3. Analog part:
Non-linearity: ≤0.0015%FS
Load cell Excitation: AC 5V, 250mA, available to connect with 12 load cells of 350Ω or 24
Connecting method of load cell: 6-wire method, and automatic compensation for long wire
4. Display
D18M1 Indicator with single window FSTN 240×64 Dot matrix LCD with high contrast
D18M2 Indicator with double windows 6-bit LED + 128×96 Dot matrix LCD
5. Keyboard
6. Clock: available to indicate year, month, date, hour, minute and second as well
Transmission method: serial output method, 20mA current loop signal (with constant current
source output)
1
XK3190-D18 Technical Parameters
Transmission distance: ≤2000m
Data transmission style: 10-bit binary number, 1 start bit, 8 data bits (ASCII code) and 1 stop bit
9. Printing interface
1) Panel-type microprinter
Printing paper: thermal paper with width of 57mm and roll external diameter less than 40mm
2) Standard parallel printing interface: available to connect with line printers such as ESPON LQ-300K,
Available to store 1000 sets of vehicle number, tare weight, 1000 sets of cargo names, 1000 sets of
DC 6V-8V (optional), Current: ≤0.6A when not printing while ≤3A for printing
●32-bit ARM processor with high speed and high performance, and built-in operating system are adopted to
make real-time and correct accumulation, calculation, memory, inquiry and printing of the weight data;
●Humanized operating interface, two-dimensional rolling menu bar management, quick positioning of required
●Optimized digital filtering feature and good temperature feature, effectively assuring the stability and high
2
XK3190-D18 Technical Parameters
●Complete set functions of measured parameter for general truck weighing indicator;
●Available to store 1000 sets of vehicle number, tare weight, 1000 sets of cargo names, 1000 sets of weighing
●Functions of storage, prompt intelligent inquiry and deletion for weighing records;
●Optional 10M/100M adaptive Ethernet interfaces, available for transmission and management of weighing
●Optional USB data interface, available for connection with computer via USB data wire;
●Optional PS/2 keyboard interface, available for indicator operation via general PS2 keypad of computer.
XK3190-D18m1 Adoption of FSTN 240×64 Dot matrix LCD with high contrast,
XK3190-D18s1 Adoption of FSTN 240×64 Dot matrix LCD with high contrast,
XK3190-D18s1+ Adoption of FSTN 240×64 Dot matrix LCD with high contrast,
XK3190-D18m2 Adoption of 6-bit & 0.8-inch LED display window + 128×96 Dot matrix LCD,
XK3190-D18m2+ Adoption of 6-bit 0.8-inch LED display window + 128×96 Dot matrix LCD,
3
XK3190-D18 Installation and Connection
The signs and characters on the panel should be transparent with black base.
Weight value
3190.00 kg
Automatic Communication Inner code Stability Net weight Zero
Note: The main interface of double-window indicator is similar to that of single-window indicator, and only the layout
5
XK3190-D18 Installation and Connection
▲The connection between load cell and indicator must be reliable and the shield cable must be
well grounded. The connecting line can not be plugged in and out when the indicator is powered
on in order to prevent any damage to the indicator or load cell by static electricity.
▲ The load cell and indicator are both static sensitive equipments, so anti-static measures must
be taken during the use. It is strictly forbidden to carry out welding operation or other
operations with high current on the weighing platform. In the stormy season, lightening
prevention measures must be taken reliably to prevent any damage to load cell and indicator
caused by lightening stroke, and to guarantee the personal security of operators and safe
running of weighing devices and relative equipments.
6
XK3190-D18 Measuring Operation
Chapter 3 Measuring Operation
I. Keyboard Chart
8
XK3190-D18 Measuring Operation
(1) When power-on, the indicator indicates start image and then Inputs weighing status in several seconds
automatically.
(2) When the device is turned on, if the weight deviates from zero but still within the zero parameter scope, the
indicator will automatically return to zero. Please see the Chapter: Menu Operation for the details of parameter
selection and setting method of zero scope upon start,
2. Manual Zero (Semi-automatic Zero)
(1) Push 【Zero】key and the indicator returns to zero. The zero sign is on at this time.
(2) When the indicating value deviates from zero but still within zero scope, the 【Zero】 key is enable, otherwise
it is not. Please see the Chapter: Menu Operation for the details of parameter selection and setting method of
zero scope upon start.
(3) Only when the stability sign is on, the zero operation can be executed.
(4) If the tare weight of the indicator is not zero, first press 【Preset Tare】 key and set the value as 0. Zero setting
can’t be performed until back to the weighing interface.
3. Operation of Tare Function
Three tare methods are provided by the indicator:
(1) General Tare:
In weighing mode, when the indicating weight is positive and stable, press the【Tare】 key, then the indicating
weight will be deducted as tare weight. At this time, the indicator indicates the net weight as 0 with the weight
sign on.
(2) Preset Tare:
Under the gross weight status of weighing interface, press the 【Preset Tare】 key and then the indicator Inputs
interface of Preset Tare. At this time, the indicating tare weight value is the original tare value. If a new tare
value is required to be set, use the number keys to input once again and then press the 【Input】key for
confirmation. Press 【←】 key for back to weighing interface. As for detailed setting method, please see the
Chapter: Menu Operation.
(3) Calling Tare Weight According to VEH No.:
In weighing mode, press the 【VEH No.】 key and the indicator inputs setting interface for VEH No./Tare. After
inputting correct VEH No., press 【Input】 key to call the relative tare weight value of this VEH No. from the
memory. If there is no need to revise the tare weight, press 【Tare】key to take the tare weight value as the
current tare weight and meanwhile return to weighing interface.
4. Measuring Operation for Axle
D18 has the measuring function of axle.
First, set the parameters of “measuring function of axle” to “using measuring of axle” according to the method
described in the chapter “Menu Operation”, and set the “unblocking threshold of axle” to the required value.
After pressing 【Weighing】 key for back to weighing status, the indicator Inputs axle measuring with the sign
of “axle ” on. The steps are as follows:
9
XK3190-D18 Measuring Operation
(1) The first group of axle is moved on the platform for measuring. After it stops, wait until the stability light of the
indicator on. Then press 【Axle】key to lock and record the value;
(2) Remove the first group of axle from the platform and the axle locking is disable. The indicator returns to zero. Then
put the second group of axle on the platform and repeat the operation of Step (1);
(3) After measuring all axles, press 【Axle All】 key. The indicator displays the 【Truck Weight】sign and the whole
car load. Press 【Save Print】 key to save and print the weight. Pres【Weighing】 key to Input new measuring status
of axle again.
10
XK3190-D18 Menu Operation
Chapter 4 Menu Operation
Among XK3190-D18 series, the menu items of double-window indicator are
same as that of single-window indicator, so is the operation method. The only
difference is the layout sequence on the display. The operation of menu items of
single-window indicator is mainly described below.
『Unit』 kg
『A/D Ivert Rate』 50Hz
『Signal Range』 10mV
『Applicate Range』 Not for trade
『Zero Point』 99545
『Calibrate Para.』 『CAL Coefficient』 0.02094
『Nonlinear』 1.00000
『REC Search』 『Record Search』 -
『VEH No. Search』 -
『CGO No. Search』 -
【Check】 『Overload REC』 -
『Scan Record』 -
『Delete All』 -
『Delete Overload』 -
【Set】 FUNC PWD 888888
『Print Method』 Manual Print
『Printer Type』 Microprinter
『Back Zero Limit』 50
『Print Setup』
『Print Format』 3Link Format
『Min. PRT Weight』 0.010
Fill PRT is not
『Fill PRT Option』
applied.
『Comm Method』 Continuous mode
『Comm Setup』 『Comm Address』 1
『Baud Rate』 1200
『USB Setup』 USB function disable
『Net Enable』 Net function disable
『IP Address』 192.168.002.175
『Net Setup』 『Subnet Mask』 255.255.255.000
『MAC Address』 3190
『Default Gateway』 192.168.002.001
Date/Time Setup 『CAL PWD』 888888
12
XK3190-D18 Menu Operation
13
XK3190-D18 Menu Operation
14
XK3190-D18 Menu Operation
When the input area highlighted, it indicates that the value can be input here.
After inputting value in the set area and pushing 【Input】 key, the indicator shall automatically search whether there is
corresponding code in the memory. If so, relative code will be indicated; if not, new code will be formed and indicated.
If user knows the corresponding code of the VAL, he can directly input it in the code area. Then the indicator shall
automatically search the corresponding VAL and indicate it, which will avoid relatively complex operation of input
mode.
If the code is input and there is no corresponding CGO No. searched, the indicator shall indicate “fault”.
Push 【Input】 key for confirmation after input and then push 【←】 key for going back to the weighing interface.
Input Area Input mode Remarks
VAL Number/English/Sign 10 characters can be input at most.
Code Number Three numbers can be input at most.
15
XK3190-D18 Menu Operation
When the input area is highlighted, it indicates that the value can be input here. Either VEH No. or code can be
input.
After inputting value in the VEH No. area and pushing 【Input】 key, the indicator shall automatically search
whether there is corresponding code in the memory. If so, relative code will be indicated; if not, new code will be
formed and indicated. If user knows the corresponding code of the VEH No., he can directly input it in the code area.
Then the indicator shall automatically search the corresponding VEH No. and indicate it, which will avoid relatively
complex operation of input mode.
If the code is input and there is no corresponding VEH No. searched, the indicator will indicate “fault”.
The VEH No. can be input with mixture of English and number. And input mode can be switched by pushing
【Input mode】 key.
After inputting the VEH No. and code, it is switched into tare weight setting automatically. The tare weight column
indicates the corresponding value of the above saved VEH No. If there is no memory, the default tare weight is 0. If the
tare weight value needs to be changed, input directly the new tare weight and push 【Input】 to keep the VAL and then
push 【←】 back to the weighing mode.
16
XK3190-D18 Menu Operation
If the code of VEH No. is 0, it indicates single cargo weighing and tare weight value can not be input.
3. Save Print Setup
Print Information 【123】
VEH: A12345 Code: 1
CGO: --- Code: 1
【←】Back 【Input】 Confirm
Push 【Input】 key,
Print Information 【123】
VEH: A12345 Code: 1
CGO.: --- Code: 1
【←】Back 【Input】 Confirm
Push 【Input】 key,
Print Information 【123】
VEH: A12345 Code: 1
CGO: --- Code: 1
【←】Back 【Input】 Confirm
Push 【Input】 key,
Print Information 【123】
VEH: A12345 Code: 1
CGO.: --- Code: 1
【←】Back 【Input】 Confirm
17
XK3190-D18 Menu Operation
The VEH No. can be input with mixture of English and number. And input mode can be switched by pushing 【Input
mode】 key.
After completion of switch in four input areas, push 【Input】 key to keep the VAL and execute Save Print operation;
if pushing 【←】 key, the print shall be cancelled and return to weighing interface. For the detailed operating rules of
Save Print, please refer to the chapter Printing & Records.
4.『Preset Tare』 Setup
In weighing mode, push 『Preset Tare』 to Input the following interface,
Preset Tare 【123】
VAL: 0.000kg
Input preset tare value
【←】Back 【Input】 Confirm
VAL Remarks
Report by time Print the weighing record periodically and print total three reports in different formats.
Report 1 Print in queque as per the save time of records
Report 2 Print in queque as per VEH No.
Report 3 Print in queque as per CGO No.
Report 4 Print correspondent table between VEH No. and shortcut code.
Report 5 Print correspondent table between CGO No. and shortcut code.
Report 6 Print all Overload RECs.
Push 【↑】【↓】 keys to move the highlighted to select the report type.
18
XK3190-D18 Menu Operation
(1) After choosing 『Report by Time』 and pushing 【Input】, the screen displays:
Report Print 【123】
From: 07 / 12 / 04
To: 07 / 12 / 04
【←】Back 【Input】 Confirm
Input the period of print record, and print all correspondent records of this period after pushing 【Input】 key. Return
to weighing interface after print; push 【←】 key to cancel the print operation, and directly return to the weighing
interface.
(2) When choosing other report type, push 【Input】 key to print it in relative format. After print, it returns to
weighing interface automatically; push 【←】 key to cancel the print operation and directly return to the weighing
interface. See the appendix for the print format of reports.
6. Calibration Setup
First, turn the calibration switch to make it allow for calibration. In weighing mode, push 【Calibration】, the
indicator displays:
CAL PWD 【123】
VAL: ******
Input correct CAL PWD with number keys
【←】Back 【Input】 Confirm
19
XK3190-D18 Menu Operation
20
XK3190-D18 Menu Operation
21
XK3190-D18 Menu Operation
VAL Remarks
kg “kg” unit for indicator display and weighing record.
t “t” unit for indicator display and weighing record.
lb “lb” unit for indicator display and weighing record.
【↓】 keys to select unit and 【Input】 key to save. Push 【←】 key for going back to the previous menu.
Push 【↑】
(8) A/D Convert Rate
Push 【↑】
【↓】 keys to move the optional bar to 『A/D Convert Rate』and then push 【Input】 key to display
the following interface:
VAL Remarks
50Hz A/D convert rate is 50HZ.
100Hz A/D convert rate is 100HZ.
150Hz A/D convert rate is 150HZ.
200Hz A/D convert rate is 200HZ.
Push 【Input】 key to save after input through number keys. Push 【←】 key not to save and return to function menu.
10mV
20mV
【←】Back 【Input】 Confirm
VAL Remarks
10mV The signal source scope of load cell is -10mV~10mV.
20mV The signal source scope of load cell is -20mV~20mV.
Push 【Input】 key to save after input through number keys. Push 【←】 key not to save and return to function
menu.
(10) Applicate Range
Push 【↑】【↓】 keys to move the optional bar to 『Applicate Range』and then push
【Input】 key to display the following interface:
VAL Remarks
Not for Trade Non-law related operations are allowed on non-trade occasions.
For Trade Non-law related operations are invalid for trade.
Push 【Input】 key to save after input through number keys. Push 【←】 key not to save and return to function
menu.
(11) Calibrate Para.
The parameter status after calibration can be examined or revised in this menu. Push 【↑】
【↓】 keys to move the
optional bar to 『Calibrate Para.』and then push 【Input】 key to display the following interface:
Zero 【123】
VAL: 2145
(Input zero AD code)
【←】Back 【Input】 Confirm
23
XK3190-D18 Menu Operation
Input
Input Area Remarks
mode
6 digits can be input at most with the scope between 0.99500~1.00500.
Definition of non-lineary revised value:
Revised value=1 + weight deviation of half F.S. / F.S. value
For example:
VAL Number
When the F.S. value is 30000, but the actual half F.S. is 1505, then
Non-linear revised value=1 + 5/3000=1.00167;
When the F.S. value is 30000, but the actual half F.S. value is 1495, then
Non-linear revised value=1 - 5/3000=0.99833.
In weighing mode, push 【Set】 key and input correct FUNC PWD (888888) to Input menu bar of function
parameter.
Print Setup Date/Time Setup
Comm Setup Date/Time Display
USB Setup CGO Enable
Net Setup 【↑】 Option 【Input】 Confirm
1) Print Method
Push【↑】
【↓】keys to move the optional bar to『Print Method』and then push【Input】key to display the following
interface:
Automatic Print
Manual Print
【←】 Back 【↑】 Option 【Input】 Confirm
25
XK3190-D18 Menu Operation
VAL Remarks
Auto Print Automatically print and save the weighing data during the weighing process.
Manual Print Push 【Save Print】 or 【Fill PRT】 during the weighing process print and save the
weighing data.
Push【↑】
【↓】keys to select relative setup and then push【Input】key. The indicator saves parameters automatically.
Then push 【←】 key for going back to the previous menu. Push 【Weighing】 key to return to weighing interface. In
this instruction, the method for optional parameter setup is same as the above.
2) Printer Type
Push 【↑】【↓】 keys to move the optional bar to 『Printer Type』 and then push 【Input】 key to display the
following interface:
Print Invalid EPSON LQ-1600K
Microprinter
Psonic KX-P1131
EPSON LQ-300K 【↑】 Option 【Input】 Confirm
VAL Remarks
Print Invalid Print function is invalid in this indicator.
Microprinter Built-in micro microprinter is applied.
Psonic KX-P1131 Panasonic KX-P1131 model printer is used.
EPSON LQ-300K EPSON LQ-300K model printer is used.
EPSON LQ-1600K EPSON LQ-1600K model printer is used.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
26
XK3190-D18 Menu Operation
Push 【↑】
【↓】 keys to move the optional bar to 『Option of Print Format』 and then push 【Input】 key to display
the following interface:
Record Format
1 Link format
2 Link draft format
3 Link Format 【↑】 Option 【Input】 Confirm
VAL Remarks
Weighing record is printed according to record format. See the appendix for relative
Record Format
format instruction.
Weighing record is printed according to one link format. See the appendix for relative
1Link Format
format instruction.
Weighing record is printed according to link format. See the appendix for relative
2Link draft Format
format instruction.
Weighing record is printed according to link format. See the appendix for relative
3Link Format
format instruction.
Push 【↑】
【↓】 keys to select relative setup and then push 【Input】 key. The indicator saves parameters automatically.
Input
Input Area Remarks
mode
6 digits can be input at most and the maximum print weight must be not less than 10
divisions.
VAL Number
Every time after completion of calibration, the indicator correct automatically the min. VAL
of min. print weight as per the set scale division value.
After inputting via number keys, push 【Input】 key to save the parameters.
VAL Remarks
Fill PRT not applied Fill PRT mode is not applied in printer. See appendix for relative print modes.
Fill PRT applied Fill PRT mode is applied in printer. See appendix for relative print modes.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
Command Mode
28
XK3190-D18 Menu Operation
Continuous mode
【←】 Back 【↑】 Option 【Input】 Confirm
VAL Remarks
Command mode is adopted for the communication mode between the indicator and upper
Command mode
computer. See the chapter Communication for instruction of relative communication modes.
Continuous mode is adopted for the communication mode between the indicator and upper
Continuous mode
computer. See the chapter Communication for instruction of relative communication modes.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
2) Comm Address
Push 【↑】
【↓】 keys to move the optional bar to 『Comm Address』 and the push 【Input】 key to display the
following interface:
29
XK3190-D18 Menu Operation
After inputting via number keys, push 【Input】 key to save the parameters.
VAL Remarks
USB disable Communication between USB and upper computer is allowed.
USB disable Communication between USB and upper computer is forbidden.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
1) Push 【↑】
【↓】 keys to select 『Net Function』 and then push 【Input】 key,
Net Disable
Net Disable
【←】 Back 【↑】 Option 【Input】 Confirm
VAL Remarks
Net Disable Communication through Ethernet is forbidden for the indicator.
Net Disable Communication through Ethernet is allowed for the indicator.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
2) Push 【↑】
【↓】 keys to select 『IP Address』 and then push 【Input】 key,
30
XK3190-D18 Menu Operation
IP Address 【123】
VAL: 192.168.002.175
(IP ADDR,range:000-255)
【←】 Back 【Input】 Confirmation
3) Push 【↑】
【↓】 keys to select 『Subnet Mask』 and then push 【Input】 key,
Subnet Mask 【123】
VAL: 255.255.255.000
(Subnet Mask,range:000-255)
【←】 Back 【Input】 Confirm
4) Push 【↑】
【↓】 keys to select 『MAC Address』 and then push 【Input】 key,
5) Push 【↑】
【↓】 keys to select 『Default Gateway』 and then push 【Input】 key,
31
XK3190-D18 Menu Operation
After inputting date, push 【Input】 key to save it and then display,
Date/Time Setup 【123】
Date: 06 / 08 / 31
Time: 20 : 16 : 53
【←】 Back 【Input】 Confirm
32
XK3190-D18 Menu Operation
VAL Remarks
Time Display Display the current time under weighing interface
Date Display Display the current date under weighing interface
Neither displayed Neither time nor date is displayed under weighing interface
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
33
XK3190-D18 Menu Operation
VAL Remarks
CGO No. applied Cargo name can be set in the indicator and CGO No. shall be displayed in the print.
CGO No. not Cargo name is forbidden to set in the indicator and CGO No. shall not be displayed in the print.
applied The【CGO No.】 key has no function of setting CGO No. in weighing mode.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
Push 【↑】【↓】 keys to select 『VEH No. Enable』and push 【Input】 key.
VAL Remarks
VEH No. name can be set in the indicator and VEH No. shall be displayed in the print.
VEH No. applied
VEH No. name is forbidden to set in the indicator and VEH No. shall not be displayed
VEH No. not applied in the print.
The 【VEH No.】 key has no function of setting VEH No. in weighing mode.
Push 【↑】
【↓】 keys to select relative set and then push 【Input】 key. The indicator saves parameters automatically.
34
XK3190-D18 Menu Operation
VAL Remarks
Push 【Input】 key after inputting the CAL PWD. If it is correct, then Input the next step. Otherwise, there shall be fault
reported and it needs to be input again. If three mistakes are made, the indicator will return to the previous menu.
Push 【←】 key and the indicator directly return to the previous menu.
VAL Number Input 6-digit for password value and each “*” stands for one number.
36
XK3190-D18 Menu Operation
37
XK3190-D18 Menu Operation
250000
Inner Code Stable
Push 【Weighing】 key and then the indicator is back to the weighing interface.
38
XK3190-D18 Menu Operation
Software
【↑】 Option【Input】 Confirm
1) Micropri Test
Push 【↑】
【↓】 keys to select 【Micropri Test】 and push 【Input】 key. If there is fault for the micro-print, the
indicator displays fault prompt.
2) Software
Push 【↑】
【↓】 keys to select 【Micropri Test】and push 【Input】 key. The indicator displays:
Software
VER 1.00
2008.01.01
【←】 Back
8. Check Record Setup
Under weighing interface, push 【Check】 to Input check record interface.
REC Search Scan Record
VEH. Search All Records DEL
CGO. Search Overload RECs DEL
Overload REC 【↑】 Option 【Input】 Confirm
See the Chapter “Print and Record Processing” for detailed operation.
39
XK3190-D18 Input mode
Chapter 5 Input mode
I. Profile of Input mode
This indicator adopts the input mode with number/English/Sign mixed. The operational way is similar to that of T9
input mode which is popular among mobile phones at present.
For example, if you want to input “?”, push 【Input mode】to switch into sign input status. There shall be a series of
signs displayed in the screen below. Push 【→】 for five times to select “?”, and push 【Input】 key to list the “?”
in the input area. Meanwhile, the input mode is back to Pinyin Input status
41
XK3190-D18 Calibration
Chapter 6 Calibration
I. Calibration setup
First open the lead seal, toggle the calibration switch inside to enable it to allow calibration. In weighing mode,
press 【Calibration】and the indicator will show as follows:
After inputting the valid password, press 【Input】 to Input the calibration setup interface. If password is invalid,
error report will appear to require another input. After three incorrect inputting, the indicator will return to weighing
interface. Press 【←】to directly return to weighing interface.
Calibration setup interface is as follows:
Calibration Manu Zero Set upon Initialization
Zero track speed Filter degree
Zero track range Unit
Manu Zero Set 【↑】Select 【Input】confirm
On the calibration setup interface, press 【↑】【↓】for video reversed bar to select 『Calibration』. Press 【Input】
to Input the setting process interface of calibration.
First appears the division value setting,
Division 【123】
VAL:1
(1,2,5,10,20,50 select)
【←】 Back 【Input】Confirm
After inputting F.S value, press 【Input】 for zero point confirmation
Wait for ad code to stabilize in idling stage under no load statue. Press 【Input】, and the indicator will Input the load
confirmation stage.
VEH. CGO 14:31:48
298568
Calibration AD code Stable Zero point
To load standard weight, wait for AD code to stabilize, then press 【Input】to Input the interface for load value setup
interface (if AD code jumps slightly, it can be considered stabilized)
Loading 【123】
VAL: 3.000 kg
(Input loading value)
【←】Back 【Input】Confirm
43
XK3190-D18 Calibration
Generally speaking, calibration can be completed with the above-mentioned steps. The default values upon delivery
from the factory can be adopted for other measuring parameters. To meet some special requirements, the operating
procedures of the chapter Menu Setup can be followed to do the corresponding setting for the related parameters.
44
XK3190-D18 Communications
Chapter 7 Communication
I. Serial communication interface
Notes:
1. The connection of the output lead of communication interface with the computer must be
correct. Or otherwise, the output terminal of indicator and the communication input terminal
of computer will be damaged, even causing , severe damage of indicators, computer and
corresponding peripheral equipments.
2. Computer communication requires certain computer skill and programming ability of the
operator, who must be accompanied or led by some professional technicians.
Non-professionals are not supposed to connect without authorization.
Xk3190-d18 type weighing indicator can realize data communication with upper computer through Comm Setup
Two communication manners are selectable: continuous mode and instruction mode. In the instruction manner, one
upper computer can work with multiple indicators. (rs422/rs485)
1. Comm Method
(1) Communication interface of this indicator adopts a D-sub 15 pin socket. Signals of each pin are shown as 6-, 7-,
8-pin (rs232), or 1-, 2-, 3-, 4-, 8-pin (rs422/rs485)
,in Fig.(7-1). Serial communication and scoreboard display
share one socket.
This only applies to Yaohua Communication Interface Protocol. For any special
requirements, users can make connection according to the leading wire definition.
The data transmitted are the weighing result displayed on the indicator of the current load (gross weight or net
weight). Each frame contains 12 groups of data in the following form:
x-th byte Content and explanation
1 02 (xon) begin
2 +or- Sign bit
3 Weighing value High-Command bit
x-th byte content and explanation
: Weighing data
: Weighing data
6 03(xoff) end
The content of 4~n are as follows when the indicator is outputting data:
Command a no data Each frame consists of 6 groups of data
Command b as gross weight form: Each frame consists of 14 groups of data
4: sign(+or-)
5~11: gross weight value(6 digits and
one decimal digit)
Command c as tare, form: Each frame consists of 14 groups of data
4: sign(+or-)
47
XK3190-D18 Communications68
4: sign(+or-)
The connection of the output lead of large screen with the display must be correct. Or
otherwise, the output terminal of indicator and the input port of display of large screen will be
damaged, even causing severe damage of indicators, display of large screen. Self-contained
exclusive wires are required for the connecting.
1. Scoreboard display interface adopts 15-pin D-sub socket (share one socket with serial communication
interface). Functions of its pins are shown as 9-, 10-pin in Fig. (7-1). (This is an output manner of current loop, a
standard connection manner of wires on departure from factory)
2 . Scoreboard signal is current loop, serial output by binary code, with baud rate of 600. Each frame has 11 bits, 1
48
XK3190-D18 Communications68
start bit (0), 8 data bits (low bits come first), 1 flag bit, and 1 stop bit (1).
3. One group of data is transmitted per 100ms. Each group contains 3 frames. See Fig (7-2) for its meaning.
51
XK3190-D18 Print and Record Processing
Input area Input mode Instructions
VEH No. number/ English/sign at most 10 characters are to be input
Code (upper) number at most 3 digits are to be input
CGO No. number/English/sign at most 10 characters are to be input
Code (lower) number at most 3 digits are to be input
Notes:
(1) When there is reverse video in the input area, it means value can be input hereby. Select any from VEH No./CGO
No. and code area to fill
(2)If VEH No /CGO No. area is chosen for the input value; the indicator will retrieve the memory automatically after
【Input】 key is pressed, to see if there is any corresponding code. If so, the code is shown, if not, new code is generated
automatically and displayed. If the corresponding code of VEH No./CGO No. is known before hand, input the code
directly into the code area and the indicator will retrieve automatically the corresponding VEH No./CGO No. and they
are displayed. By this way, the relative complicate operations can be avoided. The VEH No./CGO No. can be input with
Chinese, English and numbers mixed. Press 【Input mode】 to switch over the input modes. After completion of
switchover between the four input areas, press【Input】 to save the VAL and execute printing operation. Printing is
canceled and return to the weighing interface if 【←】is pressed.
(3)The data storage adopts two manners, with or without VEH No. . (See the chapter Menu Operation for detailed
setting). If VEH No. is not used for setting, the license code is fixed as 0 and unchangeable.
(4)The data storage adopts two manners, with or without CGO No. (See the chapter Menu Operation for detailed
setting). If CGO No. is not used for setting, the item code is fixed as 0 and unchangeable.
(5)When the data is unstable or either the gross weight or the net weight is less than or equal to 0, records can not be
stored.
3. Print the weighing sheet (two times storage mode, first empty load then full load, or first full load then empty
load)
Procedures Situations Operations Display Instructions
1 Empty truck is loaded press 【Save Print】 Interface of inputting Press keys on the weighing interface.
(wait until the sign VEH No. & CGO No.
stabilize)
2 input new VEH No. e.g. : aa1245, VEH No.: aa1245 If the previous VEH No. is required,
54
XK3190-D18 Print and Record Processing
is already input directly.
previously, no 2. If no VEH No. is input, input the
need to input it code here.
here
5 press 【Input】 Save the code and Input the setting of
items no.
6 input CGO No. E.g. rolled steel. CGO no.: rolled steel. If the previous CGO No. is required,
Press 【Input】to directly press 【 Input 】 , without
save changing the CGO No...
7 press 【Input】 Input code area
8 input CGO No.. Code 1. if no CGO No.. code: 1 1. if CGO No. is already input, code
Is input already, will be produced automatically. Press
input code here. 【Input】 to skip.
2. if CGO No. is 2. If no CGO No. is input yet, input
already input the code here.
previously,.
Needless to input
anything here
Procedures Situations Operations Display Instructions
9 Press【Input】 Record incomplete, not Save the code and return to the
print right now! weighing interface
10 heavy truck is loaded Press【Save Print】 interface of inputting Display the VEH No. and CGO No.
(wait until the VEH No. / CGO No. previously input
stabilize sign on)
11 VEH No. inputting press【Input】 no need to input anything
state
12 VEH No. inputting press【Input】 no need to input anything
state
13 VEH No. inputting press【Input】 no need to input anything
state
14 CGO No.. inputting press【Input】 Printing… no need to input anything. Press
state 【Input】key to print out weighing
sheet
Attention: if heavy load is weighed for the first time, the empty load should be weighed next time. Other operations are
similar.
4. Automatic printing of the weighing sheet with tare preset
55
XK3190-D18 Print and Record Processing
Procedures Situations Operations Display Instructions
Set 『 printing method 』 as “automatic
printing” according to the requirements of
1
chapter Menu Operations , and press
【Weigh】to return to weighing interface
2 input the preset tare E.g.: 100 VAL: 100 kg
Save the VAL. The preset tare comes into
3 press【Input】
effect
4 Press【←】 Return to weighing interface
heavy truck is
loaded (wait until Heavy load is 500, with tare 100 to be
5 The weight reads 400 kg
the stabilizing sign reduced
on)
Print automatically the weighing sheet
6 Printing
when the weight display stabilizes
5. Print the weighing sheet while calling the tare as per VEH No.
Proc Situations Operations Display Instructions
edur
es
1 Tare of the VEH No. Already stored in the indicator
has been preset
2 Heavy truck is setting interface of VEH Display the previous license and
loaded (wait until Press 【VEH No.】 No. and tare tare
the stabilize sign on)
3 Input the required E.g. aa00123 VEH No.: aa00123 If consistent with the previous VEH
VEH No. press 【Input】to save No., directly press 【Tare】. There
is no need to input VEH No.
4 press【Input】 Input the setting of license code.
5 input the required press【Input】 1. If the license has been input,
VEH No. directly press 【 Input 】 without
inputting anything.
2. If no VEH No. is input
previously, input the VEH No. and
press 【Input】 to save
6 press 【Tare】 return to the weighing The value after deducting the saved
interface and display the tare
56
XK3190-D18 Print and Record Processing
net weight value. Net
weighing sign shines
7 Press 【Save Print】 interface of inputting press key under weighing interface
VEH No./CGO No.
Procedures Situations Operations Display Instructions
8 input new VEH No. E.g. aa1245 VEH No.: aa1245 If the previous VEH No. is
press 【Input】 required, directly press 【Input】
to save without changing the VEH No..
9 press【Input】 Input code area
10 input license code 1. If no VEH code: ** 1. If VEH No. is already input,
No. is input code will be produced
already, input automatically. Press 【Input】 to
code here. skip.
2. If VEH No. 2. If no VEH No. is input yet, input
is already input the code here.
previously, no
need to input
anything here
11 press【Input】 Save the code and Input the setting
of CGO No.
12 input CGO No. e.g.: rolled steel CGO No.: rolled steel. If the previous CGO No. is
press 【Input】 required , directly press 【Input】
to save without any need to change the
CGO No.
13 press【Input】 Input code area
14 input item code 1. If no CGO code: 0 VEH No.
No. is input,
input code here.
2. If CGO No.
is already input
previously, no
need to input
anything here
15 press【Input】 Print the weighing sheet
16 Return to weighing state
6. Print the weighing sheet manually with varied truck tares preset
57
XK3190-D18 Print and Record Processing
Procedures Situations Operations Display Instructions
1 press 【VEH No.】 interface of Press keys on the weighing interface
setting VEH
No. / tare
2 Input new VEH E.g. aa00123, press If the existing VEH No. is required,
No. 【Input】to save press 【Input】 without transmitting
new VEH No..
3 press【Input】 Input code area
4 press【Input】 Code is automatically generated
according to the previously input
VEH No. No need to set it here. Press
【Input】to Input the tare input area
5 transmit the preset e.g.: 100, Tare:
tare Press 【Input】to save 100 kg
6 Store preset tare 1. Press【Input】to input
for varied truck new VEH No. cyclically
and input the setting of
next vehicle
2. If VEH No./tare are all
input, press 【 ← 】 to
return to weighing.
interface
58
XK3190-D18 Print and Record Processing
record
press number keys to input finishing input the finishing date of the
date printed record
4 press【Input】 print the related three reports
VAL Instructions
Record Search scan the weighing record as per record time
VEH No... Search scan the weighing record as per the recorded VEH No.
CGO No. Search scan the weighing record as per the recorded CGO No.
Overload REC scan the past Overload REC
Scan Record scan all the weighing record
Delete All scan the valid CGO No. reserved
Delete Overload scan the past Overload REC
(1)Scan Record
press 【↑】【↓】 keys to select the manner of scan record. Press【Input】
59
XK3190-D18 Print and Record Processing
Scan Record 【123】
From 06/04/12 to 06/04/12
VEH: 555 Code: 0
CGO: 1111 Code: 1
Press【↑】
【↓】 keys to turn pages and scan record.
Delete All?
【←】 Back 【Input】Confirm
(7) Overload DEL
Press 【↑】
【↓】 keys to select 『Overload DEL』. Press 【Input】to Input the confirmation prompt for deletion.
Press【Input】to delete all the overloads. Press【←】to return to the previous menu. Overload DEL requires the correct
input of CAL PWD
61
XK3190-D18 Info prompts
Chapter 9 Info prompts
No. Indicator prompts Explanation Solutions
Record the confirmation operation
Select whether to clear according to
1 Time REC DEL? before deletion to prevent any wrong
the prompts
deletion.
Record the confirmation operation
Select whether to clear according to
2 VEH No. Rec DEL? before deletion to prevent any wrong
the prompts
deletion.
Record the confirmation operation
Select whether to clear according to
3 CGO No. Rec DEL ? before deletion to prevent any wrong
the prompts
deletion.
4 No CGO No. Rec.! Prompt of no corresponding record
5 No VEH No. Rec.! Prompt of no corresponding record
6 No Eligible Rec. Prompt of no corresponding record
7 No Overload REC Prompt of no corresponding record
Prompt of deletion process by
8 REC DEL! Wait! Wait for the completion of deletion
indicator
It’s time to turn off. The indicator is Re-input the timing power-off time as
9 Time power-off!
locked per the set password
10 Overload! the indicator is overloaded Unload the whole or partial weight
11 Printing...
Follow the standard Save Printing
specifications
●Not print when unsteady
zero
13 Not complete! Second weighing is needed
Parameter save by EEPROM is For delivered indicators, maybe
14 EEPROM ERROR! wrong, possibly due to the first use of EEPROM is damaged. A new chip is
indicator or damage of EEPROM required.
Printer not connected or damaged; or Check the connection of printer and
15 Printer error! printer model not compatible with the indicator, or change for a compatible
indicator printer.
16 Upgraded Prompt that data is saved
XK3190-D18 Info prompts
Input data correctly as per the prompt
17 Invalid The inputed data is beyond the range
of the indicator parameter range
1. All or part of the records need
deleting to make room for later
18 Records full Memory of weighing records is full
records
2. Memory needs initializing
19 No record No weighing record in the memory
20 Deleted Prompt of records deletion
63
XK3190-D18 Maintenance & Notes
Chapter 10 Maintenance & Notes
I. To ensure the clarity and service life of the indicator, it must be kept away from direct sunlight during using,
and the ground where the indicator stands must be smooth.
II. It is improper to use this indicator in a dustful or vibrant or damp environment.
III. The load cell and indicator need good connection. System must have a good ground connection, and kept away
from strong electric field, strong magnetic field. The load cell and indicator must be kept away from strong corrosive
substances and inflammable& explosive materials.
▲! Do not use it where inflammable gases or steams exist. Don’t use it for canning system of compressive
container.
▲! In the area where lightning and thunder happen frequently, reliable lightning arrester should be installed
to ensure the personal safety and to prevent any damage to the indicator and relative equipment caused by
lightning stroke.
▲!The load cell and indicator are both static sensitive equipments, so anti-static measures must be taken
during the use. It is strictly invalid to carry out welding operation or other operations with high current on the
weighing platform. In the stormy season, lightening prevention measures must be taken reliably to prevent any
damage to load cell and indicator caused by lightening stroke, and to guarantee the personal security of
operators and safe running of weighing devices and relative equipments.
IV. Strong solvents such as benzyl and nitro oils are forbidden for cleaning the housing
V. Don’t inject any liquid or other conductive particles so as to avoid any damage of indicator and electric shock
VI. Before plugging in or out of the connecting line between indicator and external equipment, the power of both
indicator and equipment should be cut off
▲!Before plugging in or out of the connecting line of load cell, the power of indicator should be cut off!
▲!Make sure that the indicator and the printer are powered off before inserting the connection line of
printer.
▲!Make sure that the indicator and the scoreboard are powered off before plugging in or out of the
connection line of the scoreboard!
▲!Make sure that the indicator and the upper computer are powered off before plugging in or out of the
communication connection line.
VII. Advice of the company: our company is responsible for the indicator quality, but not responsible for the
problems of the system where the indicator locates. Your attention is required when making purchase.
VIII. Please use the indicator outward interfaces strictly as per the operating instruction manual. Do not change the
connection at random. If failure occurs in the using process, draw the plug immediately, and send it for professional
factory for reparation. Non professional balance manufacturers are not supposed to do the repairing to avoid any worse
damage. It is not allowed to open the indicator at will, or else, repairing will be refused.
IX. If non artificial defects and failures happen after normal use within one year after the sale date, the users can mail
the product and guarantee repair card ( with correct code) to the appointed reparation station or supplier. The
manufacturer guarantees the life-time maintenance for the indicator
Appendix
1. Print Format
Report 1 by Time Date: 07/12/20 – 07/12/21
Gross
No Date Time VEH No. CGO No. Tare (kg) Net weight (kg)
weight (kg)
1 07/12/20 11:26:16 AA000001 rolled steel 1000 100 900
2 07/12/20 11:29:16 AA000001 rolled steel 1200 100 1100
3 07/12/20 11:32:16 AA000001 rolled steel 1400 100 1300
Total Gross weight: 3600 kg Net weight: 3300 kg
Note: Records in Report 1 by Time is to be listed in time order
Report 2 by Time Date: 07/12/20 – 07/12/21
No VEH No. Truck weight (kg) Times Grand gross weight (kg) Grand net weight (kg)
1 --------- 0 5 5000 5000
2 AA000001 0 3 3600 3300
3 AB000001 0 4 4000 3600
Note: Records in Report 2 by Time is to be listed in VEH No. order
Report 3 by Time Date: 07/12/20 – 07/12/21
No. CGO No. Time Grand net weight (kg)
1 ------------- 5 4500
2 Rolled steels 3 3300
3 stone 10 5600
Note: Record in Report 3 by Time is to be listed in CGO No. order.
Report 1
No Date Time VEH No. CGO Gross weight (kg) Tare (kg) Net weight
No.
1 06-11-22 11:26:16 ------- ------- 1200 0 1200
2 06-11-22 12:20:17 AA0001 oil 1500 200 1300
3 06-11-25 10:20:15 AB0001 Rolled 5600 600 5000
steel
Total: Gross weight: 8300 kg Net weight: 7500 kg
Note: Records in Report I is to be listed in time order
Report 2
No. VEH No. Truck weight (kg) Times Grand gross weight (kg) Grand net weight (kg)
1 ---------- 0 5 2600 2600
2 AA000001 100 4 5600 5000
3 AB000001 100 4 6600 6100
Note: Record in Report 2 is to be listed in VEH No. order
Report 3
No CGO No. Times )Grand net weight (kg)
1 ---------- 5 2600
2 rolled steel 4 5000
3 oil 4 6100
Note: Record in Report 3 is to be listed in CGO No. order
Report 4
No. Code VEH No. Truck weight (kg)
1 0 ------------- 0
2 1 AA000001 100
3 2 AB000001 100
Note: Report 4 shows the code and truck weight corresponding with the VEH No.
Report 5
No Code CGO No.
1 0 ----------
2 1 rolled steel
3 2 oil
Note: Report 5 shows the code corresponding with the CGO No.
Report 6
No. Date Time Gross weight (kg)
1 06-11-21 10:14:20 2000
2 06-11-22 10:15:00 5600
3 06-11-23 12:17:30 4000
Note: Report 6 shows the Overload RECs
66
2. Expandable function instruntion
PS/2 keyboard
Summary
XK3190-D18 indicator can be added PS/2 keyboard interface. For the convenience of users to connect the
indicator to popular key board, PS/2 interface adopts USB-A socket, which functions only as an interface. Insert the
plugof the indicator to the PS/2 keyboard at the back pnel of the indicator, and the PS/2 keyboard is enabled to control
the work of the indicator, Inputing all kinds of parameters.
Operation instructions
The function keys F1~F12, backspace key, cursor direction key of PS/2 keyboard correspond to the function keys
of D18, see the table below for detailed correspondence relation:
Table Correspondence Relation between PS/2 Keyboard and XK3190-D18 Function Keys
Save
XK3190-D18 F1 F2 CGO No. VEH No. Setup Inspection Fill PRT
tare
PS/2 F1 F2 F3 F4 F5 F6 F7 F8
Preset Save Calibratio
XK3190-D18 Report Print Zero Set Sum Print Input Clear
tare Print n
PS/2 F9 F10 F11 F12 PrtScr ScrollLock Input Backspace
Back
XK3190-D18 Input mode Axle Axle All Roll Weighing Select Tare
light
PS/2 Insert Break Home End PgUp PgDn Tab Del
XK3190-D18 ← ↑ → ↓
PS/2 ← ↑ → ↓
In the characters inputting status, the switchover of capitalization is same as that on the computers. When inputting
Chinese characters, they appear in the Pingyin area. And the characters on the keyboard can be Inputed directly.
USB interface
USB interface of XK3190-D18 is a device interface, adopting USB-B socket, available for connection to the upper
computer with the equipped USB cable, and to transmit weighing data and records to the upper computer. The data
transmission format is same as RS-232C interface.
Ethernet interface
XK3190-D18 is an expandable Ethernet interface, with specifications of 10Base-T/100Base-TX. It can be
connected to upper computer via LAN, and to internet by gateway, and transmit weighing data and records to the upper
computer.
DC 6V Power Interface
XK3190-D18 is an expandable DC 6V direct current power interface, and accept 6V storage battery with an input
voltage of 5.5~8V, which is displayed on the equipment. When the battery voltage is low, the running of microprinter is
stopped. When the battery voltage is too low, the equipment powers off automatically.
Expand ABLE interface
On the Main board of XK3190-D18, there are expandable interfaces,through which, 4-20m electric current loop,
CAN interface can be added
67