R70a Compressor
R70a Compressor
WARNING
THIS MANUAL CONTAINS IMPORTANT SAFETY INFORMATION AND SHOULD ALWAYS BE
AVAILABLE TO THOSE PERSONNEL OPERATING THIS UNIT.
READ, UNDERSTAND AND RETAIN ALL INSTRUCTIONS BEFORE OPERATING THIS
EQUIPMENT TO PREVENT INJURY OR EQUIPMENT DAMAGE.
C324-A C469-A
(Ref. Drawing) (Ref. Drawing)
Your authorized Champion Compressor distributor offers all the backup you’ll need. A worldwide network
of authorized distributors provides the finest product support in the air compressor industry.
Your authorized distributor can support your Champion air compressor with these services:
1. Trained parts specialists to assist you in selecting the correct replacement parts.
2. A full line of factory tested CHAMPLUB™ compressor lubricants specifically formulated for use in
Champion compressors.
3. Repair and maintenance kits designed with the necessary parts to simplify servicing your
compressor.
Authorized distributor service technicians are factory trained and skilled in compressor maintenance and
repair. They are ready to respond and assist you by providing fast, expert maintenance and repair
services.
For the location of your local authorized Champion Air Compressor distributor, refer to the yellow
pages of your phone directory or contact:
Factory:
Champion
1301 North Euclid Avenue
Princeton, IL 61356
Phone: (815) 875-3321
Fax: (815) 872-0421
E-Mail: [email protected]
When ordering parts, specify Compressor MODEL, HORSEPOWER and SERIAL NUMBER (see
nameplate on unit). All orders for Parts should be placed with the nearest authorized distributor.
Order by part number and description. Reference numbers are for your convenience only.
2
TABLE OF CONTENTS
_______________________________________________________
Subject Page
Introduction ........................................................................................................................................... 6
Warranty................................................................................................................................................ 6
Operation............................................................................................................................................. 11
3
SAFETY AND OPERATION PRECAUTIONS
___________________________________________________________________________________
Because an air compressor is a piece of machinery with moving and rotating parts, the same precautions
should be observed as with any piece of machinery of this type where carelessness in operation or
maintenance is hazardous to personnel. In addition to the many obvious safety rules that should be
followed with this type of machinery, the additional safety precautions as listed below must be observed:
The user of any air compressor package manufactured by Champion is hereby warned that failure to
follow the preceding Safety and Operation Precautions can result in injuries or equipment damage.
However, Champion does not state as fact or does not mean to imply that the preceding list of Safety and
Operating Precautions is all inclusive, and further that the observance of this list will prevent all injuries or
equipment damage.
4
EXPLANATION OF SAFETY INSTRUCTION SYMBOLS AND DECALS
DANGER
Indicates immediate hazards which will result in severe injury or death.
WARNING
Indicates hazards or unsafe practice which could result in severe injury or death.
CAUTION
Indicates hazards or unsafe practice which could result in damage to the Champion
compressor or minor injury.
NOTICE
Notice is used to notify people of installation, operation or maintenance information which is
important but not hazard-related.
DANGER
This reciprocating compressor must not be used for breathing air. To do so will cause serious
injury whether air is supplied direct from the compressor source or to breathing tanks for later
use. Any and all liabilities for damage or loss due to injury, death and/or property damage
including consequential damages stemming from the use of this compressor to supply
breathing air, will be disclaimed by the manufacturer.
WARNING
The use of this compressor as a booster pump and/or to compress a medium other than
atmospheric air is strictly non-approved and can result in equipment damage and/or injury.
CAUTION
This unit may be equipped with special options which may not be included in this manual. User
must read, understand and retain all information sent with special options.
5
INTRODUCTION
______________________________________________________________________
Champion R Series compressors are the result of advanced engineering and skilled manufacturing. To
be assured of receiving maximum service from this machine the owner must exercise care in its operation
and maintenance. This book is written to give the operator and maintenance department essential
information for day-to-day operation, maintenance and adjustment. Careful adherence to these
instructions will result in economical operation and minimum downtime.
WARRANTY
Champion Five Year Warranty
"R" Series Compressors
CHAMPION warrants each new compressor pump manufactured by CHAMPION, mounted on a factory
assembled unit, to be free from defects in material and workmanship under normal use and service for a
period of sixty (60) months from date of installation or sixty-six (66) months from date of shipment by
CHAMPION or CHAMPION distributor, whichever may occur first. Applies to the compressor pump
only, excluding head valves. Valves, controls and accessories are warranted for the first year only.
Compressor pumps purchased separately would carry a one year warranty.
This five year extended warranty will be prorated over the 5 years as follows:
First Year - 100% Allowance, Parts and Labor
Second Year - 90% Allowance, Parts and Labor
Third Year - 80% Allowance, Parts and Labor
Fourth Year - 70% Allowance, Parts and Labor
Fifth Year - 60% Allowance, Parts and Labor
Applies to CHAMPION logo, tank or base mounted complete compressors only.
Express Limited Warranty
CHAMPION warrants each new air compressor unit manufactured by CHAMPION to be free from defects
in material and workmanship under normal use and service for a period of twelve (12) months from date of
installation or eighteen (18) months from date of shipment by CHAMPION or CHAMPION distributor,
whichever may occur first.
6
TWO STAGE AIR COMPRESSORS - MODEL R70A
DIMENSIONS
ITEM PL70A
A Base-Width 12-7/8”
B Bolt Down-Width 5-11/16”
(from center line)
C Bolt Down to Edge 3/4”
D Base to Crank Ctr 8-3/16”
E Overall Width 33”
F Overall Height 33-9/16”
H HP Exhaust Opening 1-1/4NPT
I Bolt Down Hole Dia. 9/16”
J Base-Depth 13-1/4”
K Bolt Down Depth 11-1/4”
L Bolt Down to Edge 1”
M Bolt Hole to Wheel (Max.) 5-3/4”
N Flywheel Width 3-1/2”
O Crank Diameter 2-1/4”
P Flywheel Diameter 22”
C-325-A Q Flywheel Grooves 3VB
(Ref. Drawing) R Overall Depth 27-1/4”
NOTE:
Flywheel Rotation – Clockwise when viewed
from front, flywheel to rear.
SPECIFICATIONS
MODEL BORE & STROKE NO. of OIL WEIGHT MAXIMUM CU MIN./MAX.
(INCH) CYLINDERS CAPACITY (LBS) PRESSURE FT./REV. RPM.
(QTS) (PSIG)
R70A 6-1/4" & 3-1/4" x 4" 4 6-1/3 450 175 .142 425/1000
PERFORMANCE
OUTPUT COOLING HEAT APPROX.
PRESS. MOTOR PUMP DISPL. AIR FLOW REJECTION PULLEY O.D.,
PUMP PSIG H.P. RPM CFM CFM BTU/HR INCHES
R70A 125 20 770 109.4 2580 44,700 8.95
R70A 125 25 890 127.8 2980 55,970 11.4
R70A 175 20 665 93.0 2195 44,700 8.35
R70A 175 25 770 109.4 2580 55,970 9.75
R70A 175 30 890 127.8 2980 67,160 11.4
7
INSTALLATION
WARNING
Do not operate unit if damaged during shipping, handling or use. Operating unit if damaged
may result in injury.
1. Permanently installed compressors must be located in a clean, well ventilated dry room so
compressor receives adequate supply of fresh, clean, cool and dry air. It is recommended that a
compressor, used for painting, be located in a separate room from that area wherein body sanding
and painting is done. Abrasive particles or paint, found to have clogged the air intake filters and
intake valves, shall automatically void warranty.
2. Compressors should never be located so close to a wall or other obstruction that flow of air
through the fan blade flywheel, which cools the compressor, is impeded. Permanently mounted
units should have flywheel at least 12" from wall.
3. Place stationary compressors on firm level ground or flooring. Permanent installations require
bolting to floor. Bolt holes in tank or base feet are provided. Before bolting or lagging down, shim
compressor level. Avoid putting a stress on a tank foot by pulling it down to floor. This will only
result in abnormal vibration, and possible cracking of air receiver. It is recommended that unit be
set on optional vibro-isolator pads. Tanks bolted directly to a concrete floor without isolators will
not be warranted against cracking. Champion vibro-isolators or approved equivalent must be
installed for extended warranty to apply to ASME receivers.
4. If installing a bare pump, or base mounted unit, make certain the pressure limiting controls are
properly installed and operational. A pressure switch must be provided by customer for start/stop
operation. If a pilot valve is used the compressor must be equipped with head unloaders.
5. A properly sized air check valve must be installed in the discharge piping between the compressor
outlet and the inlet of any receiver tank(s) in the system.
DANGER
Do not install isolating valves between compressor outlet and air receiver. This will cause excessive
pressure if valve is closed and cause injury and equipment damage.
WARNING
Always use an air pressure regulating device at the point of use. Failure to do so can result in injury or
equipment damage.
CAUTION
• Do not install in an area where ambient temperature is below 32 degrees F or above
100 degrees F.
• Do not install unit in an area where air is dirty and/or chemical laden.
• Unit is not to be installed outdoors.
8
INSTALLATION (CONT’D)
It is essential that the power supply and the supply wiring are adequately sized and that the voltage
correspond to the unit specifications. Branch circuit protection must be provided at installation a
specified in the National Electrical Code.
All wiring should be performed by a licensed electrician or electrical contractor. Wiring must meet
applicable codes for area of installation. The table gives recommended wire sizes based on the
1999 NEC.
MOTOR 3 PHASE
HP 200/208V 230V 460V 575V
20 3 (0) 4 (1) 8 (6) 10 (6)
25 1 (000) 2 (00) 6 (4) 8 (6)
30 0 (0000) 1 (000) 6 (3) 8 (4)
Values in ( ) for Duplex Unit w/one incoming power line to both motors.
All models require a properly sized magnetic starter as specified in the National Electric Code (NEC).
See Figure 1-1 for simplex wiring diagram and Figure 1-2 for duplex wiring diagram.
If ordered with a factory mounted magnetic starter, compressor is wired at factory. It is necessary only to
bring lines from a properly sized disconnect switch to the magnetic starter mounted on the unit.
9
ELECTRICAL POWER SUPPLY (CONT’D)
B1258-A
(Ref. Drawing)
Figure 1-2 Duplex Wiring Diagram
CAUTION
Wiring must be such that when viewing compressor from opposite shaft end, rotation of shaft is
clockwise as shown by arrow on guard. Wrong direction rotation for any length of time will result in
damage to compressor.
GROUNDING INSTRUCTIONS
This product should be connected to a grounded, metallic, permanent wiring system, or an
equipment-grounding terminal or lead on the product.
WARNING
Never use plastic pipe or improperly rated metal pipe. Improper piping material can burst and
cause injury or property damage.
10
OPERATION
This compressor has been inspected, thoroughly tested and approved at the factory. For this unit to give
long satisfactory service it must be installed and operated properly.
Simplex units have a pressure switch that senses changes in receiver pressure and automatically starts
and stops the compressor at preset pressure limits. If the receiver pressure falls below the cut-in
pressure setting of the pressure switch the compressor will run until the cut-out pressure setting of the
pressure switch has been reached.
Duplex units have lead and lag pressure switches and an automatic alternating system to evenly
distribute the load between the two compressors. The pressure switches sense changes in receiver
pressure and automatically start and stop the compressor at preset pressure levels. If the receiver
pressure falls below the cut-in pressure setting of the lead pressure switch but remains above the cut-in
pressure setting of the lag pressure switch, only one compressor will run until receiver pressure reaches
the cut-out pressure of the lead pressure switch. The next time the pressure in the receiver drops, the
system automatically starts the compressor that was idle. If the receiver pressure falls below the cut-in
pressure setting of the lag pressure switch, both compressors run until receiver pressure reaches the cut-
out pressure setting of the lead pressure switch.
Units furnished with head unloaders are equipped with a needle valve, pilot valve and head unloaders to
provide continuous run capabilities. The pilot valve acts as an automatic air switch allowing air to flow
from the receiver to the head unloader mechanism, thus actuating it. To operate unit in continuous run,
open needle valve located next to pilot valve. The pilot valve is now able to sense receiver pressure.
When the receiver pressure reaches the cut-out pressure setting of the pilot valve, the pilot valve opens
and air is released to the unloader mechanism. The compressor stops compressing air and runs
unloaded until the cut-in pressure setting of the pilot valve has been reached. At this time air released
from the unloader mechanism and the compressor starts compressing again. Continuous run is
recommended if motor starts exceed 8 starts/hour.
Initial Start Up
1. Inspect unit for any visible signs of damage that would have occurred in shipment or during
installation.
2. Pull main disconnect switch to unit to assure that no power is coming into the unit. “Lock Out” or
“Tag Out” switch. Connect power leads to start.
WARNING
Do not attempt to operate compressor on voltage other than that specified on order or on
compressor motor.
3. Check compressor oil level. Add oil as required. See “Compressor Oil Specifications” Section.
NOTE: Do not mix oil type, weights or brands.
4. Activate main disconnect switch.
5. “Jog” motor and check for proper rotation by direction arrow. If rotation is wrong, reverse input
connections on the magnetic starter.
6. Close receiver outlet hand valve and start.
7. With receiver hand valve closed, let machine pump up to operating pressure. At this stage the
automatic controls will take over. Check for proper cycling operation.
8. Check for proper operation of any options. Refer to individual option instruction sheet.
9. When the initial run period has shown no operating problems, shut unit down and recheck oil level.
10. Open receiver hand valve. The air compressor unit is now ready for use.
WARNING
This unit can start automatically without warning.
11
GUIDE TO MAINTENANCE
For Service contact an authorized Champion distributor. All requests should include model number
and serial number. To obtain reliable and satisfactory service, this unit requires a consistent
preventive maintenance schedule. Maintenance schedule form is included to aid in keeping the
proper records.
WARNING
Before performing any maintenance function, switch main disconnect switch to "off" position
to assure no power is entering unit. "Lock Out" or "Tag Out" all sources of power. Be sure all
air pressure in unit is relieved. Failure to do this may result in injury or equipment damage.
DAILY MAINTENANCE
1. Check oil level of compressor. Add Champlub recip lubricant as required. See “Compressor Oil
Specifications” Section. NOTE: Do not mix oil type, weight, or brands.
2. Drain moisture from tank by opening tank drain cock located in bottom of tank. Do not open drain
valve if tank pressure exceeds 25 PSIG.
3. Turn off compressor at the end of each day's operation. Turn off power supply at wall switch.
WEEKLY MAINTENANCE
1. Clean dust and foreign matter from cylinder head, motor, fan blade, air lines, intercooler and tank.
WARNING
Do not exceed 15 PSIG nozzle pressure when cleaning element parts with compressed air. Do
not direct compressed air against human skin. Serious injury could result. Never wash
elements in fuel oil, gasoline or flammable solvent.
3. Check V-belts for tightness. The V-belts must be tight enough to transmit the necessary power to
the compressor. Adjust the V-belts as follows:
b. Loosen mounting hardware which secures motor to base. Slide motor within slots of baseplate to
desired position.
c. Apply pressure with finger to one belt at midpoint span. Tension is correct if top of belt aligns with
bottom of adjacent belt. Make further adjustments if necessary.
WARNING
Never operate unit without belt guard in place. Removal will expose rotating parts which can
cause injury or equipment damage.
12
EVERY 90 DAYS OR 500 HOURS MAINTENANCE
2. Check entire system for air leakage around fittings, connections, and gaskets, using soap solution
and brush.
4. Check and clean compressor valves as required. Replace when worn or damaged parts.
CAUTION
Valves must be replaced in original position. Valve gaskets should be replaced each time
valves are serviced.
PRESSURE RELIEF VALVE: The pressure relief valve is an automatic pop valve. Each valve is properly
adjusted for the maximum pressure of the unit on which it is installed. If it should pop, it will be
necessary to drain all the air out of the tank in order to reseat properly, or drop pressure in line. Do
not readjust.
PRESSURE SWITCH: The pressure switch is automatic and will start compressor at the low pressure
and stop when the maximum pressure is reached. It is adjusted to start and stop compressor at the
proper pressure for the unit on which it is installed. Do not readjust.
BELTS: Drive belts must be kept tight enough to prevent slipping. If belts slip or squeak, see V-belt
maintenance in preceding section.
CAUTION
If belts are too tight, overload will be put on motor and motor bearings.
COMPRESSOR VALVES: If compressor fails to pump air or seems slow in filling up tank, disconnect
unit from power source and remove valves and clean thoroughly, using compressed air and a soft
wire brush. After cleaning exceptional care must be taken that all parts are replaced in exactly the
same position and all joints must be tight or the compressor will not function properly. See
instructions below for manifold assembly. When all valves are replaced and connections tight,
close hand valve at tank outlet for final test. Valve gaskets should be replaced each time valves
are removed from pump.
C374-A
(Ref. Drawing)
13
GENERAL MAINTENANCE (Cont'd.)
CHECK VALVE: The check valve closes when the compressor stops operating, preventing air from
flowing out of the tank through the pressure release valve. After the compressor stops operating, if
air continues to escape through the release valve, it is an indication that the check valve is leaking.
This can be corrected by removing check valve and cleaning disc and seat. If check valve is worn
badly, replace same.
WARNING
Before removing check valve be sure all air is drained out of tank and power is disconnected.
Failure to do so may result in injury or equipment damage.
THE INTERSTAGE PRESSURE RELIEF VALVE is provided to protect against interstage over pressure
and is factory set for maximum pressure of 75 PSIG. DO NOT RESET
If the pressure relief valve pops, it indicates trouble. Shut down the unit immediately and determine
and correct the malfunction. Inspect the head valves. Serious damage can result if not corrected
and can lead to complete destruction of the unit. Tampering with the interstage pressure relief
valve, or plugging the opening destroys the protection provided and voids all warranty.
COMPRESSOR LUBRICATION: Fill crankcase to proper level as indicated by oil sight gauge. Keep
crankcase filled as required by usage. It is recommended that only Champlub recip lubricant be
used. This is a 30-weight, non-detergent industrial oil with rust and oxidation inhibitors specially
formulated for reciprocating compressors. Do not mix oil types, weights or brands.
MOTOR LUBRICATION: Long time satisfactory operation of an electric motor depends in large measure
on proper lubrication of the bearings. Bearing grease will lose its lubricating ability overtime, not
suddenly. Refer to the motor manufacturer’s instructions for the type of grease and lubrication
intervals.
PILOT VALVE: The pilot valve actuates the head unloader mechanism to provide a means of stopping
or starting the compression of air by the compressor without stopping or starting the electric motor.
14
COMPRESSOR PILOT VALVE PRESSURE ADJUSTMENT
Proceed with the following instructions while compressor is running:
1. Loosen locknut (4) and back off several turns. Do not turn differential pressure adjustment nut (3).
2. Check reading on the tank pressure gauge. Set the compressor maximum pressure by turning
threaded cap (1) clockwise to increase pressure or counter clockwise to decrease pressure.
Pressure setting must be 5 psig less than setting of pressure switch.
3. After pressure is set, tighten locknut (4). Be careful not to move threaded cap (1).
2. Check reading on the tank pressure gauge. Set the pressure to 30 psig differential (unload at 170
psig, reload at 140 psig). Turn nut (3) clockwise to increase differential pressure or
counter clockwise to decrease differential pressure.
3. After pressure is set, tighten locknut (2). Be careful not to move nut (3).
B980-B
(Ref. Drawing)
15
COMPRESSOR OIL SPECIFICATIONS
Compressors are factory filled with CHAMPLUB hydrocarbon based recip lubricant. This is an ISO 100
non-detergent industrial lubricant with rust and oxidation inhibitors specially formulated for reciprocating
compressors. It is recommended this compressor be maintained using this oil for ambient temperatures
above 32°F.
CHAMPLUB synthetic is a premium grade diester based synthetic lubricant providing excellent
performance in high temperature applications.
CAUTION
Do not mix oil types, weights or brands.
NOTES:
1. Normal break-in period of Champion air compressors is 25 hours.
2. For the first 100 hours of compressor operation, a careful and regular check of the oil level should be
made. Maintain oil level at the full line.
1. Compressor must run for a 25 hour break-in period using ChampLub ISO 100 oil
2. Thoroughly drain existing oil from crankcase.
3. Fill crankcase with a full charge of synthetic lubricant.
4. Run compressor for 200 hours.
5. Stop compressor and thoroughly drain the synthetic lubricant.
6. Add a full charge of synthetic lubricant.
7. Compressor now ready to run for extended period before next lubricant change.
LUBRICANT
CHAMPLUB
DESCRIPTION PART NUMBER
1 – Quart Case (12/case) P12612A
1 – Gallon Case (4/case) P12613A
5 – Gallon Pail P12614A
55 – Gallon Drum P12615A
CHAMPLUB SYNTHETIC
DESCRIPTION PART NUMBER
1 – Quart Case (12/case) P13179A
1 – Gallon Case (4/case) P13180A
5 – Gallon Pail P11506A
55 – Gallon Drum P13181A
TORQUE VALVES
16
TROUBLE SHOOTING CHART FOR COMPRESSOR
WARNING
Always disconnect unit from power supply and relieve all pressure from air tank before performing
any maintenance. “Tag Out” or “Lock Out” all power sources. Failure to do so may result in
equipment damage or injury.
Never use gasoline or flammable solvent on or around compressor unit. Explosion may result.
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Motor will not start. 1. Main switch and fuses open. 1. Check all fuses and switches. Check
for loose or faulty wires.
2. Starter heater coils open. 2. Check overload relay in starter.
Reset starter.
3. Starter tripped 3. Reset starter. If starter trips
repeatedly, have electrical system
inspected by an electrician.
4. Defective pressure switch- 4. Repair or replace pressure switch.
contacts will not close
Warning – Relieve tank pressure
before servicing.
5. Low voltage. 5. Check with voltmeter. Be sure
voltage corresponds to unit
specifications.
Starter trips repeatedly. 1. Improperly adjusted pressure switch. 1. Adjust or replace.
17
Troubleshooting Chart (cont’d)
Air escapes from centrifugal unloader 1. Check valve stuck in open position. 1. Replace check valve.
when unit is stopped.
18
UNIT REPAIR PARTS ILLUSTRATION
MODELS: HRA20-12, HRA20-25, HRA25-12, HRA25-25, HRA30-12, & HRA30-25
13 (NOTSHOWN)
1 12 (NOT SHOWN)
3
9
7
5
2
6
10
A.S.M.E.
DATA
8 PLATE
11
C466-A
4 (Ref. Drawing)
19
UNIT REPAIR PARTS ILLUSTRATION
MODELS: BRA-20, BRA-25, & BRA-30
6 (NOT SHOWN)
1 5 (NOT SHOWN)
C467-A
(Ref. Drawing)
MODEL
BRA-20 BRA-25 BRA-30
1 Pump R70A R70A R70A
2 Belt Guard Z674 Z674 Z674
3 Base Plate P03538C P03538C P03538C
4 Motor 20 HP 25 HP 30 HP
P05345A P03710A P03710A
Pulley Pulley Pulley
5 Pulley 125 PSIG
P05622A P05621A P05621A
Bushing Bushing Bushing
P05634A P09311B P03710A
Pulley Pulley
5 Pulley 175 PSIG
P05622A P05621A
Bushing Bushing
125 PSIG B100 (3) B103 (3) B103 (3)
6 Belts
175 PSIG B100 (3) B100 (3) B103 (3)
20
UNIT REPAIR PARTS ILLUSTRATION
MODELS: HRA20D-25, HRA25D-25, & HRA30D-25
1
3
5
2
8
10
A.S.M.E.
DATA
15 PLATE
6
14 7
11
C468-A
(Ref. Drawing)
MODEL
HRA20D-25 HRA25D-25 HRA30D-25
1 Pump R70A R70A R70A
2 Pressure Gauge M519C M519C M519C
3 Belt Guard Z674 Z674 Z674
4 Drain Valve M2684 M2684 M2684
5 Check Valve P03590A P03590A P03590A
6 Bucket High Drain Z1542 Z1542 Z1542
125 PSIG P14205A P14205A P14205A
7 Pressure Switch
175 PSIG P14202A P14202A P14202A
8 Pressure Relief Valve M2847 M2487 M2487
9 Motor 20 HP 25 HP 30 HP
10 Tank P12127D P12127D P12127D
11 Isolation Valve M2688 M2688 M2688
P05345A P03710A P03710A
Pulley (2) Pulley (2) Pulley (2)
12 Pulley 125 PSIG P05622A P05621A P05621A
Bushing (2) Bushing (2) Bushing (2)
P05634A P09311B (2) P03710A
Pulley (2) Pulley (2)
12 Pulley 175 PSIG
P05622A P05621A
Bushing (2) Bushing (2)
125 PSIG B100 (6) B103 (6) B103 (6)
13 Belts
175 PSIG B100 (6) B100 (6) B103 (6)
14 Starter Consult Factory
15 Alternator Consult Factory
21
COMPRESSOR REPAIR PARTS ILLUSTRATION
Models: R70A
C308-B
(Ref. Drawing)
22
Repair Parts List
Compressor Model R70A
Ref. Part
Description Qty.
No. Number
1 Crankcase M1386 1
2 Pipe plug M2326 1
3 Oil level gauge RE714 1
4 Pipe nipple M492 1
5 Pipe cap M461 1
6 Pipe plug M459 1
7 Crankshaft M1387 1
8 Main bearing P03431A 1
9 Oil seal P03433A 1
10 Governor housing gasket set Z775 1
11 Governor housing P12274C 1
12 Hex head cap screw M2345 4
13 Hex head cap screw SE594 2
14 Governor housing cover gasket SE1489 1
15 Baffle plate P12381A 1
16 Governor weight spindle SE583B 1
17 Governor weight SE582B 2
18 Governor weight pin SE592A 2
19 Lock washer M3468 1
20 Hex head cap screw M2345 1
21 Flat washer M912A 1
22 Main governor spring SE590 1
23 Governor spring sleeve SE587 1
24 Governor housing cover RE10100A 1
25 Unloader muffler assembly Z4593 1
26 Hex head machine screw M3473 6
27 Release valve kit (includes items 28, 29, 30 & 31) Z12414A 1
28 Release valve plunger SE586B 1
29 Release valve ball P07841A 1
30 Release valve spring SE591 1
31 Release valve cap NR101 1
32 Flywheel P05723C 1
33 Key M1506 1
34 Flywheel washer M1394 1
35 Hex head cap screw M2265 1
36 Low pressure connecting rod assembly (includes 39, 40 & 41) Z621 2
37 High pressure connecting rod assembly (includes 38, 39, 40 & 41) Z622 2
38 Oil dipper (high pressure connecting rod only) P03440A 2
39 Piston pin bearing P03430A 4
40 Connecting rod bolt P03458A 8
41 Connecting rod nut P03459A 8
42 Low pressure piston with pin ZM1906 2
43 Low pressure piston pin M1395 2
44 Piston pin retaining ring P03434A 8
45 Low pressure piston ring set Z9087 2
46 High pressure piston with pin ZM1393 2
47 High pressure piston pin M1383 2
48 High pressure piston ring set Z9088 2
49 Cylinder flange gasket M1391 2
.
23
Repair Parts List
Compressor Model R70A
Ref. Part
Description Qty.
No. Number
50 Cylinder P05863D 2
51 Hex head cap screw M3461 12
52 Low pressure intake valve assembly Z273 2
53 Low pressure valve gasket P07352A 6
54 Low pressure discharge valve assembly Z274 2
55 High pressure discharge valve assembly Z785 2
56 High pressure valve gasket P07353A 8
57 High pressure intake valve assembly Z784 2
*58 Low pressure intake manifold P09711D 2
59 Hex head cap screw P04779A 16
60 Low pressure discharge manifold M1423 2
*61 High pressure intake manifold M1431 2
62 High pressure discharge manifold M1508 2
63 Interstage pressure relief valve M3685 2
64 Intake filter P07447A 2
65 Intake filter element P05051A 2
Complete compressor pump gasket set (items 10, 14 & 49) Z10889 1
Low pressure piston kit (items 42, 43, 44 & 45) Z9108 2
High pressure piston kit (items 44, 46, 47 & 48) Z9107 2
Complete compressor pump ring set (item 45 & 48) Z9123 1
Valve set gasket (items 52, 53, 54, 55, 56 & 57) Z614 1
Valve gasket kit (items 53 & 56) Z615 1
24
COMPRESSOR REPAIR PARTS ILLUSTRATION
Model: R70A
TUBE ASSEMBLIES
C470-A
(Ref. Drawing)
25
CONSTANT SPEED HEAD UNLOADER
FOR AIR COMPRESSOR MODEL R70A
NOTE: This is optional equipment and may not be included on your unit. It is recommended constant speed
unloading be used if motor starts exceed 6 starts/hour.
The purpose of constant speed unloading is to provide a means of stopping or starting the compression of air by the
compressor without stopping or starting the electric motor or gasoline engine after each cycle.
The parts called out below replace or are substituted for those parts found in the regular parts list of the Owner's
Manual for this compressor.
C429-A
(Ref. Drawing)
26
UNIT HAZARD DECAL LISTING
P14677A
27
UNIT HAZARD DECALS
28
PUMP HAZARD DECALS
29
RECORD OF MAINTENANCE SERVICE
DAILY
● CHECK OIL LEVEL
● DRAIN MOISTURE FROM TANK
30
RECORD OF MAINTENANCE SERVICE
DAILY
● CHECK OIL LEVEL
● DRAIN MOISTURE FROM TANK
31
FOR PARTS: REFER TO PARTS DEPOT LIST
ACCOMPANYING THIS MANUAL.
www.championpneumatic.com
Champion
1301 North Euclid Avenue
Princeton, Illinois 61356 USA
Phone (815) 875-3321
Fax (815) 872-0421
E-mail: [email protected]
Copyright 8 2003 Gardner Denver, Inc. Plants in Princeton, IL, and Manteca, CA
Printed in U.S.A. Due to Champion=s continuing product development program,
specifications and materials are subject to change without notice or
32
obligation