F1618 SPC Alarms

Serial pulse coder alarms 350 and 351 can indicate a faulty serial pulse coder or cable. Alarm 350 means the pulse coder for the specified axis has a fault, and diagnosis displays 202 and 204 provide more details. Alarm 351 means a communication error between the pulse coder and specified axis, and diagnosis display 203 provides more details, including potential data transmission errors.

Uploaded by

Shin Dong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
347 views

F1618 SPC Alarms

Serial pulse coder alarms 350 and 351 can indicate a faulty serial pulse coder or cable. Alarm 350 means the pulse coder for the specified axis has a fault, and diagnosis displays 202 and 204 provide more details. Alarm 351 means a communication error between the pulse coder and specified axis, and diagnosis display 203 provides more details, including potential data transmission errors.

Uploaded by

Shin Dong
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

B–62755EN/01 APPENDIX B.

ALARM LIST

(4) Serial pulse coder When either of the following alarms is issued, a possible cause is a faulty
(SPC) alarms serial pulse coder or cable.

Number Message Contents

350 SPC ALARM: n AXIS PULSE COD- The n axis (axis 1–8) pulse coder has a fault. Refer to diagnosis display
ER No. 202 and No. 204 for details.
351 SPC ALARM: n AXIS COMMUNICA- n axis (axis 1–8) serial pulse coder communication error (data transmis-
TION sion fault)
Refer to diagnosis display No. 203 for details.

D The details of serial


pulse coder alarm
No.350
#7 #6 #5 #4 #3 #2 #1 #0
202 CSA BLA PHA PCA BZA CKA SPH

#6 (CSA) : Check sum alarm has occurred.


#5 (BLA) : Battery low alarm has occurred.
#4 (PHA) : Phase data trouble alarm has occurred.
#3 (PCA) : Speed count trouble alarm has occurred.
#2 (BZA) : Battery zero alarm has occurred.
#1 (CKA) : Clock alarm has occurred.
#0 (SPH) : Soft phase data trouble alarm has occurred.
D The details of serial
pulse coder alarm
No.351
#7 #6 #5 #4 #3 #2 #1 #0
203 DTE CRC STB

#7 (DTE) : Data error has occurred.


#6 (CRC) : CRC error has occurred.
#5 (STB) : Stop bit error has occurred.