RC Pile Cap Design (ACI318) - 4-GRID-C4
RC Pile Cap Design (ACI318) - 4-GRID-C4
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 1
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
4
3
1800 mm
2
1
1800 mm
;
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 2
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
102 mm
500 mm
;
Pile cap details
Pile cap width, along x axis; Lx = 1800 mm
Pile cap width, along y axis; Ly = 1800 mm
Total cap depth; Dcap = 500 mm
Density of concrete; conc = 24 kN/m3
Height of soil above pile cap; hsoil = 0 mm
Density of soil above pile cap; soil = 17 kN/m3
Column details
Column width, along x axis; lx,col = 400 mm
Column width, along y axis; ly,col = 600 mm
Column location, x axis; xc = 900 mm
Column location, y axis; yc = 900 mm
Pile details
Pile material; Concrete
Concrete pile section; Circular
Pile diameter; hpile = 300 mm
Allowable axial compression load; PpC,allow = 662.9 kN
Allowable axial tension load; PpT,allow = 366.7 kN
Allowable lateral load; Vp,allow = 92.9 kN
Number of piles; Np = 4.000
Pile embedment; dembed = 102 mm
Pile number x location (mm) y location (mm)
1 450 468
2 1327 512
3 376 1384
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 3
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
4 1314 1427
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.222 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.665 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.170
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD1) = 62.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.142 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.108
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD1) = 78.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.171 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 15
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Vu / Vn = 0.183
PASS - Design shear capacity exceeds ultimate shear load
Combination 2 results: 1.2D + 1.6L + 0.5Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 54.4 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.131
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 37.3 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.096
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 17
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2156.7 kN
Design shear capacity; Vn = v Vn = 1617.5 kN
Vu / Vn = 0.129
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD2,Pp2,LRFD2,Pp3,LRFD2,Pp4,LRFD2) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 350.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.418 MPa
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.099 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.950 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.319
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2 (lx,col) + 2 (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD2,Pp2,LRFD2,Pp3,LRFD2,Pp4,LRFD2) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 328.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.514 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 1.201 MPa
vumod / vn = 0.428
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 19
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD2) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.179 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD2) = 104.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 598.5 kN
Design shear capacity; Vn = v Vn = 448.9 kN
Vu / Vn = 0.232
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD2) = 120.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 21
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 626.1 kN
Design shear capacity; Vn = v Vn = 469.5 kN
Vu / Vn = 0.257
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD2) = 64.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 547.5 kN
Design shear capacity; Vn = v Vn = 410.6 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD2) = 82.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 574.7 kN
Design shear capacity; Vn = v Vn = 431.0 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 29.9 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 118.0 kN
Ultimate moment force at face of column; Mu = 42.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 553.6 kN
Design shear capacity; Vn = v Vn = 415.2 kN
Vu / Vn = 0.284
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 145.1 kN
Ultimate moment force at face of column; Mu = 42.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 23
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 841.0 kN
Design shear capacity; Vn = v Vn = 630.7 kN
Vu / Vn = 0.230
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 105.7 kN
Ultimate moment force at face of column; Mu = 29.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 799.9 kN
Design shear capacity; Vn = v Vn = 600.0 kN
Vu / Vn = 0.176
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 162.6 kN
Ultimate moment force at face of column; Mu = 28.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2178.5 kN
Design shear capacity; Vn = v Vn = 1633.9 kN
Vu / Vn = 0.100
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD3,Pp2,LRFD3,Pp3,LRFD3,Pp4,LRFD3) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 277.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.331 MPa
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.099 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.950 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 24
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 118.0 kN
Ultimate moment force at face of column; Mu = 42.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 553.6 kN
Design shear capacity; Vn = v Vn = 415.2 kN
Vu / Vn = 0.284
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 145.1 kN
Ultimate moment force at face of column; Mu = 42.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 841.0 kN
Design shear capacity; Vn = v Vn = 630.7 kN
Vu / Vn = 0.230
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 105.7 kN
Ultimate moment force at face of column; Mu = 29.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 799.9 kN
Design shear capacity; Vn = v Vn = 600.0 kN
Vu / Vn = 0.176
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 162.6 kN
Ultimate moment force at face of column; Mu = 28.4 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 29
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.250 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.191
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD5) = 151.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 598.5 kN
Design shear capacity; Vn = v Vn = 448.9 kN
Vu / Vn = 0.337
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD5) = 176.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 626.1 kN
Design shear capacity; Vn = v Vn = 469.5 kN
Vu / Vn = 0.375
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD5) = 88.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 547.5 kN
Design shear capacity; Vn = v Vn = 410.6 kN
Vu / Vn = 0.216
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 38
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 1.201 MPa
vumod / vn = 0.334
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD6) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.172 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.746 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD6) = 95.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.190 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.665 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.145
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 42
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Vu / Vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD7) = 67.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 574.7 kN
Design shear capacity; Vn = v Vn = 431.0 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 8 results: 1.2D + 1.6Lr + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 99.8 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.241
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 69.2 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 50
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.821 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 1.201 MPa
vumod / vn = 0.683
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD8) = 167.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.349 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.746 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.267
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD8) = 235.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.469 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.665 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.358
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 53
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 598.5 kN
Design shear capacity; Vn = v Vn = 448.9 kN
Vu / Vn = 0.374
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD8) = 235.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 626.1 kN
Design shear capacity; Vn = v Vn = 469.5 kN
Vu / Vn = 0.501
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD8) = 45.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 547.5 kN
Design shear capacity; Vn = v Vn = 410.6 kN
Vu / Vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD8) = 118.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 574.7 kN
Design shear capacity; Vn = v Vn = 431.0 kN
Vu / Vn = 0.276
PASS - Design shear capacity exceeds ultimate shear load
Combination 9 results: 1.2D + 1.6S + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 61.4 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 55
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 725.0 kN
Design shear capacity; Vn = v Vn = 543.7 kN
Vu / Vn = 0.122
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 238.4 kN
Ultimate moment force at face of column; Mu = 41.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2178.2 kN
Design shear capacity; Vn = v Vn = 1633.7 kN
Vu / Vn = 0.146
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD10,Pp2,LRFD10,Pp3,LRFD10,Pp4,LRFD10) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 313.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.375 MPa
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.099 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.950 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.286
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 63
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 683.8 kN
Design shear capacity; Vn = v Vn = 512.8 kN
Vu / Vn = 0.191
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 310.2 kN
Ultimate moment force at face of column; Mu = 92.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 815.5 kN
Design shear capacity; Vn = v Vn = 611.6 kN
Vu / Vn = 0.507
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 52.5 kN
Ultimate moment force at face of column; Mu = 16.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 617.9 kN
Design shear capacity; Vn = v Vn = 463.4 kN
Vu / Vn = 0.113
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 360.9 kN
Ultimate moment force at face of column; Mu = 63.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2165.5 kN
Design shear capacity; Vn = v Vn = 1624.1 kN
Vu / Vn = 0.222
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 68
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.427 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.665 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.326
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD12) = 31.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.073 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD12) = 74.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.161 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 76
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Vu / Vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Combination 13 results: 1.2D + 1.0L + 0.5R + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 80.3 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.194
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 54.8 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.141
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 78
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2178.1 kN
Design shear capacity; Vn = v Vn = 1633.6 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 350.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.418 MPa
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.099 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.950 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.319
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2 (lx,col) + 2 (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 328.8 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.515 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 1.201 MPa
vumod / vn = 0.428
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 80
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.073 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD13) = 74.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.161 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.123
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD13) = 115.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 598.5 kN
Design shear capacity; Vn = v Vn = 448.9 kN
Vu / Vn = 0.258
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD13) = 214.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 82
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 626.1 kN
Design shear capacity; Vn = v Vn = 469.5 kN
Vu / Vn = 0.456
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD13) = 31.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 547.5 kN
Design shear capacity; Vn = v Vn = 410.6 kN
Vu / Vn = 0.078
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD13) = 74.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 574.7 kN
Design shear capacity; Vn = v Vn = 431.0 kN
Vu / Vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.320
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 77.0 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.198
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 62.5 kNm
Tension reinforcement provided; (12) 19 mm top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 545.1 kNm
Mu / Mn = 0.115
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 84
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.751 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.665 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.573
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD14) = 216.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.492 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.376
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD14) = 85.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.185 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 88
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Vu / Vn = 0.198
PASS - Design shear capacity exceeds ultimate shear load
Combination 15 results: 0.9D + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 69.7 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.168
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 47.7 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.123
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 90
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2178.0 kN
Design shear capacity; Vn = v Vn = 1633.5 kN
Vu / Vn = 0.167
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD15,Pp2,LRFD15,Pp3,LRFD15,Pp4,LRFD15) - 0.9 (conc Dcap)
(Acap - AInsidePerim)) = 280.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.335 MPa
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.099 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.950 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.256
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2 (lx,col) + 2 (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD15,Pp2,LRFD15,Pp3,LRFD15,Pp4,LRFD15) - 0.9 (conc Dcap)
(Acap - AInsidePerim)) = 264.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.414 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 1.201 MPa
vumod / vn = 0.345
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 92
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.103 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.079
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD15) = 57.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.124 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.095
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD15) = 95.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 598.5 kN
Design shear capacity; Vn = v Vn = 448.9 kN
Vu / Vn = 0.212
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD15) = 190.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 94
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 626.1 kN
Design shear capacity; Vn = v Vn = 469.5 kN
Vu / Vn = 0.405
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD15) = 45.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 547.5 kN
Design shear capacity; Vn = v Vn = 410.6 kN
Vu / Vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD15) = 57.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 574.7 kN
Design shear capacity; Vn = v Vn = 431.0 kN
Vu / Vn = 0.133
PASS - Design shear capacity exceeds ultimate shear load
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.274
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 64.2 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.165
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 81.5 kNm
Tension reinforcement provided; (12) 19 mm top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 545.1 kNm
Mu / Mn = 0.150
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 96
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.665 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.665 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.508
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD16) = 240.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.547 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.916 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.418
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD16) = 54.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.119 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.822 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 100
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Vu / Vn = 0.127
PASS - Design shear capacity exceeds ultimate shear load
1800 mm
;
;