0% found this document useful (0 votes)
106 views101 pages

RC Pile Cap Design (ACI318) - 4-GRID-C4

This document summarizes the analysis and design of a pile cap supporting a column for a building project. It includes load calculations and summaries of the pile cap and pile designs. The pile cap was analyzed for flexural reinforcement, shear strength, and pile shear strength according to ACI 318-11 code. All demand to capacity ratios were found to pass the code requirements. Pile axial loads and moments induced in each pile by the column loads were also calculated.

Uploaded by

Prima Adhiyasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views101 pages

RC Pile Cap Design (ACI318) - 4-GRID-C4

This document summarizes the analysis and design of a pile cap supporting a column for a building project. It includes load calculations and summaries of the pile cap and pile designs. The pile cap was analyzed for flexural reinforcement, shear strength, and pile shear strength according to ACI 318-11 code. All demand to capacity ratios were found to pass the code requirements. Pile axial loads and moments induced in each pile by the column loads were also calculated.

Uploaded by

Prima Adhiyasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 101

Project Job Ref.

N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 1
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PILE CAP ANALYSIS & DESIGN (ACI318-11)


In accordance with ACI318-11
Tedds calculation version 2.0.00

Pile analysis summary


Unit Applied Allowable Utilization Result
Pile axial compression, pile 2 kN 277 663 0.417 PASS
Pile axial tension, pile 3 kN 170 367 0.464 PASS
Pile cap design summary
Unit Required Provided Utilization Result
Flexural reinforcement mm2 1620 (min) 3402 0.476 PASS
One way modified shear kN 442 605 0.731 PASS
Two way column shear MPa 0.652 1.310 0.498 PASS
Two way col. mod. shear MPa 0.821 1.201 0.683 PASS
Two way pile shear MPa 0.751 1.310 0.573 PASS
One way corner pile shear kN 377 470 0.803 PASS

4
3
1800 mm

2
1

1800 mm

;
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 2
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

102 mm
500 mm

;
Pile cap details
Pile cap width, along x axis; Lx = 1800 mm
Pile cap width, along y axis; Ly = 1800 mm
Total cap depth; Dcap = 500 mm
Density of concrete; conc = 24 kN/m3
Height of soil above pile cap; hsoil = 0 mm
Density of soil above pile cap; soil = 17 kN/m3

Column details
Column width, along x axis; lx,col = 400 mm
Column width, along y axis; ly,col = 600 mm
Column location, x axis; xc = 900 mm
Column location, y axis; yc = 900 mm
Pile details
Pile material; Concrete
Concrete pile section; Circular
Pile diameter; hpile = 300 mm
Allowable axial compression load; PpC,allow = 662.9 kN
Allowable axial tension load; PpT,allow = 366.7 kN
Allowable lateral load; Vp,allow = 92.9 kN
Number of piles; Np = 4.000
Pile embedment; dembed = 102 mm
Pile number x location (mm) y location (mm)
1 450 468
2 1327 512
3 376 1384
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 3
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

4 1314 1427

Column axial loads


Axial dead load; PD = 210.6 kN
Total area axial dead load; PD,area = conc  Lx  Ly  Dcap = 38.9 kN
Axial rooflive load; PLr = 145.1 kN
Axial wind load; PW = 72.6 kN
Axial seismic load; PE = 11.7 kN
Column shear loads
Shear dead load, along x axis; VxD = 0.8 kN
Shear rooflive load, along x axis; VxLr = 0.6 kN
Shear wind load, along x axis; VxW = 12.2 kN
Shear seismic load, along x axis; VxE = 32.8 kN
Shear dead load, along y axis; VyD = 3.4 kN
Shear rooflive load, along y axis; VyLr = 3.5 kN
Shear wind load, along y axis; VyW = 15.4 kN
Shear seismic load, along y axis; VyE = 36.9 kN
Column moment loads
Moment dead load, about x-x axis; MxD = 12.9 kNm
Moment rooflive load, about x-x axis; MxLr = 13.4 kNm
Moment wind load, about x-x axis; MxW = 106.0 kNm
Moment seismic load, about x-x axis; MxE = 253.7 kNm
Moment dead load, about y-y axis; MyD = 3.9 kNm
Moment rooflive load, about y-y axis; MyLr = 2.8 kNm
Moment wind load, about y-y axis; MyW = 77.1 kNm
Moment seismic load, about y-y axis; MyE = 246.4 kNm
Pile group centroid
Centroid location, x direction; xpg,c = (xp1 + xp2 + xp3 + xp4) / Np = 867 mm
Centroid location, y direction; ypg,c = (yp1 + yp2 + yp3 + yp4) / Np = 948 mm
Pile distance from centroid
Pile 1 centroid distance, x direction; xp1,c = xp1 - xpg,c = -417 mm
Pile 1 centroid distance, y direction; yp1,c = yp1 - ypg,c = -480 mm
Pile 2 centroid distance, x direction; xp2,c = xp2 - xpg,c = 460 mm
Pile 2 centroid distance, y direction; yp2,c = yp2 - ypg,c = -436 mm
Pile 3 centroid distance, x direction; xp3,c = xp3 - xpg,c = -491 mm
Pile 3 centroid distance, y direction; yp3,c = yp3 - ypg,c = 437 mm
Pile 4 centroid distance, x direction; xp4,c = xp4 - xpg,c = 448 mm
Pile 4 centroid distance, y direction; yp4,c = yp4 - ypg,c = 479 mm
Moment of inertia of pile group
Moment of inertia about x-x axis; Ixx = yp1,c2 + yp2,c2 + yp3,c2 + yp4,c2 = 840269 mm2
Moment of inertia about y-y axis; Iyy = xp1,c2 + xp2,c2 + xp3,c2 + xp4,c2 = 826767 mm2
Loading eccentricity
Eccentricity of column load, x direction; ex,c = xc - xpg,c = 33 mm
Eccentricity of column load, y direction; ey,c = yc - ypg,c = -48 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 4
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Dead load pile forces


Dead load moment about x-x axis; MxD,Des = MxD + (-1)  PD  ey,c + (-1)  VyD  Dcap = 21.2 kNm
Dead load moment about y-y axis; MyD,Des = MyD + PD  ex,c + VxD  Dcap = 11.3 kNm
Dead axial load on pile 1; Pp1,D = (PD + PD,area) / Np + MyD,Des  xp1,c / Iyy + MxD,Des  (-1)  yp1,c / Ixx = 69
kN
Dead axial load on pile 2; Pp2,D = (PD + PD,area) / Np + MyD,Des  xp2,c / Iyy + MxD,Des  (-1)  yp2,c / Ixx = 80
kN
Dead axial load on pile 3; Pp3,D = (PD + PD,area) / Np + MyD,Des  xp3,c / Iyy + MxD,Des  (-1)  yp3,c / Ixx = 45
kN
Dead axial load on pile 4; Pp4,D = (PD + PD,area) / Np + MyD,Des  xp4,c / Iyy + MxD,Des  (-1)  yp4,c / Ixx = 56
kN

RoofLive load pile forces


RoofLive load moment about x-x axis; MxLr,Des = MxLr + (-1)  PLr  ey,c + (-1)  VyLr  Dcap = 18.6 kNm
RoofLive load moment about y-y axis; MyLr,Des = MyLr + PLr  ex,c + VxLr  Dcap = 7.9 kNm
RoofLive axial load on pile 1; Pp1,Lr = PLr / Np + MyLr,Des  xp1,c / Iyy + MxLr,Des  (-1)  yp1,c / Ixx = 43 kN
RoofLive axial load on pile 2; Pp2,Lr = PLr / Np + MyLr,Des  xp2,c / Iyy + MxLr,Des  (-1)  yp2,c / Ixx = 50 kN
RoofLive axial load on pile 3; Pp3,Lr = PLr / Np + MyLr,Des  xp3,c / Iyy + MxLr,Des  (-1)  yp3,c / Ixx = 22 kN
RoofLive axial load on pile 4; Pp4,Lr = PLr / Np + MyLr,Des  xp4,c / Iyy + MxLr,Des  (-1)  yp4,c / Ixx = 30 kN

Wind load pile forces


Wind load moment about x-x axis; MxW,Des = MxW + (-1)  PW  ey,c + (-1)  VyW  Dcap = 101.8 kNm
Wind load moment about y-y axis; MyW,Des = MyW + PW  ex,c + VxW  Dcap = 85.6 kNm
Wind axial load on pile 1; Pp1,W = PW / Np + MyW,Des  xp1,c / Iyy + MxW,Des  (-1)  yp1,c / Ixx = 33 kN
Wind axial load on pile 2; Pp2,W = PW / Np + MyW,Des  xp2,c / Iyy + MxW,Des  (-1)  yp2,c / Ixx = 119 kN
Wind axial load on pile 3; Pp3,W = PW / Np + MyW,Des  xp3,c / Iyy + MxW,Des  (-1)  yp3,c / Ixx = -86 kN
Wind axial load on pile 4; Pp4,W = PW / Np + MyW,Des  xp4,c / Iyy + MxW,Des  (-1)  yp4,c / Ixx = 6 kN

Seismic load pile forces


Seismic load moment about x-x axis; MxE,Des = MxE + (-1)  PE  ey,c + (-1)  VyE  Dcap = 235.8 kNm
Seismic load moment about y-y axis; MyE,Des = MyE + PE  ex,c + VxE  Dcap = 263.1 kNm
Seismic axial load on pile 1; Pp1,E = PE / Np + MyE,Des  xp1,c / Iyy + MxE,Des  (-1)  yp1,c / Ixx = 5 kN
Seismic axial load on pile 2; Pp2,E = PE / Np + MyE,Des  xp2,c / Iyy + MxE,Des  (-1)  yp2,c / Ixx = 272 kN
Seismic axial load on pile 3; Pp3,E = PE / Np + MyE,Des  xp3,c / Iyy + MxE,Des  (-1)  yp3,c / Ixx = -276 kN
Seismic axial load on pile 4; Pp4,E = PE / Np + MyE,Des  xp4,c / Iyy + MxE,Des  (-1)  yp4,c / Ixx = 11 kN

ASCE 7-10 load combinations (ASD)


1.0D (0.120)
1.0D + 1.0L (0.120)
1.0D + 1.0Lr (0.196)
1.0D + 1.0S (0.120)
1.0D + 1.0R (0.120)
1.0D + 0.75L + 0.75Lr (0.177)
1.0D + 0.75L + 0.75S (0.120)
1.0D + 0.75L + 0.75R (0.120)
1.0D + 0.6W (0.227)
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 5
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

(1.0 + 0.14SDS)D + 0.7E (0.417)


1.0D + 0.75L + 0.75Lr + 0.45W (0.258)
1.0D + 0.75L + 0.75S + 0.45W (0.201)
1.0D + 0.75L + 0.75R + 0.45W (0.201)
(1.0 + 0.10SDS)D + 0.75L + 0.75S + 0.525E (0.343)
0.6D + 0.6W (0.179)
(0.6 - 0.14SDS)D + 0.7E (0.464)

Combination 1 results: 1.0D


Pile 1 axial load; Pp1 = 1.0  Pp1,D = 68.8 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D = 79.7 kN
max(Pp2 / PpC,allow,0) = 0.120
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D = 44.7 kN
max(Pp3 / PpC,allow,0) = 0.067
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D = 56.4 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 2 results: 1.0D + 1.0L
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,L = 68.8 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,L = 79.7 kN
max(Pp2 / PpC,allow,0) = 0.120
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,L = 44.7 kN
max(Pp3 / PpC,allow,0) = 0.067
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,L = 56.4 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 3 results: 1.0D + 1.0Lr
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,Lr = 111.7 kN
max(Pp1 / PpC,allow,0) = 0.169
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,Lr = 130 kN
max(Pp2 / PpC,allow,0) = 0.196
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,Lr = 66.6 kN
max(Pp3 / PpC,allow,0) = 0.100
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,Lr = 86.3 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 6
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

max(Pp4 / PpC,allow,0) = 0.130


PASS - Pile allowable compression load exceeds axial force
Combination 4 results: 1.0D + 1.0S
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,S = 68.8 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,S = 79.7 kN
max(Pp2 / PpC,allow,0) = 0.120
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,S = 44.7 kN
max(Pp3 / PpC,allow,0) = 0.067
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,S = 56.4 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 5 results: 1.0D + 1.0R
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,R = 68.8 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,R = 79.7 kN
max(Pp2 / PpC,allow,0) = 0.120
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,R = 44.7 kN
max(Pp3 / PpC,allow,0) = 0.067
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,R = 56.4 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 6 results: 1.0D + 0.75L + 0.75Lr
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,Lr = 101 kN
max(Pp1 / PpC,allow,0) = 0.152
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,Lr = 117.4 kN
max(Pp2 / PpC,allow,0) = 0.177
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,Lr = 61.1 kN
max(Pp3 / PpC,allow,0) = 0.092
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,Lr = 78.8 kN
max(Pp4 / PpC,allow,0) = 0.119
PASS - Pile allowable compression load exceeds axial force
Combination 7 results: 1.0D + 0.75L + 0.75S
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S = 68.8 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 7
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

max(Pp1 / PpC,allow,0) = 0.104


PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S = 79.7 kN
max(Pp2 / PpC,allow,0) = 0.120
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S = 44.7 kN
max(Pp3 / PpC,allow,0) = 0.067
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S = 56.4 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 8 results: 1.0D + 0.75L + 0.75R
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,R = 68.8 kN
max(Pp1 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,R = 79.7 kN
max(Pp2 / PpC,allow,0) = 0.120
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,R = 44.7 kN
max(Pp3 / PpC,allow,0) = 0.067
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,R = 56.4 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 9 results: 1.0D + 0.6W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.6  Pp1,W = 88.7 kN
max(Pp1 / PpC,allow,0) = 0.134
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.6  Pp2,W = 150.8 kN
max(Pp2 / PpC,allow,0) = 0.227
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.6  Pp3,W = -6.7 kN
max(Pp3 / (-1  PpT,allow),0) = 0.018
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.6  Pp4,W = 60.2 kN
max(Pp4 / PpC,allow,0) = 0.091
PASS - Pile allowable compression load exceeds axial force

Combination 10 results: (1.0 + 0.14SDS)D + 0.7E


Pile 1 axial load; Pp1 = 1.085  Pp1,D + 0.7  Pp1,E = 78 kN
max(Pp1 / PpC,allow,0) = 0.118
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.085  Pp2,D + 0.7  Pp2,E = 276.6 kN
max(Pp2 / PpC,allow,0) = 0.417
PASS - Pile allowable compression load exceeds axial force
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 8
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile 3 axial load; Pp3 = 1.085  Pp3,D + 0.7  Pp3,E = -144.5 kN


max(Pp3 / (-1  PpT,allow),0) = 0.394
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.085  Pp4,D + 0.7  Pp4,E = 68.8 kN
max(Pp4 / PpC,allow,0) = 0.104
PASS - Pile allowable compression load exceeds axial force
Combination 11 results: 1.0D + 0.75L + 0.75Lr + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,Lr + 0.45  Pp1,W = 115.9 kN
max(Pp1 / PpC,allow,0) = 0.175
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,Lr + 0.45  Pp2,W = 170.7 kN
max(Pp2 / PpC,allow,0) = 0.258
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,Lr + 0.45  Pp3,W = 22.6 kN
max(Pp3 / PpC,allow,0) = 0.034
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,Lr + 0.45  Pp4,W = 81.7 kN
max(Pp4 / PpC,allow,0) = 0.123
PASS - Pile allowable compression load exceeds axial force
Combination 12 results: 1.0D + 0.75L + 0.75S + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S + 0.45  Pp1,W = 83.7 kN
max(Pp1 / PpC,allow,0) = 0.126
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S + 0.45  Pp2,W = 133 kN
max(Pp2 / PpC,allow,0) = 0.201
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S + 0.45  Pp3,W = 6.2 kN
max(Pp3 / PpC,allow,0) = 0.009
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S + 0.45  Pp4,W = 59.3 kN
max(Pp4 / PpC,allow,0) = 0.089
PASS - Pile allowable compression load exceeds axial force
Combination 13 results: 1.0D + 0.75L + 0.75R + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,R + 0.45  Pp1,W = 83.7 kN
max(Pp1 / PpC,allow,0) = 0.126
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,R + 0.45  Pp2,W = 133 kN
max(Pp2 / PpC,allow,0) = 0.201
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,R + 0.45  Pp3,W = 6.2 kN
max(Pp3 / PpC,allow,0) = 0.009
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,R + 0.45  Pp4,W = 59.3 kN
max(Pp4 / PpC,allow,0) = 0.089
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 9
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Pile allowable compression load exceeds axial force

Combination 14 results: (1.0 + 0.10SDS)D + 0.75L + 0.75S + 0.525E


Pile 1 axial load; Pp1 = 1.06  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S + 0.525  Pp1,E = 75.5 kN
max(Pp1 / PpC,allow,0) = 0.114
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.06  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S + 0.525  Pp2,E = 227 kN
max(Pp2 / PpC,allow,0) = 0.343
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.06  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S + 0.525  Pp3,E = -97.4 kN
max(Pp3 / (-1  PpT,allow),0) = 0.266
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.06  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S + 0.525  Pp4,E = 65.5 kN
max(Pp4 / PpC,allow,0) = 0.099
PASS - Pile allowable compression load exceeds axial force
Combination 15 results: 0.6D + 0.6W
Pile 1 axial load; Pp1 = 0.6  Pp1,D + 0.6  Pp1,W = 61.1 kN
max(Pp1 / PpC,allow,0) = 0.092
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 0.6  Pp2,D + 0.6  Pp2,W = 118.9 kN
max(Pp2 / PpC,allow,0) = 0.179
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 0.6  Pp3,D + 0.6  Pp3,W = -24.5 kN
max(Pp3 / (-1  PpT,allow),0) = 0.067
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 0.6  Pp4,D + 0.6  Pp4,W = 37.7 kN
max(Pp4 / PpC,allow,0) = 0.057
PASS - Pile allowable compression load exceeds axial force

Combination 16 results: (0.6 - 0.14SDS)D + 0.7E


Pile 1 axial load; Pp1 = 0.515  Pp1,D + 0.7  Pp1,E = 38.8 kN
max(Pp1 / PpC,allow,0) = 0.059
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 0.515  Pp2,D + 0.7  Pp2,E = 231.2 kN
max(Pp2 / PpC,allow,0) = 0.349
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 0.515  Pp3,D + 0.7  Pp3,E = -170 kN
max(Pp3 / (-1  PpT,allow),0) = 0.464
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 0.515  Pp4,D + 0.7  Pp4,E = 36.7 kN
max(Pp4 / PpC,allow,0) = 0.055
PASS - Pile allowable compression load exceeds axial force
Pile cap design
Material details
Compressive strength of concrete; f'c = 28.000 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 10
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete type; Normal weight


Concrete modification factor; =1
Yield strength of reinforcement; fy = 420.000 MPa
Nominal cover to top reinforcement; cnom,top = 50 mm
Nominal cover to bottom reinforcement; cnom,bot = 50 mm
ASCE 7-10 load combinations (LRFD)
1.4D (0.476)
1.2D + 1.6L + 0.5Lr (0.476)
1.2D + 1.6L + 1  0.5S (0.476)
1.2D + 1.6L + 0.5R (0.476)
1.2D + 1.0L + 1.6Lr (0.636)
1.2D + 1.0L + 1.6S (0.476)
1.2D + 1.0L + 1.6R (0.476)
1.2D + 1.6Lr + 0.5W (0.683)
1.2D + 1.6S + 0.5W (0.476)
1.2D + 1.6R + 0.5W (0.476)
1.2D + 1.0L + 0.5Lr + 1.0W (0.523)
1.2D + 1.0L + 1  0.5S + 1.0W (0.476)
1.2D + 1.0L + 0.5R + 1.0W (0.476)
(1.2 + 0.2  SDS)D + 1.0L + 1  0.2S + 1.0E (0.803)
0.9D + 1.0W (0.476)
(0.9 - 0.2  SDS)D + 1.0E (0.711)

Combination 1 results: 1.4D


Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 49.5 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.120
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 11
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, positive moment


Ultimate bending moment; Mu = 34.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.090
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 137.7 kN
Ultimate moment force at face of column; Mu = 49.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.332
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 169.3 kN
Ultimate moment force at face of column; Mu = 49.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 841.0 kN
Design shear capacity; Vn = v  Vn = 630.7 kN
Vu / Vn = 0.268
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 12
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 123.3 kN
Ultimate moment force at face of column; Mu = 34.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 799.9 kN
Design shear capacity; Vn = v  Vn = 600.0 kN
Vu / Vn = 0.205
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 189.7 kN
Ultimate moment force at face of column; Mu = 33.1 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.5 kN
Design shear capacity; Vn = v  Vn = 1633.9 kN
Vu / Vn = 0.116
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD1,Pp2,LRFD1,Pp3,LRFD1,Pp4,LRFD1) - 1.4  (conc  Dcap) 
(Acap - AInsidePerim)) = 323.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.387 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.295
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 13
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD1,Pp2,LRFD1,Pp3,LRFD1,Pp4,LRFD1) - 1.4  (conc  Dcap) 
(Acap - AInsidePerim)) = 298.9 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.468 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.389
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD1) = 96.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.201 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.153
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD1) = 111.5 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 14
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.222 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.170
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD1) = 62.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.142 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.108
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD1) = 78.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.171 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 15
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD1) = 96.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.215
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD1) = 111.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.238
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD1) = 62.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD1) = 78.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 16
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.183
PASS - Design shear capacity exceeds ultimate shear load
Combination 2 results: 1.2D + 1.6L + 0.5Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 54.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.131
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 37.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.096
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 17
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along x axis, left side


Ultimate shear force at face of column; Vu = 150.4 kN
Ultimate moment force at face of column; Mu = 53.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.362
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 185.2 kN
Ultimate moment force at face of column; Mu = 54.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 833.8 kN
Design shear capacity; Vn = v  Vn = 625.3 kN
Vu / Vn = 0.296
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 131.6 kN
Ultimate moment force at face of column; Mu = 37.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 797.0 kN
Design shear capacity; Vn = v  Vn = 597.7 kN
Vu / Vn = 0.220
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 209.2 kN
Ultimate moment force at face of column; Mu = 37.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 18
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2156.7 kN
Design shear capacity; Vn = v  Vn = 1617.5 kN
Vu / Vn = 0.129
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD2,Pp2,LRFD2,Pp3,LRFD2,Pp4,LRFD2) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 350.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.418 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.319
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD2,Pp2,LRFD2,Pp3,LRFD2,Pp4,LRFD2) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 328.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.514 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.428
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 19
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD2) = 104.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.217 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.165
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD2) = 120.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.241 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD2) = 64.6 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 20
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD2) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.179 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD2) = 104.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.232
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD2) = 120.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 21
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.257
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD2) = 64.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD2) = 82.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load

Combination 3 results: 1.2D + 1.6L + 1  0.5S

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 42.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 22
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 29.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 118.0 kN
Ultimate moment force at face of column; Mu = 42.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.284
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 145.1 kN
Ultimate moment force at face of column; Mu = 42.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 23
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 841.0 kN
Design shear capacity; Vn = v  Vn = 630.7 kN
Vu / Vn = 0.230
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 105.7 kN
Ultimate moment force at face of column; Mu = 29.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 799.9 kN
Design shear capacity; Vn = v  Vn = 600.0 kN
Vu / Vn = 0.176
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 162.6 kN
Ultimate moment force at face of column; Mu = 28.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.5 kN
Design shear capacity; Vn = v  Vn = 1633.9 kN
Vu / Vn = 0.100
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD3,Pp2,LRFD3,Pp3,LRFD3,Pp4,LRFD3) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.331 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 24
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa


vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.253
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD3,Pp2,LRFD3,Pp3,LRFD3,Pp4,LRFD3) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 256.2 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.401 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.334
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD3) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.172 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 25
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 2


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD3) = 95.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.190 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.145
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD3) = 53.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.122 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.093
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD3) = 67.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 26
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD3) = 82.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD3) = 95.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.204
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD3) = 53.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD3) = 67.6 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 27
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 4 results: 1.2D + 1.6L + 0.5R
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 42.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 29.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 28
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 118.0 kN
Ultimate moment force at face of column; Mu = 42.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.284
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 145.1 kN
Ultimate moment force at face of column; Mu = 42.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 841.0 kN
Design shear capacity; Vn = v  Vn = 630.7 kN
Vu / Vn = 0.230
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 105.7 kN
Ultimate moment force at face of column; Mu = 29.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 799.9 kN
Design shear capacity; Vn = v  Vn = 600.0 kN
Vu / Vn = 0.176
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 162.6 kN
Ultimate moment force at face of column; Mu = 28.4 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 29
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm


Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.5 kN
Design shear capacity; Vn = v  Vn = 1633.9 kN
Vu / Vn = 0.100
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD4,Pp2,LRFD4,Pp3,LRFD4,Pp4,LRFD4) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.331 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.253
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD4,Pp2,LRFD4,Pp3,LRFD4,Pp4,LRFD4) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 256.2 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.401 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 30
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa


Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.334
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD4) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.172 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD4) = 95.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.190 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.145
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 31
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter width; ly,perim = 708 mm


Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD4) = 53.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.122 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.093
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD4) = 67.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD4) = 82.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 32
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 2


Ultimate shear force; Vu = abs(Pp2,LRFD4) = 95.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.204
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD4) = 53.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD4) = 67.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 5 results: 1.2D + 1.0L + 1.6Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 80.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 33
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278


PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.195
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 56.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.144
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 221.8 kN
Ultimate moment force at face of column; Mu = 78.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.534
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 273.5 kN
Ultimate moment force at face of column; Mu = 80.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 34
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 825.4 kN
Design shear capacity; Vn = v  Vn = 619.0 kN
Vu / Vn = 0.442
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 188.7 kN
Ultimate moment force at face of column; Mu = 53.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 793.3 kN
Design shear capacity; Vn = v  Vn = 595.0 kN
Vu / Vn = 0.317
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 311.8 kN
Ultimate moment force at face of column; Mu = 56.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2131.7 kN
Design shear capacity; Vn = v  Vn = 1598.8 kN
Vu / Vn = 0.195
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD5,Pp2,LRFD5,Pp3,LRFD5,Pp4,LRFD5) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 509.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.609 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 35
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa


vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.465
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD5,Pp2,LRFD5,Pp3,LRFD5,Pp4,LRFD5) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 488.3 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.764 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.636
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD5) = 151.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.315 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.240
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 36
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD5) = 176.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.351 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.268
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD5) = 88.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.202 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.154
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD5) = 115.6 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 37
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.250 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.191
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD5) = 151.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.337
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD5) = 176.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.375
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD5) = 88.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.216
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 38
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 4


Ultimate shear force; Vu = abs(Pp4,LRFD5) = 115.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.268
PASS - Design shear capacity exceeds ultimate shear load
Combination 6 results: 1.2D + 1.0L + 1.6S
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 42.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 29.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 39
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134


PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 118.0 kN
Ultimate moment force at face of column; Mu = 42.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.284
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 145.1 kN
Ultimate moment force at face of column; Mu = 42.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 841.0 kN
Design shear capacity; Vn = v  Vn = 630.7 kN
Vu / Vn = 0.230
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 105.7 kN
Ultimate moment force at face of column; Mu = 29.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 799.9 kN
Design shear capacity; Vn = v  Vn = 600.0 kN
Vu / Vn = 0.176
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 40
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, bottom side


Ultimate shear force at face of column; Vu = 162.6 kN
Ultimate moment force at face of column; Mu = 28.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.5 kN
Design shear capacity; Vn = v  Vn = 1633.9 kN
Vu / Vn = 0.100
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD6,Pp2,LRFD6,Pp3,LRFD6,Pp4,LRFD6) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.331 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.253
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD6,Pp2,LRFD6,Pp3,LRFD6,Pp4,LRFD6) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 256.2 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.401 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 41
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.334
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD6) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.172 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD6) = 95.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.190 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.145
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 42
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 3


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD6) = 53.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.122 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.093
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD6) = 67.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD6) = 82.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 43
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 448.9 kN


Vu / Vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD6) = 95.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.204
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD6) = 53.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD6) = 67.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 7 results: 1.2D + 1.0L + 1.6R
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 42.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 44
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm


Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 29.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 118.0 kN
Ultimate moment force at face of column; Mu = 42.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.284
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 145.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 45
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 42.4 kNm


Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 841.0 kN
Design shear capacity; Vn = v  Vn = 630.7 kN
Vu / Vn = 0.230
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 105.7 kN
Ultimate moment force at face of column; Mu = 29.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 799.9 kN
Design shear capacity; Vn = v  Vn = 600.0 kN
Vu / Vn = 0.176
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 162.6 kN
Ultimate moment force at face of column; Mu = 28.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.5 kN
Design shear capacity; Vn = v  Vn = 1633.9 kN
Vu / Vn = 0.100
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD7,Pp2,LRFD7,Pp3,LRFD7,Pp4,LRFD7) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.331 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 46
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50


Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.253
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD7,Pp2,LRFD7,Pp3,LRFD7,Pp4,LRFD7) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 256.2 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.401 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.334
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD7) = 82.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.172 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 47
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa


Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD7) = 95.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.190 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.145
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD7) = 53.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.122 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.093
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 48
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter width; ly,perim = 666 mm


Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD7) = 67.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD7) = 82.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD7) = 95.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.204
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD7) = 53.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 49
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD7) = 67.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 8 results: 1.2D + 1.6Lr + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 99.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.241
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 69.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 50
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to neutral axis; c = a / 1 = 39 mm


Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.178
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 195.5 kN
Ultimate moment force at face of column; Mu = 67.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.471
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 336.0 kN
Ultimate moment force at face of column; Mu = 99.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 818.5 kN
Design shear capacity; Vn = v  Vn = 613.9 kN
Vu / Vn = 0.547
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 149.2 kN
Ultimate moment force at face of column; Mu = 43.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 758.2 kN
Design shear capacity; Vn = v  Vn = 568.7 kN
Vu / Vn = 0.262
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 51
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 387.6 kN
Ultimate moment force at face of column; Mu = 69.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2140.7 kN
Design shear capacity; Vn = v  Vn = 1605.5 kN
Vu / Vn = 0.241
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD8,Pp2,LRFD8,Pp3,LRFD8,Pp4,LRFD8) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 545.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.652 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.498
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD8,Pp2,LRFD8,Pp3,LRFD8,Pp4,LRFD8) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 524.6 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 52
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.821 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.683
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD8) = 167.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.349 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.267
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD8) = 235.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.469 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.358
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 53
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD8) = 45.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.104 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD8) = 118.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.257 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.197
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD8) = 167.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 54
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.374
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD8) = 235.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.501
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD8) = 45.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD8) = 118.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.276
PASS - Design shear capacity exceeds ultimate shear load
Combination 9 results: 1.2D + 1.6S + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 61.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 55
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm


Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.148
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 41.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.107
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 91.8 kN
Ultimate moment force at face of column; Mu = 30.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 582.5 kN
Design shear capacity; Vn = v  Vn = 436.9 kN
Vu / Vn = 0.210
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 56
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along x axis, right side


Ultimate shear force at face of column; Vu = 207.6 kN
Ultimate moment force at face of column; Mu = 61.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 825.1 kN
Design shear capacity; Vn = v  Vn = 618.8 kN
Vu / Vn = 0.335
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 66.1 kN
Ultimate moment force at face of column; Mu = 19.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 725.0 kN
Design shear capacity; Vn = v  Vn = 543.7 kN
Vu / Vn = 0.122
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 238.4 kN
Ultimate moment force at face of column; Mu = 41.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.2 kN
Design shear capacity; Vn = v  Vn = 1633.7 kN
Vu / Vn = 0.146
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 57
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Sum(Pp1,LRFD9,Pp2,LRFD9,Pp3,LRFD9,Pp4,LRFD9) - 1.2  (conc  Dcap) 


(Acap - AInsidePerim)) = 313.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.375 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.286
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD9,Pp2,LRFD9,Pp3,LRFD9,Pp4,LRFD9) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 292.5 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.458 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.381
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD9) = 99.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.206 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 58
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa


vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.158
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD9) = 154.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.309 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.236
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD9) = 10.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.025 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.019
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 59
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 4


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD9) = 70.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.154 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.117
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD9) = 99.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.221
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD9) = 154.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.330
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD9) = 10.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 60
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.026
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD9) = 70.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.164
PASS - Design shear capacity exceeds ultimate shear load
Combination 10 results: 1.2D + 1.6R + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 61.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.148
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 41.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 61
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm


Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.107
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 91.8 kN
Ultimate moment force at face of column; Mu = 30.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 582.5 kN
Design shear capacity; Vn = v  Vn = 436.9 kN
Vu / Vn = 0.210
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 207.6 kN
Ultimate moment force at face of column; Mu = 61.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 825.1 kN
Design shear capacity; Vn = v  Vn = 618.8 kN
Vu / Vn = 0.335
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 66.1 kN
Ultimate moment force at face of column; Mu = 19.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 62
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 725.0 kN
Design shear capacity; Vn = v  Vn = 543.7 kN
Vu / Vn = 0.122
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 238.4 kN
Ultimate moment force at face of column; Mu = 41.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.2 kN
Design shear capacity; Vn = v  Vn = 1633.7 kN
Vu / Vn = 0.146
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD10,Pp2,LRFD10,Pp3,LRFD10,Pp4,LRFD10) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 313.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.375 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.286
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 63
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter width; ly,perim = 600 mm


Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD10,Pp2,LRFD10,Pp3,LRFD10,Pp4,LRFD10) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 292.5 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.458 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.381
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD10) = 99.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.206 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.158
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD10) = 154.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.309 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 64
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa


Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.236
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD10) = 10.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.025 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.019
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD10) = 70.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.154 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.117
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 65
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 1


Ultimate shear force; Vu = abs(Pp1,LRFD10) = 99.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.221
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD10) = 154.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.330
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD10) = 10.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.026
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD10) = 70.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.164
PASS - Design shear capacity exceeds ultimate shear load
Combination 11 results: 1.2D + 1.0L + 0.5Lr + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 92.3 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 66
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)


Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.223
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 63.5 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.163
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 98.0 kN
Ultimate moment force at face of column; Mu = 30.1 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 67
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 683.8 kN
Design shear capacity; Vn = v  Vn = 512.8 kN
Vu / Vn = 0.191
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 310.2 kN
Ultimate moment force at face of column; Mu = 92.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 815.5 kN
Design shear capacity; Vn = v  Vn = 611.6 kN
Vu / Vn = 0.507
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 52.5 kN
Ultimate moment force at face of column; Mu = 16.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 617.9 kN
Design shear capacity; Vn = v  Vn = 463.4 kN
Vu / Vn = 0.113
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 360.9 kN
Ultimate moment force at face of column; Mu = 63.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2165.5 kN
Design shear capacity; Vn = v  Vn = 1624.1 kN
Vu / Vn = 0.222
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 68
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column two way shear design


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD11,Pp2,LRFD11,Pp3,LRFD11,Pp4,LRFD11) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 422.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.505 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.385
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD11,Pp2,LRFD11,Pp3,LRFD11,Pp4,LRFD11) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 401.3 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.628 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.523
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 69
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Pp1,LRFD11) = 137.1 kN


Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.286 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.218
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD11) = 239.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.477 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.364
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD11) = 21.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.048 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 70
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa


Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.036
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD11) = 89.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.193 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.147
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD11) = 137.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.305
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD11) = 239.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.510
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 71
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD11) = 21.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.051
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD11) = 89.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.207
PASS - Design shear capacity exceeds ultimate shear load

Combination 12 results: 1.2D + 1.0L + 1  0.5S + 1.0W

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 80.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.194
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 72
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, positive moment


Ultimate bending moment; Mu = 54.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.141
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 65.6 kN
Ultimate moment force at face of column; Mu = 18.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 777.9 kN
Design shear capacity; Vn = v  Vn = 583.4 kN
Vu / Vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 270.1 kN
Ultimate moment force at face of column; Mu = 80.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 816.6 kN
Design shear capacity; Vn = v  Vn = 612.4 kN
Vu / Vn = 0.441
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 73
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 26.6 kN
Ultimate moment force at face of column; Mu = 9.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 617.9 kN
Design shear capacity; Vn = v  Vn = 463.4 kN
Vu / Vn = 0.057
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 314.3 kN
Ultimate moment force at face of column; Mu = 54.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.1 kN
Design shear capacity; Vn = v  Vn = 1633.6 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD12,Pp2,LRFD12,Pp3,LRFD12,Pp4,LRFD12) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 350.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.418 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.319
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 74
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD12,Pp2,LRFD12,Pp3,LRFD12,Pp4,LRFD12) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 328.8 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.515 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.428
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD12) = 115.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.241 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD12) = 214.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 75
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.427 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.326
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD12) = 31.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.073 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD12) = 74.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.161 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 76
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.123
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD12) = 115.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.258
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD12) = 214.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.456
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD12) = 31.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.078
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD12) = 74.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 77
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Combination 13 results: 1.2D + 1.0L + 0.5R + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 80.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.194
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 54.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.141
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 78
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along x axis, left side


Ultimate shear force at face of column; Vu = 65.6 kN
Ultimate moment force at face of column; Mu = 18.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 777.9 kN
Design shear capacity; Vn = v  Vn = 583.4 kN
Vu / Vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 270.1 kN
Ultimate moment force at face of column; Mu = 80.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 816.6 kN
Design shear capacity; Vn = v  Vn = 612.4 kN
Vu / Vn = 0.441
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 26.6 kN
Ultimate moment force at face of column; Mu = 9.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 617.9 kN
Design shear capacity; Vn = v  Vn = 463.4 kN
Vu / Vn = 0.057
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 314.3 kN
Ultimate moment force at face of column; Mu = 54.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 79
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.1 kN
Design shear capacity; Vn = v  Vn = 1633.6 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 350.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.418 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.319
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 328.8 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.515 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.428
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 80
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD13) = 115.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.241 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.184
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD13) = 214.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.427 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.326
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD13) = 31.9 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 81
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.073 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.055
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD13) = 74.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.161 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.123
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD13) = 115.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.258
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD13) = 214.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 82
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.456
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD13) = 31.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.078
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD13) = 74.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load

Combination 14 results: (1.2 + 0.2  SDS)D + 1.0L + 1  0.2S + 1.0E

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 132.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 83
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.320
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 77.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.198
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 62.5 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.115
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 84
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, negative moment


Ultimate bending moment; Mu = 35.8 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top - y.top / 2 = 422 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02911
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 578.5 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 520.6 kNm
Mu / Mn = 0.069
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 140.9 kN
Ultimate moment force at face of column; Mu = 62.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.339
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 442.2 kN
Ultimate moment force at face of column; Mu = 132.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 806.8 kN
Design shear capacity; Vn = v  Vn = 605.1 kN
Vu / Vn = 0.731
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 85
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 148.4 kN
Ultimate moment force at face of column; Mu = 35.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1012.3 kN
Design shear capacity; Vn = v  Vn = 759.2 kN
Vu / Vn = 0.196
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 455.4 kN
Ultimate moment force at face of column; Mu = 77.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2227.3 kN
Design shear capacity; Vn = v  Vn = 1670.5 kN
Vu / Vn = 0.273
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD14,Pp2,LRFD14,Pp3,LRFD14,Pp4,LRFD14) - 1.321  (conc 
Dcap)  (Acap - AInsidePerim)) = 317.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.379 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.289
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 86
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD14,Pp2,LRFD14,Pp3,LRFD14,Pp4,LRFD14) - 1.321  (conc 
Dcap)  (Acap - AInsidePerim)) = 293.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.460 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.383
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD14) = 95.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.199 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD14) = 376.8 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 87
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.751 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.573
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD14) = 216.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.492 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.376
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD14) = 85.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.185 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 88
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.141
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD14) = 95.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.213
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD14) = 376.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.803
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD14) = 216.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.528
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD14) = 85.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 89
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.198
PASS - Design shear capacity exceeds ultimate shear load
Combination 15 results: 0.9D + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 69.7 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.168
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 47.7 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.123
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 90
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along x axis, left side


Ultimate shear force at face of column; Vu = 36.1 kN
Ultimate moment force at face of column; Mu = 8.2 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1036.0 kN
Design shear capacity; Vn = v  Vn = 777.0 kN
Vu / Vn = 0.046
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 233.8 kN
Ultimate moment force at face of column; Mu = 69.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 812.8 kN
Design shear capacity; Vn = v  Vn = 609.6 kN
Vu / Vn = 0.384
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 0.2 kN
Ultimate moment force at face of column; Mu = 2.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 617.9 kN
Design shear capacity; Vn = v  Vn = 463.4 kN
Vu / Vn = 0.000
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 273.6 kN
Ultimate moment force at face of column; Mu = 47.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 91
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2178.0 kN
Design shear capacity; Vn = v  Vn = 1633.5 kN
Vu / Vn = 0.167
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD15,Pp2,LRFD15,Pp3,LRFD15,Pp4,LRFD15) - 0.9  (conc  Dcap) 
(Acap - AInsidePerim)) = 280.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.335 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.256
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD15,Pp2,LRFD15,Pp3,LRFD15,Pp4,LRFD15) - 0.9  (conc  Dcap) 
(Acap - AInsidePerim)) = 264.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.414 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.345
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 92
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD15) = 95.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.198 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.151
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD15) = 190.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.379 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.289
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD15) = 45.3 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 93
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.103 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.079
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD15) = 57.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.124 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.095
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD15) = 95.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.212
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD15) = 190.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 94
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.405
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD15) = 45.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.110
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD15) = 57.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Vu / Vn = 0.133
PASS - Design shear capacity exceeds ultimate shear load

Combination 16 results: (0.9 - 0.2  SDS)D + 1.0E

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 113.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 95
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.274
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 64.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.165
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 81.5 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.150
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 96
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, negative moment


Ultimate bending moment; Mu = 49.3 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top - y.top / 2 = 422 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02911
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 578.5 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 520.6 kNm
Mu / Mn = 0.095
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 194.2 kN
Ultimate moment force at face of column; Mu = 81.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 250 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 553.6 kN
Design shear capacity; Vn = v  Vn = 415.2 kN
Vu / Vn = 0.468
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 376.7 kN
Ultimate moment force at face of column; Mu = 113.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 214 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 800.9 kN
Design shear capacity; Vn = v  Vn = 600.7 kN
Vu / Vn = 0.627
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 97
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 196.2 kN
Ultimate moment force at face of column; Mu = 49.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 184 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 960.0 kN
Design shear capacity; Vn = v  Vn = 720.0 kN
Vu / Vn = 0.272
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 382.0 kN
Ultimate moment force at face of column; Mu = 64.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 88 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2236.8 kN
Design shear capacity; Vn = v  Vn = 1677.6 kN
Vu / Vn = 0.228
PASS - Design shear capacity exceeds ultimate shear load
Column two way shear design
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 1260 mm
Shear perimeter width; ly,perim = 1360 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 2620 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1712945.063 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD16,Pp2,LRFD16,Pp3,LRFD16,Pp4,LRFD16) - 0.779  (conc 
Dcap)  (Acap - AInsidePerim)) = 191.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.229 MPa
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.50
Column location factor (11.11.2.1); s =20
Concrete shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.099 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.950 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.175
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 98
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design shear capacity exceeds ultimate shear load


Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 214 mm
Distance to closest pile, y direction; wy = 88 mm
Shear perimeter length; lx,perim = 400 mm
Shear perimeter width; ly,perim = 600 mm
Shear perimeter, modified (CRSI 5.3); bs = 2  (lx,col) + 2  (ly,col) = 2000 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 240000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD16,Pp2,LRFD16,Pp3,LRFD16,Pp4,LRFD16) - 0.779  (conc 
Dcap)  (Acap - AInsidePerim)) = 178.0 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.279 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 1.602 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 1.602 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 1.201 MPa
vumod / vn = 0.232
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 742 mm
Shear perimeter width; ly,perim = 761 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1503 mm
Ultimate shear load; Vu = abs(Pp1,LRFD16) = 58.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.122 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.746 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.093
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 766 mm
Shear perimeter width; ly,perim = 805 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1571 mm
Ultimate shear load; Vu = abs(Pp2,LRFD16) = 333.7 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 99
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.665 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.665 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.508
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 669 mm
Shear perimeter width; ly,perim = 708 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1377 mm
Ultimate shear load; Vu = abs(Pp3,LRFD16) = 240.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.547 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.916 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.418
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 778 mm
Shear perimeter width; ly,perim = 666 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1444 mm
Ultimate shear load; Vu = abs(Pp4,LRFD16) = 54.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.119 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.822 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 100
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.091
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD16) = 58.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2082 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 598.5 kN
Design shear capacity; Vn = v  Vn = 448.9 kN
Vu / Vn = 0.130
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD16) = 333.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2178 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 626.1 kN
Design shear capacity; Vn = v  Vn = 469.5 kN
Vu / Vn = 0.711
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD16) = 240.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1905 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 547.5 kN
Design shear capacity; Vn = v  Vn = 410.6 kN
Vu / Vn = 0.587
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD16) = 54.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1999 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 574.7 kN
Design shear capacity; Vn = v  Vn = 431.0 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid C/4 101
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.127
PASS - Design shear capacity exceeds ultimate shear load

(12) 19 mm  top bars (152 mm c/c)

(12) 19 mm  bot bars (152 mm c/c)

(12) 19 mm  bot bars (152 mm c/c)


(12) 19 mm  top bars (152 mm c/c)
1800 mm

1800 mm

;
;