment Table contains a number of
functions codes of which the descriptor is shown when the Condiment Table is selected. Depending on the
programming you can force the user to make a selection on item level (see also Department and PLU file). It is
normally used to prompt the user to select a modifier or a side dish. It is also used to select items in a menu.
Number of Records
The maximum number of records in the Condiment Table File is 99. If you don’t need Condiment Tables you can
set the number of records to ZERO.
Caption Size
Specify the maximum size of the Condiment Table descriptor (maximum is 25).
Number of Items
Specify the maximum number of function codes you want to store for one Condiment Table (maximum is 99).
File Description
The Action Table file contains a record for each Action Table. An Action Table is used to give special discount
using different schemes. The Action Table contains the discount type and report information when activated.
Number of Records
The maximum number of records in the Action File is 99. If you don’t need Action Tables you can set the number
of records to ZERO.
Caption Size
Specify the maximum size of the Action Table descriptor (maximum is 25).
Report Construction
Here you specify what report information the register should store in the Action Table file. For more detailed
information please refer to paragraph “CONFIGURATION -> REPORT CONSTRUCTION” in the manual or Help
File.
Invoice File
Description and configuration of the Invoice file.
File Description
The Invoice file is used to store information on the invoices issued. The invoice number of 4 digits and the total
amount of the invoice is always stored and in addition to that it is possible to store the date, time and clerk of the
invoice. The Invoice file can be printed and/or reset by User Report 100. When the file is full it is required to print
and reset the file before a new invoice can be issued!! When OPTION 142 is SET the register will automatically
delete the first invoice from the file when the file is full and there is no need to take the report. It will always have
the last invoices issued.
Number of Records
The maximum number of records in the Invoice File is 10000. If you don’t need to store the issued Invoices can
set the number of records to ZERO.
Store Date
Is set then the Date the invoice is issued is also stored.
Store Time
Is set then the Time the invoice is issued is also stored.
Store Clerk
Is set then the clerk who issued the invoice is also stored.
File Description
The Clerk Interrupt file is used to temporarily store a transaction for a clerk. In this way more then one clerk can
work simultaneously on the cash register. When another clerk interrupts the transaction of the current clerk a
buffer in this file will be assigned to the current clerk in which the current transaction will be stored. When the
clerk is selected again the register will recall the transaction from the buffer.
Number of Records
The maximum number of buffer records in the Clerk Interrupt File is 99. If you don’t want to use the Clerk
Interrupt facility set the number of records to ZERO.
File Description
For Germany a special ELV report can be activated. When this file is activated the register will store all ELV
transactions in a file which can be reported by USER REPORT 110. General Message# 84 is used for the name
of the report. The report can also be taken by computer. The report will list all ELV transaction with the DATE,
TIME, TRANSACTION#, ACCOUNT, BANKCODE, EXPIRATION DATE and AMOUNT. See EFT_GER.DOC for
moe details.
Number of Records
The maximum number of ELV transaction record which can be stored. If you don’t need this special file set the
number of records to ZERO.
File Description
The Levels Extra Keyboard file contains a record for each Level of the Extra Keyboard Level. For the Concerto
the EXTRA keyboard is builtin and this file must have at least one record. The keyboard levels can be used to
select a different keyboard for lunch, dinner etc..
Number of Records
The maximum number of records in the Levels Extra Keyboard File is 8. If you don’t have an extra keyboard you
can set the number of records to ZERO.
Caption Size
Specify the maximum size of the Keyboard Level descriptor(maximum is 25).
Files
This chapter describes in detail the options in the Edit Files Menu.
Editing Files
FIRST COLUMN
The first column is used for marking the record for updating, creation or deletion. When a record is
changed the “*” character will appear in the first column to mark that it is changed. When the editing of the
file is closed by the OK button the changes will be permanent and are also recorded in the UPDATE file.
When using Scan Codes for Articles the column is also used for marking a NEW article with “++” or a
DELETED article with ‘—‘ characters.
ACTIVE COLUMNS
The number of active columns when editing a file depend on the configuration of the file. In the help file all
possible columns are listed but when a field is not activated in the configuration it will not be shown and
cannot be changed.
SCROLLING
When editing a file the records are shown in a row and columns format. When the number of rows or
columns don’t fit on the screen you can scroll horizontal or vertical by using the scroll bars.
SORTING
It is possible to sort the file you are editing on a specific column. You must select the column in SORT ON
box.
DIRECT ACCESS
It is possible to go directly to a record by entering the record number in the NUMBER box and press
ENTER.
CANCEL
All changes made are only updated the moment you exit by using the OK button so it is always possible
to cancel the changes by pressing the CANCEL button. The program will always ask you if you are sure
to cancel the changes.
CHECK BOX
In an option field you can just enter the options you want to activate (1 to 8) or click on the option check
box which will automatically appear on the right side of the screen when you enter the option column.
RANGE SELECTION
It is possible to select a Range by holding the left mouse button depressed and moving the mouse, by
right clicking the mouse or by clicking on the top of a column or left side of a row. When a range is
selected it is possible to Clear the selected range or Fill the selected range with the value of the first row
in the selection by right clicking the mouse. It is also possible to select a range for printing, importing or
exporting data.
Exporting Data
It is possible to export data to ASCII text files. In the List box the available fields are shown. When a range is
selected only the selected columns are marked and the checkbox “selection” is marked. It is possible to specify
the FIELD and TEXT separators and whether the field names should be exported on the first line.
Importing Data
It is possible to import data from ASCII text files. In the LEFT List box the available QPROG fields are shown.
When a range is selected only the selected columns are marked and the checkbox “selection” is marked. It is
possible to specify the FIELD and TEXT separators and whether if the first line of the imported file contains the
field names. When the first line contains the field names it is skipped when importing the data.
The RIGHT List box contains the fields QPROG was able to identify in the first line of the imported file. When
importing the data QPROG will put the data of the first selected field in the first selected field of the LEFT list box
and continue with the next fields. When the field containing the RECORD number is also imported QPROG will
put the data in the record as specified. When the record number is not selected QPROG will put the data in the
columns and rows as selected. When using PLU scan codes QPROG will create the PLU when the code is not
available.
Print Options
In the Print1 and Print2 Options it is possible to program the printer (and display) on which the function should
print and also the font type for the function. When the selected option is not available or setup in the application
the option will have no effect!
P2.1, P2.2 and P2.3 are used to specify the Font Type for the function. In most POS printers on the market it is
possible to select an internal font called FONT A and B when available the FONT A or B is selected. The register
will automatically format the data according to the type of printer installed. The following combinations are
possible:
Entry Limitation
It is possible to set an amount entry limitation on a department, PLU (if activated), tendering function, P.O. / R.A.
function and discount function. The value programmed in the entry limitation field is setup as XY, where X is the
most significant digit and Y the number of following ZEROES. For example when a limit must be set to 20000 the
value for X is 2 and the value for Y is 4 so the value which must be programmed is 24. When a value of 00 is
programmed there is do entry limit check, the maximum value of XY is 99 which is 9000000000.
NOTE 1:
Besides the programmed limit there is also an absolute limit of 999999999 on which is ALWAYS checked
and there is also ALWAYS a check on the maximum value which can be stored in the reports. This value
is programmed in the “Application Configuration -> Change Report Totalizer Sizes”.
NOTE 2:
When SYSTEM OPTION 187 is set and the Entry Limitation Field is Set to ZERO on the department (or
PLU when configured) the register will NOT ALLOW the entry of a NEW PRICE for the PLU with the limit
set to ZERO.
When the ENTRY is larger than the programmed, absolute or report totalizer limit the register will give ERROR 20
-> “Entry Too High !!”.
Caption
In this field you can enter the name of the Total Sales record which is used for the display and the printer. The
maximum length depends on the Total Sales File Configuration. When a longer name then allowed is entered only
the programmed length is stored in the file.
Group File
File Extension: appname.Q02
Function# Key code: not available
Direct Key code: not available
Caption
In this field you can enter the name of the Group which is used for the display and the printer. The maximum
length depends on the Group File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 Not used.
O1.2 Not used.
QProg Rel 1.69 - 39-
Printed on 7-12-21
O1.3 Not used.
O1.4 Not used.
O1.5 Not used.
O1.6 Not used.
O1.7 Not used.
O1.8 Not used.
Options2
O2.1 Not used.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Department File
File Extension: appname.Q03
Department# Key code: 5000
Direct Department Key code: 5000 + department#
Caption
In this field you can enter the name of the Department which is used for the display and the printer. The maximum
length depends on the Department File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Group
In this field you program the group link for the department. When you program a value of ZERO the department
will not be linked to a group and Total Sales.
Extra Group
When you want to create some special report totals you can activate a second Group in which the Department
should report.
Options1
O1.1 If SET then ZERO PRICES are not allowed.
O1.2 If SET then the prices are negative!
O1.3 If SET then the Department Key is also used as Window Key to list all linked PLU’s
O1.4 If SET then don’t shift TAX status when TAX SHIFT is used.
O1.5 If SET then SCALABLE
O1.6 If SET Print Weight Info Line (“1.234 kg @ 10.00/kg”) See also OPTION 133.
O1.7 If SET then the Department Key can ONLY be used as Window Key to list all linked PLU’s
O1.8 Single Item.
When set the department item will be SINGLE ITEM. When an department with this option SET is
registered as the first ITEM in a DIRECT SALE it will be automatically closed on TENDERING function
number 1.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 One Quantity Ticket on Kitchen Printer.
O2.3 Double Tickets on Kitchen Printer.
O2.4 If set it is not allowed to enter a quantity with decimal point.
O2.5 If set and 1.5 is set then compulsory Tare Selection.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
- 40 - QProg Rel 1.69
Entry Limitation
When required you can set an entry limitation on a department. See “FILE->ENTRY LIMITATION” for more
details.
Tax Selection
In this flag you program the Tax Selection for the department. It is possible to select more then one Tax Itemizer
at the same time. When the TAX file is not active in the application this field will not be shown and when a Tax
Itemizer which is not active is selected nothing will happen.
KP Selection
In this flag you program the Kitchen Printer Selection for the department. It is possible to select more then one
Kitchen Printer at the same time. When the Kitchen Printer Selection is not active in the Department File
Configuration this field will not be shown and when a Kitchen Printer which is not active is selected nothing will
happen.
Action Table#
When you want to use special discount actions on this department you can specify the Action table selection. It
will also apply to all PLU which select this department unless it is also selected on PLU level.
PLU File
File Extension: appname.Q04
PLU# Key code: 10000
Direct PLU Key code: 10000 + PLU#
Code#
In this field you program the scan code for the PLU. When you enter a scan code which doesn’t exist you will be
asked if you want to create it. When you want to delete a scan code you must press the DEL key and you are
asked if you want to delete the item. On the bottom of the screen you can see the maximum number of PLU
which can be stored and how many are already used. When a new item is created it will be marked in the first
column with “++”, when you delete an item in will be marked with “—“ and when you only change it it will be
marked with ‘*’.
Caption
In this field you can enter the name of the PLU which is used for the display and the printer. The maximum length
depends on the PLU File Configuration. When a longer name then allowed is entered only the programmed length
is stored in the file.
Extra Caption
In this field you can enter the name of the PLU which is used for the kitchen printer. The maximum length
depends on the PLU File Configuration. When a longer name then allowed is entered only the programmed length
is stored in the file.
Department
In this field you program the Department link for the PLU. When you program a value of ZERO the PLU will not
be active and will give ERROR 6. It will also not be printed in a PROGRAM DUMP on the register.
Extra Department
When you want to create some special report totals you can activate a second department in which the PLU
should report. Note that it will NOT report in the Group of the second department !!
Group
When you want to create some special report totals you can activate a second Group in which the PLU should
report.
Price (1-20)
Depending on the number of price levels in the configuration you can enter the prices here. Note that the check
on the maximum price is done when you exit the menu. Prices which are larger then the maximum price size in
the configuration are set to zero.
Link
When you want to link another PLU to this PLU you can enter the PLU number in this field. Note that the
maximum LINK number when random codes are used is 65535
Action Table#
When you want to use special discount actions on this PLU you can specify the Action table selection.
Condiment Table
When you want the register to prompt you for a Condiment Selection after you sell this PLU you can specify here
the condiment tables it should prompt for. When you sell a PLU the register will prompt you for the condiment by
showing the CONDIMENT window. The condiment option number corresponds with the Condiment Table# which
will be shown. When OPTION 1-1 in the Condiment table is set you MUST make a selection else you can abort
by pressing the CLEAR key. When a quantity bigger then ONE with no DECIMAL point is entered the register will
show you the selected modifier with the quantity and you MUST confirm by pressing the MULTIPLY (X) key
without entry or enter the required quantity on the MULTIPLY (X) key. When the entered quantity is no the same
as the itme quantity the register will prompt again for the modifier until the entered quantity is reached. After the
selection or pressing CLEAR the register will show the next condiment table when active. Note that in the
Condiment Table you must program the KEYCODE of the condiment you want to display. At the moment only
MODIFIERS (key code 4XXX) are supported!! ERROR MESSAGE# 49 (SELECT CONDIMENT) is given when
selection of a condiment is compulsory.
Inventory Quantity
In this field you can enter the inventory quantity for this PLU. Note that it will OVERWRITE the inventory which is
stored in the register. When you load the program from the register it will show the actual inventory status. It is
possible to link a PLU to an inventory PLU. This can be used to link for example a glass of wine to a bottle. Also
see SYSTEM OPTION 192 when you want to use a UNIT size other then 1 for the inventory. When you put in the
INVENTORY field the article code followed by ‘A’ the register will know that there is an inventory link.
Inventory Amount
In this field you can enter the inventory amount for this PLU. Note that it will OVERWRITE the inventory which is
stored in the register. When you load the program from the register it will show the actual inventory status.
Options1
O1.1 If SET then ZERO PRICE is not allowed.
O1.2 If SET then the price is negative!
O1.3 Not used.
O1.4 If SET then don’t shift TAX status when TAX SHIFT is used.
O1.5 If SET then SCALABLE
O1.6 If SET Print Weight Info Line (“1.234 kg @ 10.00/kg”)
O1.7 Not used.
O1.8 Single Item.
When set the item will be SINGLE ITEM. When an item with this option SET is registered as the first
ITEM in a DIRECT SALE it will be automatically closed on TENDERING function number 1.
Entry Limitation
When required you can set an entry limitation on an individual PLU. See “FILE->ENTRY LIMITATION” for more
details.
Tax Selection
In this flag you program the Tax Selection for this PLU. It is possible to select more then one Tax Itemizer at the
same time. When the TAX file is not active in the application this field will not be shown and when a Tax Itemizer
which is not active is selected nothing will happen.
KP Selection
In this flag you program the Kitchen Printer Selection for this PLU. It is possible to select more then one Kitchen
Printer at the same time. When the Kitchen Printer Selection is not active in the PLU File Configuration this field
will not be shown and when a Kitchen Printer which is not active is selected nothing will happen.
Caption
In this field you can enter the name of the tax function which is used for the display and the printer. The maximum
length depends on the Tax File Configuration. When a longer name then allowed is entered only the programmed
length is stored in the file.
Rate
In this field you enter the percentage rate for the tax function. The rate is always entered with 2 decimals and the
theoretical maximum rate you can enter is 42949672.95. Note that the decimal point is not entered. For example
when you want a rate of 19.00% you must enter 1900.
Exempt
When the tax type is set as ADDON you can program in this field an exempt amount. When the taxable itemizer
is below this amount no tax is calculated. The theoretical maximum amount you can enter is 4294967295. Note
that the decimal point is not entered. This means the amount is always enter in the smallest unit. For example DM
1,00 is entered as 100.
Options1
O1.1 TAX TYPE
SET
The type of TAX is ADDON and all prices are without tax. This type of TAX is printed and displayed
before the tendering function and is added to the sale amount.
NOT SET
The type of TAX is VAT and all prices are inclusive tax. This type of TAX is printed at the bottom of the
receipt and is not displayed.
O1.3 If SET then Singapore GST Calculation (Calculated on TOTAL SALES AMOUNT including taxes).
O1.4 If SET then Print Percentage in front of descriptor.
O1.5 If SET then don’t print taxable (net) amount.
O1.6 If SET then don’t print tax amount.
O1.7 If SET then also print tax and/or taxable when amount is zero.
O1.8 If SET then also print GROSS tax amount (Taxable+Tax).
Options2
O2.1 Combined VAT Itemizer. When SET the register will extract all VAT with this option SET before
calculating the VAT. Used when prices are including multiple VAT rates.
O2.2 NON-TAXABLE Itemizer. All SALES without TAX selection is added/reported in this total.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Clerk File
File Extension: appname.Q06
Clerk# Key code: 2000
Direct Clerk Key code: 2000 + Clerk#
Caption
In this field you can enter the name of the Clerk which is used for the display and the printer. The maximum
length depends on the Clerk File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 If SET this clerk opens Drawer 1.
O1.2 If SET this clerk opens Drawer 2.
NOTE: When drawer opening is selected by clerk OPTION in the functions Drawer 1 & 2 MUST be set
because a logical AND is done.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 If SET suppress Kitchen Printer Tickets for this Clerk.
O2.3 If SET manager with limited functionality. No Easy Programming and Cancel function.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 If SET then this clerk can only select RG and X position of the LOCK.
O2.8 If SET then this clerk is not allowed to select the P position of the LOCK. When also O2.7 is set this clerk
is NOT allowed to CHANGE to any position of the lock.
Secret Code
The secret code is fixed to 8 hexadecimal digits and must be entered when you want to select this clerk.
Note that when you want to use the DALLAS ibutton as clerk lock the secret code is also used for identifying the
DALLAS ibutton. When the Secret Clerk Code is not active in the application the last hexadecimal digit of the 12
hex digit Ibutton Serial Number is used as Clerk Number. In this way the maximum number of clerks is 16 (0-F)
and there are no unique keys!!
Price Level
It is possible to assign a Price Level to a Clerk. When activated you can program a level for each clerk. When the
level is set to ZERO it is not activated and the normal level is used. The level is used a a base level and disables
the level selected by the clock, balance or a level which is manually selected. Note that the shift on shift level still
works in the same way as when the base level is selected by the clock.
Salesperson File
File Extension: appname.Q07
Salesperson# Key code: 3000
Direct Salesperson Key code: 3000 + Salesperson#
Caption
In this field you can enter the name of the Salesperson which is used for the display and the printer. The
maximum length depends on the Salesperson File Configuration. When a longer name then allowed is entered
only the programmed length is stored in the file.
Options1
O1.1 Not used.
O1.2 Not used.
O1.3 Not used.
O1.4 Not used.
O1.5 Not used.
O1.6 Not used.
O1.7 Not used.
O1.8 Not used.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Secret Code
The secret code is fixed to 8 hexadecimal digits and must be entered when you want to select this salesperson..
Tender File
File Extension: appname.Q08
Tender# Key code: 700
Direct Tender Key code: 700 + Tender#
Caption
In this field you can enter the name of the tender function which is used for the display and the printer. The
maximum length depends on the Tender File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 If SET then Drawer 1 is opened.
O1.2 If SET then Drawer 2 is opened.
O1.3 Not used.
O1.4 Debet Card Type.
O1.5 If SET then Amount Entry is Compulsory.
O1.6 If SET then Entry is not allowed.
O1.7 If SET EFT Card Function (Note EFT TERMINAL TYPE!!).
O1.8 If SET EFT Cheque Function (Only for France)
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 If SET then OVERTENDERING is NOT ALLOWED and will result in ERROR# 20 (Entry to HIGH).
O2.3 If SET Print Signature Line General Message# 80.
O2.4 If SET Print Endorsement Message# 1 (When 2.4 and 2.5 set Message# 3).
O2.5 If SET Print Endorsement Message# 2 (When 2.4 and 2.5 set Message# 3).
O2.6 Ask for Number Entry.
When SET the register will ask the operator to enter a NUMBER. This number can be alpha-numeric and
the maxiumum size is 32 characters/digits. The register uses GENERAL TEXT #48 (“Number: “) to
prompt the operator and for printing. The operator can enter the number by using the keyboard or a
scanner connected to SCANNER PORT 1 (Parameter 56) or SCANNER PORT 2 (Parameter 57). Instead
of connecting a scanner to port 2 it is also possible to connect another device like a cheque reader or
card reader which send the number terminated by carriage return.
O2.7 Round Amount using Rounding Type Parameter 91.When in the Tender Report configuration the
DISCOUNT and SURCHARGE field are activated the register will report the round up in the discount field
and the round down in the surcharge field and will also print the difference. General Text 66 is used for
ROUND UP and general text 67 is used for ROUN DOWN in the report. You must NOT set SYSTEM
OPTION 275 which is only for the fiscal system.
O2.8 When set then the register will NOT print and display the CHANGE amount incase overtendering is done.
This was requested for an installation were customers could pay with a special meal coupon on which
change was not given. The change amount can still be reported in the OVERTENDER drawer number.
Entry Limitation
When required you can set an entry limitation on a tendering function. See “FILE->ENTRY LIMITATION” for more
details.
Overtender Drawer#
In this field you can program the drawer number in which the change amounts for this tendering function should
be added. This can be used to subtract change on checks from the “cash in drawer” total or to report change as
“tip”.
Drawer File
File Extension: appname.Q09
Drawer# Key code: 800
Direct Drawer Key code: 800 + Drawer#
Caption
In this field you can enter the name of the drawer function which is used for the display and the printer. The
maximum length depends on the Drawer File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 If SET this function is an Open Drawer Function and Opens Drawer 1.
O1.2 If SET this function is an Open Drawer Function and Opens Drawer 2.
O1.3 Not used.
O1.4 Not used.
O1.5 If SET and also OPTION 1.1 or OPTION 1.2 is set then the function can also be used for NUMBER entry.
When no entry is done on the function it will be processed as an OPEN DRAWER function else the entry
will be processed as number entry.
If SET and ALL OTHER OPTIONS are NOT SET it can be used for Alpha Numeric Entry. See SYSTEM
OPTIONS 170 for more details.
O1.6 Don’t include in Cash Declaration
O1.7 No Open Drawer during Transaction.
O1.8 Cash Declaration Function. This function can be used to start cash declaration in R-mode. Also see
SYSTEM OPTION 214.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Options1
O1.1 If SET then Drawer 1 is opened.
O1.2 If SET then Drawer 2 is opened.
O1.3 Not used.
O1.4 Debet Card TYpe.
O1.5 If SET then Received on Account (++) function else Paid Out (--).
O1.7 DEPOSIT
If SET then used as a Deposit function for Balances. Balance is compulsory and drawer is
taken from DRAWER# number. Single Item is not possible.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 If SET Print Signature Line General Message# 80.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 EFT Card Function.
Entry Limitation
When required you can set an entry limitation on a PORA function. See “FILE->ENTRY LIMITATION” for more
details.
Drawer#
In this field you can program the drawer number to which the amounts registered by this PORA function should
be added. The PORA function report will only report the total amount of the function and this can be different from
the drawer total because the drawer total reports what amount should be in the drawer.
Discount File
File Extension: appname.Q11
Discount# Key code: 1000
Direct Discount Key code: 1000 + Discount#
Rate
In this field you enter the fixed percentage rate or amount discount for the discount function. The percentage rate
is always entered with 2 decimals and the theoretical maximum rate you can enter is 42949672.95. In case of a
fixed amount discount the maximum is 4294967295. Note that the decimal point is not entered. For example
when you want a rate of 19.00% you must enter 1900 and when you want an amount of DM 19,00 you also must
enter 1900.
Exempt
In this field you can enter an exempt amount. When the discountable amount (subtotal or item) is below this
amount no discount is allowed and ERROR# 21 “Discount Not Allowed” is given. The theoretical maximum
amount you can enter is 4294967295. Note that the decimal point is not entered. This means the amount is
always enter in the smallest unit. For example DM 1,00 is entered as 100.
Options1
O1.1 If SET then the Discount is an Amount Discount else it is a Percentage Discount.
O1.2 If SET then the Discount is POSITIVE (PLUS) else Negative (DISCOUNT)
O1.3 If SET then FIXED Discount else OPEN or when a RATE is programmed OPEN/FIXED.
O1.4 If SET then ITEM Discount else SUBTOTAL Discount.
O1.5 If SET and ITEM Discount set then also SUBTOTAL Discount when SUBTOTAL depressed!
O1.6 If SET then Print Percentage in front of descriptor.
O1.7 If SET then print Subtotal when Subtotal discount.
O1.8 Not used.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 If SET then update individual items.
O2.6 If SET don’t update TAX itemizers.
O2.7 If SET don’t update SPECIAL Itemizers.
O2.8 Not used.
Entry Limitation
When required you can set an entry limitation on a DISCOUNT function. See “FILE->ENTRY LIMITATION” for
more details. Depending on the function type the limitation is an amount or a percentage limit. Note that when it is
Correction File
File Extension: appname.Q12
Correction# Key code: 1100
Direct Correction Key code: 1100 + Correction#
Caption
In this field you can enter the name of the correction function which is used for the display and the printer. The
maximum length depends on the Correction File Configuration. When a longer name then allowed is entered only
the programmed length is stored in the file.
Options1
O1.1 Function Type.
O1.2 Function Type.
O1.3 Function Type.
O1.4 Function Type.
O1.1, O1.2, O1.3 and O1.4 determine the type of correction function. The following functions are possible:
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Caption
In this field you can enter the name of the foreign currency function which is used for the display and the printer.
The maximum length depends on the Foreign Currency File Configuration. When a longer name then allowed is
entered only the programmed length is stored in the file.
Prefix
In this field you can enter the Prefix which is printed in front of the amount in this currency on the printer (‘s). The
prefix has a maximum length of 3 characters. When you don’t want a prefix be sure the field is empty otherwise
spaces are taken as prefix. Note that the prefix is only used for the printer(‘s) and is never shown on the
display(‘s).
Rate
In this field you enter the conversion rate for the currency. The rate is always entered with 5 decimals and the
theoretical maximum rate you can enter is 42949.67295. Note that the decimal point is not entered. For example
when you want a rate of 1.5 you must enter 150000. The rate is used to calculate the foreign currency and
depending on Option 1-4 the local currency is multiplied or divided by the rate. When you set that the rate is used
to divide it is the value of the foreign currency in local currency. When you set that the rate is used to multiply it is
the value of the local currency in the foreign currency. For example for conversion from LOCAL to EURO the local
currency must be divided by the rate to get the EURO amount and for conversion from EURO to LOCAL the
EURO amount must be multiplied by the rate.
Options1
O1.1 Number of decimals.
O1.2 Number of decimals.
O1.3 Number of decimals.
The number of decimal for the foreign currency is programmed as a combination of O1.1, O1.2 and O1.3.
1 No options SET.
1,0 O1.1 SET.
1,00 O1.2 SET.
1,000 O1.1 & O1.2 SET.
1,0000 O1.3 SET.
1,00000 O1.1 & O1.3 SET.
1,000000 O1.2 & O1.3 SET.
1,0000000 O1.1 & O1.2 & O1.3 SET.
O1.5 If SET the register will give CHANGE in the FOREIGN Currency.
O1.6 If SET the register will give the decimal change (which depends on the decimals in the Foreign Currency)
in LOCAL CURRENCY and the rest in FOREIGN CURRENCY. On the Printer and Display the change
will be shown in Local and Foreign Currency.
Example:
Here is an example of this as if it was being used in Canada (the foreign currency would be U.S. dollars
using a rate of 0.666000). If the total amount due came to $10.00 (Canadian funds), and the customer
want to pay in foreign currency (U.S.) the amount would be $6.66. If they pay with $10.00 (U.S.) the
change would be given as follows:
These amounts are calculated from the base that when the customer pays with the $10.00 (U.S.) the
complete change in U.S. would be $3.34. The $3.00 is a whole number and will be given as $3.00 U.S.
The $0.34 will be converted into Canadian funds and taken out of the local currency drawer total.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Drawer#
In this field you can program the drawer number to which the amounts registered by this PORA function should
be added. The PORA function report will only report the total amount of the function and this can be different from
the drawer total because the drawer total reports what amount should be in the drawer.
Caption
In this field you can enter the name of the User Report which is used for the display and the printer. The
maximum length depends on the User Report File Configuration. When a longer name then allowed is entered
only the programmed length is stored in the file.
Options1
O1.1 If SET then Drawer 1 is opened when the report is finished successfully.
O1.2 If SET then Drawer 2 is opened when the report is finished successfully.
O1.3 Not used.
- 54 - QProg Rel 1.69
O1.4 Not used.
O1.5 If SET then this is a CLERK REPORT and only CLERK totals are printed.
Note that all links which are not clerk are NOT printed.
O1.6 If SET then this is a SALESPERSON REPORT and only SALESPERSON totals are printed.
Note that all links which are not salesperson are NOT printed.
O1.7 If SET then the REPORT is an ALL CLERK or ALL SALESPERSON REPORT.
Note that Option O1.5 or O1.6 must also be set!
Options2
O2.1 Suppress X-Counter.
O2.2 Suppress Z-Counter.
O2.3 Reset Receipt# and Training Receipt# in Z-mode
O2.4 Requires Cash Declaration.
O2.5 Not used.
O2.6 Not used.
O2.7 Report is NOT allowed in X-Mode.
O2.8 Report is NOT allowed in Z-Mode.
List
When you click on this column a special menu will be shown on the right side of the screen in which you can enter
for each entry in the linked report list the options, period, file type, start record, end record, pointer type, pointer
start and pointer end. The start and end fields are shown depending on the file type and pointer type.
NOTE:
When you select a period, file type or pointer type which are not activated in the configuration they will
automatically skipped from the report.
Active Link#
In this list box you select the link you are programming. The maximum number of links depends on the User
Report File Configuration.
Options
O1 Print “Soft” Total.
O2 Don’t Reset LINK in Z-Mode.
O3 When Set Start/End is Department Range.
O4 No ZERO Skip (Print All Totals).
O5 When SET the register will do a percentage comparison on the totals in the link. It will first calculate the
total of all totals in the link which can take some time when you activate this feature in a large PLU or
NETWORK REPORT because the register has to process the report link two times!! It will calculate the
percentage of each total compared to the link total and print it on the last line with GENERAL TEXT# 60.
NOTE that this calculation is ONLY done on the REGISTER and NOT when the report is taken by
COMPUTER.
O6 Not used.
O7 Not used.
O8 Not used.
Period#
In this list box you select the period which should be processed in this report link. There are 4 periods possible.
Note that the period you select for a file MUST be active in the file report construction else nothing will appear on
the report.
Pointer Type
In this list box you select the pointer type which should be processed in this report link. There are 7 pointer types
available. Note that the pointer type you select for a file MUST be active in the file report construction else nothing
will appear on the report.
Caption
In this field you can enter the name of the balance function which is used for the display and the printer. The
maximum length depends on the Balance File Configuration. When a longer name then allowed is entered only
the programmed length is stored in the file.
Options1
O1.1 Function Type.
O1.2 Function Type.
O1.3 Function Type.
O1.4 Function Type.
O1.1, O1.2, O1.3 and O1.4 determine the type of balance function. To which type of Balance the function applies
is determined by O1.5 and O1.6. The following functions are possible:
NOTE:
When a BILL type is selected and not printed yet it can be cancelled by pressing the CLEAR key.
PRINT OR SELECT BALANCE BILL (1, 2 are SET and 3,4 are NOT SET)
This is a combination of the SELECT and PRINT BALANCE BILL function.
OPEN AUTOMATIC BALANCE (2, 3 are SET and 1, 4 are NOT SET)
This is a special function for the DRY-CLEANING system. When the key is pressed at the end of the
transaction the register will automatically store the transaction on the first free balance number. When the
balance number is entered on this key at the start of the transaction the register will open the balance
when the balance is used and after opened the balance can be paid or closed.
NOTE:
When Free Assignment of Balance Numbers is used this function will give ERROR# 6 (Invalid
Function).
COVERS (1, 2, 3 are SET and 4 is NOT SET)
This function can be used to enter the number of covers or guests for a balance or direct sale. Also check
SYSTEM OPTION 159.
DIRECT BALANCE SALE (2, 4 are SET and 1, 3 are NOT SET)
SPECIAL BALANCE FUNCTION type for DIRECT SALE. The options and print options work the same as
for a normal open balance function and it is advised to use the same settings except for the print options.
When a balance is opened with this function it can only be closed by a TENDER function so it acts like a
direct sale but it can be used to re-call balance information like Balance Text, Price Level and Discount for
a customer which are then printed and activated for this one customer. When you activate PERIOD 2 in
the balance configuration you can also keep track of the total sales done by this customer. There is no
need to acivate the storing of articles because when the transaction is started with this type of function
they are never stored.
TRANSFER ONLY (3 and 4 are SET and 1 and 2 are NOT SET)
BALANCE function for transferring a balance to another balance which will check if the new balance is
open. When you try to transfer to an open balance ERROR# 38 (Balance Used) is given.
O1.7 If SET then display the current balance items in on the screen (only multiline!!) when opened. The items
are always stored in the Transaction Buffer so it is always possible to scroll back using the ARROW or
PAGE keys.
O1.8 If SET then automatically close the previous balance when a new number is entered. Only valid for
OPEN/ADD/CLOSE function type!!
NOTE: When AUTOFINALIZING is activated in Program Options you MUST be sure that FUNCTION 1 is
programmed as a CLOSE TABLE function. When you are also using ROOMS and/or ACCOUNTS you must
program FUNCTION 2 as CLOSE ROOM and FUNCTION 3 as CLOSE ACCOUNT also when your are NOT
using AUTOFINALIZING!
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
Code#
In this field you can enter the random code which is used to open this Table. The size of the code depends on the
Table File Configuration. Note that this file is searched sequentially and must be the same in all registers when
floating balances in a network are used.
Limit
In this field you enter limit for this table when the limit is reached you are not allowed to store more items on this
table.
Price Level
When activated you can program a level for each balance. When the level is set to ZERO it is not activated and
the normal level is used. The level is used a a base level and disables the level selected by the clock or a level
which is manually selected. Note that the shift on shift level still works in the same way as when the base level is
selected by the clock.
Discount
It is possible to assign an automatic Discount to a Balance. You must program the discount function# which
should be used the discount (rate or amount depends on function) and the exempt amount. The discount is given
and reported when the balance is paid. When the balance is below the exempt amount the discount is not given.
When Subtotal is pressed the register will display the subtotal including the discount.
Rate
It is possible to assign a rate or amount for the discount. See discount for more info.
Exempt
It is possible to assign an exempt amount for the discount. See discount for more info.
Time Link
When both the TIME LINK and TIME UNIT field are set the register takes the TIME LINK field as PLU number for
calculation. When the TIME UNIT field is set to ZERO the system will use the TIME LINK value as the MENU
number for calculation. In this way you can use different rates for different time periods as with the parking
system (see SYSTEM PARAMETER 138). By selecting another PRICE level before the TIME OUT key is
pressed you can have different rates for a balance. You can print the level text with the article by setting OPTION
1-2 in the PRICE LEVEL function to indicate the different rate.When both the TIME LINK and TIME UNIT field are
set to ZERO the TIME system is not active for this balance.
Salesperson
Automatic Salesperson selection when opening a balance. When the balance is opened the programmed
Salesperson is selected. When a value of ZERO is programmed the active salesperson is not changed. Don't
forget to set OPTION 19 (Reset Salesperson to 1) so the Salesperson 1 is automatically selected when the
balance is closed. This function can be used if you need detailed reporting on a balance or range of balances.
Code#
In this field you can enter the random code which is used to open this Room. The size of the code depends on the
Table File Configuration. Note that the file is searched sequentially and must be the same in all registers when
floating balances in a network are used.
Limit
In this field you enter limit for this room when the limit is reached you are not allowed to store more items on this
table.
Price Level
When activated you can program a level for each balance. When the level is set to ZERO it is not activated and
the normal level is used. The level is used a a base level and disables the level selected by the clock or a level
which is manually selected. Note that the shift on shift level still works in the same way as when the base level is
selected by the clock.
Discount
It is possible to assign a automatic Discount to a Balance. You must program the discount function# which should
be used the discount (rate or amount depends on function) and the exempt amount. The discount is given and
reported when the balance is paid. When the balance is below the exempt amount the discount is not given.
When Subtotal is pressed the register will display the subtotal including the discount.
Rate
It is possible to assign a rate or amount for the discount. See discount for more info.
Exempt
It is possible to assign an exempt amount for the discount. See discount for more info.
Time Link
Time Unit
In the TIME UNIT field the number of minutes for 1 period is programmed. The register will use this to calculate
the time units used. When both the TIME LINK and TIME UNIT field are set to ZERO the TIME system is not
active for this balance.
Salesperson
Automatic Salesperson selection when opening a balance. When the balance is opened the programmed
Salesperson is selected. When a value of ZERO is programmed the active salesperson is not changed. Don't
forget to set OPTION 19 (Reset Salesperson to 1) so the Salesperson 1 is automatically selected when the
balance is closed. This function can be used if you need detailed reporting on a balance or range of balances.
Code#
In this field you can enter the random code which is used to open this Account. The size of the code depends on
the Account File Configuration. Note that the file is searched sequentially and must be the same in all registers
when floating balances in a network are used.
Limit
In this field you enter limit for this account when the limit is reached you are not allowed to store more items on
this table.
Price Level
When activated you can program a level for each balance. When the level is set to ZERO it is not activated and
the normal level is used. The level is used a a base level and disables the level selected by the clock or a level
which is manually selected. Note that the shift on shift level still works in the same way as when the base level is
selected by the clock.
Store Discount
It is possible to assign a automatic Discount to a Balance. You must program the discount function# which should
be used the discount (rate or amount depends on function) and the exempt amount. The discount is given and
reported when the balance is paid. When the balance is below the exempt amount the discount is not given.
When Subtotal is pressed the register will display the subtotal including the discount.
Exempt
It is possible to assign an exempt amount for the discount. See discount for more info.
Time Link
When both the TIME LINK and TIME UNIT field are set the register takes the TIME LINK field as PLU number for
calculation. When the TIME UNIT field is set to ZERO the system will use the TIME LINK value as the MENU
number for calculation. In this way you can use different rates for different time periods as with the parking
system (see SYSTEM PARAMETER 138). By selecting another PRICE level before the TIME OUT key is
pressed you can have different rates for a balance. You can print the level text with the article by setting OPTION
1-2 in the PRICE LEVEL function to indicate the different rate.When both the TIME LINK and TIME UNIT field are
set to ZERO the TIME system is not active for this balance.
Time Unit
In the TIME UNIT field the number of minutes for 1 period is programmed. The register will use this to calculate
the time units used. When both the TIME LINK and TIME UNIT field are set to ZERO the TIME system is not
active for this balance.
Salesperson
Automatic Salesperson selection when opening a balance. When the balance is opened the programmed
Salesperson is selected. When a value of ZERO is programmed the active salesperson is not changed. Don't
forget to set OPTION 19 (Reset Salesperson to 1) so the Salesperson 1 is automatically selected when the
balance is closed. This function can be used if you need detailed reporting on a balance or range of balances.
File Description
The Balance Item Blocks file is used to store Item Blocks which can hold 10 items each. The item blocks contain
detailed item information for the Table, Room and or Account totals if activated. The contents of this file is
changed during registration.
Modifier File
File Extension: appname.Q20
Modifier# Key code: 4000
Direct Modifier Key code: 4000 + Modifier#
Options1
O1.1 Modifier Text is PLU#
O1.2 Use as Direct PLU.
When OPTION1-1 and 1-2 are BOTH set you can use this modifier to put a scancode on the keyboard.
When this modifier is used the register will use the number programmed in the text field as article
number. This function can be used to put PLU SCANCODES on the keyboard so it is no longer required
to re-program the keyboard when plu’s are created and/or deleted. Note that when you set OPTION1-2
this modifier CANNOT be used a a normal modifier anymore but is always processed as an ARTICLE.
O1.3 Variable Text Function.
When SET you must enter a text on this modifier. When you press the function without entry it will show
the programmed function name on the display and will switch to the ALPHA KEYBOARD until the
CLEAR key or the FUNCTION (or ENTER on soft keyboard) is pressed again. You can also do a direct
entry but then only digits can be entered unless you are using an external keyboard (on Concerto only).
The function text is also displayed and printed. The maximum length is 32 characters and the text stays
with the article. Note that modifier keys cannot be used as alpha keys.
O1.4 KP re-routing.
When SET all articles which are entered after this function is selected are printed on the KP as specified
in this function (option 1-5 to 1-8 and 2-5 to 2-8) until another re-routing is selected or the transaction is
closed. It is possible to combine this option with option 1-3.
O1.5 KP-1
O1.6 KP-2
O1.7 KP-3
O1.8 KP-4
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 MODIFIER FOR COURSE INFO. When SET this modifier can be used to print course information on the
KP ticket. When OPTION 2-4 is set the register will print the programmed text using the font as
programmed in PARAMETER 69 (Kitchen Printer Name Font) and an empty line between the previous
entered items and the items entered after this function. This can be used to indicate for example starters,
main course etc. When OPTION 1-4 is also set the register will issue the ticket and print the text in the
ticket header instead of printing and empty line and the text. OPTION 2-4 can be combined with OPTION
1-3 (Free text).
O2.5 KP-5
O2.6 KP-6
O2.7 KP-7
O2.8 KP-8
File Description
The Electronic Journal file contains a record for each line of information. The data is stored as ASCII print data or
as binary data depending on the Electronic Journal Configuration. The electronic journal can be printed/reset by
QProg Rel 1.69 - 63-
Printed on 7-12-21
User Report 101 or only reset by User Report 102. From release 050415 it is also possible to take report 104 in
X-mode which will only print the tickets of the active clerk. It is possible to print the journal in 3 ways:
2 – Enter YY on the Multiply key (X) an then 101 on the report key.
Now the last YY tickets are printed.
3 – Enter 0 on the Multiply key (X) and then 101 on the report key.
Now the complete journal is printed. When this is done in Z position the Electronic Journal is cleared.
Data Format
TEXT
The data in the Electronic Journal is stored as ASCII print data which is like a copy of a printed journal.
BINARY)
The data in the Electronic Journal is stored as binary data which is like a copy of the transaction buffer.
Message Text
In this field you can enter the text of the endorsement message. The number of lines can be changed by the text
lines list box and depends on the Endorsement Message File Configuration. When a longer name then allowed is
entered only the programmed length is stored in the file. On the most right side of each line you can select the
FONT (1-8) for this line. See “FILE -> PRINT OPTIONS” for more details on the available fonts. At the moment
only Message #1 and #2 are used to print a special text on a Balance Invoice.
Number
With this list box you can select which endorsement message you are editing.
Text Line
With this list box you can select how many text lines are active for this endorsement message.
File Description
In this file the individual keyboards are stored when more the one keyboard is active in the application. The
keyboards are programmed in the KEYBOARD menu.
Caption
In this field you can enter the name of the macro which is used for the display and the printer. The maximum
length depends on the Macro File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 No Entry Allowed.
O1.2 Use Keycodes instead of Keynumbers.
O1.3 Accept Entry on FIRST Function (1.3 & 1.4 SET use THIRD Function).
O1.4 Accept Entry on Second Function (1.3 & 1.4 SET use THIRD Function).
O1.5 No Entry Reset. When set the entry made in the macro is not cleared when the macro is finished.
O1.6 Not used.
O1.7 Not used.
O1.8 Not used.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
List
When you click on this column a table will be shown on the right side of the screen in which you can enter the key
numbers or keycodes when OPTION 1-1 is set. The maximum number of keys in the macro depends on the
Macro File Configuration and OPTION 1-1. When OPTION1-1 is NOT SET the maximum number of keys is as
programmed in the configuration. When OPTION 1-1 is SET the maximum number of keycodes is the maximum
number of keys divided by 2 because a keycode requires 2 bytes and a keynumber only 1 byte.
It is also possible to include Central Lock and Clerk Lock positions in the a macro the original lock is restored
when macro is finished. The following codes are available for lock selection in a macro:
CLERK LOCK
OFF = 230
KEY 1 to 15 = 231 to 245
CENTRAL LOCK
OFF (L) = 250
RG (R) = 251
X (X) = 252
Z (Z) = 253
MG (P) = 254
PRG (T) = 255
When using keycodes the following keycodes are used for programming and reporting:
QProg Rel 1.69 - 65-
Printed on 7-12-21
TIME = 8 Time Key
DATE = 9 Date Key
URPT = 13 User Report also ENTER key
SRPT = 14 System Report
P_TYPE = 19 Program Type
P_DUMP = 20 Program Dump
For numeric or alfanumeric keys you must program the ASCII code as keycode!
Menu File
File Extension: appname.Q25
Menu# Key code: 600
Direct Menu Key code: 600 + Menu#
Caption
In this field you can enter the name of the menu which is used for the display and the printer. The maximum
length depends on the Menu File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 O1.1 and O1.2 are used to specify the number of decimals in the Quantity field of the arrangement list.
Note that this applies to ALL quantities in the list.
O1.1, one decimal so 5 is processed as 0.5.
O1.2, two decimals so 5 is processed as 0.05.
O1.1 & O1.2, three decimals so 5 is processed as 0.005.
O1.2 see above.
O1.3 Calculate Price. When set the register will calculate the price of the arrangement by adding up all the PLU
in the list. It will use the active price level Not used.
O1.4 Items on Ticket. When set the register will print the arrangement name and the PLU’s of the arrangement
on the receipt, journal and slip without the price. When not set only the arrangement name and price are
printed.
O1.5 Items on KP. When set the register will print the arrangement name and the PLU’s of the arrangement on
the Kitchen Printers as selected by the PLU in the LIST. When not set only the arrangement name is
printed.
O1.6 No Price Entry. When set it is not allowed to override the programmed price by a NEW PRICE entry.
O1.7 Report Price Difference. When set then the difference between the calculated price and the entered price
is reported in the last PLU of the menu. When the entered price is less then the calculated price the sale
will not be allowed.
O1.8 Not used.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 One Quantity Ticket on Kitchen Printer.
O2.3 Double Tickets on Kitchen Printer.
O2.4 If set it is not allowed to enter a quantity with decimal point.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Caption
In this field you can enter the name of the Price Level which is used for the display and the printer. The maximum
length depends on the Price Level File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 If SET then also SHIFT the TAX1 and TAX3. This means that 1 shifts to 2, 3 shifts to 4. Note that only
the activated tax selections are shifted!
O1.2 Print Level Text with ITEM.
O1.3 Shift On BASE Level (Shift within Shift!).
O1.4 Use 0.5 as Report Quantity.
O1.5 Use 2.0 as Report Quantity.
O1.6 Not used.
O1.7 Not used.
O1.8 If SET this level OVERRIDES the LEVEL selected by the CLOCK.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Caption
In this field you can enter the name of the transaction type which is used for the display and the printer. The
maximum length depends on the Transaction Type File Configuration. When a longer name then allowed is
entered only the programmed length is stored in the file.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Tax
When you want to change the tax status of items when this transaction type is selected you can specify here.
Level
When you want to change the active price level when this transaction type is selected you can specify here.
Caption
In this field you can enter the name of the special itemizer function which is used for the display and the printer.
The maximum length depends on the Special Itemizer File Configuration. When a longer name then allowed is
entered only the programmed length is stored in the file.
Rate
When Option 1-1 is SET it is possible to use the Special Itemizer for special charges or discounts and in this case
you can enter the percentage rate in this field. The rate is always entered with 4 decimals and the theoretical
maximum rate you can enter is 429496.7295. Note that the decimal point is not entered. For example when you
want a rate of 19.00% you must enter 1900.
Exempt
When Option 1-1 is SET it is possible to use the Special Itemizer for special charges or discounts and in this case
you can enter an exempt amount in this field. When the special itemizer is below this amount no tax is calculated.
The theoretical maximum amount you can enter is 4294967295. Note that the decimal point is not entered. This
means the amount is always enter in the smallest unit. For example DM 1,00 is entered as 100.
Options1
O1.1 SPECIAL ITEMIZER TYPE
- 68 - QProg Rel 1.69
SET
This Special Itemizer is used for special charges or discounts. O1.2 determines whether it is a charge or
a discount. This type of Special Itemizer is printed and displayed before the transaction total and is
added/subtracted to the sale amount.
NOT SET
This Special Itemizer is only used for accumulating sales and can be used by another function for special
processing. This type of Special Itemizer is printed at the bottom of the receipt before the VAT information
and is not displayed.
O1.3 If SET then Print Percentage in front of descriptor when used as special discount/charge.
O1.4 If SET then also print when amount is zero.
O1.5 If SET then this Itemizer is used for commission calculation.
The register will use the programmed rate and exempt amount of this special itemizer to calculate the
commission when the report of this special itemizer is taken. You can suppress printing of the Itemizer on
the receipts by resetting all print options.
O1.6 Not used.
O1.7 Not used.
O1.8 Not used.
Options2
O2.1 Not used.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
Caption
In this field you can enter the name of the window lookup which is used for the display and the printer. The
maximum length depends on the Window Lookup File Configuration. When a longer name then allowed is entered
only the programmed length is stored in the file.
Options1
O1.1 Not used.
O1.2 Not used.
O1.3 Not used.
O1.4 Not used.
O1.5 Not used.
O1.6 Not used.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
O2.8 Not used.
List
When you click on this column a table will be shown on the right side of the screen in which you can enter the key
codes of the functions you want to display when this WLU is activated.
Caption
In this field you can enter the name of the condiment table which is used for the display and the printer. The
maximum length depends on the Condiment Table File Configuration. When a longer name then allowed is
entered only the programmed length is stored in the file.
Options1
O1.1 Compulsory Selection
O1.2 Fixed Quantity. When set this condiment table can be used to force a fixed quantity selection of modifiers.
When you want to force a fixed selection of modifiers for the kitchen( and reports). For example when an
article consists of 5 different modifiers and you want to force the operator to select 5 modifiers from the
active condiment table before he can continue. When set the last field in the (modifier) list is the required
quantity. For example a condiment the table with OPTION 1-1 and OPTION 1-2 set and has a
programmed list: 4001, 4002, 4003, 5 will force the operator to select 5 condiments from the list before he
can continue.
O1.3 When set and OPTION 1-1 and 1-2 are NOT set the condiment table is automatically re-displayed (stay
down) when a selection is made. You can abort by pressing the CLEAR key.
O1.4 Not used.
O1.5 Not used.
O1.6 Not used.
O1.7 Not used.
O1.8 Not used.
Options2
O2.1 If SET then only allowed by Manager Key or Clerk.
O2.2 Not used.
O2.3 Not used.
O2.4 Not used.
O2.5 Not used.
O2.6 Not used.
O2.7 Not used.
- 70 - QProg Rel 1.69
O2.8 Not used.
List
When you click on this column a table will be shown on the right side of the screen in which you can enter the key
codes of the functions you want to display when this condiment table is activated. Note that in the Condiment
Table you must program the KEYCODE of the condiment you want to display. At the moment only MODIFIERS
(key code 4XXX) are supported!!
Caption
In this field you can enter the name of the action table which is used for the display and the printer. The maximum
length depends on the Action Table File Configuration. When a longer name then allowed is entered only the
programmed length is stored in the file.
Options1
O1.1 Match is Amount instead of Quantity.
O1.2 One Match Only.
O1.3 %- Discount when Match.
O1.4 Discount on Total Table Amount.
O1.5 Average Price as Discount.
O1.6 Set Price (Meal Deal).
When set in an ACTION table and the ACTION is using a SET LIST (option 1-8 or 2-2 set) the register
will calculate the DISCOUNT by subtracting the PROGRAMMED SET PRICE from the ORIGINAL
PRICE.
O1.7 If set then Check Item List else only Table# (list must be active).
O1.8 If set then Check Item List for Exact Set Match (list must be active).
Options2
O2.1 Update Individual Articles.
When set in an ACTION table and the ACTION is using an ITEM LIST (option 1-7 or 1-8 set) the register
will update the discount in the articles used. When OPTION 1-7 is set it will divide the discount (according
to ratio) over the items used. When OPTION 1-8 (SET MATCH) is set it will divide the discount
(according to ratio) over the ITEMS in the SET MATCH.
O2.2 Department List (Meal Deal).
When set in an ACTION table the LIST contains DEPARTMENT numbers instead of PLU number.
O2.3 Fixed Price. When set this price is used for all articles after the match.
O2.4 Chained Table. When set the last number in the list is the next action table which is checked. Note that
when you chain the action tables the next table must contain the articles/departments of the previous one
as in the example.
example:
Meal Deal 1. (Trigger value 3) Price 2.75
1 x Drink
1 x Sandwich
1 x Crisps
Match
When OPTION 1-1 is SET this field contains the match amount else it contains the match quantity. When set in
combination with OPTION 1-8 the set list contains amounts instead of quantities for each item in the list (See also
MULTIBUY.DOC).
Discount
When OPTION 1-3 is SET this field contains the discount percentage else it contains the discount amount. Note
that the percentage has 2 decimals, 10.00% is programmed as 1000 (See also MULTIBUY.DOC).
Maximum Discount
When this field is NON ZERO this is the maximum discount amount allowed. When the calculated discount is
larger this amount will be taken as the discount (See also MULTIBUY.DOC).
List
When in the configuration the Item List is activated this column contains the number of items in the List.
- When OPTION 1-7 is set the list contains PLU numbers.
- When OPTION 1-8 is set the list contains PLU numbers and Quantity Match
- When OPTION 1-1 and 1-8 are set the list contains PLU numbers and Amount Match.
Invoice File
File Extension: not available
Function Key code: not available
Direct Key code: not available
File Description
The Clerk Interrupt file is used to temporarily store a transaction for a clerk. In this way more then one clerk can
work simultaneously on the cash register. When a clerk starts a transaction a buffer in this file will be assigned to
the clerk in which the transaction is stored so it can be recalled when another clerk interrupts the transaction.
When the transaction of a clerk is larger then the maximum number of lines it will be not possible to interrupt this
transaction and the clerk must finalize it first.
System
System Parameters
System Parameters.
W Word size
0 8 data, no parity, 1 stop
1 8 data, no parity, 2 stop
2 8 data, even parity, 1 stop
3 8 data, even parity, 2 stop
4 8 data, odd parity, 1 stop
5 8 data, odd parity, 2 stop
6 7 data, no parity, 1 stop
7 7 data, no parity, 2 stop
8 7 data, even parity, 1 stop
9 7 data, even parity, 2 stop
10 7 data, odd parity, 1 stop
11 7 data, odd parity, 2 stop
B Baud rate
0 1200
- 74 - QProg Rel 1.69
1 2400
2 4800
3 9600
4 19200
5 38400
6 57600 (52083 when port 3,4,5 or 6 )
7 115200 (78125 when port 3,4,5 or 6 )
NOTE:
When the baud rate and word size for the computer communication is changed it will be active after
ending of the communication session (installing or updating).
When OPTION 6 “AUTOFINALIZING” is set and the timer expires when the register is in transaction and no
CLERK LOCK is inserted the transaction is automatically closed.
Note that you can force IDLE mode by pressing the X key without entry when the register is NOT in transaction.
This can be used to de-select a clerk when CLERK is COMPULSORY.
NOTE:
When using an external printer the printer must be set to 8 data, no parity, 1 stop bit and must use Hardware
Handshaking (DTR/DSR or RTS/CTS). The baud rate can be variable but 9600 or 19200 is advised. The cable
used must support all signals (TXD, RXD, CTS, RTS, DTR, DSR, GND).
TYPE OF PRINTER (Parameter: 021, 025, 029, 033, 037, 041, 045, 049)
The type of printer. See Receipt Printer types for the available type numbers. When the type is set to ZERO it
means there is no Kitchen Printer used.
PORT NUMBER (Parameter: 022, 026, 030, 034, 038, 042, 046, 050)
The port number to which the printer is connected. Port 0 means internal printer.
FONT (Parameter: 023, 027, 031, 035, 039, 043, 047, 051)
The font (0 – 7) used for the articles on this kitchen printer. The font of the other lines is
programmed generally in System Parameters 68 until 72.
BACKUP KP# (Parameter: 024, 028, 032, 036, 040, 044, 048, 052)
The kitchen printer number (0 – 8) for the back up printer. Value 0 means there is no backup.
0 = 1
1 = 1,0
2 = 1,00
3 = 1,000
4 = 1,0000
5 = 1,00000
6 = 1,000000
EAN-13: “FFNNNNNNNNNNC”
EAN-8: “2NNNNNNC”
The in store code can contain 3 fields. Field 1 contains the Item Code, field 2 is an optional Price Check Digit field
(when the code contains the price) and field 3 contains either the quantity or price.
The contents of the in store field is specified as a 3 digits number “XYZ”.
- 78 - QProg Rel 1.69
X = 0 -> The Article code is used a PLU number. The ID is included in the PLU number!
X = 1 -> The Article code is used a PLU number. The ID is NOT included in the PLU number!
X = 2 -> The In store Marking ID is used as department number (only valid when used with Price Code)!
Y = 9 -> Code is interpreted as price code with Price Check Digit and the stored price is multiplied depending on
the prefix code. See Y= 8 for values
NOTES:
- When using the format which converts the price automatically using Foreign Currency # 1 it is
NOT POSSIBLE to use the ID as department number because the maximum value you
can program is 256!
- When you have set the option for converting and Foreign Currencies are not active in the
program ERROR# 4 (INVALID ARTICLE) is given!!
- Foreign Currency Function #1 must be programmed for converting the LOCAL currency to the currency
stored in the barcode.
Example 1:
Suppose we want to use codes starting with 20 as a 4 digit price code with Price Check Digit and the Item
code as a PLU number we must specify FLAG 78 as “054” the Item code will be automatically 5 digits.
The code “2012345P0250C” (p = price check digit, c is check digit) will result in a sale of 250 on PLU
2012345.
Example 2:
Suppose we want to use codes starting with 21 as a 5 digit price code without Price Check Digit and the
Item code as a department number we must specify FLAG 79 as “245”.
The code “211234502500C” (c is check digit) will result in a sale of 2500 on department 21.
Example 3:
NOTE:
The maximum value which can be programmed is 255 so when using the ID as department# the
maximum price length with check digit will be 5 !!
When programming a value of “000” for the format the codes are interpreted as normal barcodes.
When programming a value of “100” for the format the codes are not interpreted and always result in
ERROR#4 (Invalid Article) this can be useful when automatic creation of PLU is used.
Also check OPTION# 81 for automatic registering on department# 1
X = 0 -> The Article code is used a PLU number. The Prefix is included in the PLU number!
X = 1 -> The Article code is used a PLU number. The Prefix is NOT included in the PLU number!
X = 2 -> The Article code is not used and only the Prefix is used as PLU number.
Example:
Suppose we want to use German Press Codes and include the prefix in the article code we must specify
FLAG 88 as “001”.
- 80 - QProg Rel 1.69
The code “434123450250C” (c is check digit) will result in a sale of 250 on PLU 43412345
NOTE:
Also check OPTION# 82 for automatic registering on department# 2 and OPTION#83 for automatic
EURO price conversion.
TYPE = 11, CKD Concert for France. See EFT_FRA.DOC for more information.
TYPE = 12, INGENICO with the EURO Protocol. See EFT_FRA.DOC for more information.
TYPE = 21, BANK AXEPT for Norway. See EFT_NOR.DOC for more information.
TYPE = 31, POINT S3000 for Finland. See EFT_FIN.DOC for more information.
TYPE = 32, POINT S3000 for Finland with Signature. See EFT_FIN.DOC for more information.
TYPE = 41, NETS for Singapore. See EFT_SGP.DOC for more information.
TYPE = 81 Point Xenta terminal for Sweden. See EFT_SWE.DOC for more information.
- The mode is started by entering 9999 on the SUBTOTAL key when in Registration Mode or on the TYPE key
when in programming mode.
- The register will display the current value of Parameter 100 on the operator display and fill the remaining with
test strings.
- To increase the contrast press the LINE UP or PAGE UP key and to decrease the contrast press the LINE
DOWN or PAGE DOWN key.
- The register will adjust the contrast by one step at a time. Note that after reaching the minimum or maximum
value the contrast is set back to the default value. The minimum value for the 16 line display is 10 and the
maximum is 28. The default value is 20.
- When finished changing the contrast press the CLEAR key or turn the Central Lock.
VALIDATION FORMAT:
12345678901234567890123456789012345
LINE1: 27-11-2002 17:11:00 CLERK 1 L0101
LINE2: #999999 PLU 1 9,999,999,999,99
(Line1: Date, Time, Clerk Name, Location#+Register#)
(Line2: Receipt#, Function Name, Amount)
Example1:
When you program a value of 1 the register will process all codes starting with 90 on Balance Function# 1 which
is normally programmed as the TABLE function. Code 900010 will select Table 10.
Example2:
When you program a value of 93 the register will process all codes starting with 99 on Balance Function# 3 which
is normally programmed as the ACCOUNT function. Code 9900123 will select Account 123.
1) When you open a table by only entering the TABLE# it will ALWAYS select SEAT# 1 by default. The display
will show “Table# X.1” where X is the TABLE#.
2) On the Kitchen Printer is will also print “TABLE# X.1” so you can see to which seat the entry belongs.
3) You can change SEAT# by entering the SEAT# on the SEAT# key (key code 280). When you change the
SEAT# the register will close the current SEAT and sent the information to the kitchen.
4) It is possible to open a SEAT directly by entering the table number with a decimal point followed by the seat
number. When you enter 2.3 it will open seat# 3 on table# 2.
5) When an INVOICE is selected the register will prompt you for the type of INVOICE.
5a) All Combined (GENERAL TEXT# 62).
When selected the register will transfer all seats to a temporary table with number 1.0 and print the combined
invoice.
5b) All Separate (GENERAL TEXT# 63).
When selected the register will print the Invoice for all seats used for this TABLE.
5c) Single/Group (GENERAL TEXT# 64).
When selected the register will print the Invoice for the current seat when closed directly with CASH or
ORDERED. It is possible to select a number of seats by entering the seat number on the SEAT# key before
CASH or ORDERED is pressed. Note that a seat number can be corrected with the E.C. (Error Correction) key.
6) You can transfer a SEAT to another SEAT by using the TRANSFER key and then enter the new SEAT# on the
SEAT# key.
7) You can transfer a SEAT to another TABLE-SEAT by using the TRANSFER key and then enter the new
TABLE-SEAT using decimal entry on the TABLE# key. For example 2.3 will transfer to table# 2 seat# 3.
8) The register handles each seat as a separate balance. The only difference is that you can switch seats easily
by using the SEAT# key and that you can combine at payment.
9) It is advised to set SYSTEM OPTION 220 so the receipt number is not incremented when no sales are made
to the current balance because there is no ticket issued.
10) New FIXED FUNCTION SEAT# with key code 280.
11) NEW GENERAL TEXTS 61 used for “SEAT#”, 62 used for “ALL COMBINED”, 63 used for “ALL SEPARATE”
and 64 used for “SINGLE/GROUP”.
USING SEATS WITH FIXED TABLES. When in the configuration of the TABLE TOTALS the CODE SIZE is set
to ZERO the register will automatically divide the number of tables by the number of seats as programmed plus 1.
Parameter 111 is used to fix the layout of the TABLE TOTAL file and an extra balance for each table is required
USING SEATS WITH FREE NUMBER ASSIGMENT. When in the configuration of the TABLE TOTALS the
CODE SIZE is NON ZERO and also the OPTION FREE NUMBER ASSIGNMENT is SET the register will
automatically assign a table total to a TABLE-SEAT number when first opened. You only must take care that the
code size is large enough to hold the TABLE-SEAT number. When you are using less then 10 seats the last digit
is used for the seat number when you are using more the last 2 digits are used for the seat number. Parameter
111 is only used to set the maximum seat# you can enter. For example when the code size is set to 4 and the
number of seats to 8 the maximum TABLE-SEAT number can be 999.8. Because assignment is automatically the
number of TABLE TOTALS only refers to the maximum number of TABLE-SEAT balances open at the SAME
time so in the above example and the number of TABLE TOTALS is set to 50 you can open any number between
1.1 and 999.8.
USING SEATS WITH PREPROGRAMMED NUMBERS. When in the configuration of the TABLE TOTALS the
CODE SIZE is NON ZERO and also the OPTION FREE NUMBER ASSIGNMENT is NOT SET you need to
program the TABLE-SEAT numbers in the TABLE file. In this way you can program the number of seats for each
table because when the combination is not present you cannot book on this TABLE-SEAT combination. You
MUST also program the BASE TABLE# because it is needed as temporary storage when a combined invoice is
issued. For example you have TABLE# 1 with 2 seats, TABLE# 2 with 3 seats and TABLE# 3 with 4 seats and
parameter 111 set to 8 you must program the TABLE file as follows: 10, 11, 12, 20, 21, 22, 23, 30, 31, 32, 33 and
34. When you have set parameter 111 to 16 you must program the TABLE file as follows: 100, 101, 102, 200,
201, 202, 203, 300, 301, 302, 303 and 304.
- The first time the register will automatically divide the tables over the number of activated table maps.
- It is possible to reset the table plan by entering 201 on the program TYPE key. Note the register will divide the
available tables over the number of table maps.
- You can change the position, remove a table or create a new table in a special programming mode which can be
activated by entering 200 on the program TYPE key or in MANAGER mode by entering 200 on the SUBTOTAL
key. The register will show the table map and an extra field on the reight bottom which is used as a table pool.
When you select a table and keep it selected you can drag it to this field and after you release it will be removed.
When you press on the table pool a new table will be created and after you dragged it to the desired position it will
ask for the table number. You must enter the table number on the displayed numeric keyboard and then press the
‘=’ key.
- When a table with number 0 is shown you can enter the number by selecting the table.
- Any number can be assigned to a table (including decimal point). When the table is selected the register will use
the programmed number as if it was entered on the keyboard so when you program a non existing table number
the register will give an error unless you have activated “free assignment” of table numbers in the configuration.
124: Reserved
Reserved.
131: Reserved
Reserved.
132: Reserved
Reserved.
133: Reserved
Reserved.
134: Reserved
Reserved.
135: Reserved
Reserved.
System Options
System Options
NOTE:
If not set the register will consolidate items with the same modifiers and no item discounts. Note that the
modifiers must be in the same sequence.
Mode 100, 101, 102 and 103 are only active when Random Plu Codes are used!!
100 –> SUBTOTAL for Re-Indexing Random PLU file (Merge & Delete).
101 –> SUBTOTAL for Re-Indexing Random PLU file (Merge Only).
102 –> SUBTOTAL for Re-Indexing Random PLU file (Delete Only).
103 –> SUBTOTAL for Print Records Used Random PLU file.
NOTE:
When Separate Tickets is active the register will print a separate ticket with the Total amount.
- When the key is pressed before payment the register will suppress the selected tax and print the TAX amount
as “***0,00”.
- When BALANCES are used the MANUAL TAX EXEMPT will only work when the BALANCE is paid. The
register will ALWAYS store the TAX on the BALANCE. When the MANUAL TAX EXEMPT key is pressed before
printing the register will print the negative tax and deduct it from the balance. When pressed before subtotal the
register will display the subtotal without the TAX.
- The register will still report the TAXABLE sales only the TAX in the report is not updated.
- OPTION 155 is not used when OPTION 158 is SET.
- When MANUAL TAX EXEMPT is only required for ONE tranasction don’t forget to set OPTION 156 otherwise
the MANUAL TAXEXEMPT stays active.
- Once a SLIP is used on a BALANCE re-inserting the SLIP is compulsory even when the OPEN function doesn’t
have the compulsory slip option option set!
- When a SLIP printer which doesn’t support re-insertion is used the register will also feed the paper!
- When OPTION 160 is set EMPTY (SPACE LINES) are not printed on the SLIP to save space.
- Disable to SLIP TRAILER to save space.
- Set OPTION 35 so it is possible to close directly on a tendering function.
- Remove GENERAL MESSAGE 53 (No Invoice) when required.
- Check SLIP START (PARAMETER 73) and SLIP LENGTH (PARAMETER 75).
When you set SYSTEM OPTION 170 you MUST start a transaction by entering a number on the special Drawer
Number entry function (see above).
- ERROR# 55 (Enter Number) will be shown when you don’t enter the number.
- When you connect a scanner which can read alphanumeric codes the register will automatically read the code
and process it on the LAST drawer function when scanned at the start of the transaction so you must make the
LAST drawer function the special number entry function.
- When this option is set the register will automatically activate the ALPHA keboard at the start of a transaction.
- When you sell on a balance the register will update the TAX report when the balance is paid.
- The TAX is reported in the SALESPERSON of the FIRST Tendering function incase a split payment is done.
Example:
DRINK 123.00 (14%VAT, 2%C.Levy, 7%service charge)
MEAL 252.00 (14%VAT, 2%C.Levy, 10%service charge)
---------------------------------
TOTAL 375.00
VAT 42.00
C.Levy 6.00
S.Charge7% 7.00
S.Charge10% 20.00
Time Zones
Editing the Time Zone start times depending on the configuration there are maximum 48 time zones. The time
must be entered using the 24 hour clock and the format is “hhmm” where “hh” are the hours and “mm” are the
minutes (1300 is 13:00 or 1:00 PM).
LEVEL#:
When PLU Price levels are used it is possible to select automatically a (base) pricelevel according to the
current time zone. At the start of a transaction the register will read the clock and select the pricelevel as
programmed for this time zone (programmed time is start time for the level!). Note that this overrules a
selection made by keyboard only SHIFT ON SHIFT will still work. When a value of ZERO is programmed
the register will NOT change the pricelevel. When selecting the level by default TIME ZONES have the
highest priority followed by DAY OF THE WEEK ZONES, DAY OF THE MONTH ZONES and DATE TO
DATE ZONES. So when there is NO LEVEL programmed for a specific ZONE the register will check the
next ZONE level. When OPTION 132 is SET then DATE TO DATE zones have the highest priority so the
TIME ZONE is only checked when all higher ZONES don’t select a price level.
LEVEL#:
When PLU Price levels are used it is possible to select automatically a (base) pricelevel according to the
current day of the week zone. At the start of a transaction the register will read the clock and select the
pricelevel as programmed for this day of the week zone (programmed day of the week is start day for the
level!). Note that this overrules a selection made by keyboard only SHIFT ON SHIFT will still work. When
a value of ZERO is programmed the register will NOT change the pricelevel. When selecting the level
DAY OF THE WEEK ZONES have priority after (or when OPTION 132 before) the TIME ZONE. This
means that when TIME ZONES (or DAY of the MONTH ZONES when OPTION 132 is set) don’t select a
level the register will select the DAY OF THE WEEK level if programmed.
QProg Rel 1.69 - 119-
Printed on 7-12-21
Day of the Month Zones
Editing the Day of the Month start days. You must enter the day of the month number which start at 1 and
maximum is 31 (see also SYSTEM PARAMETER 110).
LEVEL#:
When PLU Price levels are used it is possible to select automatically a (base) pricelevel according to the
current day of the month zone. At the start of a transaction the register will read the clock and select the
pricelevel as programmed for this day of the month zone (programmed day of the month is start day for
the level!). Note that this overrules a selection made by keyboard only SHIFT ON SHIFT will still work.
When a value of ZERO is programmed the register will NOT change the pricelevel. When selecting the
level DAY OF THE MONTH ZONES have priority after (or when OPTION 132 before) the DAY OF THE
WEEK ZONES. This means that when the previous ZONES don’t select a level the register will select the
DAY OF THE MONTH level if programmed.
LEVEL#:
When PLU Price levels are used it is possible to select automatically a (base) pricelevel according to the
current date zone. At the start of a transaction the register will read the clock and select the pricelevel as
programmed for this date zone (programmed date is start date for the level!). Note that this overrules a
selection made by keyboard only SHIFT ON SHIFT will still work. When a value of ZERO is programmed
the register will NOT change the pricelevel. When selecting the level DATE ZONES have the lowest (or
when OPTION 132 is set the HIGHEST) priority. This means that when the previous ZONES don’t select
a level the register will select the DATE ZONE level if programmed or when OPTION 132 is set always
select the programmed level.
Receipt Header
Editing the receipt header. The receipt header can have a maximum of 9 lines of each 40 characters. The number
of lines can be changed by the text lines list box. When a longer name then allowed is entered only the
programmed length is stored. On the most right side of each line you can select the FONT (1-8) for this line. See
“FILE -> PRINT OPTIONS” for more details on the available fonts.
NOTE:
The cash register will automatically center each line of the receipt header before printing. When you don’t
want to center a line you must fill it up with spaces.
Receipt Trailer
Editing the receipt trailer. The receipt trailer can have a maximum of 9 lines of each 40 characters. The number of
lines can be changed by the text lines list box. When a longer name then allowed is entered only the programmed
length is stored. On the most right side of each line you can select the FONT (1-8) for this line. See “FILE ->
PRINT OPTIONS” for more details on the available fonts.
NOTE:
The cash register will automatically center each line of the receipt trailer before printing. When you don’t
want to center a line you must fill it up with spaces.
Slip Header
Editing the slip header. The slip header can have a maximum of 9 lines of each 40 characters. The number of
lines can be changed by the text lines list box. When a longer name then allowed is entered only the programmed
length is stored. On the most right side of each line you can select the FONT (1-8) for this line. See “FILE ->
PRINT OPTIONS” for more details on the available fonts.
NOTE:
The cash register will automatically center each line of the slip header before printing. When you don’t
want to center a line you must fill it up with spaces.
Slip Trailer
Editing the slip trailer. The slip trailer can have a maximum of 9 lines of each 40 characters. The number of lines
can be changed by the text lines list box. When a longer name then allowed is entered only the programmed
length is stored. On the most right side of each line you can select the FONT (1-8) for this line. See “FILE ->
PRINT OPTIONS” for more details on the available fonts.
NOTE:
The cash register will automatically center each line of the slip trailer before printing. When you don’t want
to center a line you must fill it up with spaces.
Tare Table
In this table 10 predefined tare weights can be programmed which can be selected using a key. The selected tare
weight is deducted from the weight received from a scale when an item is scalable and the option compulsory tare
is set in other cases error# 1 (Invalid Entry) is given when a tare is selected. The price is calculated using the
NET weight (Gross minusTare). The weight is fixed to 3 decimals and is entered in grams.
Fixed Texts
Changing the fixed texts in the application program. These texts are fixed so it is not required to change them for
every application program once they are translated into the local language. When in the configuration menu the
General Texts
This table contains general texts like SUBTOTAL, QUANTITY, LOCK POSITIONS etc. which are used for
printing and displaying information on the receipts and display. There are maximum 128 messages with a
maximum length of 16 characters.
Error Messages
This table contains error messages like “INVALID ENTRY”, “SELECT CLERK” etc. which are used to signal
operating errors or general error conditions. There are maximum 128 messages with a maximum length of 25
characters.
General Messages
This table contains general and status messages like “NEXT PLEASE”, “CLEARING MEMORY” etc. which are
used to inform about the current status and/or guide the operator. There are maximum 128 messages with a
maximum length of 25 characters.
Month Names
This table contains the names of the months of the year. There are maximum 12 months with a maximum length
of 13 characters.
Programming Texts
This table contains the names of the programming menu and options which are printed and shown on the register
during programming using the keyboard. There are maximum 128 texts with a maximum length of 8 characters.
Keyboard
Keytable Screen
In this part of the screen the key table is shown. The size and appearance of the key table depend on the
selected keyboard type. When you want to program or change the function of the key you must click on the key
with your mouse or select the key number in the key info filed. On the right bottom side of the screen the KEY
INFO field is shown with the current function of the key.
Keyboard Number
When in Keyboard File configuration is specified that there are multiple keyboards available you can select the
keyboard you are programming and also change the name of the keyboard.
Keyboard Type
You can select the type of keyboard. It depends on the hardware of the register you are programming. It is
possible to select:
Standard 64 keys
Standard 104 keys
Flat 128 keys
Flat 156 keys
Qtouch 56 keys
Qtouch 56 graphic
Concerto Touch 44 (64K Colors)
Concerto Touch 56 (64K Colors)
Standard 40 keys
When you select a different type of keyboard the screen will be updated according to the selected keyboard.
When you have a 156 Flat keyboard and more then ONE level don’t forget to set LARGE KEYBOARDS in the
Keyboard Level Configuration.
When a 64K color type of keyboard is selected it is possible to use bitmaps with 64K colors when the option “64K
Color Key Bitmaps” is marked. Qprog will automatically convert between 64K and 256 colors depending on the
type of keyboard selected. Note that the conversion from 64K to 256 is irreversible!
Default Text
When selected this key will display the default function text which is programmed in the application.
Bitmap
When selected this key displays a bitmap.
Notes Qtouch:
On the “QTouch 56 keys” it is not possible to display bitmaps you need to select “Qtouch 56 Graphic Keys” if
required and be sure your Qtouch supports this keyboard type. The bitmaps displayed have a fixed format of 256
colors. The size for the small keys is 69 x 53 pixels and the large keys 91 x 53 pixels. From release 1.60 and
newer it is possible to use 64K color bitmaps for the Concerto and Qtouch-2 when the option “64K Color Key
Bitmaps” is marked.
Clear
When selected the key is cleared.
Background Color
When selected you can change the background color of the key. Note that for the Qtouch keyboard there is a
fixed 256 color table.
Font Type
When selected you can change the text color and font of the key. Note that for the Qtouch keyboard there is a
fixed 256 color table and that you can only change the size of the font.
Select All
When selected all keys will be selected so it is possible to change all keys at once.
Fill Range
When selected Qprog will fill the selected range with the following functions of the first key in the selection.
Reset to Default
When selected Qprog will reset the select key to the Default Text.
Save to Keyfile
When selected you can store the current keyboard.
Print Keyboard
It is possible to print a copy of the keyboard so you can use it for the cash register. The size of the printed
keyboard is automatically adapted to the selected keyboard type.
Key Number
In this field the number of the selected key is shown. It can also be used to go directly to a key by selecting the
key number.
Key Code
In this field the key code of the selected key is shown. It can also be used change the function of the key by
entering the key code directly. The following key codes are available:
Key Type
In this field the type of the selected key is shown. You can change the function of the key by selecting another
type.
PLU Code#
When you are using scan codes for articles this field is shown when the key is an fixed article key. When you
want to change the article on the key you must enter the scan code in this field.
Function Number
In this field the function number (record number) of the selected key is shown. You can change the function by
selecting another number.
NOTE:
This field is not shown when the type of key is a fixed function or when the type is PLU and scan codes
are used.
Function Text
In this field the name or text of the selected function is show. You can change the function number by selecting
another function.
System Key
When the central lock of the register is not in Registration (R) or Manager (P) mode the system keyboard is
active. This keyboard is used for programming and reporting. When you select as System Key the ASCII type an
additional field is shown in which you can program the ASCII character by typing the required character. Note that
you must program the upper case character because the CAPS key will change the character to lower case. In
addition to the ASCII key the following System Keys are available:
Reporting
This chapter describes in detail the options in the Reporting Menu. It is possible to get, view or delete a User
Report.
Get Report
REPORT
Select the User Report Number you want take from the register. The maximum number is 102. Default the report
is taken in X-mode when you want to take it in Z-mode you must select ‘Z’.
CLERK
When the User Report you want to take is programmed as a single clerk report it is possible to select a specific
clerk. Default it is set to Clerk 1. When taking a normal report you can leave it set to Clerk 1.
SALESPERSON
When the User Report you want to take is programmed as a single salesperson report it is possible to select a
specific salesperson. Default it is set to Salesperson 1. When taking a normal report you can leave it set to
Salesperson 1.
NOTE:
When a report is taken the “View Report” screen is automatically displayed.
View Report
Selecting this option will allow you to select a report file and view, delete or print it. When printing the file the page
is automatically set to landscape when the report contains more then 7 columns. On the top of the page it will
print the Report Name, Receipt Header Line# 2 (if programmed) and Time & Date which it received from the
register.
Communication
Dial
This menu option allows you to make a connection to a remote cash register using a modem. You are asked to
enter the phone number and QPROG will try to make the connection. Note that when a connection is already
active it will ask you if you want to hang up first also when a connection is active and QPROG is closed the
register will automatically disconnect. QPROG will automatically remember the last entered phone number.
Hang Up
This menu option allows you to sent a HANG UP command to the connected modem. Note that QPROG will
ALWAYS sent the hangup command also when there is no connection. When a connection is active and QPROG
is closed the register will automatically disconnect.
Com Port
Select the Computer COM port which is used to communicate with the cash register. Don’t forget to (re-) connect
the cable to correct port when changing this port number.
NOTE:
This the port number ON the COMPUTER and not the port number on the cash register. The port number on the
cash register is programmed in SYSTEM PARAMETER 001.
Baud Rate
Select the baud rate you want to use for communication with the cash register. The baud rate must be the same
as programmed in the cash register SERIAL PORT SYSTEM PARAMETER (002-007) which is used for
computer communication.
Direct Connection
This menu option indicates that there is a direct connection. When this option is marked QPROG will
communicate directly with the connected register. You can select it by clicking on this menu option. Note that the
records used during direct communication are different from network connection. The register should always
respond to this type of connection.
Network Connection
This menu option indicates that there is a network connection. When this option is marked QPROG will
communicate with a register in the network. You can select it by clicking on this menu option. QProg will ask you
for the register number before communication is started. Note that the records used during network
communication are different from a direct connection. When the selected register or the register to which the
computer is connected doesn’t have the network active there will be no communication.
In most cases the init string : AT&FE0Q1S0=1&W will be ok. Configuring of the modem can be done using
HYPERTERMINAL in MS-Windows or by using a special command file with QDRIVER (see QDRIVER
documentation). After programming the modem it should be powered off/on to check if the configuration is stored
correctly.
Report Format
With this option you can specify how QPROG should store the received reports. Default it is stored in CSV format
but it is also possible to store it in BINARY or in BOTH formats (in separate files).
Dial Prompting
When this option is marked QPROG will automatically prompt for a connection when there is no connection and
communication with the cash register is started.
Help
Contents
Selecting this option will display the main HELP INDEX screen which will show you the help divided into chapters.
Each chapter explains an option in the MAIN MENU. It is also possible to get online help in the program by
pressing the HELP button or the F1-key.
Each CHAPTER is divided into SECTIONS and a SECTION can be divided into ITEMS. When you select a
chapter the next screen will show the available sections. When you select a section the next screen will show the
available items if applicable or the help on the selected section. The help system is divided into CHAPTERS,
SECTION and ITEMS.
INDEX BUTTON
When selecting this button the help system will go back to the main help index.
FIND BUTTON
It is possible to look for a specific string in the help text which is shown on the screen. After pressing this button
you will be asked to enter the string you want the search for. Note that this option is only active when there is a
help text shown on the screen.
PRINT BUTTON
It is possible to print the contents of the help screen which is currently on the screen. Note that this option is only
active when there is a help text shown on the screen.
CLOSE BUTTON
When selecting this button the help system is closed. You can also close the help system by pressing the
ESCAPE-key.
When there is help on the screen the top lines will show the chapter in blue, the section in green and the item in
black. It is possible to go back to a previous level by clicking on the level text.
About
Selecting this option will display the “About Box” which contains information about the program release.